NuTone 763NC Manuel utilisateur

Taper
Manuel utilisateur
!
FAN/LIGHT COMBINATION VENTILATOR / VENTILATEUR À ÉCLAIRAGE COMBINÉ
MODEL / MODÈLE 763NC
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact
the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock the service discon-
necting means to prevent power from being
switched on accidentally. When the service dis-
connecting means cannot be locked, securely
fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the Ameri-
can Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or shower,
it must be marked as appropriate for the appli-
cation and be connected to a GFCI (Ground Fault
Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached
from a tub or shower.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2. This product is designed for ceiling installation
only. This product is designed for installation
in ceilings up to a 12/12 pitch. Ductwork must
point up. DO NOT MOUNT THIS PRODUCT IN
A WALL.
3. To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
4. Please read specification label on product for
further information and requirements.
Installer: Leave this manual with the
homeowner. Homeowner: Use and Care
information on page 4.
READ AND SAVE
THESE INSTRUCTIONS
TYPICAL INSTALLATIONS
HOUSING
CEILING
JOIST
MOUNTING TABS
GRILLE
CEILING
MATERIAL
POWER CABLE
HOUSING
CEILING
JOIST
MOUNTING TABS
GRILLE
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
HOUSING MOUNTED TO ADDITIONAL FRAMING
Discharge 90
0
to joists.
HOUSING MOUNTED DIRECTLY TO JOIST
2x6 (or larger) Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING
TABS
CEILING
MATERIAL
POWER CABLE
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge parallel to joists.
HOUSING
MOUNTING
TABS
CEILING
MATERIAL
POWER CABLE
ADDITIONAL
FRAMING
"
I
"
JOIST
"
I
"
JOIST
GRILLE
HOUSING MOUNTED TO “I” JOIST
Requires additional framing for mounting tabs.
Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING TABS
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge 90
0
to joists.
HOUSING
MOUNTING TABS
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
"
I
"
JOIST
"
I
"
JOIST
GRILLE
HOUSING MOUNTED TO “I” JOIST
Requires additional framing for mounting tabs.
Discharge 90
0
to joists.
* Additional framing must be a 2x6 (minimum height).
*
*
*
*
AVERTISSEMENT
OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN
DE RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES CORPORELLES :
1. N’utilisez cet appareil que de la manière prévue par le
fabricant. Si vous avez des questions, communiquez
avec le fabricant à l’adresse ou au numéro de
téléphone indiqués dans la garantie.
2. Avant de procéder à l’entretien ou au nettoyage de
l’appareil, coupez l’alimentation du panneau électrique
et verrouillez l’interrupteur principal afin d’empêcher
que le courant ne soit accidentellement rétabli. S’il
est impossible de verrouiller l’interrupteur principal,
fixez solidement un message d’avertissement, par
exemple une étiquette, sur le panneau électrique.
3. La pose de l’appareil et les travaux d’électricité
doivent être effectués par des personnes qualifiées
conformément à la réglementation en vigueur,
notamment les normes de la construction ayant trait
à la protection contre les incendies.
4. Pour éviter les refoulements, l’apport d’air doit
être suffisant pour brûler les gaz produits par
les appareils à combustion et les évacuer dans
le conduit de fumée (cheminée). Respectez les
directives du fabricant de l’appareil de chauffage et
les normes de sécurité, notamment celles publiées
par la National Fire Protection Association (NFPA),
l’American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE) et les codes des
autorités locales.
5. Veillez à ne pas endommager le câblage électrique
ou d’autres équipements non apparents lors de la
découpe ou du perçage du mur ou du plafond.
6. Les ventilateurs canalisés doivent toujours rejeter
l’air à l’extérieur.
7. Si cet appareil doit être installé au-dessus d’une
enceinte de baignoire ou de douche, il doit comporter
les mentions appropriées pour ces utilisations et doit
être branché sur un circuit de dérivation protégé par
un disjoncteur de mise à la terre.
8. Ne jamais placer un interrupteur de sorte que l’on
puisse l’atteindre d’une baignoire ou d’une douche.
9. Cet appareil doit être relié à une mise à la terre.
ATTENTION
1. Pour ventilation générale uniquement. N’utilisez
pas cet appareil pour évacuer des matières ou des
vapeurs dangereuses ou explosives.
