6
67
7
• Be extra careful to avoid dropping a metal tool onto the battery. It might spark or
short-circuit the battery or another electrical part and could cause an explosion.
• Jump-start procedures should only be performed in a safe, dry, well-ventilated area.
• Always store battery clamps when not in use. Never touch battery clamps
together. This can cause dangerous sparks, power arcing and/or explosion.
• When using this unit close to the vehicle’s battery and engine, stand the unit on a
flat, stable surface, and be sure to keep all clamps, cords, clothing and body parts
away from moving vehicle parts.
• Never allow red and black clamps to touch each other or another common metal
conductor — this could cause damage to the unit and/or create a sparking/
explosion hazard.
– For negative-grounded systems, connect the positive (red) clamp to the
positive ungrounded battery post and the negative (black) clamp to the vehicle
chassis or engine block away from the battery. Do not connect the clamp to the
carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage metal
part of the frame or engine block.
– For positive-grounded systems, connect the negative (black) clamp to the
negative ungrounded battery post and the positive (red) clamp to the vehicle
chassis or engine block away from the battery. Do not connect the clamp to the
carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage metal
part of the frame or engine block.
• If the clamps are connected incorrectly with regard to polarity, the backlit LCD
screen will display the Battery Status Icon, Battery Voltage Indicator, and the
Clamp Icons. The Alarm Icon, the “+” and ”–” signs and the Reverse Polarity
Icons will flash and the unit will sound a continuous alarm until the clamps
are disconnected. Disconnect the clamps and reconnect to battery with correct
polarity.
• Always disconnect the negative (black) jumper cable first, followed by the positive
(red) jumper cable, except for positive grounded systems.
• Do not expose battery to fire or intense heat since it may explode. Before
disposing of the battery, protect exposed terminals with heavy-duty electrical tape
to prevent shorting (shorting can result in injury or fire).
• Place this unit as far away from the battery as cables permit.
• Never allow battery acid to come in contact with this unit.
• Do not operate this unit in a closed area or restrict ventilation in any way.
• This system is designed to be used only on vehicles with a 12 volt DC battery
system. Do not connect to a 6 volt or 24 volt battery system.
• This system is not designed to be used as a replacement for a vehicular battery.
Do not attempt to operate a vehicle that does not have a battery installed.
• Excessive engine cranking can damage a vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedures and look for other problems that may need to be corrected.
• Do not use this jump starter on a watercraft. It is not qualified for marine
applications.
• Although this unit contains a non-spillable battery, it is recommended that unit
be kept upright during storage, use and recharging. To avoid possible damage
that may shorten the unit’s working life, protect it from direct sunlight, direct heat
and/or moisture.
SPECIFIC SAFETY INSTRUCTIONS FOR
INVERTERS
WARNING – TO REDUCE THE RISK OF ELECTRIC SHOCK:
• Do not connect to AC distribution wiring.
• Do not make any electrical connections or disconnections in areas designated as
IGNITION PROTECTED. This inverter is NOT approved for ignition protected areas.
• Never immerse the unit in water or any other liquid, or use when wet.
• Do not insert foreign objects into the unit’s AC outlet.
WARNING – TO REDUCE THE RISK OF FIRE:
• Do not operate near flammable materials, fumes or gases.
• Do not expose to extreme heat or flames.
CAUTION – TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• Disconnect appliance plug from inverter outlet before attempting any repairs to
the appliance.
• When an appliance plugged into this unit is used outdoors, use only extension
cords intended for use outdoors and so marked.
• Do not attempt to connect the inverter while operating your vehicle. Not paying
attention to the road may result in a serious accident.
• Always use the inverter where there is adequate ventilation.
• Always turn the inverter off when not in use.
• Keep in mind that this inverter will not operate high wattage appliances or
equipment that produce heat, such as hair dryers, microwave ovens and toasters.
• Do not use this inverter with medical devices. It is not tested for medical
applications.
• Some laptop computers may not operate with this inverter.
• Operate inverter only as described in this Instruction Manual.
CAUTION: RECHARGEABLE DEVICES
• Certain rechargeable devices are designed to be charged by plugging them
directly into an AC receptacle. These devices may damage the inverter or the
charging circuit.
• When using a rechargeable device, monitor its temperature for the initial ten
minutes of use to determine if it produces excessive heat.
• If excessive heat is produced, this indicates the device should not be used with
this inverter.
• This problem does not occur with most of the battery-operated equipment. Most
of these devices use a separate charger or transformer that is plugged into an
AC receptacle.
• The inverter is capable of running most chargers and transformers.
SPECIFIC SAFETY INSTRUCTIONS FOR
THE USB PORTS
• Do not insert foreign objects into the USB Ports.
• Do not attach USB hubs or more than one personal electronic device to each
USB Port.
• Do not use this unit to operate appliances that require more than 6.2 amps in
total to operate from the USB Ports.
• Some household USB-powered electronics will not operate with this unit.
SPECIFIC SAFETY INSTRUCTIONS FOR
COMPRESSORS
CAUTION – TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• Never leave the compressor unattended while in use.
• Do not operate compressor continuously for longer than approximately 10
minutes, depending on ambient temperatures, as it may overheat. This could
damage the compressor. Follow the instructions in the “Portable Compressor”
section.
WARNING – BURST HAZARD: Bursting articles can cause serious injury.
• Carefully follow instructions on articles to be inflated.
• Never exceed the recommended pressure listed in instructions on articles to be
inflated. If no pressure is given, contact article manufacturer before inflating.
• Monitor the pressure at all times on the LCD screen.
PERSONAL SAFETY
When working with lead acid batteries, always make sure immediate assistance is
available in case of accident or emergency.
Always have protective eyewear when using this product: contact with battery acid
may cause blindness and/or severe burns. Be aware of first aid procedures in case
of accidental contact with battery acid.
Avoid touching the eyes while working with a battery. Acid, acid particles or
corrosion may get into the eyes.
Have plenty of fresh water and soap nearby in case battery acid contacts skin.
Remove personal metal items such as rings, bracelets, necklaces and watches
when working with a lead-acid battery. A lead-acid battery can produce a short
circuit current high enough to cause a severe burn.
Be extra cautious to reduce the risk of dropping a metal object onto the battery.
This might cause sparks or short-circuit the battery or other electrical part, which
can cause an explosion.
Warning! Battery fluid is a diluted sulphuric acid and may cause personal
injury or damage to property. In case of skin or eye contact, follow the instructions
below.
• Skin: If battery acid comes in contact with skin, rinse immediately with water,
then wash thoroughly with soap and water. If redness, pain, or irritation occurs,
seek immediate medical attention.
• Eyes: If battery acid comes in contact with eyes, flush eyes immediately, for a
minimum of 15 minutes and seek immediate medical attention.
• LCD liquid crystal display: If liquid crystal comes in contact with your skin:
Wash area off completely with plenty of water. Remove contaminated clothing.
If liquid crystal gets into your eye: Flush the affected eye with clean water and
then seek medical attention. If liquid crystal is swallowed: Flush your mouth
thoroughly with water. Drink large quantities of water and induce vomiting. Then
seek medical attention.
SAVE THESE INSTRUCTIONS
INTRODUCTION
Congratulations on purchasing your new professional digital power station. Read
this Instruction Manual and follow the instructions carefully before using this unit.
OVERVIEW
Common Actions and Unit Responses
The following actions turn the unit on and activate the LCD screen:
Press the LED Area Light
Power Button. (Refer to
the “LED Area Light”
section.)
A beep will sound and the Area Light will turn on.
The backlight will turn on for 10 seconds (only).
The LCD screen will continue to display the Battery
Status Icon and Battery Voltage Indicator. The unit
remains on until the LED Area Light Power Button is
pressed again to turn it off.
Press the AC Power
Button. (Refer to the “120V
AC Power Outlet” section.)
A beep will sound and the backlit LCD screen will
display the Battery Status Icon and the Digital
Display shows “AC”, indicating the AC outlet is ready
to use. The unit remains on until the AC Power
Button is pressed again to turn it off.
Press the USB Power
Button. (Refer to the "USB
Ports" section.)
A beep will sound and the USB Ports will turn on.
The backlight will turn on for 10 seconds (only).
The LCD screen will display the Battery Status Icon,
Battery Voltage Indicator, and the USB Icon; and
the USB Power/Fault Indicators will light solid blue
indicating the four USB Ports are active. The unit
remains on until the USB Power Button is pressed
again to turn it off.
Press the Compressor
Power Button. (Refer to
the “Portable Compressor”
section.)
A beep will sound and the backlit LCD screen will
display the Battery Status Icon, "XXX" PSI and the
Compressor Icon. If no further actions are taken
after 1 minute, the unit will display the Battery
Status Icon and Battery Voltage Indicator for 10
seconds before automatically turning off.
Whenever the clamps are
properly connected to a
battery (refer to the “Jump
Starter” section) …
… a beep will sound and the backlit LCD screen
will display the Battery Status Icon, Battery Voltage
Indicator, the Clamp Icons, and the “+” and ”–”
signs, as well as the flashing Jump Starter Icon. The
unit remains on until the clamps are disconnected
from the battery.
If the Jump Starter Power
Switch is rotated to the on
position and the clamps
are not connected to a
battery (refer to the “Jump
Starter” section) …
... a two-second warning will sound every 10
seconds. The backlit LCD screen will display the
Battery Status Icon, Battery Voltage Indicator,
the Clamp Icons, and the “+” and ”–” signs. The
Alarm Icon and the Jump Starter Icon will flash.
The unit remains on until the Jump Starter Power
Switch is switched off and then displays the battery
status icon and the voltage of digital display for 10
seconds before automatic shut down.
If the clamp connections
to the battery’s positive
and negative terminals
are reversed (refer to the
"Jump Starter" section) …
… the backlit LCD screen will display the Battery
Status Icon, Battery Voltage Indicator, and the Clamp
Icons. The Alarm Icon, the “+” and ”–” signs and
the Reverse Polarity Icons will flash and the unit will
sound a warning continuously until the clamps are
disconnected from the battery.
When the unit is charging
or recharging using
the built-in 120 Volt AC
Charger (refer to the
"Charging/Recharging"
section) …
… the backlight will turn on for 10 seconds (only).
The LCD screen will continue to display the Battery
Status Icon and Battery Voltage Indicator. The bars
on the Battery Status Icon will change from empty
to solid (bottom to top) repeatedly.
Note: The unit will automatically power off once ALL the functions are turned off.
VIEWING BATTERY STATUS
The Battery Status Icon and Battery Voltage Indicator indicate the battery charge
level as follows.
• If the battery charge level is at full capacity, four solid bars will display.
• If the battery is partially charged, two or three solid bars will display.
• If the battery is nearly empty, one solid bar will display. The unit should be
charged at this time.
• If the battery is completely empty, four blank bars will display. The unit MUST be
charged at this time or the unit’s built-in low voltage protection will activate. The
empty Battery Status Icon will flash for a short period of time before automatic
shut down. The unit will not operate until the battery is recharged.
CHARGING/RECHARGING
This unit is delivered in a partially charged state – you must fully charge it before
using it for the first time. Initial AC charge should be for 40 hours or until the
Battery Status Icon shows 4 solid bars.
Lead-acid batteries require routine maintenance to ensure a full charge and long
battery life. All batteries lose energy from self-discharge over time and more
rapidly at higher temperatures. Therefore, batteries need periodic charging to
replace energy lost through self-discharge. When the unit is not in frequent use,
manufacturer recommends the battery should be recharged at least every 30 days
and after each use.
CAUTION – RISK OF PROPERTY DAMAGE: Failure to keep the battery charged
will cause permanent damage and result in poor jump starting performance.
IMPORTANT NOTES:
• Recharging the battery after each use will prolong battery life; frequent heavy
discharges between recharges and/or overcharging will reduce battery life.
• Make sure all other unit functions are turned off during recharging, as this can
slow the recharging process.
• If you know the unit is discharged, but the battery icon displays four solid bars
as if the unit is fully charged when connected to a charging power source, this
may be due to the internal battery having high impedance. The manufacturer
suggests leaving the unit charging for a period of 40 hours using the built-in AC
charger before use.
Charging/Recharging Using the Built-In 120 Volt AC
Charger and AC Extension Cord (may be sold separately)
1. Lift the protective cover of the built-in 120 Volt AC Charger (refer to the
“Features section to locate). Connect an extension cord to the unit. Plug the
other end of the cord into a standard 120-volt AC wall outlet. When the unit
is properly connected to an AC power source, the LCD screen will display the
following:
The bars on the Battery Status Icon represent the charge level of the unit’s
internal battery. The bars on the Battery Status Icon will change from empty to
solid (bottom to top) repeatedly to indicate the unit is charging. The backlight
will turn on for 10 seconds (only).
2. Charge for approximately 40 hours or until the Battery Status Icon shows 4
solid bars.
3. When charging is complete, unplug the AC extension cord from the AC outlet
and then disconnect it from the unit.
JUMP-STARTER
This unit is equipped with a jump starter power switch that allows energy to flow
only when proper connections are made to battery and frame.
A. For negative-grounded systems, connect the positive (red) clamp to the
positive ungrounded battery post and the negative (black) clamp to the vehicle
chassis or engine block away from the battery. Do not connect the clamp to the
carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage metal
part of the frame or engine block.
B. For positive-grounded systems, connect the negative (black) clamp to the
negative ungrounded battery post and the positive (red) clamp to the vehicle
chassis or engine block away from the battery. Do not connect the clamp to the
carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gage metal
part of the frame or engine block.
IMPORTANT: Make sure the Compressor Power Button has been turned off before
attempting to use the unit as a Jump Starter.
WARNING – TO REDUCE THE RISK OF SERIOUS INJURY OR PROPERTY
DAMAGE:
• Follow all safety instructions found in the “Specific Safety Instructions for Jump
Starters” section of this instruction manual.
• Never touch red and black clamps together. This can cause dangerous sparks,
power arcing, and/or explosion.
• If the clamps are connected incorrectly with regard to polarity, the unit will sound
a continuous alarm until the clamps are disconnected. The backlit LCD Screen will
display the Battery Status Icon, the Battery Voltage Indicator and the Clamp Icons.
The “+” and ”–” signs above the Clamp Icons, the Arrow Icons and the Alarm
Icon will flash. The backlit LCD screen will display the following:
CJ1000DXT_ManualENFRSP_ 032421.indd 6-7CJ1000DXT_ManualENFRSP_ 032421.indd 6-7 3/24/2021 11:07:37 AM3/24/2021 11:07:37 AM