Velleman HAA2801 Guide d'installation

Catégorie
Pavés numériques
Taper
Guide d'installation
HAA2801
Programming & Installation Manual
FOR ELECTRIC LOCK, INTER-LOCK
AND SECURITY SYSTEM INSTALLATIONS
SPLIT-DECODED CONTROLLER
FOR HAA28XX SERIES SECURITY KEYPADS
VERSION: 11/2012
TABLE OF CONTENTS
INTRODUCTION
FEATURES
SPECIFICATIONS
PACKAGE CONTENTS
THE SPLIT-DECODED CONTROLLER UNIT (Figure 1)
THE MAIN CIRCUIT BOARD OF THE CONTROLLER --- (Figure 2)
INSTALLATION
Precautions
Split-Decoded Mode -- (For HAA2800 & HAA2801)
The Necessary Connections For Split-Decoded
The Function Mode Jumper Setting For Split-Decoded -- (HAA2800 Only)
The Link-Up Jumper & Link-Up Code Acquisition
The Function Mode Jumper -- (Available On HAA2800 Only)
CONNECTION TERMINALS
The Audible & Visible Signals
The Alarm Outputs & Warnings
RF Remote Controller -- (HAA2800 Only)
Stand Alone Mode -- (HAA2800 Only)
APPLICATION EXAMPLES
Basic Wirings of A Split-Decoded Door Lock
Basic Wirings of An Inter-Lock System Using Two Split-Decoded Keypads
APPLICATION HINTS FOR THE AUXILIARY TERMINALS
PROGRAMMING FOR FULL FEATURES --- (Supplementary Information)
Set System in Programming Mode with The Master Code
Direct Access to Programming Mode with The “DAP” Code – 8 0 8 0
Refresh The System with The “Refreshing Code” --- 9 9 9 9
The Default Values of The Keypad
FEATURE PROGRAMMING -- KEY IN AND STORE THE DESIRED VALUES
Programming Criteria for Codes
Record A Master Code
Record A Super User PIN
Operation And Functions of The Super User PIN
Record The Common User PINs for Output 1, 2 & 3
Record-Delete PINs or Cards for Output 1, 2, & 3
Examples – Programming And Operation
Visitor Codes (For Output 1 Only)
Duress Codes (For Outputs 1, 2 & 3)
The Operation And Function of The Duress Code
Conguration of The Output Modes for Output 1, 2 And 3
Personal Safety And System Lock-Out
2
...................................................................................
4
........................................................................................
4
.................................................................................
5
.............................................................................
5
...............................................
6
....................................6
....................................................................................
7
......................................................................................
7
...................................................
7
.....................................................
8
..............................8
....................................................8
..........................................9
.......................................................................
10
....................................................................
14
...................................................................
14
..........................................................
15
.............................................................
15
.......................................................................
16
.......................................................
16
...........................
17
..........................................
18
...........................
21
..........................................
21
................................
22
........................................
23
...............................................................
23
.........................
24
..................................................................
24
..........................................................................
25
.......................................................................
25
..................................................
26
...............................................
26
..................................................
27
.......................................................
28
................................................................
30
............................................................
31
.................................................
32
...........................................
33
............................................................
33
3
User PIN Entry Mode
Pacier Tones On-Off Selection
Output Operation Announcer
Status LED Flashing On-Off during Standby
Door Forced Open Warning & Timing
Door Propped-Up Warning & The Delay Time
Intelligent Egress Button – An Unique Feature of A Contemporary Keypad
Where And Why “Going Out” Needs Attention
Egress Delay, Warning And Alarm
Congurations of The Egress Warning And Alarm
Door Opening Alarm & Timer
Close The Programming Mode
The Operation Modes and The Wiegand Output
Wiegand Output at Keypad Operation Mode
PROGRAMMING SUMMARY CHART --- (Supplementary Information)
............................................................................
34
..................................................................
34
.....................................................................
34
.......................................................
35
.............................................................35
.....................................................
35
...........................
36
...................................................
36
...............................................................
37
...............................................
37
.....................................................................
38
...................................................................
38
...................................................
39
....................................................
39
..............................
40
INTRODUCTION
The HAA2801 is a self-contained access controller. It has been designed mainly as the decoder
unit working together with the HAA2866 and HAA2890 keypads to make up a split-decoded keypad
system.
In split-decoded operation the system provides full Tri-Tech features of accepting EM Card, PIN/Code
and RF Remote Control. This unique design philosophy makes the system to provide high level of
security in preventing sabotage far ahead of the traditional stand alone keypad systems.
Note: This manual describes both HAA2800 and HAA2801, but only HAA2801 is supported.
Please disregard all information regarding HAA2800 (stand-alone mode without keypad, RF remote
controller use).
HAA2801 is the simplied version. It is solely a full feature decoder of the HAA28xx series keypad in
Split-decoded operation.
The HAA2801 has three output relays and a built-in door chime. It is an ideal device for Door Strike,
Alarm Arm-disarm control and actuation of Automatic Operator, such as garage door opener.