2. Ce produit ne convient qu’à une pose dans un plafond
et peut être installé dans un plafond dont la pente
n’excède pas 12/12. Les conduits doivent pointer
vers le haut. CE PRODUIT NE PEUT PAS ÊTRE POSÉ
DANS UN MUR.
3. Pour éviter d’endommager les roulements du
moteur, de déséquilibrer les pales ou de les rendre
bruyantes, débarrassez l’appareil de la poussière de
plâtre, de construction, etc.
4. Veuillez lire l’étiquette de spécifications du produit
pour obtenir plus de renseignements, notamment
sur les exigences.
Installateur : Veuillez remettre ce
manuel au propriétaire. Propriétaire :
Voir le mode d’utilisation et d’entretien
à la page 4.
!
LIRE CES DIRECTIVES
ET LES CONSERVER
*
2
BOÎTIER
FIL
D’ALIMENTATION
CONDUIT
ROND DE
10,2 cm (4 po)
GRILLE
SOLIVES DU
PLAFOND ou
FERMES
DE 2 x 4
ERGOTS DE MONTAGE
MATÉRIAU
DU PLAFOND
CADRAGE
SUPPLÉ-
MENTAIRE*
SOLIVES DU
PLAFOND ou
FERMES
DE 2 x 4
BOÎTIER
SOLIVE
DU
PLAFOND
ERGOTS DE
MONTAGE
GRILLE
MATÉRIAU
DU PLAFOND
FIL D’ALIMENTATION
BOÎTIER DIRECTEMENT FIXÉ AUX SOLIVES
Solives de 2x6 (ou plus) Sortie parallèle aux solives.
BOÎTIER FIXÉ À UN CADRE SUPPLÉMENTAIRE
Sortie à 90° des solives.
BOÎTIER
SOLIVES DU
PLAFOND ou
FERMES
DE 2 x 4
ERGOTS DE
MONTAGE
MATÉRIAU
DU PLAFOND
FIL D’ALIMENTATION
CADRAGE
SUPPLÉMENTAIRE*
GRILLE
SOLIVES DU
PLAFOND ou
FERMES
DE 2 x 4
BOÎTIER FIXÉ AUX FERMES DE 2x4
Les ergots de montage exigent un cadre supplémentaire.
Sortie parallèle aux solives.
BOÎTIER FIXÉ AUX FERMES DE 2x4
Les ergots de montage exigent un cadre supplémentaire.
Sortie à 90° des solives.
BOÎTIER
FIL D’ALIMENTATION
SOLIVE EN
« I »
ERGOTS DE
MONTAGE
MATÉRIAU
DU PLAFOND
CADRAGE
SUPPLÉMENTAIRE*
GRILLE
SOLIVE EN
« I »
CONDUIT
ROND DE
10,2 cm (4 po)
BOÎTIER
FIL
D’ALIMENTATION
SOLIVE EN
« I »
ERGOTS DE MONTAGE
MATÉRIAU
DU PLAFOND
CADRAGE
SUPPLÉMENTAIRE*
GRILLE
SOLIVE EN
« I »
BOÎTIER FIXÉ À UNE SOLIVE EN « I »
Les ergots de montage exigent un cadre supplémentaire.
Sortie parallèle aux solives.
BOÎTIER FIXÉ À UNE SOLIVE EN « I »
Les ergots de montage exigent un cadre supplémentaire.
Sortie à 90° des solives.
* Le cadre supplémentaire doit être en
2x6 (hauteur minimale).
TYPICAL INSTALLATIONS
MOUNTING
TAB
GRILLE
SUSPENDED
CEILING MATERIAL
POWER
CABLE
4" ROUND
DUCT
HOUSING
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
- PLEASE NOTE -
THE FOLLOWING INSTALLATION ILLUSTRATIONS
SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR
“I”-JOIST INSTALLATION, MOUNT THE VENTI-
LATOR TO THE ADDITIONAL FRAMING IN THE
SAME MANNER. (Additional framing must be a
2x6 (minimum height).
1. Choose the location for your fan in the ceil-
ing. For best possible performance, use the
shortest possible duct run and a minimum
number of elbows.
2. Position mounting
brackets against joist
so that bottom edge of
housing will be flush
with finished ceiling.
Additional positioning
feature for 5/8”, 1”,
& 1-1/4” thick ceiling
material:
Holes in corners of
housing are labeled with various ceiling
material thicknesses. Position housing so
bottom edge of joist is visible through a
matched set of holes. The housing is now in
the proper position for that ceiling material
thickness.
