The Phoenix 50Hz Axial Air Mover is the industry’s only Air Mover specically engineered with patent pending
FOCUS
TM
Technology. FOCUS
TM
Technology revolutionizes evaporative drying by producing air velocities greater
than competitive product offerings. This highly focused air ow is directed towards the restoration industry’s
problematic drying areas namely, carpet and cushion, sub-oor, sill plate and walls. No other fan dries the
sill plate as quickly! Finally, the Phoenix 50Hz Axial Air Mover with FOCUS
TM
Technology sustains these air
velocities further than any other 50Hz Axial Air Mover.
The Phoenix 50Hz Axial Air Mover includes a 2-speed motor
delivering a focused airstream of approximately 4900 m3/hr
(2900 cfm), lightweight stackable enclosure designed to t existing
vehicle rigging, superior cord management and hour meter.
Conventional 50Hz Axial air movers create a circular air jet. With
a circular air jet the only way to get air into the square corner is to
point the fan towards the corner. This angle toward the wall wastes
valuable air velocity and throw distance. FOCUS
TM
Technology
creates an air jet with a square corner, resulting in optimized
drying ability. In addition, the 50Hz Axial Air Mover features built in
4.5° positioning which increases the fans ability to dry.
Dry fast, smart and protably with Phoenix.
Phoenix 50Hz Axial Air Mover
Approximately 4900 m3/hr (2900 cfm) air ow
directed where you need it.
Operator interface conveniently located for easy
access, featuring: power indicator lamp, large three-
position switch, and hour meter.
Units interlock for ease of stacking during storage and
handling.
Weighs more than 1kg less than competitive units.
Linear low density polyethylene construction.
Low bearing temperatures increase motor life.
Specifications subject to change without notice.
4201 Lien Rd • Madison, WI 53704
TS-699
01/13
Patent: 7,331,759
Phoenix 50Hz Axial Air Mover
PN 4030940
2
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
1 Safety Information
Do not operate the unit with a cut or frayed power cord.
Replace cord if it becomes damaged.
Do not unplug the unit by pulling on the cord. Grasp the
plug rmly and pull it out of the wall socket or power
receptacle.
Always use a grounded outlet.
Never operate electrical equipment in standing water.
Never operate with the safety grills removed. Personal
injury may result.
Do not stick your ngers or other objects through the
safety grills.
Do not restrict airow to the unit. This may cause the unit
to overheat.
Unit should never be serviced or cleaned while it is
plugged in.
Do not sit or stand on the unit or use as a shelf or table.
Before leaving an 50Hz Axial Air Mover unattended,
ensure children do not have access to the equipment. Do
not allow children to play with or near the unit or in its air
ow.
To reduce the risk of re or electric shock, do not use this
air mover with any solid-state speed control device.
Do not route cord under furniture or appliances.
LIRE ET CONSERVER CES INSTRUCTIONS
Risque de choc électrique Peut causer des blessures ou
la mort. Débrancher toutes les alimentations en courant
électrique à distance avant l’entretien ou le nettoyage.
Ne pas utiliser l’appareil avec un cordon d’alimentation
coupé ou efloché.
Ne pas débrancher l’appareil en tirant sur le cordon. Tenir
la che fermement et la tirer hors de la prise murale ou la
prise d’alimentation électrique.
Toujours utiliser une prise mise à la terre.
Ne jamais utiliser l’équipement électrique dans de l’eau
stagnante.
Ne jamais utiliser sans les grilles de protection. Des
blessures risquent d’en résulter.
Ne pas passer les doigts ou d’autres objets dans les
grilles de protection.
Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil.
L’appareil risque de trop chauffer.
Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas
l’utiliser comme étagère ou table.
Avant de laisser un appareil aéraulique 50Hz Axial sans
surveillance, s’assurer que les enfants n’ont pas accès
à l’équipement. Ne pas laisser les enfants jouer avec
l’appareil ou à proximité de l’appareil ou dans l’air qu’il
projette.
Pour réduire le risque d’incendie ou de choc électrique, ne
pas utiliser ce ventilateur avec un dispositif de commande
de vitesse à semi-conducteurs.
Table of Contents
Introduction ............................................................................1
FOCUS
TM
Technology Features and Benets.........................1
1. Safety Information ..........................................................2
2. Intended Application ....................................................... 3
3. Safety Certications ........................................................ 3
4. Specications ..................................................................3
5. Power Requirements.......................................................3
5.1 International Cord/Plug Set .....................................3
5.2 Integrated Cord Wrap ................................................3
6. Applications ..................................................................... 3
6.1 Sizing for Water Restoration Jobs .............................3
6.2 Placement .................................................................. 3
6.3 Orienting of Directional Drying System ....................4
7. Operating Instructions ....................................................4
8. Operator Panel Features .................................................5
8.1 Run-Time Hour Meter ................................................ 5
8.2 Power Indication Lamp ............................................. 5
8.3 3-Position Drying Selector Switch ............................5
9. Maintenance ....................................................................5
9.1 Servicing ....................................................................5
9.2 Cleaning .....................................................................5
10. Replacement Parts and Optional Accessories .............6
11. Wiring Diagram ............................................................... 6
Warranty ........................................................................... 7
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
3
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
2 Intended Application
The Phoenix 50Hz Axial Air Mover has changed the
drying industry by minimizing overall drying time on water
restoration jobs. The Phoenix 50Hz Axial Air Mover uses
patent pending FOCUS Technology to maximize air velocity
across oors and along walls for longer distances. By
maximizing the air velocity, water evaporates more quickly
from the carpet, cushion, sub-oor, wall, and sill plate.
3 Safety Certifications
The Phoenix 50Hz Axial Air Mover (P/N 4030940) conforms
to UL STD 507. Certied to CAN/CSA STD C22.2 No. 113.
4 Specifications
Part No. 4030940
Motor 1/4 hp 2-speed
4-pole, PSC Electric Motor.
Cords
4028264 IEC C13 to BS 1363 U.K. Plug
4028265 IEC C13 to AS 3112 Australian Plug
4028268 IEC C13 to CEE 7/7 European Plug
Air Flow Approximately 4900 m3/hr (2900 cfm)
Cord 7 m Power Cord (20 ft)
Current High - 1.4 Amps
Low - 1.25 Amps
Voltage 230 volts/50hz
Warranty Year One - 100% parts and labor
(all components)
Year Two - 100% parts only (all components)
Years Three through Seven - Only materials
and workmanship of the housing are covered.
Dimensions
Cabinet
Width 51 cm (19.9”)
Height 50 cm (19.5”)
Depth 39 cm (15.2”)
Weight 13.4 kg (29.5 Lbs)
5 Power Requirements
5.1 International Cord/Plug Set
Connect the appropriate Cord/Plug set (provided) to the IEC
C13 connector. The Phoenix 50Hz Axial Air Mover draws 1.28
Amps; 230 volts and should be plugged into an appropriate
grounded (earthed) outlet.
5.2 Integrated Cord Wrap
The Phoenix 50Hz Axial Air Mover features integrated cord
management. Wrap the cord around the cord wrap as shown
and tuck under the previous wrap.
6 Applications
6.1 Sizing for Water Restoration Jobs
Current industry standards call for one air mover per 3-5
meters (10-16 linear feet) of wall space, dependent upon the
Class of water damage. For commercial structures, the indus-
try standard calls for one air mover for every 4.6 - 5.6 square
meters (50-60 square feet).
The water restoration industry based these estimates on the
air mover technology available when writing the standards.
Following these equipment-sizing standards when using the
Phoenix 50Hz Axial Air Mover will result in dramatically faster
drying times. If the restoration professional desires to merely
achieve industry standard drying times, he can use fewer
Phoenix 50Hz Axial Air Movers than standard equipment
standards allow.
6.2 Placement
Current industry guidelines suggest placing air movers at a
15° - 45° angle to wall. These guidelines apply to air mov-
ers without FOCUS Technology. FOCUS Technology allows the
restoration professional to place the Phoenix 50Hz Axial Air
Mover at an angle nearly parallel to the wall.
The test graph shown below depicts immediate air ow at the
FOCUS Technology corner. The 50Hz Axial Air Mover sustains
this air ow for more than 6 meters (20 feet) and maximizes
the air velocity across the oor and along the wall when
placed the at 4.5° angle from the wall.
By touching the front edge of the output side of the 50Hz
Axial air mover against the wall and rotating the rest of
Figure 3: Cord wrap
4
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
Figure 8: Clockwise feet locations
the unit against the wall, the restoration professional will
place the 50Hz Axial air mover at 4.5° due to the housing’s
built-in design. Industry experts agree placing 50Hz Axial Air
Movers 45° angle to the wall wastes air ow and reduces the
performance by forcing air up the wall.
The best set up angle for quickly and completely drying the
sill plate is 4.5°. Set-up angles greater than 4.5° may be
used under unique circumstances such as corner air ow and
structure variations. Set-up angle should never exceed 23°.
Figure 5: 4.5° to wall
as shown
Figure 6: Placement for counter-clockwise drying
Figure 7: Birds eye view of room set-up
Counter
clockwise
airflow
pattern
Clockwise
airflow
pattern
Making use of factory installed feet (4) Making use of user installed feet (2)
User installed feet
for use during
clockwise drying
set-ups
Factory installed feet for use
during counter clockwise drying
6.3 Orienting of Directional Drying System
The 50Hz Axial air mover dries in counter-clockwise and
clockwise directions for optimum ease of use. The 50Hz Axial
air mover ships with rubber feet on one side of the unit for
counter-clockwise drying.
When the water restoration professional needs to employ
clockwise drying (such as the need to dry a door jamb),
simply rotate the 50Hz Axial air mover 90° so the FOCUS
Technology corner points toward the door jamb and oor for
the clockwise drying.
If the water restoration professional dries in the clockwise
direction often, we suggest attaching the two (factory
provided) rubber feet into the threaded holes on the side
of the unit. By attaching the rubber feet and creating the
optimal downward angle of 4.5°, the Phoenix 50Hz Axial
Air Mover will maximize air velocity across the oor and wall
when drying in the clockwise direction.
Figure 4: Airow of the Phoenix 50Hz Axial Air Mover mea-
sured 3.5” parallel to wall.
2500
2000
1500
1000
500
0
0 Feet 5 10 15 20 25
Air Velocity (fpm)
Immediate high velocity air ow at
the outlet of the fan.
7 Operating Instructions
The Phoenix 50Hz Axial Air Mover as packaged is ready to be
put into service after attaching the appropriate plug/cord set.
Inspect the unit completely for any shipping damage. Place
the unit on the ground. Orient the unit so the desired air ow
direction is the same as the arrow indicator sticker in the
FOCUS Technology corner on the interior of the unit. Plug the
unit into a grounded outlet and select the drying mode shown
in Figure 9.
5
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
Figure 9: 50Hz Axial Air Mover Operator Panel
8 Operator Panel Features
8.1 Run-Time Hour Meter
The operator interface panel is equipped with an Automatic
LCD (Liquid Crystal Display) Hour meter. This hour meter
displays cumulative run time. The hour meter meets IP65
for moisture and dust protection and is designed to survive
harsh restoration and water recovery applications. The hour
meter features non-volatile eeProm memory. This type of
memory cannot be erased, nor reset. This feature ensures
accurate time tracking.
The display can be used to track time-of-operation and time-
to-dry. Some restoration professionals use the hour meters to
help them establish billable hours.
8.2 Power Indication Lamp
The red, sealed, high intensity AC voltage power indication
lamp allows operators to visually identify the operation status
of several Phoenix 50Hz Axial Air Movers at a distance, with a
single glance. The power indication lamp will remain lit when
the AC power cord is plugged into a standard “powered”
AC power outlet and the 3-position drying selector switch
is in either the HIGH or LOW operation position. The power
indication lamp will remain unlit when the AC power cord is
unplugged, the 3-position drying selector switch in the OFF
position, or the connected, standard AC wall outlet power has
been turned off.
8.3 3-Position Drying Selector Switch
The 3-position drying mode selector switch. This switch is
used to select the Phoenix 50Hz Axial Air Mover’s mode of
operation. The 3 modes of operation are OFF, LOW or HIGH.
9 Maintenance
WARNING: Disconnect the unit from power before servicing
or cleaning. Replace the wire safety grill after
servicing or cleaning.
9.1 Servicing
Before each use inspect for damage, blocked inlet or outlet,
or any excess buildup of foreign material.
When the Phoenix 50Hz Axial Air Mover is rst turned on,
check for excessive vibration. If the unit vibrates excessively
or if blade rubs on housing, turn off the unit immediately.
Have a service technician inspect the unit to locate the
problem.
9.2 Cleaning
The housing is made of a durable and washable polyethylene.
When cleaning, the use of solvents is NOT recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the operator interface panel with a
cloth. Clean inner barrel, grills and blade. Wipe down motor
exterior with a damp cloth. If the motor gets wet during
cleaning, simply allow ample time for motor to dry out
completely before restarting.
If you wash the 50Hz Axial Air Mover and do not plan to use it
within 24 hours, allow the fan to drip dry for 10 minutes and
then let run for 5 minutes.
Hour Meter
3-Position
Selector Switch
Power
Indication
Lamp
6
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
Figure 11: Optional stand
allows the 50Hz Axial
Air Mover’s air ow to be
directed in a 360° range of
movement. (PN 4025460)
GRY
ORG
WHT
GRY
1
2
3
4
5
BLU or WHT
BRN or BLK
6
YEL
GRY
RED (low)
BRN (high)
GROUNDED
PLUG
M
CAPACITOR
BLK
BLK
left hand pole
right hand pole
GRY
230 VAC
50 hz
Note: Switch is Double Pole, Double Throw
GRY
YEL
10 Replacement Parts and
Optional Accessories
Contact the factory at 1-800-533-7533 or 1-608-237-8400
to order replacement parts, or optional accessories
4029721 Switch, Rocker, On-Off-On
4025320 Grill, Safety, Intake
4025321 Grill, Safety, Exhaust
4025460 Axial Air Mover Stand
4025299 Stand Hardware Kit
4031968 Motor
4031969 Blade
4028795 Hour Meter
11 Wiring Diagram
7
www.UsePhoenix.com • [email protected]Toll-Free 1-800-533-7533 or 1-608-237-8400
Specifications subject to change without notice.
Phoenix 50Hz Axial Air Mover Limited Warranty
Warrantor:
Therma-Stor LLC
4201 Lien Rd
Madison, WI 53704
Telephone: 1-800-533-7533
Who Is Covered: This warranty covers Phoenix 50Hz Axial Air Movers.
First Year Warranty: 100% parts and labor (all components)
Second Year Warranty: 100% parts only (all components)
Years Three through Seven: Only materials and workmanship of the housing are covered.
If a defect in materials or workmanship occurs within the warranty period, Therma-Stor LLC will repair
or replace the defect.
End-User Responsibilities: Warranty service must be performed by a servicer authorized by Therma-
Stor Products. To obtain warranty service you must obtain a return material authorization (RMA).
To obtain an RMA you must present proof of purchase or (lease), by use of a warranty card, original
sales receipt or other reasonable and reliable means.
To obtain an RMA call Therma-Stor LLC at the above number and ask for the Therma-Stor LLC
Service Department, which will then issue an RMA# and arrange for, at our option, either repair or
replacement.
Freight: Freight to and from the servicer is the responsibility of the end-user. The end-user is
responsible for normal care and proper return packaging.
Limitations and Exclusions: This warranty does not cover any defect, malfunction, etc. resulting from
misuse, abuse, lack of normal care, corrosion, freezing, tampering, modication, unauthorized or
improper repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC’s
reasonable control.
If any Phoenix 50Hz Axial Air Mover part is repaired or replaced, the new part shall be warranted for
the balance of original warranty (but all warranty periods will be extended by the period of time, if
any, that the Phoenix 50Hz Axial Air Mover with FOCUS Technology is out of service while awaiting
covered warranty service).
Warranty service will be performed during normal working hours.
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX 50Hz Axial
AIR MOVER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL
WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE
AGAINST THERMA-STOR BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC,
IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY PHOENIX
50Hz Axial AIR MOVER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL,
INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE
END USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR
DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not
allow the exclusion or limitation of incidental or consequential damages, so one or both of these
limitations may not apply to you.
Legal Rights: This warranty gives you specic legal rights, and you may also have other rights which
vary from state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Phoenix 4030940 Installation, Operation & Service Instructions

Taper
Installation, Operation & Service Instructions

dans d''autres langues