iCH Prime
CPAP System
Instruction Manual
Model No.: 9S-007100 Please read the instruction manual before use.
User’s manual................................................................ P. 1
Manual de Instrucciones
..............................................
P.23
Instruções de Utilização
...............................................
P.48
Instructions d'utilisation............................................... P.73
Gebrauchsanleitung
.....................................................
P.99
Nederlands
Gebruikershandleiding ................................................. P.124
Italiano
Manuale di istruzioni ................................................... P.149
173
Italiano
Distanze di separazione consigliate tra dispositivi di
comunicazione RF portatili e mobili e questo dispositivo:
Questo dispositivo è stato progettato per l'uso in un ambiente elettromagnetico in cui le
interferenze RF sono controllate. Il cliente o l'utente di questo dispositivo può contribuire a
impedire interferenze elettromagnetiche rispettando una distanza minima tra i dispositivi
(trasmettitori) di comunicazione RF portatili e mobili e questo dispositivo, come consigliato di
seguito, in base alla potenza massima di trasmissione del dispositivo di comunicazione.
Distanza di separazione in base alla frequenza del trasmettitore m
Potenza massima di
trasmissione
indicata per il
trasmettitore W
150 kHz a 80 MHz
Pd 2.1=
80 MHz a 800 MHz
Pd 2.1=
Da 800 MHz a 2,5 GHz
Pd 3.2=
0,01 0,12 0,12 0,23
0,1 0,38 0,38 0,73
1 1,2 1,2 2,3
10 3,8 3,8 7,3
100 12 12 23
Per i trasmettitori la cui potenza massima di emissione non è indicata nell'elenco, la distanza
di separazione d consigliata in metri (m) può essere stimata utilizzando l'equazione
applicabile alla frequenza del trasmettitore, dove P rappresenta l'indice di potenza di
trasmissione massima del trasmettitore in Watt (W) secondo il produttore del trasmettitore.
Nota 1: A 80 MHz e 800 MHz, viene applicata la distanza di separazione per l'intervallo di
frequenza maggiore.
Nota 2: Queste regole non sono applicabili in tutte le situazioni. Sulla propagazione
elettromagnetica influiscono l'assorbimento e la riflessione di strutture, oggetti e
persone.
172
Italiano
di conformità per ciascun
intervallo di frequenza.
Si possono verificare
interferenze nei pressi dei
dispositivi contrassegnati dal
seguente simbolo:
NOTA 1 A 80 MHz e 800 MHz, viene applicato l'intervallo di frequenza maggiore.
NOTA 2 Queste regole non sono applicabili in tutte le situazioni. Sulla propagazione
elettromagnetica influiscono l'assorbimento e la riflessione di strutture, oggetti e persone.
a) Le bande ISM (industriale, scientifica e medica) tra 150 kHz e 80 MHz vanno da 6,765 MHz a
6,795 MHz; da 13,553 MHz a 13,567 MHz da 26,957 MHz a 27,283 MHz; e da 40,66 MHz a
40,70 MHz.
b) I livelli di conformità nelle bande di frequenza ISM tra 150 kHz e 80 MHz e nella gamma di
frequenza da 80 MH
z a 2,5 GHz sono stati studiati per diminuire la possibilità che i dispositivi di
comunicazione mobili/portatili possano generare delle interferenze se portati inavvertitamente in
zone in cui vi sono i pazienti. Per questo motivo si usa un fattore aggiuntivo di 10/3 nel calcolo
della distanza di separazione consigliata per i trasmettitori in questi intervalli di frequenza.
c)
Le intensità di campo dei trasmettitori fissi, quali stazioni fisse di radiotelefoni (cellulari/cordless)
e radio mobili terrestri, radi
oamatori, trasmissioni radio AM e FM e trasmissioni TV, non possono
essere previste teoricamente con precisione. Per valutare l'ambiente elettromagnetico
causato da trasmettitori RF fissi, è necessario prendere in considerazione un'indagine sul sito
elettromagnetico. Se l'intensità di campo misurata nel luogo d’impiego del dispositivo supera il
livello di conformità RF applicabile illustrato in precedenza, il dispositivo deve essere sottoposto
a osservazione per verificarne il funzionamento normale. Se si
riscontrano prestazioni anomale,
potrebbero essere necessarie ulteriori misure, ad esempio la modifica dell'orientamento o lo
spostamento del dispositivo.
d) Oltre all'intervallo di frequenza da 150 kHz a 80 MHz, le intensità di campo devono essere
inferiori a 3 V/m.
1
E
nglish
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING
WARNING –
1. THIS DEVICE IS NOT INTENDED FOR LIFE SUPPORT. It may stop operating due to power
interruption without hazard to patient.
2. If oxygen is used with the device, the oxygen flow must be turned off when the device is not in use.
Explanation of the Warning: When the device is not in operation and the oxygen flow is left on,
oxygen delivered into the tubing may accumulate within the device and create a risk of fire.
3. Oxygen is inflammable. Oxygen should not be used while smoking or in the presence of an open
flame.
4. Always ensure the device is generating airflow before the oxygen supply is turned on. Always turn
off the oxygen supply before stopping the airflow from the device.
5. This device should not be used in the vicinity of a flammable anaesthetic mixture in combination
with oxygen or air and nitrous oxide.
6. The airflow for breathing generated by this device may be as much as 7°C (12.6°F) higher than the
room temperature. This device should not be used if the room temperature is warmer than 35°C
(95°F) to prevent the airflow temperature from exceeding 40°C (104°F) and causing irritation to
your airway.
7. If this device overheats, it will stop operating and show message “Error 002” on the display. After
cooling down to the proper temperature, the device can be restarted.
8. This machine should be used only with masks (and connectors) recommended by the
manufacturer, or by your doctor or respiratory therapist. A mask should not be used unless the
CPAP machine is turned on and operating properly. The vent holes for the mask should never be
blocked, to allow for proper exhaling. If the vent hole is blocked, the CPAP machine will stop and
show message Error 002”. After the machine cools down, please re-connect the power cord to
reset the machine.
9. At low CPAP pressure, some exhaled gas may remain in the mask and bebreathed in again.
CAUTION –
1. Make sure the area around the machine is dry and clean. Dust and foreign particles may affect the
treatment. Keep the air inlet on the back of the machine clear to prevent overheating and damage
of the device. Do not place the machine near a source of hot or cold air. An extremely cold or hot
environment may damage the user's respiratory airway.
2. If there is a possibility of electro-magnetic interference with mobile phones, please increase the
distance between devices or turn off the mobile phone.
3. Do not connect the device to the personal computer for data downloading during the treatment.
This may cause a failure in the CPAP system.
4. To prevent from potential allergic reactions to mask used in the device, This machine shall be used
only with masks (and connectors) recommended by the manufacturer.
5. U.S. Federal law restricts this device to sale by or on the order of a licensed doctor.
2
E
nglish
DANGER -To reduce the risk of electrocution:
1. Always unplug this product immediately after using.
2. Do not use while bathing.
3. Do not place or store product where it can fall or be pulled into a tub or sink.
4. Do not place in or drop into water or other liquid.
5. Do not reach for a product that has fallen into water. Unplug immediately.
6. If product falls into water or other liquids do not reach into the water or other liquids. Unplug
immediately.
WARNING -To reduce the risk of burns, electrocution, fire or injury to persons:
1. This product should never be left unattended when plugged in.
2. Close supervision is necessary when this product is used with or near children or invalids. Choking
resulting from a child swallowing a small part that has become detached from the device or its
accessories.
3. Use this product only for its intended use as described in this manual, do not use attachments not
recommended by the manufacturer.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has
been dropped or damaged, or dropped into water. Return the product to a service centre for
examination and repair.
5. Keep the cord away from heated surfaces.
6. Never block the air openings of this product or place it on a soft surface, such as a bed or couch,
where the air openings may be blocked. Keep the air opening free of lint, hair, and other similar
particles.
7. Never drop or insert any object into any opening or hose.
8. Follow the national requirementfor disposing of the unit.
9. Do not operate the device before the mask and water chamber have been installed.
10. Disconnect the water chamber from the device when not in use, water entering the device may
result in electric shock hazard or damage.