Additional positioning feature for 1/2” thick
ceiling material:
Bend two tabs, on side of housing,
90
0
outward.
Lift housing until tabs contact underside of
joist.
Mark the keyhole slot on both mounting
brackets.
New Construction
5/8
1
1-1/4
TAB
ERGOT
HOLES
TROUS
BOTTOM EDGE OF JOIST
DESSOUS DE LA SOLIVE
3. Set housing aside and
drive nails partially into
joist at the top of both
keyhole marks.
4. Hang housing from nails
and pound nails tight.
To ensure a noise-free
mount, pound another
nail through the top hole
of each mounting tab.
INSTALLATIONS TYPE
ERGOT DE
MONTAGE
GRILLE
MATÉRIAU DU
PLAFOND SUSPENDU
FIL
D’ALIMENTATION
CONDUIT
ROND DE
10,2 cm (4 po)
BOÎTIER
INSTALLATION DU BOÎTIER
PLAFONDS SUSPENDUS
Boîtier suspendu à des ls de fer en 3 points.
- VEUILLEZ NOTER -
LES ILLUSTRATIONS SUIVANTES MONTRENT UNE
INSTALLATION SUR DES SOLIVES DE 2 X 6. SI
L’INSTALLATION EST FAITE SUR DES FERMES OU DES
POUTRES EN « I », MONTEZ LE VENTILATEUR DE LA
MÊME FAÇON SUR UN CADRE. (Le cadre supplémentaire
doit être en 2x6 [hauteur minimale]).
1. Choisissez l’emplacement du ventilateur au plafond.
Pour obtenir un rendement optimal, utilisez un
minimum de conduits et de coudes.
Construcción nueva
2. Positionnez les brides de
montage contre la solive,
de sorte que le bas du boîtier
affleure la surface finie
du plafond.
Positionnement
supplémentaire dans des
plafonds de 1,6 cm (5/8 po),
2,5 cm (1 po) et 3,2 cm
(1-1/4 po) d’épaisseur :
Des trous sont marqués
3. Mettez le boîtier de côté
et enfoncez partiellement
un clou dans le haut des
marques en trous de serrure.
4. Suspendez le boîtier aux
clous puis enfoncez-les
complètement. Pour
assurer un fonctionnement
silencieux, enfoncez un
autre clou dans le trou
supérieur de chaque bride.
Construction neuve
INSTALLATIONS TYPE
dans les coins pour différentes épaisseurs
de plafond. Placez le boîtier de sorte que le
dessous de la solive soit visible dans la série de
trous correspondante. Le boîtier est alors dans
la position adéquate pour cette épaisseur
de plafond.
Positionnement supplémentaire dans un
plafond de 1,3 cm (1/2 po) d’épaisseur :
Dépliez deux ergots sur les côtés du boîtier, à
90° vers l’extérieur. Soulevez le boîtier afin que
les ergots s’appuient contre le dessous de la
solive.
Marquez le trou en forme de serrure sur
chaque bride.
3
1. Choose the location for your fan/light in the ceiling. For
best possible performance, use the shortest possible
duct run and a minimum number of elbows.
2. In attic, position mounting brackets against joist. Trace
outline of housing on ceiling material.
3. Set housing aside and cut ceiling opening slightly larger
than marked.
4. Place housing in opening so that its bottom edge is flush
with finished ceiling. Nail to joist through keyhole on both
sides. To ensure a noise-free installation, drive another
nail through the top hole of each mounting bracket.
5. Additional mounting holes are provided for installations
where access from above is inconvenient or not possible.
Nail or screw housing directly to joists or framing.
INSTALL THE HOUSING
INSTALL THE DUCTWORK
NOTE: The duct connector has a counter-balanced damper flap.
The flap will be “open” approx. 1” when duct connector is at-
tached to housing. This design permits insulation to be in direct
contact with fan/light housing per UL (Underwriters Laboratories)
standards. The slightest backdraft, however, will close the damper
flap, preventing air from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure
that tabs on the connector lock into slots in housing. Top of
damper/duct connector should be flush with top of housing.
2. Connect 4” round duct to damper/duct connector and extend
duct to outside through a roof or wall cap. Check damper to
make sure that it opens freely. Tape all duct connections to
make them secure and air tight.