The keypad system with the HAA2801 decoder in Split-decoded operation offers full features
performance even the keypad is just a simplied version. Maximum three keypads can be connected
in parallel to the decoder unit with one of them setting in master mode and the other two setting in
slave mode. Each keypad can be programmed with its own PINs and Cards. The slave keypads take
the features and the functions programmed in the master keypad to operate the system. The decoder
interprets the data and operates the desired functions faithfully.
For more info concerning this product and the latest version of this manual, please visit our
website www.velleman.eu. The information in this manual is subject to change without prior
notice.
FEATURES
HAA2800 – Full Feature Decoder + RF Remote Control
HAA2801 – Full Feature Decoder
I) HAA2800 & HAA2801
A Decoder for The HAA28xx Series Keypads in Split-decoded Operation
Decodes The Data of EM Cards, PINs / Codes & Functions Faithfully from Keypads
Provides Full Features in Split-Decoded Mode for Any Keypad in The HAA28xx Series
Simple Three Wires Connection to Keypads For Data Communication, (+), (
-
) & Data I/O
Easily to Set Up Link Up Code with The Keypads And The Decoder
Three Independently Controlled Output Relays
Built-in Door Chime
Built-in Alarm for Tamper, Door Forced Open and Door Opening in Split-Decoder Mode
Built-in Current Limited (750mA) Power Source for The Keypads to Prevent Sabotage of Short
Circuit from Outside
II) HAA2800 Only
Provides The Tri-Tech Features of RF Remote Control, Card and PIN/Code Reading in One
System
24 bits Self-learning Codes (over 1 million codes) for The RF Remote Control Keys
Accepts 40 RF Remote Control Keys Maximum
4 RF Remote Control Channels for Stand Alone or Split-decoded Operation
Remote Control Key Controls Output 1, 2, 3 & Door Chime
4
User manual only available in English. Mode d’emploi disponible uniquement en anglais.
SPECIFICATIONS
Operating Voltage:
12V-24V DC, Auto Adjusting
Operating Current:
65mA (quiescent) to 100mA (three relays active)
Operating Temperature:
-20 C to +70 C
Environmental Humidity:
5-95% relative humidity non-condensing
The Adjustable Timer for Output 1:
1-30 Seconds
Power Up Delay:
5 Seconds
Tamper Alarm:
3 Minutes
Input Sensing Terminals:
a) Door position, b) Egress, c) O/P 1 Inhibit, d) Door Bell, e) Tamper
Output Control Terminals:
a) Duress, b) Alarm, c) Key Active, d) Inter-lock;
Transistor Open Collector, 24VDC/100mA sink Max
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Output Relay 3 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Dimensions:
32.5(H) X 120(W) X 87(D)mm Plastic Box
Weight:
250g net
RF Remote Controller (HAA2800 Only) :
Number of Self-leaning Codes : Over 1 Million
Number of RF Control Keys : 40 Maximum
4 Control Channels : Output 1, 2, 3 & Door Chime
Operation Frequency : 433MHz
Control Distance : 60 Meters Approx. in Open Space
Receiver Type : Super-heterodyne
Operation Voltage : 12V Alkaline Battery, Type 27A (Battery Not Included)
Weight : 32g
Specications are subject to change for modication without notice
PACKAGE CONTENTS
One Access Controller
One Pack of Mounting Screws
Two RF Remote Control Keyfobs (HAA2800 Only), Battery Not Included
One Owner’s Manual
5
THE SPLIT-DECODED CONTROLLER UNIT (Figure 1)
THE MAIN CIRCUIT BOARD OF THE CONTROLLER --- (Figure 2)
NOTE:
Factory suggest that the work of timer adjustment and change of jumper settings on the
main circuit board are to be done by the Installer only.No adjustment/setting change is required for
Split-decoded operation with the ex-factory settings.
6
LINK-UP
JUMPER
OFF-->ON--
>OFF
CODE
LEARNING
BUTTON
(
HAA2800 ONLY
)
REMOTE
CONTROL
SIGNAL &
STATUS
(
HAA2800 ONLY
)
INTERNAL
SIREN
& DOOR CHIME
CONNECTION
TERMINALS
MAINS
OUTPUT BEEP
JUMPER ON OR
OFF
FUNCTION MODE
JUMPER
1. SPLIT-DECODED
2. STAND ALONE
MODE 1
3. STAND ALONE
MODE 2
ADJUSTABLE TIMER
FOR OUTPUT 1
TURN CLOCKWISE
FOR MAXIMUM TIME
RECEIVER FOR
REMOTE CONTROL
(HAA2800 ONLY)
INSTALLATION
PRECAUTIONS
1) Installation Location:
The built-in receiver of the Access Controller is working at the UHF frequency band of 433Mhz. To
get the best receiving result of the signals from the remote keys a correct installation location is
necessary.
i) Install it on a location inside the house facing to the open space and there has no strong electro-
magnetic wave signals near it.
ii) Do not install it in a concrete room or under a concrete stair, which shortens the control distance.
2) Prevent Accidental Short Circuit:
In the previous experience, most of the damages caused in the installation are accidental touching
of the components on circuit board with the wires carrying power. Please be patient in the
installation. Study the manual to become familiar with the specications of the system beforehand is
also important.
i) Do not apply power to the system while it is in installation.
ii) Check carefully all the wirings are correct before applying power to the system for testing.
SPLIT-DECODED MODE -- (for HAA2800 & HAA2801)
Split-decoded Mode needs at least one keypad to work with the decoder. The decoder decodes all the
commands from the keypad to operate its outputs. It is an unique solution to immediately up-grade
a general purpose keypad to a high security access control system. All the keypads in the HAA28xx
Series with Data I/O Port are compatible with the decoder. A Split-decoded system divides itself into
the outside keypad unit and the inside decoder unit. Any sabotage to the outside unit does not affect
the security of the inside unit.
7
RF WIRELESS
REMOTE CONTROL (DA-2800 ONLY)
DOOR LOCK
(OUTPUT 1)
SECURITY
SYSTEM (OUTPUT 2)
AUTOMATIC
OPERATOR (OUTPUT 3)
COMMON
GROUND
COMMON
GROUND
DA-2800 OR DA-2801
SLAVE 1
SLAVE 2
MASTER
DATA I/O
COMMON
GROUND
DATA I/O
DATA I/O
MAXIMUM 3 KEYPADS CAN BE CONNECTED IN PARALLEL
THE NECESSARY CONNECTIONS FOR SPLIT-DECODED
1)
2)
3)
4)
THE FUNCTION MODE JUMPER SETTING FOR SPLIT-DECODED -- (HAA2800 ONLY)
NOTE: No Function Jumper setting is required for the HAA2801. It is xed in Split-Decoder
mode.
1) Put the “Function Mode Jumper” to position “1” for Split-Decoder. (It is an Ex-factory Setting)
a)
b)
2) Set the “Link-up Jumper” from OFF to ON position to enable the link-up of acquiring the link-up
code from the keypad (same as the Master Code of the keypad).
a)
b)
c)
Remark:
a)
b)
c)
d)
THE LINK-UP JUMPER & LINK-UP CODE ACQUISITION
To acquire the link-up code (same as the Master Code) from the Master keypad for Split-Decoded
operation is necessary. At any time, when you operate a new Master keypad at the rst time it is
necessary to let the decoder unit to know the Master Code of the keypad. Otherwise, the decoder can
not recognize the data from it. If more than one keypads are going to link up with the decoder, all the
keypads are required to have the same Master Code and repeat link-up is not necessary.
The decoder executes Link-up Acquisition Only Once at the moment after setting of the Master
Keypad to exit Programming Mode with
**
.
8
Connect the Data I/O ports of the Decoder (Terminal 4) and the Keypad with wire to link-up the
communication of the two units.
Connect the Keypad PWR terminal of the Decoder (Terminal 3) to the keypad power input terminal,
which supplies power to the keypad unit with current limit protection.
Connect the Common (
-
) Ground (Terminal 2 or 11) to the (
-
) ground of the keypad unit to make
up the return path for the data and the power source.
Make all other installation connections to the decoder unit, but not to the keypad unit in Split-
Decoded Mode. The system provides full feature from the decoder unit according to the functions
programmed in the keypad.
The Function Jumper of the HAA2800 has been put on Position 1 at the factory. Setting of the
jumper is usually not necessary unless it has been changed. Always put jumper on position “1”
for Split-decoded mode.
The Function Jumper is located on the Main Circuit Board inside the box. Change the setting for
Stand Alone mode is required. See Figure 2.
The Jumper is located on the main circuit board inside the terminal compartment. See Figure1.
The Decoder executes link-up Only Once. The Link-up execution is done when the keypad exits
from Programming Mode after pressing
**
. Put the jumper back to OFF position after link up.
After the decoder knows the link-up code (Master Code) of the keypad it is not necessary to
repeat the link-up procedure in feature change programming except change of the Master Code.
All the keypads going to link up with the decoder MUST be with the same Master Code which is
the authorization code to enable the data communication between the keypads and the decoder.
It is not necessary to repeat the link-up procedures for the slave keypads with the same Master
Code. Just simply connect them in parallel with the master keypad.
The decoder will refuse other keypads that are not in the same Master Code to link up with it.
The failed keypads in the link-up will generate warning beeps.
9
Example – Change of the Link-up Code ( The Master Code of the Master Keypad)
a) Put the Link-up Jumper of the Decoder from OFF to ON
OFF ON
b) Set the Master Keypad to Programming Mode
EXISTING MASTER CODE
*
*
c) Set a New Master Code to the Master Keypad
NEW MASTER CODE #
d) Set the Master Keypad to exit from Programming Mode
*
*
e) The Link-up in the system is done automatically
BEEP BEEP ----- From Keypad
f) Put the Jumper back to OFF
ON OFF
g) The system is in Split-decoded operation with the new Link-up Code
THE FUNCTION MODE JUMPER -- (AVAILABLE ON HAA2800 ONLY)
Three positions are available for the Function Mode Jumper. Position 1 is for Split-decoded Mode and
the positions 2 & 3 are for Stand Alone Modes.
POSITION 1 – SPLIT-DECODER (MAINS LED LAMP FLASHING)
Position 1 is for Split-decoder mode. All the functions and the 3 output relay operation manners follow
the programmed settings in the Master keypad. All the functions of the decoder are programmable
from the keypad unit. The HAA2800 system is controlled by the keypads and the remote control keys
in the Split-decoded mode.
POSITION 2 – STAND ALONE MODE 1 – START / STOP FOR OUTPUT 1 (MAINS LED LAMP ON)
Position 2 is one of the settings for Stand Alone mode. All the three Output Relays are controlled by
the RF Remote Key with the following functions:
Output 1 – Start / Stop
Output 2 – Start / Stop
Output 3 – Manual Momentary
POSITION 3 – STAND ALONE MODE 2 – ADJUSTABLE TIMER FOR OUTPUT 1 (MAINS LED
LAMP ON)
Position 3 is one of the settings for Stand Alone mode. All the three Output Relays are controlled by
the RF Remote Key with the following functions:
Output 1 – Adjustable Timer
Output 2 – Start / Stop –––––––
Output 3 – Manual Momentary
Controlled by Channel 1 of the RF remote key. Press the Button A once to
start and press the button once again to stop.
Controlled by Channel 2 of the RF remote key. Press the Button B once to
start and press the button once again to stop.
Controlled by Channel 3 of the RF remote key. The output relay
operates (Starts) as long as the Button C is pressed and it stops
when the button is released.
Controlled by Channel 1 of the RF remote key. Press the Button A
once to start the timer and it resets automatically after time out. It is
adjustable 1-30 seconds. It is convenient for setting the time for door
strike. Turn the timer clockwise for maximum time. See Figure 2.
Controlled by Channel 2 of the RF remote key. Press the Button B
once to start and press the button once again to stop.
Controlled by Channel 3 of the RF remote key. The output relay
operates (Starts) as long as the Button C on the remote key is
pressed and it stops when the button is released.
10
CONNECTION TERMINALS
NOTE:
DRY CONTACT
A dry contact means that no electricity is connected to it. It is prepared for free connections.
N.C.
Normally Closed, the contact is closed circuit at normal state. It is open circuit when active.
N.O.
Normally Open, the contact is open circuit at normal state. It is closed circuit when active.
TRANSISTOR OPEN COLLECTOR OUTPUT
An open collector output is equivalent to a Normally Open (N.O.) contact referring to ground similar
to a relay contact referring to ground. The transistor is normally OFF, and its output switches to
ground (
-
) when active. The open collector can only provide switching function for small power but
it is usually good enough for controlling of an alarm system. The maximum rating is 24V DC/100mA
Sink
OPEN COLLECTOR
OUTPUT ----
Output switches to
ground when activated
N.O. CONTACT
OUTPUT ----
Output switches to
ground when activated
EQUIVALENT
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
1A RELAY DRY CONTACTS
FOR AUXILIARY CONTROL
5A RELAY DRY CONTACTS
FOR DOOR STRIKE
OPEN COLLECTOR OUTPUT
OPEN COLLECTOR OUTPUT
INPUT/OUTPUT FOR SPLIT-DECODED SIGNALS
POWER OUTPUT FOR KEYPADS
COMMON GROUND
POWER INPUT FOR SYSTEM
N.C. SW
COMMON GROUND
N.C. SW
N.O. SW
N.O. SW
N.O. SW
OUTPUT 1O UTPUT 2O UTPUT 3
1 - 2 : 12-24V DC I/P -- (Power Input Terminal)
Connect to a 12-24V DC power supply. The (
-
) supply and the (
-
) GND are the common grounding
points of the system. The system accepts full input voltage range.
3 : KEYPAD POWER O/P -- (Power Output for External Keypads – 500mA Max.)
This power source is prepared for the external keypad(s). Its output voltage follows to the input
voltage at terminals 1 - 2 but the output current is limited to 500mA only. This output terminal is
protected by a 500mA reset-able fuse to prevent sabotage to the internal power supply of the
system with short circuit from the external keypad.
4 : DATA I/O PORT -- (Data Input/Output Port for Split-Decoded Operation)
Connect this terminal with the Data I/O wire from the wire harness on the keypad unit to link up
system for Split-Decoded operation. Maximum 3 keypads can be connected in parallel to this
terminal.
Note:
Leave this terminal open if the controller is in Stand Alone operation. (Stand Alone operation is one
of the operation modes of the HAA2800)
5 : EG IN -- ( Egress Input)
A Normally Open (N.O.) input terminal referring to (
-
) ground. With the help of a normally open
button to activate Output 1 for door open in the same manner of using the User PINs or Cards
on keypad in Split-decoded mode; OR follows the Function Mode jumper setting of Start/Stop or
Momentary in Stand Alone mode.
Egress button is usually put inside the house near the door for exit convenience. More than one
egress buttons can be connected in parallel to this terminal. Leave this terminal open if not used.
6 : DOOR BELL I/P -- (Door Bell Button Input)
A terminal prepared for the connection of a normally open (N.O.) button referring to (
-
) ground to
activate the built-in door chime. More than one door bell buttons can be connected in parallel to this
terminal. Leave this terminal open if not used.
7 : DU OUT -- (Duress Output) – Available on Split-decoded Mode Only
An NPN transistor open collector output with the maximum power rating of 24VDC/100mA sink. It
is equivalent to an N.O. (Normally Open) terminal switching to (
-
) ground after the entry of Duress
Code. Use it to trigger an alarm zone of a security system, or turn on a buzzer to notify a guard.
Please see the application hints for more information.
Duress Function is available only on Split-decoded mode with Duress Code programmed from
keypad.
8 : INTER-LOCK O/P -- (Inter-lock Control Output)
An NPN transistor open collector output with the maximum power rating of 24VDC/100mA sink. It is
OFF at normal condition. It switches to (
-
) ground immediately for the rst 5 seconds after received
an operation command for Output 1 or after keying in a valid User PIN or reading a Card to operate
Output 1. It keeps tying to (
-
) ground during the Door Position Sensor is open circuit due to door
open. Use this output point to make cross wire connection with the associated controller’s “O/P 1
Inhibit” point in an Inter-lock system to prevent both doors that can be opened at the same time.
An Inter-lock System:
An inter-lock system is a two-door system that always allows only one of the doors to open during
the operation. While one of the doors is opened, the other door keeps close until the open door is
re-closed. It prevents the unauthorized people dashing into a protected area.
An inter-lock system needs two keypads or controllers and two door position sensing switches for
the two doors. Please see the Application Example for more information
9 : O/P 1 INHIBIT -- (Output 1 Inhibit Control Input – Normally Open)
A Normally Open (N.O.) sensing input point for controlling of the Output 1, with this terminal
connecting to (
-
) ground, the Egress Button and the whole group of Users (PINs & Cards) for
Output 1 are disabled. It is prepared mainly for the cross wire connection with the “Inter-lock O/P”
point on the associated controller in an Inter-lock system. The inhibit function also governs the RF
remote control key from operating of the Output 1 (if the decoder is HAA2800).
11
12
10 : DOOR SENS N.C. -- (Door Position Sensing Input -- Normally Close)
A Normally Closed (N.C.) sensing point referring to (
-
) ground, with the help of a normally closed
magnetic contact monitors the open or close state of the door. It initiates the following functions for
the system. Connect it with jumper to (
-
) Ground if not used.
a) Door Auto Re-lock
The system immediately re-locks the door after it is re-closed before the end of the programmed
time for output 1. It prevents unwanted “tailgate” entry.
b) Door Forced Open Warning (available in Split-decoded Mode only)
The controller generates “door forced open” warning and triggers alarm output instantly once
the door is forced to open without using a valid user PIN, Card or pressing of egress button. The
warning lasts as long as the time programmed (1-999 seconds). It can be stopped with the User
PIN or card for output 1 at anytime. See programming Location 80 of the keypad for the details.
c) Door Propped-up Warning (available in Split-decoded Mode only)
The controller generates propped-up warning beeps (does not activates alarm output) while the
door is left open longer than the allowable time programmed. The warning will last as long as the
door is open until it is re-closed. See programming Location 81 of the keypad for the details.
d) Inter-lock Control
The inter-lock control output always goes to (
-
) while the door is open, which gives signal to
disable the associated controller in the inter-lock system. See the Inter-lock terminal description
for more information.
e) Door Opening Alarm (available in Split-decoded Mode only)
Door Opening Alarm is designed for the emergency door only. It is always given when the door is
opened unless a valid User Code or Card is used prior to the door is opened. See programming
Location 91 of the keypad for the details.
11 : (
-
) GND -- (Common Ground of The System)
A grounding point of the keypad that is common to terminal 2.
12 : TAMPER IN -- (Tamper Switch – Normally Closed Input Terminal)
A Normally Closed (N.C.) input terminal referring to (
-
) ground. It is prepared for the tamper switch
of the keypad connecting to it. When the tamper switch is open circuit it triggers the internal siren
and the Alarm Output terminal. Link up this terminal to (
-
) Ground with jumper if not used.
The alarm lasts for 3 minute in stand alone mode. It is reset-able before expiry with User Code from
keypad in Split-decoded mode.
13 - 14 - 15 : OUTPUT 1 -- (Output Relay 1)
5 Amp relay dry contact controlled by the Group 1 User PINs & Cards in Split-decoded mode or by
the RF remote key in Stand Alone mode. It is recommended for door strike. Terminal 13 is Normally
Closed contact (N.C.), terminal 15 is Normally Open contact (N.O.) and terminal 14 is the common
point of the two contacts. Use N.C. output for Fail-safe locking device; and N.O. output for Fail-
secure locking device.
(a) The operation of Output 1 is programmable from the keypad in Split-decoded operation (with
Function Jumper on position 1). See programming Location 51 of the keypad for the details.
(b) The Output 1 is selectable for Start/Stop (toggle) mode (with Function Jumper on position 2) or
Adjustable Momentary Timer mode (with Function Jumper on position 3) in Stand Alone mode.
The Adjustable Timer (1-30 seconds) is located on the main circuit board inside the box. See Figure 2.
16 - 17 - 18 : OUTPUT 2 -- (Output Relay 2)
1 Amp relay dry contact controlled by the Group 2 User PINs & Cards in Split-decoded mode or by
the RF remote key in Stand Alone mode. It is an auxiliary output ideally for controlling of security
system or automatic operator. Terminal 16 is Normally Closed contact (N.C.), terminal 18 is Normally
Open contact (N.O.) and terminal 17 is the common point of the two contacts.
(a) The operation of Output 2 is programmable from the keypad in Split-decoded operation (with
Function Jumper on position 1). See programming Location 52 of the keypad for the details.
(b) The Output 2 is always xed on Start/Stop (toggle) operation with Function Jumper on position 2
or 3 in Stand Alone mode.
13
19 - 20 - 21 : OUTPUT 3 -- (Output Relay 3)
1 Amp relay dry contact controlled by the Group 3 User PINs & Cards in Split-decoded mode or by
the RF remote key in Stand Alone mode. It is an auxiliary output ideally for controlling of security
system or automatic operator. Terminal 19 is Normally Closed contact (N.C.), terminal 21 is Normally
Open contact (N.O.) and terminal 20 is the common point of the two contacts.
(a) The operation of Output 3 is programmable from the keypad in Split-decoded operation (with
Function Jumper on position 1). See programming Location 53 of the keypad for the details.
(b) The Output 3 is always xed on Manual Momentary operation with Function Jumper on position
2 or 3 in Stand Alone mode. Manual Momentary means that the relay output works as long as
the button of the RF remote key is pressed. The relay output is released when the key button is
released.
22 : KEY ACT O/P -- (Keypad Active Output)
An NPN transistor open collector output with the maximum power rating of 24VDC/100mA sink. It
is equivalent to an N.O. (Normally Open) terminal referring to ground. It switches to (
-
) ground for
10 seconds on each key touch on the keypad or receiving of a command signal from the RF remote
key. It can be used to drive a small power device, such as a relay or a low power control point of
other equipment. See the Application Hints for more information.
23 : ALARM O/P -- (Alarm Output)
An NPN transistor open collector output with the maximum power rating of 24VDC/100mA sink. It is
equivalent to an N.O. (Normally Open) terminal referring to ground. It switches to (
-
) ground while
alarm occurs in order to trigger an external alarm to give notication at remote location. Use it to
drive a small power device, such as a relay or a low power control point of other equipment.
The Alarm Output for tamper is 3 minutes xed. Other alarm outputs are programmable in Split-
decoded operation.
THE OUTPUT BEEP JUMPER
The controller gives beep sound when the relay output activates in stand alone mode or when
a command signal from the RF remote key is received. The beep jumper has been put on the
ON position at the factory. It can be stopped for silent environment by putting the jumper to OFF
position. The Jumper is located on the main circuit board. See Figure 2.
14
THE AUDIBLE AND VISIBLE SIGNALS
STATUS AUDIBLE SIGNALS MAINS LED SIGNALS
1) Power-up Delay (5 Seconds) Continuous Beeps Continuous Fast Flashes
2) Power-up Delay (1 Minute)* Continuous Beeps Continuous Fast Flashes
3) System In Standby Mode OFF 1 Flash / Second
4) System In Standby Mode* OFF ON
5) Keypad In Programming Mode OFF 1 Flash / Second
6) Successful Command from RF Key 2 Beeps 2 Flashes
7) Output Relay Active (From Keypad) 1 Long Beep or 2 Short Beeps No Signal
8) Egress Delay Warning Fast Beeps Nil
9) Door Forced Open Warning Fast Beeps + Alarm Output Nil
10) Door Propped-up Warning Fast Beeps Only Nil
11) Alarm Output Warble Tone Siren Nil
12) Door Chime Dual Tone Door Chime Nil
* Stand Alone Mode
THE ALARM OUTPUTS & WARNINGS
1) Tamper Alarm:
a) The alarm is triggered via the “Tamper In” terminal
b) Alarm Output and Internal Siren activate
c) The alarm period is xed in 3 minutes for Stand Alone Mode
d) It can be reset with Super User Code # 1 or an user Code/Card in Group 1 in Split-decoded
Mode
The Following Alarm & Warning Are Available in Split-decoded Operation Mode Only
2) Egress Delay Alarm:
a) The Egress Delay Alarm is enabled by programming from keypad at Programming Location 90
b) The alarm activates during the Egress Delay period and it stops at the expiry of the Egress Delay
c) Alarm Output and Internal Siren activate
3) Egress Delay Warning:
a) The Egress Delay Warning is enabled by programming from keypad at Programming Location 90
b) The warning activates during the Egress Delay period and it stops at the expiry of the Egress Delay
c) The warning beep is given by the internal buzzer only
4) Door Open Alarm (Designed for Emergency Door):
a) The Door Open Alarm is enabled by programming from keypad at Programming Location 91
b) Alarm Output and Internal Siren activate
c) Alarm happens in door forced to open or normal open with Egress Button
d) No Alarm happens in door open with User PIN or Card
5) Door Forced Open Alarm:
a) The Door Forced Open Alarm is enabled by programming from keypad at Programming Location 80
b) Alarm Output and Internal Siren activate
c) Alarm happens in door forced to open only
d) No Alarm happens in door open with Egress Button, User PIN or Card
Note: If both alarms (4) & (5) are enabled in the programming, the system will take the longer one for
alarm time.
6) Door Propped-up Warning
a) The Door Propped-up Warning is enabled by programming from keypad at Programming Location 81
b) The warning starts at the expiry of the propped-up delay.
c) The warning beep is given by the internal buzzer only
15
RF REMOTE CONTROLLER -- (HAA2800 ONLY)
The HAA2800 RF Remote Controller consists of a built-in receiver and two remote control keys, which
has 4 channels to control the Output Relay 1, 2, 3 and the built-in door chime. Two remote keys are
supplied and up to 40 remote keys can be accommodated by the system. The receiver (decoder) of
the system learns the ID codes from the remote keys. Each remote key contains a 24-bit ID code
that provides over 1 million code combinations. The remote key gives around 60 Meters of controlling
distance in open space to the receiver.
(A) Procedure of Recording An RF Remote Key -- (Learning)
The RF remote keys that prepare to work with the decoder are required to be registered. The decoder
learns the ID of the remote keys one by one beforehand with the following procedures:
1)
2)
3)
4)
5)
(B) Procedure of Deleting The RF Remote Keys from Memory -- (Clearing)
If an RF remote key is lost it is necessary to delete it from the memory of the receiver. Every time the
system will clear all the ID Codes of the RF Remote Keys in the deletion. Re-learn the existing remote
keys are necessary.
1)
2)
(C) Operating The System with RF Remote Control Keys -- (Operation)
The system can be operated with the RF Remote Control Keys no matter it is in Split-decoded Mode
or in Standard Alone Mode. In the Split-decoded mode, the RF Remote Key operates the system
according to the functions and data that have been programmed with the digital keypad. While in Stand
Alone operation the system operates its outputs according to the functions that stated in the Stand
Alone Mode 1 or Mode 2.
1) Press button A to operate Output 1
2) Press button B to operate Output 2
3) Press button C to operate Output 3
4) Press button D to operate the built-in Door Chime
STAND ALONE MODE -- (HAA2800 ONLY)
The system that operates in Stand Alone mode does not require the keypad. It is directly controlled by
the RF Remote Key for the outputs. It is an ideal solution for the remote controls of door strike, alarm
arm-disarm, garage door opening etc.. The following settings are necessary while the system is in
stand alone operation:
1)
2)
3)
4)
Press and hold the LEARN button on the receiver unit for 1 second until the REMOTE LED turns
ON. (The button is inside the hole. Use a pin or the tip of a ball pen to reach it). See Figure 1
The decoder of the receiver is in Waiting Mode for 10 seconds waiting for the signal from the
Remote Key after the Remote LED turning ON.
Press any button of the RF Remote Key unit ONCE within the 10 seconds for the receiver to learn
the ID Code from it.
The REMOTE LED on the receiver unit turns OFF after the ID Code is learned.
Take the above learning procedures 1-4 for other RF Remote Keys
Press and hold the LEARN button on the receiver unit for 8 seconds (Remote LED turns ON) until
the REMOTE LED gives 2 ashes to conrm that all the data are erased. Then the LED turns
OFF.
Record the ID Code of the existing RF Remote Keys (not lost) into the memory again one by one
with the procedures stated in the “Recording An RF Remote Key”
Put the “Function Mode Jumper” to position “2” or “3” for the desired Stand Alone Operation
Mode. See the “Function Mode Jumper Setting” stated above for the details.
Always put “Link-up Jumper” on OFF position.
Leave the “Data I/O” port open without any connection.
Make all the installation connections to the terminals of the decoder unit.
16
APPLICATION EXAMPLES
1) BASIC WIRINGS OF A SPLIT-DECODED DOOR LOCK
NOTE:
Connect the 1N4004 as close as possible to the lock in parallel with the lock power terminals of the
lock to absorb the back EMF to prevent it from damaging the keypad. The 1N4004 is not required if
the electric lock is AC operated.
To avoid Electro-Static-Discharge from interfering with the operation of the keypad, always ground
the (
-
) terminal of the keypad to earth.
Always connect DOOR SENSOR terminal to (
-
) ground if not used.
Always connect TAMPER terminal to (
-
) ground if not used.
Make 3-wire Connection (+,
-
, DATA I/O) to the keypad in the HAA28xx Series. More than one
keypads can be connected in parallel.
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
CATHODE
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
MORE EGRESS
BUTTON CAN
BE CONNECTED
IN PARALLEL
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
(
-
)
N.O.
N.O.
17
2) BASIC WIRINGS OF AN INTER-LOCK SYSTEM USING TWO SPLIT-DECODED KEYPADS
An inter-lock system needs two door controllers. This application example uses two keypad systems
with simple cross wire connection on their "Output 1 Inhibit" and "Inter-lock Control Output" terminals.
It is necessary to link up the "(
-
) GND" terminals of the two keypads as common ground to achieve
the inter-lock logical functions.
Use keypad to open the door from outside
Press egress button to open the door from inside
Connect the door magnetic sensors on the doors to monitor their positions
While door 1 is open, then, door 2 is forced to keep close, or vice versa
Use N.O. Relay output for fail-secure lock; and N.C. output for fail-safe lock
Please also see the "NOTE" stated in the Application Example (1)
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
DOOR 1
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
N.O.
DOOR 1
SENSING
COMMON GROUND
(
-
)
DA-2800 OR DA-2801 DA-2800 OR DA-2801
CROSS WIRE CONNECTION FOR INTER-LOCK FUNCTIONS
-
ALARM O/P
-
KEY ACT O/P
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
N.O.
-
COM
-
N.C.
-
TAMPER
-
GND(
-
)
-
DOOR SENS
-
O/P 1 INHIB
-
INT. LOCK
-
DU OUT
-
DOOR BELL IN
-
EG IN
-
DATA I/O
-
KEYPAD PWR
-
GND(
-
)
-
12-24V DC
N.O.
ELECTRIC LOCK
1N4004
DOOR 2
OUTPUT RELAY 1
N.O. Output for Fail-secure Lock
N.C. Output for Fail-safe Lock
N.C.
OUTPUT 1 OUTPUT 2 OUTPUT 3
DIGITAL KEYPAD
AD-1312 OR AP-960
EGRESS BUTTON
DOOR BELL
BUTTON
N.O.
(
-
)
(
-
)
N.O.
DOOR 2
SENSING
APPLICATION HINTS FOR THE AUXILIARY TERMINALS
The tamper switch is Normally Closed while the
keypad is secured on the gang box. It is open
when the keypad is removed from the gang
box. To get warning at sabotage, connect the
tamper switch to the TAMPER terminal of the
HAA2800. If more than one tamper switches
are connected, just connect them in series.
With the help of a Normally Closed
door position sensor (usually a
magnetic door switch) on the door to
set up the following functions:
Door Auto Relock -- The system will
immediately relock the door after a valid access
has been gained to prevent "tailgate" entries.
Door Forced-open Alarm -- The keypad will
generate alarm instantly if the door is forced to
open. Enable the function at Location 80.
Door Propped-up Alarm -- The keypad will
generate alarm if the door is left open longer
than the pre-set delay time. Enable the function
at Location 81.
Inter-lock Control -- When the door is open,
the interlock output of the keypad will give a (
-
)
command to stop the other keypad in an inter-
lock system.
Door Opening Alarm -- Door Opening Alarm
is designed for the emergency door only. It is
always given when the door is opened unless a
valid user code or card is used prior to the door
is opened. Enable the function at Location 91.
a)
b)
c)
d)
e)
(A) TAMPER N.C.
(B) DOOR SENS
The Alarm Output switches to (
-
) ground in door forced to open or the door open after Egress
Delay. You may use it to turn ON an LED lamp and/ or a small buzzer to notify a guard; or
connect it to a 24 hour Normally Open protection zone of an alarm system. See Location 80 and
Location 91 for more information about these functions.
Only one connection option is recommended. Make sure that the sink current does not
exceed the maximum rating of 100mA.
(C) ALARM OUTPUT
GND(
-
)
N.C
TAMPER SWITCH
OF THE KEYPAD
GND(
-
)
DOOR
SENS
18
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
The Duress Output switches to (
-
) ground when duress code is entered. You may use it to turn
ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally
Open protection zone of an alarm system.
Only one connection option is recommended. Make sure that the sink current does not
exceed the maximum rating of 100mA.
(E) DURESS OUTPUT
The Key Active Output switches to (
-
) ground
for 10 seconds whenever a key is touched.
You may use it to turn ON an LED lamp and
/or a small buzzer to notify a guard; or to
energize a relay to switch ON lights or trigger
an CCTV Camera to start recording.
Make sure that the relay for switching ON
lights has high enough isolation between
high voltage and low voltage to prevent
damage of the keypad.
Only one connection option is recommended.
Make sure the sink current does not exceed
the maximum rating of 100mA.
External power supply and isolation relay
are strictly necessary in driving high power
device, such as lights.
(D) KEY ACTIVE OUTPUT
(a) (b)
GND
(
-
)
DOOR
SENS
O/P 1
INHIB
INT.
LOCK
DU
OUT
GND
(
-
)
DOOR
SENS
O/P 1
INHIB
INT.
LOCK
DU
OUT
19
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
ALARM
O/P
KEY ACT
O/P
GND
(
-
)
20
Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection
zone of an alarm system.
Set output contact to Start / Stop Mode (Programming Option 52, Output Mode=0).
Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.
Consult your alarm control panel manual for the appropriate output contact to be used in arm-
disarm control.
Usually set output 2 to Momentary mode (Programming Option 521, Location 52, Output
Mode=1) for multi station systems and Start / Stop mode (Programming Option 520, Location
52, Output Mode=0) for single station systems.
(F) OUTPUT 2 OR OUTPUT 3
( i ) Shunting an N.C. Zone
( ii ) Alarm System Arm-Disarm Control
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Velleman HAA2801 Guide d'installation

Catégorie
Pavés numériques
Taper
Guide d'installation

dans d''autres langues