11. Do not use if water comes in contact with the device or enters the tubing.
12. This device is not for use with patients whose supraglottic airways have been bypassed.
13. Do not cover the device with blankets or clothes .
14. Do not remove water chamber while humidifier is heating. Do not touch the heater plate for 30
minutes after the device is disconnected from the mains.
15. No modification of this equipment is allowed.
16. Do not modify this equipment without authorization of the manufacturer.
17. If this equipment is modified, appropriate inspection and testing must be conducted to ensure
continued safe use of the equipment.
18. Do not leave long lengths of air tubing around the top of your bed. It could twist around your head
or neck while you are sleeping and lead to strangulation.
171
Italiano
Campo magnetico della
frequenza di alimentazione
(50/60Hz)
IEC61000-4-8
3 A/m 3 A/m I campi magnetici della
frequenza di alimentazione
devono essere pari ai livelli
caratteristici di una sede tipica
in un ambiente commerciale o
ospedaliero comune.
NOTE: U
T
rappresenta la tensione dell'alimentazione c.a. prima dell'applicazione del livello di pro
va.
Guida e dichiarazione del produttore - Immunità elettromagnetica
Questo dispositivo è stato progettato per l'uso nell'ambiente elettromagnetico specificato di seguito.
L'utente di questo dispositivo si deve assicurare che venga utilizzato in un ambiente di questo tipo.
Test di immunità Livello del test
IEC60601
Conformità Ambiente elettromagnetico –
Guida
RF condotta IEC 61000-4-6
RF irradiata IEC 61000-4-3
3 Vrms da 150
kHz a
80 MHz fuori dalle
bande ICM
a
3 V/m
Da 80 MHz a
2,5 GHz
3 Vrms
3 V/m
I dispositivi di comunicazione a
radio frequenza portatili e
mobili devono essere utilizzati
lontano da qualsiasi parte di
questo dispositivo (compresi i
cavi), alla distanza di
separazione minima
consigliata, calcolata con
l'equazione applicabile alla
frequenza del trasmettitore.
Distanza di separazione
consigliata:
d
= 1,2P da 150kHz a 80MHz
d
= 1,2P da 150kHz a 80MHz
d = 2,3P da 80MHz a 2,5G
MHz
Dove P rappresenta l'indice di
potenza di trasmissione
massimo del trasmettitore in
Watt (W), secondo il produttore
del trasmettitore, e d
rappresenta la distanza di
separazione consigliata in metri
(m)
b
.
Le intensità di campo dei
trasmettitori RF fissi, in base a
una ricerca
sull'elettromagnetismo
c
,
devono essere inferiori al livello
170
Italiano
Appendice A: Informazioni sulla Compatibilità
Elettromagnetica
Guida e dichiarazione del produttore - Emissioni elettromagnetiche
Questo dispositivo è stato progettato per l'uso nell'ambiente elettromagnetico specificato di seguito.
L'utente di questo dispositivo si deve assicurare che venga utilizzato in un ambiente di questo tipo.
Test di emissioni Conformità Ambiente elettromagnetico – Guida
Emissioni armoniche
IEC61000-3-2
Classe A
Fluttuazioni della
tensione/ Em
issioni di
sfarfallii
IEC61000-3-3
Conforme
Il dispositivo è adatto all'utilizzo in tutti gli edifici,
compresi quelli destinati all'uso domestico e quelli
direttamente collegati alla rete pubblica di
alimentazione a basso voltaggio.
Guida e dichiarazione del produttore - Immunità elettromagnetica
Questo dispositivo è stato progettato per l'uso nell'ambiente elettromagnetico specificato di seguito.
L'utente di questo dispositivo si deve assicurare che venga utilizzato in un ambiente di questo tipo.
Test di immunità Test IEC60601 Conformità Livello elettromagnetico
Guida Ambiente
Scarica elettrostatica
(ESD) IEC61000-4-2
Contatto ±6kV
±8kV aria
Contatto ±6kV
±8kV aria
I pavimenti devono essere di
legno, cemento o piastrelle di
ceramica.
Se i pavimenti sono rivestiti con
materiale sintetico, l'umidità
relativa deve essere almeno
del 30%.
Transitorio elettrico rapido
/raffica
IEC61000-4-4
±2 kV per linea di
alimentazione
±1 kV per linea di
entrata/uscita
±2 kV per linea di
alimentazione
±1 kV per linea di
entrata/uscita
La qualità della potenza della
rete deve essere quella di un
tipico ambiente commerciale o
ospedaliero.
Sovratensione
IEC61000-4-5
±1 kV per modalità
differenziale
±2kV per modalità
comune
±1 kV per modalità
differenziale
±2kV per modalità
comune
La qualità della potenza della
rete deve essere quella di un
tipico ambiente commerciale o
ospedaliero.
Cali di tensione, brevi e
sbalzi di tensione nelle
linee di entrata
dell’alimentazione
IEC61000-4-11
<5 % di U
T
(>95%
di calo in U
T
) per
0,5 interruzioni
40% di U
T
(60% di
in UT) per 5 cicli
70% di U
T
(30% di
calo in U
T
) per 25
cicli <5% U
T
(>95%
di calo in U
T
) per 5
sec.
<5% di U
T
(>95% di
calo in UT) per 0,5
interruzioni 40% di
U
T
(60% di in U
T
)
per 5 cicli
70% di U
T
(30% di
calo in U
T
) per 25
cicli <5% U
T
(>95%
di calo in U
T
) per 5
sec.
La qualità della potenza della
rete deve essere quella di un
tipico ambiente commerciale o
ospedaliero.
Se l'utente di questo disp
ositivo
ha bisogno di un utilizzo
continuo anche durante un
blackout, è consigliabile
alimentare il dispositivo tramite
un gruppo di continuità o una
batteria.
3
E
nglish
1. Introduction
This manual should be used for initial set up of the system and saved for reference purpose.
1.1 General Information
Obstructive Sleep Apnea (OSA) is a condition that an intermitted and repetitive obstruction of the
upper respiratory tract causes a complete (apnea) or partial (hypopnea) block of breathing airflow
during sleep. The syndrome varies depending on the degree of relaxation of the tongue and soft
palate muscle.
The most common treatment for OSA is Continuous Positive Airway Pressure (CPAP). CPAP
devices can deliver a constant air pressure into your upper airway via a nasal mask. This constant
air pressure can keep your airway open during sleep, therefore prevents the OSA.
This device is a micro-processor controlled continuous positive airway pressure device. It features
the illuminated, menu-driven LCD display, universal power supply and ramp time adjustment. The
ramp time adjustment and ultra quiet operation ensure you to fall asleep comfortably while air
pressure slowly builds up to treatment level. The user compliance meter records the total
system’s operating time for physician’s reference.
The system has been tested and successfully approved to the following standards:
EN 60601-1
EN 60601-1-2
EN 61000-3-2 Class A
EN 61000-3-3
For US and CANADA only
Le produit à été testé avec des équipements médicaux et respecte les normes UL 60601-1 & CAN/CSA C22.2
No.601.1. prévenant les choc électrique, le feu et les risques de blessures physiques.
E348970
53DG
Medical Equipment- CPAP with integrated heated humidifier
WITH RESPECT TO ELECTRICAL SHOCK,
FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH ANSI/AAMI
ES60601-1 (2005,3rd ed.) and CAN / CSA C22.2 No.
60601-1 (2008, 3
rd
ed.) and IEC 60601-1-11
4
E
nglish
EMC Warning Statement
This equipment has been tested and found to comply with the limits for medical devices to the
EN 60601-1-2:2007. These limits are designed to provide reasonable protection against harmful
interference in a typical medical installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to other devices in the vicinity. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to other devices, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment to an outlet on a circuit different from that to which the other device(s) are
connected.
- Consult the manufacturer or field service technician for help.
This system has been tested for compliance to the following volunteer standards:
FDA
1.2 Intended Use
This device is intended to provide continuous positive airway pressure (CPAP) for the treatment of
adult Obstructive Sleep Apnea (OSA). The integrated heated humidifier is designed to increase
the humidity of the air from the CPAP thereby relieving the symptoms of a dry nose and throat that
some people may experience.
Cautions: Some patients might have pre-existing contraindications for CPAP therapy,
or might experience some potential side effects of using a CPAP device.
Please consult your doctor if you have any questions concerning your
therapy.
NOTE: Equipment not suitable for use in the presence of a flammable anaesthetic
mixture with air or with oxygen or nitrous oxide.
169
Italiano
9. Assistenza tecnica
I sistemi della serie iCH sono stati progettati per un funzionamento sicuro e affidabile
conformemente alle istruzioni fornite da APEX Medical. Se si riscontrassero tracce di usura o
problemi con il funzionamento dell'apparecchio, APEX Medical consiglia di fare controllare e
riparare il sistema iCH esclusivamente da tecnici autorizzati. Tuttavia, non dovrebbe essere
necessario controllare e riparare gli apparecchi entro i primi cinque anni di vita utile.
10. Garanzia limitata
Apex Medical Corp. (in seguito ‘Apex’) concede al cliente una garanzia limitata sui prodotti
originali Apex nuovi e su qualsiasi pezzo di ricambio fornito da Apex secondo le condizioni di
garanzia applicabili al prodotto e il periodo di garanzia dalla data di acquisto riportati più
avanti. Questa garanzia non copre i danni causati da incidenti, cattivo uso, manomissione e
altri difetti non imputabili al materiale o alla produzione. Per esercitare i propri diritti ai sensi di
questa garanzia, si prega di contattare il rivenditore autorizzato Apex.
Prodotto Periodo di garanzia
Apparecchi CPAP (comprese le unità esterne di alimentazione) 2 anni
Serbatoio dell’acqua 6 mesi
Sistemi della maschera 6 mesi
Prodotti monouso Nessuno
168
Italiano
SIMBOLO
Produttore.
Rappresentante autorizzato nella Comunità Europea.
Attenzione
Consultare le istruzioni per l´uso.
Fare riferimento al libretto d’istruzioni
Simbolo BF, che indica che questo prodotto soddisfa il livello di protezione
contro scosse elettriche per dispositivi del tipo BF.
Classe II.
Protetto da corpi estranei solidi di 12,5 mm e più grandi; protetto dalla caduta
verticale di gocce d’acqua.
Linea di riempimento.
Uscita dell’aria del serbatoio dell’acqua.
Smaltimento di dispositivi elettrici ed elettronici (WEEE):
Questo prodotto deve essere depositato presso un punto di raccolta apposito
per il riciclaggio di dispositivi elettrici ed elettronici. Per informazioni più
dettagliate sul riciclaggio di questo prodotto, contattare l'ufficio competente
locale, il servizio di gestione dei rifiuti o il rivenditore presso cui è stato
acquistato il presente prodotto.
8. NOTE, ATTENZIONI E AVVERTENZE
NOTA: Indica delle informazioni a cui bisogna prestare particolare attenzione.
ATTENZIONE: Indica le procedure adeguate per il funzionamento o la manutenzione per evitare
danni o la distruzione del dispositivo o di altre proprietà.
AVVERTENZA: Richiama l'attenzione nei confronti di un rischio potenziale per cui è necessario
correggere le procedure o le pratiche per evitare danni alle persone.
5
E
nglish
2. Product Description
2.1 Unpacking the Contents
Components include:
(1) Main CPAP device with integrated heated humidifier
(2) Power supply adapter and AC power cord
(3) User manual
(4) Flexible air tubing, 1.8 m length
(5) Carrying bag
(6) SD card and USB cable
NOTE: Please use a SD card (smaller than 2GB) which complies with SDHC standard.
Before using it, please format it to FAT16 to ensure correct data collection.
CAUTION: Patient should not connect the device to a personal computer for data
downloading. This may cause the CPAP system failure.
To secure contents inside, the device and accessories are bundled in a paper packaged box.
Unpack this box by removing the device and accessories and check for any damage, which may
have occurred during shipping. If there are damages, please contact your dealer immediately.
2.2 System Overview
1. LCD Display
2. Up & Down Button
3. Start/Standby Button
4. Menu Button
5. SD Card Slot/mini-USB Connector
6. Air Filter
7. Heater Platform
8. Heater Indicator
9. Heater Control knob
10. Air Outlet
11. Power Socket
12. Air Outlet of the Water Chamber
13. Fill Line
14. Water Chamber
12
13
14
5
6
7
8
9
10
11
1
2
3
4
6
E
nglish
3. Installation
3.1 Disassembling the Water Chamber
1. Turn the device off and allow the heater and water to cool. If necessary, disconnect the
flexible tubing from the water chamber.
2. Place thumb on the top of the water chamber and tip it upward as shown in Figure 3-1.
Remove the water chamber from the system.
3. Unlock the water chamber by pulling the tab as shown in Figure 3-2. Remove the chamber lid
from the base.
3.2 Filling the Water Chamber
1. Fill the chamber to the fill line with distilled water (approx. 300 ml), as shown in
Figure 3-3.
2. If the silicon gasket has been removed, replace it securely on the top edge of the water
chamber base. Otherwise, the device will not deliver air properly.
3. Position the water chamber on the heater plate and push the bottom forward to lock it in place,
as shown in Figure 3-4. Make sure the silicon connector on the inlet connector fits securely
over the CPAP device air outlet.
CAUTION: Do not overfill the water chamber. Damage to the device may occur.
CAUTION: Use only room temperature water; do not fill the chamber with hot or chilled water.
CAUTION: Do not turn the heater on without the water chamber installed
CAUTION: When installing the water chamber, do not allow water to spill into the device.
CAUTION: Do not move the device when the chamber has water in it.
Figure 3-4
Figure 3-3
Figure 3-2
Figure 3-1
167
Italiano
7. Specifiche tecniche
Articolo Specifiche
Alimentazione
24 Vcc, 3,75 A
Adattatore di corrente PROTEK ELECTRONICS, Modello n. PMP90F-14-B22
Ingresso: 100-240 Vca, 50/60 Hz
Portata della pressione 4-20 cmH
2
0 (regolabile con incrementi di 0,5 cmH
2
0)
Tempo di rampa 0-45 minuti (regolabile con incrementi di 5 minuti)
Pressione iniziale di rampa 3-19 cmH
2
0 (regolabile con incrementi di 0,5 cmH
2
0)
Compensazione altitudine
Fino a 8.000 ft (2.438
m) quando la pressione è impostata su
4-18 cmH
2
O, ma limitata a 5.000 ft (1.524 m) quando la
pressione è impostata su 18,5 - 20 cmH
2
O
Dimensioni (W x D x H) 16,5 x 19,7 x 17,6 cm
Peso 1.14 kg
Livello sonoro 28 dBA a 10 cmH
2
0, alla distanza di 1 metro
Portata acqua 300 ml
Temperatura massima della
piastra del riscaldatore
Circa 70°C (158°F)
Calo di pressione 0,2 cmH
2
O @ 60 LPM
Umidità in uscita
10 mgH2O/L (temperatura ambiente di 23 °C ± 2 °C, umidità
relativa ambiente 60% ± 15%)
Temperatura
Funzionamento: da +5°C a +35°C (da +41ºF a +95°F)
Magazzinaggio: da -15°C a 50°C (da +5°F a + 122°F)
Trasporto: da -15°C a 70°C (da +5°F a +158°F)
Ambiente
Umidità
Funzionamento: 15% - 95% di umidità relativa, senza
formazione di condensa
Magazzinaggio: 10% - 90% di umidità relativa, senza
formazione di condensa
Trasporto: 10% - 90% di umidità relativa, senza formazione di
condensa
Classificazione:
Classe II,
Tipo BF, pezzi applicati: maschera nasale
Non idoneo all'uso in presenza di miscela anestetica
infiammabile.
IP21: Protetto da corpi estranei solidi di 12,5 mm e più grandi;
protetto dalla caduta verticale di gocce d’acqua.
Funzionamento continuo.
Note: Il produttore si riserva il diritto di modificare le specifiche senza preavviso.
166
Italiano
Appare un messaggio di Errore / Attenzione sul display
Tipo di messaggio Definizione
Messaggio sul display
Errore dovuto a impostazioni errate del
sistema.
Error 001
Errore per guasto al generatore del flusso. Error 002
Errore per impostazione errata del
temporizzatore o guasto al temporizzatore.
Error 003
Errore per guasto al sensore del flusso. Error 004
Errore:
Non è possibile
eseguire le
funzioni
primarie
Errore per guasto al riscaldatore (fusibil
e
termico saltato)
Error 005
Memoria del sistema insufficiente. Warn 001
Memoria del sistema quasi piena.
Warn 002
Errore di comunicazione del modulo della
scheda SD.
Warn 003
Rimuovere la scheda SD durante
l'elaborazione dei dati.
Warn 004
Scheda SD piena.
Warn 005
Inconsistent ID no. of device with SD card
Warn 006
Attenzione:
Wrong firmware version of SD card module
Warn 007
NOTA: Quando appare il messaggio di errore, contattare il medico o il fornitore per scaricare i dati
della memoria e resettare il misuratore.
7
E
nglish
3.3 Setting Up
1. Place the device on a flat surface and at a lower level than your sleeping position.
2. Connect one end of the air tubing firmly to the air outlet on the back of the device, as shown in
Figure 3-5.
3. Connect the other end of the air tubing to the mask system. Put on the mask and headgear
according to the mask instruction manual.
4. Plug the socket end of the AC power cord into the power supply adapter. Plug the pronged
end of the AC power cord into a main electrical outlet.
5. Plug the power supply cord’s adapter connector into the power inlet on the right side of the
device, as shown in Figure 3-6.
6. Once the power supply cord’s adapter connector is plugged into the power inlet, the CPAP
system is in ready to operate position (“STANDBY” sign appears in LCD display)
NOTE: The AC power cord also serves to disconnect the device.
NOTE: Do not position the equipment so that it is difficult to operate the
disconnecting device.
Figure 3-5 Figure 3-6
8
E
nglish
4. Operation
NOTE: Always read the operating instructions before use.
4.1 Control Panel Description
Buttons on control panel and main use of the buttons:
START/STANDBY
To start the treatment, simply press the "START/STANDBY" button. To stop the
treatment, press the "START/STANDBY" button again. The display will switch
between [STANDBY] and Therapy Pressure [ XX.X cmH
2
O] in cmH
2
O unit.
MENU
Press the "MENU" button to enter the setting mode when device is in standby mode.
The adjustment setting includes ramp time selection,
ramp starting pressure, therapy
pressure adjustment, alarm ON/OFF, clock alarm setting, compliance meter, and total
operating meter. When each setting's value has been changed, press "MENU" for
confirmation and press "MENU" again for next setting selection. Please refer to 4.3
Function Description section for detailed information.
UP
Press the "UP" button to increase the selected value.
DOWN
Press the "DOWN" button to decrease the selected value.
165
Italiano
accende affatto 2. PCB o indicatore consumato.
l’assistenza.
2. Rivolgersi all’agente locale, o al
rappresentante UE per
l’assistenza.
Non c’è flusso d’aria nella
maschera
1. Il dispositivo non è acceso
oppure non funziona
correttamente.
2. Il tubo flessibile non è
collegato correttamente.
3. Il tubo flessibile è ostruito.
1. Controllare che il cavo
d'alimentazione sia collegato
correttamente.
2. Collegare di nuovo, in modo
corretto, il tubo flessibile.
3. Sbloccare il tubo flessibile.
Condensa all’interno della
maschera o del tubo
flessibile
1. La piastra di riscaldamento
ha un’impostazione troppo
alta.
2. Inadeguatezza dell’ambiente
operativo o la posizione
dell’umidificatore riscaldato.
La temperatura vicina alla
maschera o al tubo flessibile
è bassa.
1. Regolare la manopola di
controllo per abbassare la
temperatura.
2. Rimuovere qualsiasi sistema di
condizionamento nelle vicinanze
dell’umidificatore riscaldato.
Oppure, mantenere la
temperatura della stanza intorno
a 25º C.
Perdita d’acqua 1. L’installazione del serbatoio
dell’acqua non è stata
eseguita correttamente.
2. Il serbatoio dell’acqua è
logoro.
1. Rimuovere il serbatoio
dell’acqua dall’umidificatore
riscaldato, svuotarlo e rimetterlo
a posto; accertarsi che il
serbatoio dell’acqua si blocchi in
sicurezza e riempirlo fino alla
linea di riempimento e verificare
se perde ancora.
2. Sostituire con un nuovo
serbatoio dell’acqua.
164
Italiano
6. Soluzione dei problemi
Nella seguente tabella sono riportate le soluzioni a eventuali problemi per l'eliminazione dei guasti
che dovessero sorgere. Se il problema dovesse persistere, contattare il centro di assistenza più
vicino.
Pr obl em a P ossi bili ca use So luz ioni
Non si accende lo
schermo
1. Il cavo di alimentazione non è
inserito nella presa di
corrente.
2. Guasto al display LCD o al
circuito stampato.
1. Verificare che il cavo di
alimentazione sia collegato.
2. Contattare il rivenditore per la
riparazione.
Codice errato sul display
Guasto al display LCD o al circuito
stampato.
Contattare il rivenditore per la
riparazione.
L'illuminazione del display
LCD non si accende
Guasto al LED Contattare il rivenditore per la
riparazione.
Pulsanti disattivati Guasto al pulsante Contattare il rivenditore per la
riparazione.
Il flusso dell'aria è lento 1. Durante il tempo di rampa.
2. Il filtro è molto sporco.
3. Guasto al generatore del
flusso.
1. Controllare le impostazioni del
tempo di rampa.
2. Sostituire o pulire il filtro
regolarmente.
3. Contattare il rivenditore per la
riparazione.
Non è possibile copiare i
dati nella scheda SD
1. La scheda SD è piena.
2. La scheda SD non è stata
inserita correttamente.
3. I dati sulla scheda SD sono
danneggiati.
1. Assicurarsi che la scheda SD
abbia spazio sufficiente.
2.
Assicurarsi che la scheda SD sia
inserita nel lettore.
3. Formattare la scheda.
L’indicatore d’accensione
dell'umidificatore integrato
non si accende
1. Il cavo d'alimentazione è
collegato ad una presa di
corrente che non funziona.
2. L'interruttore d’alimentazione
non è in posizione
d’accensione.
3. PCB o indicatore consumato.
4. Fusibile saltato.
1. Collegare il c
avo d'alimentazione
ad una presa di corrente
funzionante.
2. Fare riferimento alla procedura
d’installazione per l’accensione.
3. Rivolgersi all’agente locale, o al
rappresentante UE per
l’assistenza.
4. Rivolgersi all’agente locale, o al
rappresentante UE per
l’assistenza.
L’indicatore d’accensione
del riscaldatore non si
1. Surriscaldamento della
piastra di riscaldamento.
1. Rivolgersi all’agente locale, o al
rappresentante UE per
9
E
nglish
4.2 Function Description
Getting Started – First time use.
For first-time use, follow the steps below:
1. Make sure that your doctor or care provider has initialized and configured the appropriate
treatment values into the unit.
2. Make sure that your package contains a face or nasal mask with headgear. If not, your
doctor or care provider can recommend the type of mask and headgear you must obtain
3. Attach tubing and mask (see Setup section).
4. Attach power cord to the unit and an electrical outlet (see Setup section). Unit will power-on
automatically.
5. Use the “MENU button to set the Current Time, Ramp Up Time, and Ramp Starting
Pressure, (see “MENU” Button Section for description of these options).
Note that these values may have already been set by your doctor or care provider.
6. Press the “START/STANDBY” button – Airflow to the mask will begin.
7. You can now place the Headgear and Mask over your head and face and begin treatment.
4.3 Menu Button - Option Description
(1) Ramp Time (only CPAP mode)
Ramp time function allows user to fall into sleep with a lower, comfortable pressure and helps
users gradually get accustomed to increasing treatment pressure. The first selection of
pressing "MENU" is [Ramp XX MIN]. When the "MENU" setting is in [Ramp XX MIN]
mode, press "UP" or "DOWN" button to set the preferred ramp time and press "MENU" for
confirmation. There are 10 adjustable levels, 0, 5, 10, 15, 20, 25, 30, 35, 40 and 45 minutes.
(2) Ramp Starting Pressure (only CPAP mode)
Press "MENU" button to select [Ramp P XX.X] menu, press "UP" or "DOWN" button to
set the preferred ramp starting pressure and press "MENU" for confirmation. The ramp
starting pressure can be changed from 3 cmH
2
O to “Therapy Pressure 1” cmH
2
O. For
example, if your therapy pressure is 10 cmH
2
O, the maximum ramp starting pressure you can
select is 9 cmH
2
O.
(3) Therapy Pressure (only CPAP mode)
Press "MENU" button to select the [P XX.XcmH
2
O] menu. You can view the current
pressure setting displayed in cmH
2
O unit. Therapy pressure is adjustable only by the provider,
a respiratory therapist or doctor.
NOTE: The therapy pressure is to only be prescribed by a physician.
(4) PVA (Pressure Variation Algorithm)
Press "MENU" button to select [c on/off] menu, you can view if the PVA function is
enabled by the provider, a respiratory therapist or physician. The PVA function delivers
pressure relief upon exhalation to improve comfort. If the PVA function is enabled, press "UP"
or "DOWN" button to adjust the comfort level. There are 3 adjustable levels of pressure relief
that you feel while exhalation. Level 1 provides small pressure variation; and level 3 provides
higher pressure variation.
10
E
nglish
(5) Low Pressure Auto Off (only CPAP mode)
Press "MENU" button to select [LOW P on/off] menu, you can view if the Low Pressure Auto
Off setting is enabled and the device will be automatically turned off while detecting a large
leak for 3 minutes. This setting is adjustable only by the provider, a respiratory therapist or
physician.
(6) Compliance Meter
Press "MENU" button to select the [CM XXXX.X hr] menu. The compliance meter records
the total therapy hours for the device. The compliance meter should be re-set only by the
provider, a respiratory therapist or by a doctor.
(7) Alarm
Press "MENU" button to select the [Alarm on/off] menu, and press "UP" or "DOWN" button
to set the alarm on or off. When the alarm is turned on, the audible alarm will activate with
warning messages shown on the LCD display. Set alarm off to mute the audible alarm.
(8) Clock Alarm
Press "MENU" button to select the [Clock Alarm on/off] menu and press "UP" or "DOWN"
button to set the clock alarm on or off. When the clock alarm is set on, the display will show
the time on the left side. Press "UP" or "DOWN" button to set the time to wake you up. Once
the clock alarm is activated, press the start/standby button to mute the audible alarm.
(9) Clock
Press "MENU" button to select the [Clock XX:XX] menu, press "UP" or "DOWN" button to
set the current time.
(13) Turning off the Device
Remove the power cord from the electrical outlet, and disconnect power cord from the power
socket on the right side of the device.
NOTE: Once the setting is confirmed, press the “MENU” button. Otherwise, the device
will automatically go back to standby without saving the modification if no action
is taken in 20 seconds.
(14) Event Indication
While the device is on standby mode, press UP" and "DOWN" button at the same time to see
the latest one data of Apnea Index (AI), Hypopnea Index (HI) and Snoring Index (SI) on the
display. Press "MENU" button to show each index in sequence. To go back to standby mode,
press "START/STANDBY" button.
NOTE:
Once the device is re-started, all the indexes will be re-calculated. The whole
data of these indexes are only seen by respiratory therapists or physicians by
using Easy Compliance playback software.
163
Italiano
5.3 Manutenzione del filtro dell'aria
Per il funzionamento ottimale del dispositivo, l’utente deve pulire il filtro dell'aria almeno una volta
ogni due settimane o più spesso se il sito è polveroso.
Si consiglia di sostituire il filtro con uno nuovo dopo 6 mesi di utilizzo; tuttavia, in base alla qualità
dell’aria ambientale, tale periodo può variare.
ATTENZIONE: Se il filtro dell’aria è sporco, si potrebbero raggiungere temperature di
funzionamento elevate, in grado di incidere negativamente sul funzionamento
del dispositivo. Accertarsi che il filtro dell’aria sia sempre pulito ed inserito
correttamente.
1. Aprire il coperchio del filtro dell'aria sul retro del dispositivo.
2. Togliere il filtro sporco. Lavare il filtro con acqua tiepida e un
detergente neutro e risciacquare con acqua. Fare asciugare
completamente il filtro all’aria prima di reinstallarlo. Non usare
un filtro non completamente asciutto. Se il filtro è rotto,
sostituirlo.
3.
Inserire un filtro nuovo.
5.4 Serbatoio dell'acqua
1. Spegnere il riscaldatore e lasciare raffreddare anche l'acqua.
2. Disinserire il tubo flessibile dal serbatoio dell'acqua. Posizionare un pollice sulla parte
superiore del serbatoio dell'acqua e sollevarlo per staccarlo dal sistema. Aprire il
serbatoio e svuotare l'acqua rimanente.
3. Utilizzare un detergente neutro per lavare tutte le parti del serbatoio. Sciacquare con
acqua pulita e lasciare asciugare all'aria.
4. Tutti gli elementi del serbatoio sono soggetti a normale usura e sono eventualmente
sostituibili. In caso di danneggiamento, sostituire le parti del serbatoio.
162
Italiano
5. Pulizia & Manutenzione
5.1 Pulizia dell'Unità Principale
L'unità principale deve essere pulita regolarmente (almeno ogni 30 giorni). Spolverare e pulire
l'unità con un panno umido e un detergente delicato. Fare attenzione a non usare un detergente in
grado di intaccare la superficie della carcassa di plastica. Tutti gli elementi devono essere
asciugati bene all'aria prima dell'uso. Dopo la pulizia, controllare il dispositivo e tutte le parti del
circuito per riscontrare eventuali danni e sostituire i pezzi danneggiati.
AVVERTENZA: Non cercare di aprire questo dispositivo. Le riparazioni e la manutenzione
interna devono essere effettuate esclusivamente da personale del servizio di
assistenza autorizzato. Non lasciare cadere nessun oggetto nel tubo
dell'aria o nell'uscita dell'aria.
5.2 Tubo e maschera
Il tubo e la maschera devono essere controllati e puliti regolarmente. Fare riferimento alle istruzioni
per la pulizia fornite con gli assessori.
1. Staccare il tubo dell'aria dall'uscita dell'aria del dispositivo.
2. Staccare il tubo dell'aria e le cinghiette dalla maschera nasale.
3. Lavare il sistema della maschera seguendo le istruzioni fornite.
4. Lavare i tubi dell’aria con acqua tiepida e un detergente neutro. Risciacquare bene,
appendere e lasciare asciugare.
5. Prima di un nuovo uso, montare la maschera sul copricapo in base alle istruzioni fornite con
quest’ultima.
6. Tutti gli elementi della maschera e del tubo dell'aria sono soggetti a usura e rottura normali e
devono essere sostituiti in caso di danneggiamento.
ATTENZIONE:
Non usare candeggina, cloro, alcool o profumi (compresi gli oli
profumati), saponi idratanti o antibatterici per pulire il cuscino facciale, la
maschera e il tubo dell’aria. Queste soluzioni potrebbero provocarne
l’indurimento, riducendo la durata del prodotto.
ATTENZIONE:
Non lavare o asciugare la maschera o il tubo d’aria a una temperatura
superiore a 70º C (160º F).
AVVERTENZA: Non utilizzare nessun detergente contenente profumi o balsami dal
momento che potrebbero lasciare dei residui.
AVVERTENZA: La maschera non deve essere riutilizzata da altre persone per evitare il
rischio di infezione incrociata.
11
E
nglish
4.4 Flowchart of Menu settings
Enter the user's menu mode by pressing the “MENU” button.
In each setting, when the preferred value has been selected, press "MENU" for confirmation and
press "MENU" again to enter next selection.
NOTE: For doctors, please refer to a separate “Doctor’s Additional Instructions” manual.
Ramp
(Ramp Time)
P
(Therapy Pressure)
CM
(Compliance Meter)
< 0, 5, 10, 15, ……………., 45> min
< 4, 4.5, 5, 5.5, ……………., 20> cmH2O
< XXXX.X > hr
Ramp P
(Ramp Starting Pressure)
< 3, 3.5, 4, 4.5, ……………., 19> cmH2O
Low P
(Low Pressure Shut Off)
< on/off >
Alarm
Clock Alarm
Clock
< hh: mm >
Clock Alarm <On>
< hh: mm >
< on/off >
C
(PVA Comfort Level)
PVA <On>
<0, 1, 2, 3>
12
E
nglish
4.5 Using the heated humidifier
1. Turn the control knob on the back of the device to turn on the heater and the heater on indicator
above the knob will light up (orange light), as shown in Figure 4-1
2. Adjust the control knob to increase the humidity in the range of 1 to 6 (see diagram). 1 is
minimum humidity, 6 is maximum humidity. The optimum setting is dependent on the ambient
temperature and humidity of your room.
Danger: In order to avoid the destruction or damage to the device or even the hazard of
electric shock, when the water chamber is attached, DO NOT fill water from the
outlet port of the water chamber. Users must fill water no more than the
maximum mark after the water chamber is removed from the device.
4.6 Using the SD card
If doctors need to review the usage data, they may ask you to use the SD card to copy data from
the device, and to return the card to them. Data that is copied to the SD Card is still stored and
available on the device.
1. Insert the SD Card when the device is in standby mode.
2. Data copying starts automatically when the SD Card is inserted into the slot.
3. The [COPY] & [Card] message is displayed on the LCD while data is being copied.
4. The [End] & [OK] message is displayed on the LCD when copying has finished.
5. Remove the SD Card and mail it to the clinician.
6. The SD Card should be stored in the plastic card case when not in use. The SD card
does not need to be uninstalled for the device to work properly.
CAUTION: Do not remove the SD card until [End] & [OK]
message is displayed on the LCD,
or data copied to the card may be corrupted or missing.
Figure 4-1
161
Italiano
4.5 Utilizzo del deumidificatore riscaldato
1. Ruotare la rotella che si trova sul retro del dispositivo per attivare il riscaldatore: si
accende così l'indicatore del riscaldatore al di sopra la rotella (luce arancione), come
mostrato in Figura 4-1.
2. Regolare la rotella per aumentare l’umidità nell’intervallo da 1 a 6 (fare riferimento al
diagramma). Il numero 1 è l’umidità minima e il numero 6 quella massima. Le
impostazioni ottimali dipendono dalla temperatura ambiente e dall’umidità della stanza.
Pericolo: Per evitare di rompere o di danneggiare il dispositivo, oppure il rischio
di elettrocuzione, quando il serbatoio dell'acqua è inserito, NON
riempirlo versando l’acqua dall’uscita dell’aria. Per riempire il serbatoio,
rimuoverlo dal dispositivo e non superare mai il livello massimo.
4.6 Uso della scheda SD per la raccolta di dati
Se i medici hanno bisogno di controllare i dati relativi all'uso, possono chiedere all'utente di
utilizzare la scheda SD per copiare dati dal dispositivo, e di restituire loro la scheda. I dati copiati
sulla scheda SD sono conservati e disponibili sul dispositivo.
1. Inserire la scheda SD quando il dispositivo è in modalità standby.
2. La copia dei dati inizia automaticamente quando la scheda SD viene inserita nel lettore.
3. Il messaggio [COPY] & [Card] lampeggia sul display LCD mentre i dati sono copiati.
4. Il messaggio [End] & [OK] compare sul display LCD una volta conclusa la copia.
5. Rimuovere la scheda SD e spedirla al medico.
6. La scheda SD deve essere conservata nell'apposita confezione di plastica quando non
viene utilizzata. Non è necessario disinstallare la scheda SD per il corretto funzionamento
del dispositivo.
ATTENZIONE: Non rimuovere la scheda SD finché non compare la dicitura [End] & [OK]
sul display LCD, altrimenti i dati copiati sulla stessa potrebbero essere
incompleti o dare errore.
Figur
a
4
-
1
160
Italiano
(11) Indicazione eventi
Con il dispositivo in modalità standby, premere contemporaneamente i pulsanti “UP" e
"DOWN" per visualizzare gli ultimi dati di Indice di Apnea (AI), Indice di Ipopnea (HI) e
Indice di Russamento (SI) sul display. Premere il pulsante "MENU" per visualizzare ogni
indice in sequenza. Per tornare alla modalità standby, premere il pulsante
"START/STANDBY".
NOTA: Una volta riavviato il dispositivo, tutti gli indici vengono ricalcolati. Tutti i dati di
questi indici possono essere visualizzati unicamente dai terapisti della
respirazione o dai medici utilizzando il software di riproduzione Easy
Compliance.
4.4 Diagramma di flusso delle impostazioni del menù
Entrare nella modalità menù utente premendo il pulsante "MENU"
Ad ogni impostazione, una volta selezionato il valore desiderato, premere "MENU" per confermare
e premere di nuovo "MENU" per passare alla selezione successiva.
NOTA: I medici sono pregati di fare riferimento alle apposite "Istruzioni aggiuntive per il medico".
Ramp
(Tempo di rampa)
P
(Pressione della Terapia)
Low P
(Spegnimento automatico bassa pressione)
Ramp P
(Pressione iniziale di rampa)
CM
(Misuratore di Compliance)
Alarm (
Allarme)
Clock Alarm (
Sveglia)
Clock (Orologio)
Clock Alarm <On >
< 0, 5, 10, 15, ……………., 45> min
< 4, 4.5, 5, 5.5, ……………., 20> cmH2O
< XXXX.X > hr
< 3, 3.5, 4, 4.5, ……………., 19> cmH2O
< on/off >
< hh: mm >
< hh: mm >
< on/off >
C
(Livello di comfort PVA)
PVA <On>
<0, 1, 2, 3>
13
E
nglish
5. Cleaning & Maintenance
5.1 Device
The device should be checked and dusted regularly (at least every 30 days). Wipe with a damp
cloth and a mild detergent and keep it free from dust. If other detergent is used, choose one that
will have no chemical effects on the surface of the plastic case. All parts should be air-dried
thoroughly before use. Inspect the device and all circuit parts for any damage after cleaning and
replace if necessary.
WARNING:
Don’t try to open this device. Repairs and internal servicing should only performed by
an authorized service agent. Do not drop any object into the air tube or air outlet.
5.2 Tubing and Mask
The tubing and mask should be checked and cleaned regularly. Please refer to the cleaning
instruction s that come with the accessories.
1. Disconnect the air tubing from the air outlet of the device.
2. Remove the air tubing and headgear straps from the mask.
3. Wash the mask system according to the instructions supplied with it.
4. Wash the air tubing in warm water using mild detergent. Rinse thoroughly, hang and allow to
dry.
5. Before next use, assemble the mask and headgear according to the mask user instructions.
6. All items of the mask and air tubing are subject to normal wear and tear and may eventually be
replaced. Replace the mask and the air tubing if they are damaged.
CAUTION: Do not use bleach, chlorine-, alcohol-, or aromatic-based (
including all scented oils
moisturizing or antibacterial soaps to clean the cushion, mask or air tubing. These
solutions may cause hardening and reduce the life of the product.
CAUTION: Do not wash or dry the mask or air tubing at a temperature above 70°C (160°F)
WARNING: Do not use any cleaner containing fragrance or conditioners as they will leave a
residue.
WARNING: The mask must not be re-used by another person. This is to avoid the risk of
cross-infection.
14
E
nglish
5.3 Air Filter
For an optimum operation of the device, the air filter can be cleaned by the user at least once
every two weeks or more often if this device is operated in a dusty environment. It is recommended
that the filter be replaced with a new one after 6 months of use; however, depending on the air
quality, the replacement time may vary.
CAUTION:
Dirty air filter may cause high operating temperatures that
affect device
performance. Ensure the air filter is cleaned
and fitted at all times
1. Remove the dirty filter from the enclosure on the rear of the device.
2.
Wash the filter in warm water with a mild detergent, and rinse with
water. Allow the filter to air dry completely b
efore reinstalling. Do not
use a filter that is not completely dry. If the filter is torn, replace it.
3. Reinstall the filter.
NOTE: Please follow national requirements to dispose of the unit properly.
5.4 Water Chamber
1. Turn the heater off and allow the heater and water to cool.
2. Disconnect the flexible tubing from the water chamber. Place thumb on the top of the water
chamber and lift it to separate it from the system. Open the chamber and empty the remaining
water.
3. Use a mild detergent to wash all the chamber parts. Rinse all the parts with clear water and
allow them to air dry.
4. All items of the chamber are subject to normal wear and tear and may eventually be replaced.
Replace the chamber parts if any damage is present.
159
Italiano
(4) PVA (Pressure Variation Algorithm - Algoritmo di Variazione della Pressione)
Premere il pulsante "MENU" per selezionare il menù [c on/off] e vedere se la funzione PVA
è stata attivata dal medico, dall’operatore sanitario o dal terapista respiratorio. La funzione PVA
allevia la pressione durante l'esalazione per aumentare il comfort. Se la funzione PVA è
attivata, premere il pulsante "UP" o "DOWN" per impostare il livello di comfort. Vi sono 3 livelli
disponibili per alleviare la pressione durante l'esalazione. Il livello 1 prevede una leggera
variazione della pressione mentre il livello 3 fornisce la variazione di pressione più elevata.