Existing Construction
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING
PLATE
120 VAC
LINE IN
BLUE
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
CONNECT THE WIRING
1. Slide light reflector into front of grille opening. Plug light
into WHITE receptacle. Place grille / reflector combination
over protruding screw, and fasten in place using acorn nut
provided. HAND TIGHTEN acorn nut 1/4 turn after it is snug.
NOTE: If grille and light reflector are not snug to ceiling, use
a nut driver or pliers on acorn nut to snug grille to ceiling.
2. Install light bulb (not included). (See next page for type
and size for your model.) Insert one tab on light lens into
a slot in the grille / reflector combination. Squeeze other
tab slightly and snap into remaining slot.
ATTACH THE GRILLE
1. Wire unit following diagram. Run electrical cable as direct
as possible to unit. Do not allow cable to touch sides or
top of unit after installation is complete.
INSTALLATION DU BOÎTIER
1. Choisissez l’emplacement du ventilateur à éclairage dans
le plafond. Pour obtenir un rendement optimal, utilisez un
minimum de conduits et de coudes.
2. Dans le grenier, positionnez les brides de montage contre la
solive. Tracez le contour du boîtier sur le matériau du plafond.
3. Mettez le boîtier de côté et découpez l’ouverture légèrement
plus grande que tracée.
4. Placez le boîtier dans l’ouverture de sorte que son arête
inférieure affleure la surface finie du plafond. Clouez chaque
bride à la solive à travers les trous en forme de serrure. Pour
assurer un fonctionnement silencieux, enfoncez un autre clou
dans le trou supérieur de chaque bride.
5. Des trous de fixation supplémentaires sont prévus pour les
installations où l’accès du dessus est difficile ou impossible.
Vissez ou clouez le boîtier directement aux solives ou au cadre.
Habitation déjà construite
POSE DU CONDUIT
REMARQUE : Le raccord du conduit est muni d’un clapet à
contrepoids. Le clapet demeurera ouvert d’environ 2,5 cm (1 po)
une fois le raccord fixé au boîtier. L’isolation est ainsi directement
en contact avec le boîtier du ventilateur et de la lampe,
conformément aux normes UL (Underwriters Laboratories).
Par contre, au moindre refoulement d’air, le clapet se referme,
empêchant l’air de pénétrer dans le ventilateur et dans la pièce.
1. Enclenchez le clapet / raccord de conduit sur le boîtier. Assurez-
vous que les languettes du raccord s’enclenchent correctement
dans les fentes du boîtier. Le dessus du clapet / raccord de
conduit doit être de niveau avec le dessus du boîtier.
2. Raccordez un conduit rond de 10,2 cm (4 po) au clapet / raccord
de conduit et acheminez le conduit à l’extérieur à travers un
capuchon de toit ou une sortie murale. Vérifiez que le clapet
du registre s’ouvre librement. Étanchez tous les joints avec du
ruban adhésif.
ADDITIONAL MOUNTING HOLES
TROUS DE FIXATION SUPPLÉMENTAIRES
FIXATION DE LA GRILLE
1. Glissez le réflecteur d’éclairage dans la face avant de l’ouverture
de la grille. Branchez l’éclairage dans la prise BLANCHE. Placez la
grille et son réflecteur sur la vis qui dépasse et fixez le tout avec
l’écrou borgne. Serrez l’écrou À LA MAIN d’un quart de tour après
avoir senti une certaine résistance. REMARQUE : Si la grille et le
réflecteur ne sont pas bien appuyés contre le plafond, serrez l’écrou
borgne avec un tourne-écrou ou des pinces.
2. Posez l’ampoule (non incluse). (Voir à la page suivante le type et
la taille qui correspondent à votre modèle.) Insérez un ergot de la
lentille dans une fente de la grille / réflecteur. Enfoncez l’autre ergot
légèrement jusqu’à son enclenchement dans l’autre fente.
1. Connectez l’appareil tel qu’indiqué dans le diagramme.
Acheminez le câble électrique le plus directement possible à
l’appareil. Veillez à ce que le câble ne touche pas les côtés ni
le dessus du boîtier, une fois la pose terminée.
RACCORD DU CÂBLAGE
FLUSH
ÉGAL
BOÎTE
D’INTERRUPTEUR
ÉCLAIRAGE
VENTILATEUR
DOUBLE COMMANDE
(vendue séparément)
BLANC
NOIR
ROUGE
TERRE
(nu)
PLAQUE DE
CÂBLAGE
ENTRÉE 120 VCA
BLEU
PRISE
BLANCHE (LUM.)
PRISE NOIRE
(VENT.)
BLK
VENT
SWITCH
BLU
BLK
WHT
WHT
WHT
LIGHT
(WHITE)
GRD
VENT
(BLACK)
UNIT
SWITCH BOX
LIGHT
SWITCH
LINE
IN
BLK
RED
WHT
GRD
NOIR
INTERRUPTEUR
DE VENTILATEUR
BLEU
NOIR
BLANC
LUM.
(BLANC)
TERRE
VENT.
(NOIR)
APPAREIL
BOÎTE D’INTERRUPTEUR
INTERRUPTEUR
D’ÉCLAIRAGE
ENTRÉE
NOIR
ROUGE
BLANC
TERRE
BLANC
BLANC
KEY NO./ PART NO./
N° DE REPÈRE N° DE PIÈCE DESCRIPTION / DESCRIPTION
1 99111381 Light Lens / Lentille d’éclairage
2 97005316 Acorn Nut / Écrou borgne
3 99770029 Bulb Holder / Douille d’ampoule
4 97014211 Light Reflector / Réflecteur de lumière
* 97014212 Light Reflector Assembly (includes Key Nos. 3 & 4)
Ensemble de plafonnier d’éclairage (comprend repères nos 3 et 4)
5 99111380 Grille / Grille
6 97014926 Motor Plate / Plaque de moteur
7 99080738 Motor / Moteur
8 99111002 Impeller / Roue à ailettes
9 99260428 Motor Nut (2 req.) / Écrou de moteur (2 néces.)
10 99150582 Grille Screw / Vis de grille
* 97020199 Blower Assembly (Includes Key Nos. 6, 7, 8, 9, 10)
Ensemble de ventilateur (comprend repères nos 6, 7, 8, 9, 10)
11 99270982 Receptacle (Black) / Prise (noire)
12 99270981 Receptacle (White) / Prise (blanche)
13 98009612 Wire Panel / Panneau de connexion
* 97015171 Wire Panel Assembly (includes Key Nos. 11, 12, 13)
Ensemble de panneau de connexion (comprend repères nos 11, 12, 13)
14 97014922 Housing / Boîtier
15 97014185 Damper / Duct Connector / Clapet / raccord de conduit
16 98008868 Wiring Plate / Plaque de câblage
17 99150575 Screw, #8-18 x .375 / Vis n° 8-18 x 0,375
18 99150471 Ground Screw / Vis de mise à la terre
* Not shown assembled.
Order replacement parts by “PART NO.” - not by “KEY NO.”
* Illustré démonté.
Veuillez commander les pièces de rechange par « N° DE PIÈCE » et non par « N° DE REPÈRE ».
USE AND CARE
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT.
BULB REPLACEMENT
Remove lens by gently depressing sides and pull down.
Use 100 Watt maximum incandescent bulb.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
CLEANING
TO CLEAN LENS AND GRILLE:
Remove light lens and bulb. Remove nut in center of reflector and lower assembly.
CAUTION: Grille and reector are separate units. Unplug light from WHITE
receptacle. Plastic parts can be cleaned with mild, soapy water (use a mild
detergent, such as dishwashing liquid) and dried with a soft cloth. Do not
use abrasive cloth, steel wool pads, or scouring powders.
TO CLEAN FAN ASSEMBLY:
Unplug fan assembly (BLACK receptacle). To remove motor plate: Find the single tab
on the motor plate (located next to the receptacles). Push up near motor plate tab
while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in
housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of
housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
WARRANTY
99045583A
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of one year from
the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES,
HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL
CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S
OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary
from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or
telephone number below, (b) give the model number and part identification and (c) describe
the nature of any defect in the product or part. At the time of requesting warranty service,
you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.nutone.com 800-558-1711
GARANTIE
GARANTIE LIMITÉE D’UN AN BROAN-NUTONE
Broan-NuTone garantit à l’acheteur original que les produits vendus en vertu de la présente sont libres de tout
vice de matériau ou de fabrication pour une période d’un an à compter de la date d’achat originale. CETTE
GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE, Y COMPRIS, MAIS SANS S’Y
LIMITER, LES GARANTIES TACITES DE VALEUR MARCHANDE OU D’ADAPTATION À UN USAGE PARTICULIER.
Durant cette période d’un an, Broan-NuTone réparera ou remplacera gratuitement, à sa discrétion, tout produit
ou toute pièce jugés défectueux dans des conditions normales d’utilisation.
CETTE GARANTIE NE S’APPLIQUE PAS AUX TUBES FLUORESCENTS ET AUX DÉMARREURS, NI AUX
AMPOULES HALOGÈNES OU INCANDESCENTES, FUSIBLES, FILTRES, CONDUITS, CAPUCHONS DE TOIT,
CAPUCHONS MURAUX ET AUTRES ACCESSOIRES POUR CONDUITS. Cette garantie ne couvre pas (a) les
frais d’entretien ou de service normaux ni (b) tout produit ou toute pièce soumis à un abus, une négligence,
un accident, un entretien ou une réparation inadéquats (autres que ceux effectués par Broan-NuTone), une
mauvaise installation ou une installation contraire aux instructions recommandées.
La durée de toute garantie tacite est limitée à la période d’un an stipulée pour la garantie expresse. Certains
territoires ou provinces interdisant de limiter la durée d’une garantie tacite, la limitation ci-dessus peut ne
pas s’appliquer à votre situation.
L’OBLIGATION POUR BROAN-NUTONE DE RÉPARER OU DE REMPLACER LE PRODUIT, À SA DISCRÉTION,
CONSTITUE LE SEUL RECOURS DE L’ACHETEUR EN VERTU DE LA PRÉSENTE GARANTIE. BROAN-NUTONE
NE PEUT ÊTRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS OU CONSÉCUTIFS NI DES DOMMAGES-
INTÉRÊTS PARTICULIERS DÉCOULANT DE L’UTILISATION OU DU RENDEMENT DU PRODUIT. Certains
territoires ou provinces ne permettant pas la limitation ou l’exclusion des dommages indirects ou consécutifs,
la limitation ci-dessus peut ne pas s’appliquer à votre situation.
La présente garantie vous confère des droits spécifiques reconnus par la loi. D’autres droits pourraient
également vous être accordés selon la législation locale en vigueur. La présente garantie remplace toutes les
autres garanties précédentes.
Pour vous prévaloir de cette garantie, vous devez (a) aviser Broan-NuTone à l’adresse ou au numéro de
téléphone indiqués ci-dessous, (b) donner le numéro de modèle du produit et le numéro d’identification de la
pièce et (c) décrire la nature de la défectuosité du produit ou de la pièce. Lors de votre demande de garantie,
vous devez présenter une preuve de la date d’achat originale.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119
AVERTISSEMENT : DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE ET VERROUILLEZ LE
PANNEAU ÉLECTRIQUE AVANT DE NETTOYER OU DE RÉPARER L’APPAREIL.
REMPLACEMENT DES AMPOULES
Retirez la lentille en enfonçant légèrement ses côtés et en la tirant vers le bas.
Utilisez une ampoule incandescente de 100 watts maximum.
LUBRIFICATION DU MOTEUR
Le moteur est lubrifié en permanence. Il ne doit pas être huilé ni démonté.
NETTOYAGE
NETTOYAGE DE LA LENTILLE ET DE LA GRILLE :
Retirez la lentille d’éclairage et l’ampoule. Dévissez l’écrou au centre du réflecteur et abaissez
le tout.
ATTENTION : La grille et le réecteur sont des éléments distincts. Débranchez la lumière
de la prise BLANCHE. Les pièces de plastique peuvent être nettoyées à l’eau savonneuse
(avec un détergent doux comme du liquide à vaisselle) puis asséchées avec un chiffon doux.
N’utilisez pas de chiffons abrasifs, de laine d’acier ni de poudre à récurer.
NETTOYAGE DU VENTILATEUR :
Débranchez le ventilateur (prise NOIRE). Pour retirer la plaque du moteur : Trouvez l’ergot
sur la plaque du moteur (à proximité de la prise). Soulevez l’ergot tout en poussant sur les
côtés du boîtier. Ou encore, insérez la lame d’un tournevis plat dans la fente du boîtier (à côté
de l’ergot) et tournez le tournevis. À l’aide d’un aspirateur, nettoyez délicatement la roue à
ailettes, le moteur et l’intérieur du boîtier. NE JAMAIS PLONGER DANS L’EAU LES PIÈCES
MÉTALLIQUES OU ÉLECTRIQUES.
UTILISATION ET ENTRETIEN
SERVICE PARTS / PIÈCES DE RECHANGE
1
2
3
5
4
6
7
12
11
13
15
8
9
17
16
18
10
14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

NuTone 763NC Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues