LG LMAN125HV Le manuel du propriétaire

Taper
Le manuel du propriétaire
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : Standard / Standard Libero
Artcool Mirror
Ceiling Cassette
http://www.lghvac.com
www.lg.com
P/NO : MFL39817411
ENGLISH FRANÇAIS ESPAÑOL
2 Multi Air Conditioner
Multi-Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
n Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
A. Safety Precautions ..........................3
B. Electrical Safety...............................6
Temporary Use of an Adapter...........6
Symbols used in this Manual ............6
C. Product Introduction.......................7
Indoor Units.......................................7
Outdoor Unit......................................7
D. Operating Instructions....................8
How to insert the Batteries ................8
Wireless Remote Controller
Maintenance......................................8
Operation Indication Lamps ..............9
Operating Method .............................9
Wireless Remote Controller ............10
Wired Remote Controller (Optional)
...12
Operation Mode ..............................13
Healthy Dehumidification Operation14
Air Circulation Operation .................14
Auto Operation ................................14
PLASMA Purification Operation
(Optional) ........................................14
Jet Cool/Heat Operation..................15
Energy-Saving Cooling Mode
(Optional) ........................................15
Display Luminosity (Optional) .........15
Sleep Mode Operation (Optional) ...15
Auto Clean(Optional).......................16
Setting the Current Time .................16
Timer Setting...................................16
To cancel the Timer Setting ............16
Forced operation .............................17
Auto Restart Function .....................17
Horizontal Vane Control (Up/Down
Airflow Direction Control) ................18
Vertical Louver Control (Left/Right Airflow
Direction Control) (Optional)................
18
E. Maintenance and Service..............19
Standard/Standard Libero/Artcool
Mirror Type......................................19
Ceiling Cassette Type .....................20
Operation Tips!................................21
Owner's Manual 3
Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
n Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
Always use a power plug and socket with
a ground terminal.
• There is a risk of electric shock.
Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control
box securely.
• There is risk of fire or electric shock due to
dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
Do not install the product on a defective
installation stand. Be sure that the
installation area does not deteriorate with
age.
• It may cause product to fall.
Never install the outdoor unit on a
moving base or a place from where it
can fall down.
• The falling outdoor unit can cause damage or
injury or even death of a person.
When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.
• An charged capacitor can cause electrical
shock.
When installing the unit, use the
installation kit provided with the product.
• Otherwise the unit may fall and cause severe
injury.
Be sure to use only those parts which
are listed in the svc parts list. Never
attempt to modify the equipment.
The use of inappropriate parts can cause an
electrical shock, excessive heat generation or fire.
4 Multi Air Conditioner
Safety Precautions
Indoor/outdoor wiring connections must
be secured tightly and the cable should
be routed properly so that there is no
force pulling the cable from the
connection terminals.
• Improper or loose connections can cause
heat generation or fire.
Safely dispose off the packing materials.
Like screws, nails, batteries, broken
things etc after installation or svc and
then tear away and thraw away the plastic
packaging bags.
• Children may play with them and cause
injury.
Make sure to check that the power cable
plug is not dirty, loose or broken and
then only insert the plug completely.
• Dirty, loose or broken power plug can cause
electric shock or fire.
Be sure to check the refrigerant to the
used. Please read the label on the product.
• Incorrect refrigerant used can prevent the
normal operation of the unit.
Don't use a power cord, a plug or a loose
socket which is damaged.
• Otherwise it may cause a fire or electrical
shock.
Do not touch , operate, or repair the
product with wet hands. Hold the plug by
hand when taking out
• There is risk of electric shock or fire.
Do not place a heater or other heating
appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric
parts. Install the unit away from water
sources.
• There is risk of fire, failure of the product, or
electric shock.
Do not store or use or even allow
flammable gas or combustibles near the
product.
• There is risk of fire.
Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.
• Oxygen deficiency could occur and hence
harm your health.
Do not open the front grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock,
or product failure.
If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to
time when operating it together with a
stove, or heating element etc.
• Oxygen deficiency can occur and hence harm
your health.
Turn the main power off and unplug the
unit when cleaning or repairing the
product.
• There is risk of electric shock.
When the product is not to be used for a
long time, disconnect the power supply
plug or turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody
especially kids could step on or fall onto
the outdoor unit.
• This could result in personal injury and
product damage.
Take care to ensure that power cable
could not be pulled out or damaged
during operation.
• There is risk of fire or electric shock.
Do not place ANYTHING on the power
cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug to turn the unit
ON/OFF .
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of
explosion or fire.
Two or more people must lift and
transport the product.
• Avoid personal injury.
Do not install the product where it will be
exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Install the drain hose to ensure that the
condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the
product.
• To avoid vibration or noise.
Do not install the product where the noise
or hot air from the outdoor unit could
damage or disturb the neighborhoods.
• It may cause a problem for your neighbors
and hence dispute.
Always check for gas (refrigerant)
leakage after installation or repair of
product.
• Low refrigerant levels may cause failure of
product.
Owner's Manual 5
Safety Precautions
ENGLISH
Do not use the product for special purposes,
such as preserving foods, works of art, etc. It
is a consumer air conditioner, not a precision
refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use
harsh detergents, solvents or splashing
water etc .
• There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Do not touch the metal parts of the
product when removing the air filter.
• There is risk of personal injury.
Do not step on or put anyting on the
product. (outdoor units)
• There is risk of personal injury and failure of
product.
Always insert the filter securely after
cleaning. Clean the filter every two weeks
or more often if necessary.
• A dirty filter reduces the efficiency.
Do not insert hands or other objects
through the air inlet or outlet while the
product is operating.
• There are sharp and moving parts that could
cause personal injury.
Be cautious when unpacking and
installing the product.
• Sharp edges could cause injury.
If the refrigerant gas leaks during the
repair, do not touch the leakaing
refrigerant gas.
• The refrigernat gas can cause frostbite (cold
burn)
Do not tilt the unit when removing or
uninstalling it.
• The condensed water inside can spill .
Do not mix air or gas other than the
specified refrigerant used in the system .
• If air enters the refrigerant system, an
excessively high pressure results, causing
equipment damage or injury.
If the refrigerant gas leaks during the
installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
Dismantling the unit, treatment of the
refrigerant oil and eventual parts should
be done in accordance with local and
national standards.
Replace the all batteries in the remote
control with new ones of the same type.
Do not mix old and new batteries or
different types of batteries.
• There is risk of fire or product failure.
Do not recharge or disassemble the
batteries. Do not dispose off batteries in
a fire.
• They may burn or explode.
If the liquid from the batteries gets onto
your skin or clothes, wash it well with
clean water. Do not use the remote if the
batteries have leaked.
• The chemicals in batteries could cause burns
or other health hazards.
If you eat the liquid from the batteries,
brush your teeth and see doctor. Do not
use the remote if the batteries have
leaked.
• The chemicals in batteries could cause burns
or other health hazards.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and wet or damage
furniture.
Do not expose your skin or kids or
plants to the cool or hot air draft.
• This could harm to your health.
Do not drink the water drained from the
product.
• It is not sanitary and could cause serious
health issues.
Use a firm stool or ladder when cleaning,
maintaining or repairing the product at
an height.
• Be careful and avoid personal injury.
6 Multi Air Conditioner
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
Temporary Use of an Adapter
Electrical Safety
Owner's Manual 7
Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your
indoor unit type.
h The figure can be changed according to model.
Product Introduction
Signal receiver
Front panel
Air discharge
ON/OFF button
Plasma filter
Air inlet
Air filter
Air inlet
Plasma filter (Optional)
[Standard Type] [Artcool Mirror Type]
Air filter
Air outlet
Front grille
ON/OFF button
Signal
receiver
Grille tab
Flap
(Horizontal blade)
Louvers
(Vertical blades)
[Ceiling Cassette Type][Standard Libero Type]
Cabinet
Air Discharge
Air Inlet
Signal receiver
Front Panel
Operation lamp
Signal Receiver
ON/OFF button
Air inlet
Plasma filter
Air filter
Front grille
Vertical louver
Allergy free filter
Air outlet
Horizontal vane
Horizontal vane
Horizontal vane
Triple filter
ENGLISH
Air outlet vents
Base plate
Connection pipe
Drain hose
Connecting wire
Control cover
Air intake vents
Outdoor Unit
Indoor Units
Product Introduction
Wireless Remote Controller Maintenance
1. Remove the battery cover by pulling it according to the arrow
direction.
2. Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.(Battery Size = AAA)
3. Reattach the cover by sliding it back into position.
1. Always use/replace both batteries of same type.
2. If the system is not to be used for a long time, remove the
batteries to save their working life.
3. If the display screen of remote controller starts, fading replace
both of the batteries.
NOTE
1. Choose a suitable place where its safe & easy
to reach.
2. Fix the holder to wall etc with the supplied
screws firmly.
3. Slide the remote controller inside the holder.
1. Remote controller should never be exposed to
direct sunlight.
2. Signal transmitter & receiver should always be
clean for proper communication. Use a soft
cloth to clean them.
3. In case some other appliances also get
operated with remote control, change their
position or consult your serviceman.
NOTE
8 Multi Air Conditioner
Operating Instructions
How to insert the Batteries
Operating Instructions
Owner's Manual 9
Operating Instructions
1. The signal receiver is inside the unit.
2.
Aim the remote controller towards the unit to operate it.
There should not be any blockage in between.
Ceiling Cassette TypeStandard Libero Type
Standard Type
Artcool Mirror Type
Operating Method
ENGLISH
[Standard/Artcool Mirror Type]
On/Off : Lights up during the system operation, error code and auto restart setting.
Sleep mode : Lights up during sleep mode auto operation.
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
Timer : Lights up during timer operation.
Defrost mode : Lights up during defrost mode or *hot start operation.
Power Display : Indicates the setting temperature and operation mode.
*
Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit.
* In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat
exchanger coils to maintain the efficiency.
[Standard Libero Type]
• Cooling : 'Cooling' lamp lights up during Cooling Operation
• Heating : 'Heating' lamp lights up during Heating Operation
• Plasma : 'Plasma' lamp lights up during Plasma Purification Operation
[ During Air Circulation Operation, 'Cooling' lamp lights up.
[
While Plasma Purification operates with Air Circulation Operation, ‘Cooling’ lamp and ‘Plasma’ lamp lights up at the same time.
[Ceiling Cassette Type]
On/Off : Lights up during the system operation.
Filter Sign : Lights up after 2400 hours from the time of first operating unit.
Timer : Lights up during Timer operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)
Forced : To operate the unit when the remote control can't be used for any reason.
Operation mode Cooling, heating, Dehumidification Mode Jet Cool Auto clean
Shape of display Setting temperature
Operation Indication Lamps
10 Multi Air Conditioner
Operating Instructions
Wireless Remote Controller
Cooling Mode
Auto Operation
Dehumidification mode
Heating Mode
Fan Mode
Cooling Model( ), Heat Pump Model( )
Operation Mode
3
4
6
8
9
5
7
14
15
17
16
10
12
13
11
2
1
1. VANE ANGLE Button
Used to set each vane angle.
2. FUNCTION SETTING Button
Used to set or clear Auto Clean, Smart Clean, Electric
heater or Individual vane angle control.
3. ON/OFF Button
Used to turn on/off the unit.
4. JET COOL Button
Speed cooling operates super high fan speed.
5. LEFT/RIGHT AIRFLOW Button (OPTIONAL)
Used to set the desired left/right(horizontal) airflow
direction.
6. UP/DOWN AIRFLOW Button
Used to stop or start louver movement and set the
desired up/down airflow direction.
7. ON TIMER Button
Used to set the time of starting operation.
8. SLEEP TIMER Button
Used to set the time of sleeping operation.
9. SET / CLEAR Button
Used to set/clear the timer.
Used to set the current time(if it input for 3sec.)
10. PLASMA Button (OPTIONAL)
Used to start or stop the plasma-purification function.
11. ROOM TEMPERATURE SETTING Button
Used to select the room temperature.
12. OPERATION MODE SELECTION Button
Used to select the operation mode.
13. INDOOR FAN SPEED SELECTION Button
Used to select fan speed in four steps low, medium,
high and chaos.
14. ROOM TEMPERATURE CHECKING Button
Used to check the room temperature.
15. OFF TIMER Button
Used to set the time of stopping operation.
16. TIMER SETTING(Up/Down)/LIGHT Button
Used to set the timer.
Used to adjust the brightness.(if it is not time adjust
mode)
17. RESET Button
Used to reset the remote controller.
h Some functions may not be operated and displayed depending on the product type.
NOTE
Owner's Manual 11
Operating Instructions
ENGLISH
Wired Remote Controller (Optional)
h Display temperature can be different from actual room temperature if the remote controller is
installed at the place where sun-rays are falling directly or the place nearby heat source.
h
The actual product can be different from above contents depending upon model type.
NOTE
1
4
5
7
11
10
9
8
2
3
6
13
12
14
15
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
OPERATION INDICATION
SCREEN
SET TEMPERATURE BUTTON
FAN SPEED BUTTON
ON/OFF BUTTON
OPRATION MODE SELECTION
BUTTON
WIRELESS REMOTE
CONTROLLER RECEIVER
• Some products don't receive the
wireless signals.
AIR FLOW BUTTON
SUBFUNCTION BUTTON
FUNCTION SETTING BUTTON
VENTILATION
BUTTON(OPTIONAL)
RESERVATION
UP,DOWN,LEFT,RIGHT BUTTON
• To check the indoor temperature,
press button.
ROOM TEMPERATURE BUTTON
SETTING/CANCEL BUTTON
EXIT BUTTON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
h Model : PQRCVSL0, PQRCVSL0QW
Cooling
Healthy
Dehumidification
Heating
(Heat pump model only)
Auto Operation
Air Circulation
To lower the temperature
To raise the temperature
Press the ON/OFF BUTTON to turn the unit on.
The unit will respond with a beep.
Open the door of the remote controller and press the operation mode button. Each time the button
is pressed, the operation mode is shifted in the direction of the arrow.
For cooling or heating operation set the desired indoor
temperature by pressing the ROOM TEMPERATURE SETTING
BUTTONS.
For cooling the temperature can be set within
18°C~30°C(64°F~86°F) and for heating the temperature range is
16°C~30°C(60°F~86°F).
Set the fan speed with the remote controller. You can select the fan speed by pressing the
INDOOR FAN SPEED SELECTOR BUTTON.
Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Natural wind
o
For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS or Natural wind
mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed.
12 Multi Air Conditioner
Operating Instructions
Operation Mode
Owner's Manual 13
Operating Instructions
ENGLISH
Plasma filter is a technology developed by LG to get rid of microscopic
contaminants in the intake air by generating a plasma of high charge electrons.
This plasma kills and destroys the contaminants completely to provide clean and
hygienic air.
Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller.
Repressing it will deactivate the operation.
This feature can be used in any operation mode and any fan speed can be used while
plasma filter is functioning.
NOTE
This operation circulates the air without cooling or heating. It can be
activated by pressing the OPERATION MODE SELECTION BUTTON.
Once the air circulation is activated you can select the air speed by
pressing the INDOOR FAN SPEED SELECTOR BUTTON.
: During this opertion, 'Cooling' lamp lights up.
(Standard Libero Type)
NOTE
During Healthy Dehumidification Operation
o If you select the dehumidification mode on the OPERATION MODE SELECTION
BUTTON, the product starts to run the dehumidification function. It automatically
sets the room temperature and airflow volume to the best condition for
dehumidification, based on the sensed current room temperature.
In this case, however, the setting temperature is not displayed on the remote
controller and you are not able to control the room temperature either.
o During the healthy dehumidification function, the airflow volume is automatically set
according to the optimization algorithm responding to the current room temperature status,
so that the room condition is kept healthy and comfortable even in the very humid season.
In this operation mode, the system is automatically operated by the
electronic controls.
- You can set the desired temperature between 64°F and 86°F for Auto
Operation mode.
This function properly operates when you use the remote controller
matching each model.
NOTE
PLASMA Purification Operation (Optional)
Auto Operation
Air Circulation Operation
Healthy Dehumidification Operation
14 Multi Air Conditioner
Jet cool function can be used to cool the room quickly in hot summer. When this
function is turned on, the air conditioner runs in cooling operation mode with super high
fan speed and 18°C(64°F) setting temperature for 30 minutes for fast and effective
cooling.
You can activate this operation by pressing the JET COOL BUTTON.
To change from jet cool mode to high fan speed cooling mode, press the JET COOL
BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE
SETTING BUTTON again.
Operating Instructions
Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by
setting body-adaptation time according to the change of time and temperature and adjusting desired
temperature automatically.
1. Press the FUNCTION button 2 time.
Energy-Saving Cooling symbol will blink.
2. Press the SET/CLEAR button the reserve or the Energy-Saving
Cooling function.
The Display Luminosity can be adjusted by using the remote control.
Open the cover of the remote controller, and press the LCD/LED LUMINOSITY button.
Display will be dark. Press the button again to set bright display.
• The sleep mode will operate indoor fan at super low speed in cooling mode and at low speed in heating
mode for pleasant sleep.
NOTE
Display Luminosity (Optional)
Energy-Saving Cooling Mode (Optional)
Jet Cool Operation
Owner's Manual 15
Operating Instructions
ENGLISH
o During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification
operation can be removed.
This function operate when the unit is turned off.
1. Press the FUNCTION SETTING button 1 time.
Auto Clean symbol will blink.
2. Press the SET/CLEAR button to reserve or cancel the Auto Clean function.
Auto Clean(Optional)
1. Press the SET / CLEAN button for 3 seconds.
2. Press TIME SETTING buttons until the desired
time is set. (If you press down the button for a long
time, it will change quickly in the units of 10 min.)
3. Press the SET / CLEAR button.
Check the indicator for A.M. and P.M.
Setting the Current Time
1. Press the TIMER button to turn timer on or off.
2. Press TIME SETTING buttons until the desired time
is set. (7 hours is the maximum setting)
3. Press the SET / CLEAR button.
Sleep Timer Setting
Timer Sleep
16 Multi Air Conditioner
Operating Instructions
1. Press the ON button to turn timer on or off.
2. Press TIME SETTING buttons until the desired time
is set.
3. Press the SET / CLEAR button.
On Timer Setting
Timer ON
To cancel the Timer Setting
• If you wish to cancel all timer setting, press the CLEAR ALL button.
• If you wish to cancel each timer setting, press the
each timer button to turn timer sleep or on or off as you want.
And then press the SET/CLEAR button aiming the remote
controller at the signal receptor.
(The timer lamp on the air conditioner and the display will go off.)
1. Press the OFF button to turn timer on or off.
2. Press TIME SETTING buttons until the desired time
is set.
3. Press the SET / CLEAR button.
Off Timer Setting
Timer OFF
Owner's Manual 17
Operating Instructions
Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.
ON/OFF
button
ON/OFF
button
Forced Operation
Button
[Ceiling Cassette Type][Standard Libero Type]
[Standard Type][Artcool Mirror Type]
ON/OFF
button
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller
sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.
This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6
seconds. The unit will beep twice and the lamp will blink 8 times.
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.
NOTE
This function is useful in the situation of power failure.
When power regains after a failure this feature restore the previous operating condition
and the air conditioner will run in the same settings.