(5) Spegnimento automatico bassa pressione (solo modalità CPAP)
Premere il tasto “MENU” per selezionare il menu [LOW P on/off]; si può vedere se
l’impostazione della funzione Spegnimento automatico bassa pressione è abilitata in modo tale
che il dispositivo si spenga automaticamente quando rileva una perdita per 3 minuti. Questa
impostazione è regolabile solo dal medico, dall’operatore sanitario o da un terapista
respiratorio.
(6) Misuratore di compliance
Premere il pulsante "MENU" per selezionare il menù [CM XXXXX hr], il misuratore di
compliance registra le ore totali di terapia per il dispositivo. Il misuratore di compliance deve
essere resettato solo dal medico, dall’operatore sanitario o da un terapista respiratorio.
(7) Allarme
Premere il pulsante "MENU" per selezionare il menù [Alarm on/off]; premere il pulsante "UP"
o "DOWN" per impostare l'allarme su acceso o spento. Quando si accende l'allarme, si
attiva il segnale acustico con un messaggio di avvertenza sul display LCD. Impostare l'allarme
su off per disattivare il segnale acustico.
(8) Sveglia
Premere il pulsante "MENU" per selezionare il menù [Clock Alarm on/off]; premere il
pulsante "UP" o "DOWN" per impostare la sveglia su acceso o spento. Quando si imposta la
sveglia, l'ora compare sul lato sinistro del display. Premere il pulsante "UP" o "DOWN" per
impostare l'ora della sveglia. Una volta attivata la sveglia, premere il pulsante
“START/STANDBY” per tacitare il segnale acustico.
(9) Orologio
Premere il pulsante "MENU" per selezionare il menù [Clock XX:XX]; premere il pulsante
"UP" o "DOWN" per impostare l'ora attuale.
(10) Spegnere il dispositivo
Staccare la spina del cavo di alimentazione dalla presa elettrica e disinserire il cavo di
alimentazione dalla presa sul retro del dispositivo.
NOTA: Una volta confermata l'impostazione, premere il pulsante "MENU". Altrimenti, se
non viene effettuata alcuna operazione entro 20 secondi, il dispositivo torna
automaticamente in modalità standby senza salvare le modifiche.
158
Italiano
4.2 Descrizione delle funzioni
Come iniziare - Uso del dispositivo per la prima volta.
Per utilizzare il dispositivo per la prima volta, seguire i passi indicati qui sotto:
1. Assicurarsi che il medico o l’operatore sanitario abbia inizializzato e impostato nel dispositivo i
valori adatti al trattamento.
2. Assicurarsi che il pacchetto contenga una maschera facciale o nasale con il relativo
copricapo. Altrimenti il medico o l’operatore sanitario può consigliare il tipo di maschera e di
copricapo da richiedere.
3. Fissare il tubo e la maschera (vedi capitolo Installazione).
4. Collegare il cavo di alimentazione al dispositivo e a una presa di corrente (vedi capitolo
Installazione). Il dispositivo si accende automaticamente.
5. Usare il pulsante "MENU" per impostare l'ora attuale, il tempo di rampa e la pressione iniziale
di rampa, (vedi capitolo "Pulsante MENU" per la descrizione di queste opzioni).
Questi valori potrebbero essere stati già impostati dal medico o dall’operatore sanitario.
6. Premere il pulsante "START/STANDBY" e si avvia il flusso dell'aria verso la maschera.
7. Si possono quindi indossare il copricapo e la maschera per iniziare il trattamento.
4.3 Pulsante MENU - Descrizione delle opzioni
I seguenti elementi descrivono le opzioni che appaiono una volta premuto il pulsante "MENU" sul
pannello di controllo.
(1) Tempo di rampa (solo modalità CPAP)
La funzione Tempo di rampa consente all'utente di addormentarsi con una pressione più bassa
e confortevole, per abituarsi gradualmente all'aumento della pressione di trattamento. Quando
si preme "MENU" la prima selezione è [Ramp XX MIN]. Quando l'impostazione "MENU" si
trova in modalità [Ramp XX MIN], premere il pulsante "UP" o "DOWN" per impostare il tempo
di rampa desiderato, quindi premere "MENU" per confermare. Esistono 10 livelli di regolazione:
0, 5, 10, 15, 20, 25, 30, 35, 40 e 45 minuti.
(2) Pressione iniziale di rampa (solo modalità CPAP)
Premere il pulsante "MENU" per selezionare il menù [Ramp P XX.X], premere il pulsante "UP"
o "DOWN" per impostare la pressione iniziale di rampa desiderata, quindi premere "MENU"
per confermare. La pressione iniziale di rampa può variare da 3 cmH
2
0 a "Pressione della
Terapia - 1" cmH
2
0. Ad esempio, se la pressione della terapia è 10 cmH
2
0, la pressione iniziale
di rampa massima che si può selezionare è 9 cmH
2
0.
(3) Pressione della terapia (solo modalità CPAP)
Premere il pulsante "MENU" per selezionare il menù [P XX.XcmH
2
O]; si pvisualizzare la
pressione impostata in unità cmH
2
0. La pressione della terapia può essere regolata solo dal
medico, dall’operatore sanitario o da un terapista respiratorio.
NOTA: La pressione della terapia deve essere prescritta solo da un medico.
15
E
nglish
6. Troubleshooting
The table below lists troubleshooting solutions for the problems that may happen. If the problem
persists, contact your equipment provider’s service agent.
Pr obl em Po ss ibl e C aus es So lutions
No display 1. The power cord is not
connected to the power
socket.
2. LCD failure or controlled
PCB failure.
1. Ensure the power cord is connected.
2. Contact your equipment provider for
repair.
Display code incorrect LCD failure or controlled PCB
failure.
Contact your equipment provider for repair.
Illuminator under LCD is
not on
LED failure Contact your equipment provider for repair.
Buttons do not work Button failure Contact your equipment provider for repair.
Air delivered is slow 1. During ramp time.
2. Filter is too dirty.
3. Flow generator failure.
1. Check the ramp time setting
2. Change or clean the filter regularly.
3. Contact your equipment provider for
repair.
Data can not be c
opied to
the SD card
1. SD card is full.
2. SD card is not inserted
correctly.
3. Data on the SD card is
corrupted.
1. Ensure the SD card has enough
capacity.
2. Ensure the SD card
is inserted into the
slot.
3. Format the card.
Integrated humidifier
power on indicator not lit
up
1. Power cord not plugged into
a working AC outlet.
2. Power switch is not turned
on
3. PCB or indicator worn out
4. Fuse blown
1.
Plug in the power cord to a working AC
outlet.
2. See Set up procedure and turn the
power on.
3. Contact your local agent or EU
representative for service.
4. Contact your local agent or EU
representative for service.
Heater on indicator not lit
at all
1. Heater plate over heating
2. PCB indicator worn out
1. Contact your local agent or EU
representative for service.
2. Contact your local agent or EU
representative for service.
There is no air flow
through the mask
1. Device is not turned on or
working correctly
2. Flexible tubing is not
connected right.
3. Flexible tube is blocked.
1. Check the power cord is connected
properly.
2.
Reconnect the flexible tubing correctly.
3. Unblock the flexible tube.
16
E
nglish
Condensation in mask or
flexible tube
1. The heater plate setting is
too high.
2. The operating environment
or position of heated
humidifier is not correct. The
temperature close to mask or
flexible tube is low.
1. Adjust the control knob to low
temperature setting.
2.
Remove any air conditioner which may
nearby the heated humidifier. Or keep
room temperature up near 25°C
Water Leakage 1. Wwater chamber is not
properly assembled.
2. Water chamber worn out.
1. Remove the water chamber from the
heated humidifier, pour out the water
and reassemble the water chamber
again, making sure water chamber
closes securely, and fill the water till it
reaches fill line and check if it still
leaks or not.
2. Replace with a new water chamber.
Error / Warning Messages shown on LCD
Message type Definition
Message in LCD
Error for abnormal system settings
Error 001
Error for flow generator failure
Error 002
Error for abnormal timer setting or timer
failure
Error 003
Error for flow sensor failure
Error 004
Error:
Primary function can’t
execute.
Error for heater failure (thermal fuse
blows off)
Error 005
Out of system memory
Warn 001
System memory is nearly full
Warn 002
SD card module communication failure
Warn 003
Remove the SD card while data is being
processed
Warn 004
SD card is full
Warn 005
Inconsistent ID no. of device with SD
card
Warn 006
Warning:
Wrong firmware version of SD card
module
Warn 007
NOTE: When the warning message appears, contact your doctor or equipment provider to
download the memory data and reset the meter.
157
Italiano
4. Funzionamento
NOTA: Leggere sempre le istruzioni di funzionamento prima dell'uso.
4.1 Descrizione del pannello di controllo
Disposizione dei pulsanti sul pannello di controllo e principale uso degli stessi:
START/STANDBY
Per avviare il trattamento basta premere il pulsante "START/STANDBY". Per arrestare il
trattamento premere di nuovo il pulsante "START/STANDBY". Sul display compaiono in
modo alterno [STAND BY] e la pressione della terapia [ XX.X cmH
2
0] in unità cmH
2
0.
MENÙ
Quando l'unità si trova nella modalità "Standby", per entrare nei menù di configurazione
basta premere il pulsante "MENU". È possibile impostare il tempo di rampa, la
pressione iniziale della rampa, la pressione della terapia, l'accensione/spegnimento
dell'allarme, l'impostazione dell'ora dell'allarme, il misuratore di compliance e il
misuratore del funzionamento totale. Per confermare l’impostazione di un valore,
premere il pulsante "MENU" e premere di nuovo "MENU" per selezionare un’altra
impostazione. Per ulteriori informazioni, vedi il punto 4.2 (Descrizione delle funzioni).
UP
Premere il pulsante "UP" per selezionare il valore in aumento.
DOWN
Premere il pulsante "DOWN" per selezionare il valore in diminuzione.
156
Italiano
3.3 Installazione
1. Sistemare il dispositivo su una superficie piana, in una posizione più bassa rispetto
quella di riposo (del letto).
2. Inserire saldamente un’estremità del tubo dell’aria alla presa d’aria sulla parte posteriore
del dispositivo, come mostrato nella Figura 3-5.
3. Inserire l’altra estremità del tubo dell’aria alla maschera. Indossare la maschera e il
copricapo attenendosi alle istruzioni del manuale d’uso della maschera.
4. Collegare il connettore del cavo d’alimentazione all’adattatore di corrente. Inserire la
spina del cavo d'alimentazione in una presa di corrente.
5. Collegare il connettore del cavo d’alimentazione dell’adattatore di corrente nella presa
d’alimentazione sul lato destro del dispositivo, come mostrato nella Figura 3-6.
6. Dopo avere collegato il cavo d’alimentazione dell’adattatore alla presa di corrente, il
sistema CPAP è pronto per funzionare (sul display LCD appare la dicitura “STANDBY”)
NOTA: Il cavo d’alimentazione serve anche per disinserire il dispositivo.
ATTENZIONE: Non posizionare il dispositivo in moto tale da ostacolarne il
disinserimento.
Figura 3
-
5
Figura 3
-
6
17
E
nglish
7. Technical Specifications
It em Spe cif ica ti on s
Power Supply DC24V, 3.75A
Power Adapter PROTEK ELECTRONICS, Model No.: PMP90F-14-B22
Input: AC 100-240VAC, 50/60Hz
Pressure Range 4 –20 cmH
2
O (adjustable in 0.5 cmH
2
O increments)
Ramp Time 0 – 45 minutes (adjustable in 5-minute increments)
Ramp Starting Pressure 3 cmH
2
O to therapy pressure (adjustable in 0.5 cmH
2
O increments)
Operating Altitude up to 8,000 ft (2,438 m) when the pressure is set at 4-18 cmH
2
O but
limited to 5,000ft (1,524m) when the pressure is set at 18.5 - 20 cmH
2
O
Dimensions (W x D x H) 16.5 x 19.7 x 17.6 cm
Weight 1.14 kg
Sound Level < 28 dBA at 10 cmH
2
O, 1 metre distance
Water Capacity 300ml
Maximum Heater Plate
Temperature
Approximate 70°C (158°F)
Pressure Drop 0.2cmH
2
O @ 60LPM
Humidity Output:
10 mgH
2
O/L
(Ambient temperature: 23°C ± C & Relative humidity:
60% ± 15%)
Temperature
Operating: +5°C to +35°C (+41°F to +95°F)
Storage: -15°C to 50°C (+5°F to +122°F)
Shipping: -15°C to 70°C (+5°F to +158°F)
Environment
Humidity Operating: 15%RH to 95%RH non-condensing
Storage: 10%RH to 90%RH non-condensing
Shipping: 10%RH to 90%RH non-condensing
Classification
Class II
Type BF, Applied Parts: Mask
Not suitable for use in the presence of a flammable anaesthetic mixture
IP21: Protected against solid foreign objects of 12.5 mm and greater;
Protected against vertically falling water drops.
Continuous operation.
Note: the manufacturer reserves the right to modify the specifications without notice.
18
E
nglish
Symbols
BF sy
mbol, which indicated this product is according to the degree of protecting
against electric shock for type BF equipment.
Attention, should read the instructions.
Refer to instruction manual
Attention, should read the instructions.
Class II
Protected against solid foreign objects of 12.5 mm and greater; Protected against
vertically falling water drops.
Disposal of Electrical & Electronic Equipment (WEEE):
This product shou
ld be handed over to an applicable collection point for the
recycling of electrical and electronic equipment. For more detailed information
about the recycling of this product, please contact your local city office, household
waste disposal service or the retail store where you purchased this product.
Fill line
Air flow direction
Authorized representative in the European community
Manufacturer
8. NOTE, CAUTION, AND WARNING STATEMENTS
NOTE: Indicates information that you should pay special attention to.
CAUTION:
Indicates correct operating or maintenance procedures in order to prevent
damage to or destruction of the equipment or other property.
WARNING:
Calls attention to a potential danger that requires correct procedures or
practices in order to prevent personal injury.
155
Italiano
3. Installazione
3.1 Smontaggio del serbatoio dell’acqua
1. Spegnere il dispositivo e lasciare raffreddare il riscaldatore e l’acqua. Se necessario,
staccare i tubi flessibili dal serbatoio dell’acqua.
2. Appoggiare il pollice sulla parte superiore del serbatoio dell’acqua ed inclinarlo verso
l’alto come mostrato nella Figura 3-1. Rimuovere il serbatoio dell’acqua dal sistema.
3. Sbloccare il serbatoio dell’acqua premendo la linguetta come mostrato nella Figura 3-2.
Rimuovere il coperchio del serbatoio dalla base.
3.2 Riempimento del serbatoio dell’acqua
1. Riempire il serbatoio con acqua distillata fino alla linea di riempimento
(circa 300 ml), come mostrato nella Figura 3-3.
2. Se è stata rimossa la guarnizione di silicone, rimetterla a posto sul bordo superiore della
base del serbatoio, altrimenti il dispositivo non eroga correttamente l’aria.
3. Sistemare il serbatoio dell’acqua sulla piastra di riscaldamento e spingere la parte
inferiore per bloccarlo in posizione, come mostrato nella Figura 3-4. Assicurarsi che il
connettore di silicone della presa d’aria sia fissato in sicurezza all’uscita dell’aria del
dispositivo CPAP.
ATTENZIONE: Non riempire il serbatoio dell’acqua oltre la linea di riempimento,
altrimenti si potrebbe danneggiare il dispositivo.
ATTENZIONE: Usare solo acqua a temperatura ambiente; non riempire il serbatoio con
acqua calda o refrigerata.
ATTENZIONE: Non attivare il riscaldatore senza che sia installato il serbatoio dell’acqua.
ATTENZIONE: Nell’installazione del serbatoio dell’acqua, fare attenzione a non
rovesciare acqua sul dispositivo.
ATTENZIONE: Non spostare il dispositivo quando il serbatoio contiene acqua.
Figura 3
-
2
Figura 3
-
1
Figura 3
-
4
Figura 3
-
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Apex Digital iCH Prime Manuel utilisateur

Catégorie
Humidificateurs
Taper
Manuel utilisateur