Auto Restart Function
Heat pump Model
Room Temp. ≥ 24°C(75.2°F)
21°C(69.8°F) ≤ Room Temp. < 24°C(75.2°F)
Room Temp. < 21°C(69.8°F)
Operating mode
Cooling
Healthy Dehumidification
Heating
Indoor FAN Speed
High High High
Setting Temperature
22°C(71.6°F) 23°C(73.4°F) 24°C(75.2°F)
ENGLISH
Forced operation
18 Multi Air Conditioner
Operating Instructions
The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.
1. Press the ON/OFF button to start the unit.
2. Press UP/DOWN AIRFLOW button and the louvers will swing up and down.
Press the UP/DOWN AIRFLOW button again to set the vertical louver at the desired airflow direction.
• If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based
on the Auto Swing algorithm to distribute the air in the room evenly and at the same time to make the human
body feel more comfortable, as if enjoying a natural breeze.
• Always use the remote controller to adjust the up/down airflow direction. Manually moving the vertical airflow
direction louver by hand, could damage the air conditioner.
• When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.
The left/right(horizontal) airflow can be adjusted by using the remote control.
1. Press the ON/OFF button to start the unit.
2. Press the LEFT/RIGHT AIRFLOW button and the louvers will swing left and right. Press
the Horizontal Airflow Direction Control Button again to set the horizontal louver at the
desired airflow direction.
h Up/Down and Left/Right Airflow function isn’t shown on display of remote controller.
Left/Right Airflow Direction Control (Optional)
Up/Down Airflow Direction Control (Optional)
Owner's Manual 19
ENGLISH
Operating Instructions
• There may be differences between wireless remote controller up/down/left/right buttons and the wind
discharge port directions.
• Set desired angle with checking the vane angle movement of the product.
• The individual vane control function is an additional function of a product, and it may not work in some
products.
Individual vane angle control (Optional)
Press SET/CLEAR button to reserve or cancel the individual vane angle control function.
3
It is the function that can control 4 vane angles individually in the ceiling type 4Way
cassette product group.
Press the FUNCTION SETTING button 3 times.
(4 times during heating operation)
Individual vane angle control symbol will blink.
• If you press the SET/CLEAR button in that time,
all vanes are set to standard angle.
1
Set each vane angle by pressing up/down/left/right direction keys.
• Every time the button is pressed, corresponding vane angle and set
values are displayed.
• When up direction button is pressed, the display window appears as
of the figure in the right, and the angle can be set to 1~6.
2
20 Multi Air Conditioner
Maintenance and Service
Plasma filter
Deodorizer
filter
Removal of Filters
Open the front panel as shown.
Then pull the filter tab slightly forward to remove the air filter.
After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.
Plasma filter
Front panel
Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and
unplug the power cord.
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.
Never use any of these
• Water hotter than 40°C(104°F). It may cause deformation and discoloration.
• Volatile substances. They may damage the surface of the air
conditioner.
Air Filters
The air filters behind the front panel / grill should be checked and
cleaned once in every 2 weeks or more often if necessary. To remove
the filters see the self explanatory diagrams for each model type. Clean
the filters with a vacuum cleaner or warm soapy water. If dirt is not
easily removed, wash with a solution of detergent in luke warm water.
Dry well in shade after washing and reinstall the filters back in place.
Plasma Filters
The plasma filters behind the air filter should be checked and
cleaned once in every 3 months or more often if necessary. To
remove the filters see the self explanatory diagrams for each
model type. Clean the filters with a vacuum cleaner. If it is dirty
wash it with water and dry well in shade an install back in place.
Deodorizer Filters or Allergy Free Filter +
Triple Filter
Remove the deodorizer filters or allergy free filter + triple filter
behind the air filter and expose them in direct sunlight for 2 hours.
And then insert these filters into original position.
P
o
w
d
e
r
[Artcool Mirror Type]
[Standard Type]
Standard/Standard Libero/Artcool Mirror Type
Maintenance and Service
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67

LG LMAN125HV Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues