IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTALLATION
AND
USER’S GUIDE
MICROBRITE™
COLOR AND WHITE LED LIGHT
FOR POOL AND SPA
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
ii
Technical Support
Phone: (800) 831-7133 - Fax: (800) 284-4151
www.pentair.com
Contents
IMPORTANT WARNING AND SAFETY INSTRUCTIONS................................. iii-iv
MicroBrite Color and White Pool Light Overview ..............................................1
Operating MicroBrite Lights Using a Wall Switch .............................................1
Using and External Transformer for Multiple 12 VAC MicroBrite .......................1
Maximum Wattage Using Multiple Color or White Lights
(with a 300 Watt Isolation Transformer) ............................................................1
Operating MicroBrite Color Lights Using a Wall Switch .....................................2
Powering on the MicroBrite Color Lights ...................................................2
Selecting a MicroBrite Light Color and Show Modes or Fixed Color
using a Wall Switch ....................................................................................2
Saving a Color Mode or Fixed Color ..........................................................3
MicroBrite White Light ................................................................................3
Power on the MicroBrite White Light...........................................................3
Selecting a MicroBrite White Light Brightness Level using a Wall Switch ...3
Selecting a MicroBrite Color Light Show Mode
MicroBrite Light Installation (1.5” Wall Fittings, New Pool - USA) ......................4
MicroBrite Light Installation (1.5” Wall Fittings, New Pool - Canada) .................5
WET CONDUIT INSTALLATION .....................................................................6
MicroBrite Light Compatible Wall Fittings Table ........................................ 6
DRY/SEALED CONDUIT INSTALLATION (USE PROVIDED KIT) ...................9
Fiber Optic Retrofit Applications .....................................................................10
MicroBrite Color and White Light Wiring Installation .......................................10
Replacing the MicroBrite Light Assembly (in an existing pool or spa) ..................11
Connecting MicroBrite Lights to an Automation Control System ..........................13
Troubleshooting ....................................................................................................13
Wiring MicroBrite Lights to 300 W Transformer.......................................................14
MicroBrite Color and White Lights Parts List ........................................................ 14
MicroBrite Color and White Lights Replacement Kits ........................................... 15
MicroBrite Color and White Light Dimensions ......................................................16
P/N 523371 Rev. F 1/2021
READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
iii
Most states and local codes regulate the construction, installation, and
operation of public pools and spas, and the construction of residential
pools and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult your local building and health
codes for more information.
SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS LIGHT
IS NOT INSTALLED AND USED CORRECTLY.
Before installing this product, read and follow all warning notices
and instructions in this Guide. Failure to follow warnings and
instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 for additional free copies of these instructions. Please refer to www.
pentair.com for more information related to this products.
IMPORTANT NOTICE - Attention Installer: This Installation and User’s
Guide (“Guide”) contains important information about the installation, operation
and safe use of this underwater pool and spa light. This Guide should be given
to the owner and/or operator of this equipment.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
This product must be installed by a licensed or certified electrician or a qualified
pool professional in accordance with the current National Electrical Code (NEC),
NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local
installation codes and ordinances must also be adhered to. Improper installation
will create an electrical hazard which could result in death or serious injury to pool
users, installers or others due to electrical shock, and may also cause damage to
power source. Always disconnect the power to the pool light at the circuit breaker
before installing or removing the light. Failure to do so could result in death or
serious injury.
For countries in compliance with International Electrotechnical
Commission (IEC) regulatory standards: The light fixture must
be installed by a licensed or certified electrician or a qualified pool service person, in
accordance with current IEC 364-7-702 and all applicable local codes and ordinance.
Improper installation will create an electrical hazard, which could result in death or serious
injury to pool user, installer or other due to electrical shock and may also cause damage
to the property.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST
READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE
USING THE POOL AND/OR SPA LIGHT.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
Before working or servicing pool lights, always disconnect
power to the pool and/or spa lights at the source circuit
breaker. Failure to do so could result in death or serious injury
to service person, pool users or others due to electric shock.
When installing and using this electrical equipment, basic
safety precautions should always be followed.
UNDERWATER POOL LIGHTS REQUIRE HIGH VOLTAGE WHICH
CAN SHOCK, BURN, OR CAUSE DEATH.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
iv
INSTALLERS AND INSPECTORS
THE MICROBRITE™ COLOR AND WHITE LED LIGHT AND WALL FITTING
FORM A COMPLETE NON-METALLIC LOW VOLTAGE LIGHTING SYSTEM.
THIS CONFIGURATION DOES NOT REQUIRE BONDING OR GROUNDING
WHEN POWERED BY A POOL RATED ISOLATION 100 WATT OR 300 WATT
TRANSFORMER (LISTED ON PAGE 1) AND INSTALLED IN COMPLIANCE WITH
THE CURRENT NATIONAL ELECTRIC CODE (NEC).
UNBONDED LIGHTING NEC PROVISIONS: When the UL listed non-metallic
MicroBrite Light low voltage lights are used. The current NEC provides an
exception to luminaire bonding and grounding in Article 680.6 and 680.23
POOL WATER BONDING NEC PROVISIONS : For Pool Water Bonding required by
NEC Article 680.26C, concrete pools are considered conductive (refer to 680.26
(b)(1) due to the porosity of concrete and the bonding of rebar. No additional
bonding is required.
POOL AND SPA FIXED LUMINAIRES: Follow these guidelines when installing
or replacing Pentair Water Pool and Spa fixed luminaires:
FOR LIGHT OPERATION, ONLY USE A SAFETY ISOLATION TRANSFORMER.
Note: Connect both wires to the corresponding circuit wires in the Junction
Box (black wire to power, and white wire to common) FIXED POOL AND SPA
LUMINAIRES SPECIFICATION: 12 VAC 50/60 Hz.
IMPORTANT NOTICE: THE MICROBRITE COLOR AND WHITE LED
LIGHT IS A NON-SERVICEABLE LIGHT. THE COMPLETE LIGHT
ASSEMBLY MUST BE REPLACED.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
CAUTION - DO NOT INSTALL MICROBRITE COLOR AND
WHITE LED LIGHTS WITH DIMMER SWITCHES. USE OF DIMMER
SWITCHES WILL RESULT IN PERMANENT DAMAGE TO THE
LIGHT.
MicroBrite™Color and White LED Lights are UL Approved
to be installed in a vertical position (facing up). Vertical light
installation must be installed minimum 4 inches below water
level.
Vertical Light installations are recommended only in
non-occupant areas of the pool (e.g. up-lighting a vanishing
edge overspill).
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
1
MicroBrite Color and White LED Light Overview
This manual describes how to install, replace and operate the 12 VAC MicroBrite Color
and White Light for pool and spa. The MicroBrite Color light provides brilliant vivid
multi-colors with spectacular effects for your pool. Choose one of the seven pre-
programmed color light shows or select one of the five fixed colors to create virtually
endless range of dramatic underwater lighting effects for a spectacular effect in your pool
and spa. The 12 VAC MicroBrite White Light features three different brightness levels. For
more information see page 2.
Operating MicroBrite Lights Using a Wall Switch
The MicroBrite light can be manually controlled using a standard wall-mount light switch.
Multiple MicroBrite lights can be connected via a junction box and a 12 VAC
isolation transformer to a single switch so that all lights can be switched on and off
together. For wiring diagram, see page 14.
Pentair Color LED lights can be controlled by Pentair Automation Systems
& Light Controllers. Contact your pool dealer for more information.
Using an External Safety Isolation Transformer for Multiple 12 VAC
MicroBrite Lights
When using multiple MicroBrite 12 VAC lights on a 100 Watt safety isolation transformer, it
is recommended that no more than six (6) MicroBrite color lights be used. For long cable
lengths for each light, It is recommended not to exceed 45.72 m (150 ft.) of total cable run
between the 12 VAC isolation transformer and the MicroBrite Color and/or White light.
Note: If a longer cable
run is necessary, it is
recommended that
separate 100 Watt safety
isolation transformers be
used for each light with
no more than 45.72 m
(150 ft.) of total cable run
between the transformer
and lights.
Maximum Wattage Using Multiple Color or White lights
(with a 300 Watt Isolation Transformer)
IMPORTANT! When using multiple 12 VAC Pentair pool and spa lights the total allowable
light wattage is 300 Watts maximum and should not exceed 80% of rated value. The
individual light wattage is as follows:
One MicroBrite Color Pool LED light is 12 Watts maximum
One MicroBrite White Pool LED light is 12 Watts maximum
One IntelliBrite Color pool LED light is 30 Watts maximum
One IntelliBrite Color spa LED light is 18 Watts maximum
J Box
12 Gauge
(minimum)
45.72 m
(150 ft.)
100 Watt
Transformer
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
2
Selecting a MicroBrite Color Light Show Mode or Fixed Color using a Wall
Switch
MicroBrite color lights are compatible with IntelliBrite® Color Light shows and can be
synchronized with IntelliBrite color lights.
First switch power on to the light. A white light will momentarily illuminate, followed by the
previously selected color. To select a color show mode (1-7) or fixed color
(8-12), turn the wall switch off/on a specific number of times. Each number (1-12) shown
below corresponds to the number of times to power-cycle the switch to activate a color
light show or fixed color.
1 SAm Mode: Cycles through white, magenta, blue and green colors
(emulates the Pentair SAm color changing light).
2 Party Mode: Rapid color changing building energy and excitement.
3 Romance Mode: Slow color transitions creating a mesmerizing and
calming effect.
4 Caribbean Mode: Transitions between a variety of blues and greens.
5 American Mode: Patriotic red, white and blue transition.
6 California Sunset Mode: Dramatic transitions of orange, red and
magenta tones.
7 Royal Mode: Richer, deeper color tones.
8 Blue: Fixed color.
9 Green: Fixed color.
10 Red: Fixed color.
11 White: Fixed color.
12 Magenta: Fixed color.
13 Hold: Save the current color effect during a color light show.
14 Recall: Activate the last saved color effect.
MicroBrite Color Lights can be controlled using a standard wall-mount light switch (or by
the Pentair Controller (sold separately), contact your dealer for more information. Multiple
MicroBrite color lights can be connected via a junction box and a 12 VAC transformer to a
single switch so that all lights can be switched on and off together. MicroBrite color lights
are controlled by cycling AC power to the 12 VAC transformer from a standard wall switch.
By turning the switch on and off a specific number of times, the light activates one of the
seven light show modes, fixed colors, or enables the “Hold” and “Recall” feature.
Powering on the MicroBrite Color Lights
When the MicroBrite color light is powered on, the previously selected color is displayed,
unless the HOLD or RECALL feature was previously enabled.
Note: If power to the light is off for more than five (5) seconds, the last color show mode or
fixed color that was saved will be displayed.
Example: To select California Sunset Mode; turn the switch on, then off and on six (6)
times. During the off/on switching process, no illumination will occur, then a white light will
momentarily illuminate.
WARNING During the off/on switching process, before the selected color is displayed, no illumination
will occur. This operating mode is normal during the switching process. During this period the pool and spa
will be dark and precautions should be taken to avoid unforeseen accidents. Failure to observe this
warning may result in serious injury or death to pool and spa users.
Number of times to cycle power (1-14)
Operating MicroBrite™ Color LED Light using a Wall Switch
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
3
Saving a Color Mode or Fixed Color
When power is switched off to the MicroBrite™ Color Lights, the last color show mode or
fixed color will be saved. The next time the light is powered on, the previously saved color
show mode or fixed color will be displayed. For example, while in “Party Mode” switch the
light off. Wait more than five (5) seconds, switch the light back on to resume Party Mode.
WARNING During the off/on switching process, before the selected color is displayed, no illumination
will occur. This operating mode is normal during the switching process. During this period the pool and spa
will be dark and precautions should be taken to avoid unforeseen accidents. Failure to observe this
warning may result in serious injury or death to pool and spa users.
Selecting a MicroBrite White Light Brightness Level using a Wall Switch
MicroBrite White lights allow you to choose from one of three brightness levels (100%,
75% and 50%). Whenever the MicroBrite white light is turned on, it starts at its highest
brightness level (100%). Unless it was previously set to the medium (75%) or low
brightness level (50%).
NOTE: MicroBrite Color models are not equipped with dimming functionality. Only
MicroBrite White lights have dimming functionality.
To select one of the three brightness levels (100%, 75% and 50%) first power on the
lights, then by rapidly cycling the light switch OFF and ON a specified number of times,
you can select the desired light brightness level.
Selecting the light’s brightness levels is as follows:
100% Brightness: Switching the lights OFF then rapidly back ON, will set
the lights to 100% brightness.
75% Brightness: Switch OFF-ON-OFF-ON and the lights will come on at
100% them dim to 75% after 1 second.
50% Brightness: Switch OFF-ON-OFF-ON-OFF-ON and the lights will
come on at 100%, dim to 75% after one second and then dim to 50% after
another second.
MicroBrite White Light
MicroBrite White Lights can be controlled using a standard wall-mount light switch.
Multiple MicroBrite white lights can be connected via a junction box and a 12 VAC trans-
former to a single switch so that all lights can be switched on and off together. MicroBrite
White lights are controlled by cycling AC power to the 12 VAC transformer from a stan-
dard wall switch. By turning the switch on and off a specific number of times, you can
choose from one of three brightness levels.
Powering on the MicroBrite White Light
Note: The MicroBrite White light ships from the factory in the 100% brightness mode.
When the MicroBrite White light is powered on, it defaults to the previously selected
brightness level. Note: If power to the light is off for more than five (5) seconds, the last
brightness level that was saved will be displayed.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
4
The following describes how to install the MicroBrite Light in a 1-1/2” wall fitting.
Note: MicroBrite lights are UL compliant for horizontal and vertical installation.
Be sure that the pool or spa meets the requirements of the current National Electrical
Code (N.E.C.) Article 680-22 and all local codes and ordinances. A licensed or
certified electrician must install the electrical system to meet or exceed those
requirements before the underwater light is installed. Some of the requirements of the
National Electrical Code which the pool’s electrical system must meet are as follows:
BEFORE STARTING: The following information describes the tasks that
must be completed by the electrician before the light wall fitting is installed.
See Figure 1.
The Junction Box and the low voltage transformer is located at least
4 (four) inches (10.16 cm) above ground level or eight (8) inches
(20.3 cm) above maximum water level, whichever is higher. The Junction Box
must be at least 48 inches (1.22 m) from the edge of the pool. See Figure 1.
To be certain that the pool or spa electrical system meets all applicable
requirements, the electrician should also consult the local building department.
MICROBRITE™ COLOR AND WHITE LED LIGHT
INSTALLATION IN 1.5” WALL FITTING (US)
Wall Fitting: 3.81 cm (1.5 in) PVC Pipe
For Gunite Only
NOTE: MicroBrite™Ligths are UL Approved to be installed in
a vertical position (facing up). Vertical light installation must
be installed minimum 4 inches below water level.
Vertical Light installations are recommended only in
non-occupant areas of the pool (e.g. up-lighting a
vanishing edge overspill).
Figure 1.
NOTE: SEE PAGE 16 FOR LIGHT DIMENSIONS.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
5
Be sure the electrical system of your pool conforms with the following requirements
of the Canadian Electrical Code (CE), and all local codes and ordinances. A licensed
or certified electrician must install the electrical system to meet or exceed those
requirements before the light and (fixture-housing) is installed. Some of the CE
requirements are listed below.
The junction/deck box must be sealed to the conduit to prevent water from
getting into the box, see Figure 2, below.
MICROBRITE™ COLOR AND WHITE LED LIGHT
INSTALLATION IN 1.5” WALL FITTING (CANADA)
The following information is for the Junction Box and pool deck location for Canada only.
Junction/Deck boxes shall be installed:
(a) above the normal water level of the pool;
(b) so that the top of the box is located at or above the finished level of the pool deck;
(c) in such a manner or location that the box will not be an obstacle; and
(d) in such a manner that any water on the deck will drain away from the box
(See diagram below).
Deck water drains
away from Junction/Deck Box
Approved Junction/Deck Box
Water level
below Junction/Deck Box
Approved Junction/Deck Box
elevated and protected
Diving Board or
other equipment
to protect
Junction/Deck Box
Top of Junction Box Flush
with Deck Junction/Desk Box elevated above
Deck and Protected
Figure 2, Canada.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
6
MicroBrite™ Color and White LED Light Installation
The MicroBrite light adaptor allows the mounting of the MicroBrite Light in the 1-1/2”
return fitting. Refer to the Compatible MicroBrite Light Wall Fittings table above.
Compatible Wall Fittings
Part No Description
86205100 Pentair
542429 Pentair
542402 Pentair
542414 Pentair
86205100 Pentair
542405 Pentair
542404 Pentair
Part No. Description
SP1022 Hayward
215-9170B WaterWay®
400-9150B WaterWay
215-9890B WaterWay
400-9170B WaterWay
CMP25550001060 CMP
CMP25522100000 CMP
CMP25550000000 CMP
WET CONDUIT INSTALLATION
1. To install a MicroBrite Light, route the MicroBrite light power cord light cable
through the 1.5” wall fitting to the location of the 12 VAC pool transformer or
junction box.
2. Wrap plumber’s thread sealant tape around the male threads on the white
threaded adaptor ring on the light.
3. Pull the MicroBrite power cord through the conduit so there is approximately
three to six inches of visible cord between the body of the MicroBrite light and
the wall fitting.
Note: MicroBrite lights are shipped from the factory with the white threaded adaptor
ring pre-installed onto the body of the light. The male threads on the white threaded
adaptor ring allow the light to be threaded into the female threads of most 1-1/2”
(1.5”) pool wall return fittings. To install the MicroBrite Light wall fitting into a
concrete/gunite pool:
Continue to Step 4 on next page.
Wrap threaded sealant
tape around the
adaptor
1-1/2” Standard
Wall Fitting
FOR FIBER OPTIC RETROFIT APPLICATIONS SEE PAGE 10.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
7
WET CONDUIT INSTALLATION (Continued)
4. With the MicroBrite light in your hands, roll the body of the light several turns
counter-clockwise, so that the cord of the MicroBrite light receives several
“pre-twists” in a counter-clockwise direction. Read Step 5 before continuing
with Step 6.
5. Dry/Sealed Conduit Installation (use provided kit), see page 9: If
code requires an O-Ring to be installed on the light for a dry conduit
installation, install the O-Ring as described on page 9, then continue with
Step 6 below.
6. Insert the MicroBrite light into the 1.5” wall fitting. By hand start the process of
threading the male threads on the MicroBrite’s white threaded adaptor ring into the
female threads of the wall fitting.
By hand, turn light body
counter-clockwise to
twist cord
Cord should be twisted
counter-clockwise
BEFORE INSTALLATION
By hand turn light clockwise.
Insert adaptor male thread
adaptor ring into female
thread of wall fitting
DURING INSTALLATION
Cord will un-twist
as light is turned
clockwise into fitting
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
8
WET CONDUIT INSTALLATION (Continued)
Continue to Light Wiring Installtion on page 10.
Installation Tool
1-1/2” Standard
Wall Fitting
Light Cable to Junction Box
7. Place Microbrite light installation tool (P/N 602158) over the front of the light
while turning the tool and light clockwise.
Note: If the light does not turn smoothly, pull the light slightly out and be sure
that it’s seated properly and the wall fitting is free of debris, then reinstall the
light.
8. Turn the light clockwise while threading it into the wall fitting to un-twist the
power cord.
9. Turn the light clockwise (approximately 5 turns) so that it is threaded tightly into
the wall fitting.
10. Note: Once the light is tightly installed remove the tool be sure the light
cannot be unscrewed using your fingers. The light should be secured in
place so that it can only be removed by using the light installation tool.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
9
DRY/SEALED CONDUIT INSTALLATION (USE PROVIDED KIT)
1. Note: The pool water level must be below the level of the 1.5” return fitting
where the MicroBrite will be installed.
2. Follow the Wet Conduit Installation Steps 1-10 as described on page 6, 7,
and 8. Skip Step 2. At Step 4, be sure to install the Optional O-Ring onto the
back of the MicroBrite light.
3. Stretch O-Ring over lens and seat in proper position.
4. Lubricate O-Ring with provided lubricant.
5. Pull Adapter Ring over O-Ring and twist adapter ring until tightly secured in
place.
6. Apply Clear Silicone (recommended pool industry silicone lubricant application)
around the threads of the adapter ring and wall fitting. Wipe away any excess
silicone lubricant after being assembled into the wall fitting.
7. Resume the installation process from Step 6 (see page 7).
1-1/2” Standard
Wall Fitting
Adaptor
Install O-Ring
behind light lens
Apply clear silicone
lubricant to male and
female threads
Light lens
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
10
MicroBrite™ Color and White LED Light Wiring Installation
To connect the MicroBrite Light to the transformer or junction box:
1. Route the MicroBrite light power cord light cable through the wall fitting to the
location of the 12 VAC pool transformer or junction box.
2. At the 12 VAC transformer or junction box, cut off any extra cord. Leave at
least 15.2 cm (6 in) of cord in the Junction Box or transformer to facilitate
the light installation wall fitting inspection. Cut off any extra cord.
See Figure 1 on page 4, for junction box installation for USA, see Figure 2
on page 5 for junction box installation in Canada.
3. Connect the two (2) conductors to the corresponding circuit wires in the Junction
Box. Secure the Junction Box cover.
Note: When using longer runs of cables or multiple lights per transformer,
it is recommended to use the 13 VAC or 14 VAC tap on the transformer.
4. Before operating the MicroBrite light, fill the pool with water until the light is
completely submerged.
Note: The MicroBrite color light should not be powered for more than 30
seconds if is not submerged in water.
5 Final check for proper MicroBrite light operation:
Switch on the main switch or circuit breaker to the 12 VAC transformer and the
switch that operates the MicroBrite light itself. The light should illuminate when
the 12 VAC power is applied. If not recheck the installation steps.
FIBER OPTIC RETROFIT APPLICATIONS
The MicroBrite™ Light may be suitable for many fiber optic retrofit applications.
IMPORTANT:
1. Before proceeding with the fiber optic retrofit installation, verify that the
MicroBrite light fits properly before removing the fiber optic system.
2. Refer to the MicroBrite light dimensional drawings on page 16.
3. Read all instructions to verify that all of the 1.5” fittings in the pool have
suitable dimensions to allow the MicroBrite light to fit properly.
4. Be sure the conduit that was previously utilized as housing for the fiber
optic cables meets all applicable codes and regulations that apply to
electrical conduit in swimming pool applications.
REPLACING THE MICROBRITE COLOR AND
WHITE LED LIGHT ASSEMBLY (IN AN EXISTING POOL OR SPA)
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
11
Verify that the pool and spa meets the requirements of the current National
Electrical Code and all local codes and ordinances. A licensed or certified
electrician must install the electrical system to meet or exceed those
requirements before the underwater light is installed. Some of the requirements
of the National Electrical Code which the pool’s electrical system must meet are
as follows:
The Junction Box and the low voltage transformer is located at least
4 (four) inches (10.16 cm) above ground level or eight (8) inches
(20.3 cm) above maximum water level, whichever is higher. The Junction Box
must be at least 48 inches (123 cm) from the edge of the pool. See Figure 1
on page 4.
The MicroBrite light wall fitting must be properly installed so that the top
edge of the lens of the MicroBrite light is at least 4 inches (10.16 cm) below
(not more than 48 inches (123.cm) below in Canada) the surface of the water
in the pool or spa. See Figure 2 on page 5.
To be certain that the pool or spa electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
Risk of Electrical Shock or Electrocution!
This underwater light must be installed by a licensed or certified
electrician or a qualified pool professional in accordance with
the current National Electrical Code (NEC), NFPA 70 or the
Canadian Electrical Code (CEC), CSA C22.1 and all applicable
local codes and ordinances. Improper installation will create an
electrical hazard which could result in death or serious injury to
pool users, installers or others due to electrical shock, and may
also cause damage to property.
Always disconnect the power to the pool light at the circuit
breaker before servicing the light. Failure to do so could result
in death or serious injury to service person, pool users or others
due to electrical shock.
IMPORTANT NOTICE: THE MICROBRITE COLOR AND WHITE LED
LIGHT IS A NON-SERVICEABLE LIGHT. THE COMPLETE LIGHT
ASSEMBLY MUST BE REPLACED.
REPLACING THE MICROBRITE COLOR AND
WHITE LED LIGHT ASSEMBLY (IN AN EXISTING POOL OR SPA)
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
12
The following removal and installation instructions describe how to remove and install the
MicroBrite light assembly.
1. Switch off electrical switch or circuit breaker at the source,
2. Remove Junction Box or Transformer cover. Disconnect the light wires and
attach a fish tape to the existing light power cord. This will assist in pulling the
replacement light power cord through the conduit back to the junction box.
3. Remove the MicroBrite light assembly from the pool or spa water: Using
the provided installation tool (P/N 602158), rotate the light assembly counter-
clockwise 1/8 of a turn to release the light from the wall fitting.
4. Slowly pull the light and attached power cord (with attached fish tape) out of
the wall fitting. Pull the light’s power cord and fish tape out of the wall fitting and
place the light on the deck.
5. Attach the new light power cord to the fish tape and carefully feed the fish tape
and cable to the junction box.
6. Install the light into the wall fitting: See page 6 and 9 for light installation
instructions.
7. Connect the two (2) conductors to the corresponding circuit wires in the
Junction Box: See page 10 for light wiring instructions.
8. Final check: See page 10 for final check instructions.
Failure to bring the pool or spa’s electrical system up to code requirements before
installing the underwater light will create an electrical hazard which could result in
death or serious injury to pool users, installers, or others due to electrical shock, and
may also cause damage to property.
IMPORTANT NOTICE: THE MICROBRITE LIGHT IS A
NON-SERVICEABLE LIGHT. THE COMPLETE LIGHT ASSEMBLY
MUST BE REPLACED.
IMPORTANT NOTICE: THE MICROBRITE COLOR AND WHITE LED
LIGHT IS A NON-SERVICEABLE LIGHT. THE COMPLETE
LIGHT ASSEMBLY MUST BE REPLACED.
1. Pentair automation Control System: Unlatch the enclosure door spring
latch, and open the door.
2. Discharge Electrostatic energy before removing the cover by first
touching the metal part of the enclosure.
3. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT PANEL.
Remove the panel from the enclosure.
4. Run the MicroBrite light power cord to the transformer which is attached to
the auxiliary relay in the load center.
5. Connect the 120 VAC side of a 12 VAC transformer to the LOAD SIDE of one
of the auxiliary (AUX) relays in the load center.
6. Connect the Neutral conductor from the 12 VAC transformer to the Neutral
bus bar in the load center.
7. After the connection has been completed, close the control panel and secure
it with the two (2) retaining screws.
8. Close the load center front door. Fasten the spring latch.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
13
IMPORTANT NOTICE: THE MICROBRITE COLOR AND WHITE LED
LIGHT IS A NON-SERVICEABLE LIGHT. THE COMPLETE
LIGHT ASSEMBLY MUST BE REPLACED.
1. Pentair automation Control System: Unlatch the enclosure door spring
latch, and open the door.
2. Discharge Electrostatic energy before removing the cover by first
touching the metal part of the enclosure.
3. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT PANEL.
Remove the panel from the enclosure.
4. Run the MicroBrite light power cord to the transformer which is attached to
the auxiliary relay in the load center.
5. Connect the 120 VAC side of a 12 VAC transformer to the LOAD SIDE of one
of the auxiliary (AUX) relays in the load center.
6. Connect the Neutral conductor from the 12 VAC transformer to the Neutral
bus bar in the load center.
7. After the connection has been completed, close the control panel and secure
it with the two (2) retaining screws.
8. Close the load center front door. Fasten the spring latch.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect AC power to automation control system load center at the
circuit breaker before servicing, or removing the HIGH VOLTAGE FRONT PANEL.
Failure to do so could result in death or serious injury to installer, service person,
pool users, or others due to electrical shock.
CONNECTING MICROBRITE COLOR AND WHITE LED LIGHTS
TO AN AUTOMATION CONTROL SYSTEM
Troubleshooting (MicroBrite Lights)
Light does not function properly: Be sure that there is 12 VAC power applied to
the light.
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
14
Note: Up to six (6) MicroBrite 12 VAC lights
can be connected to a 100 Watt transformer.
AUX 1
LINE 1
LOAD 1
Neutral
Ground
GROUND
Black
White
JUNCTION
BOX
Five MicroBrite 12 VAC
Lights require a 100 Watt
transformer.
120V/12V
Step Down
Transformer
(
100W or 300W
)
Black
White
CIRCUIT BREAKER
LOAD 1
LINE 1
NEUTRAL
AUTOMATION CONTROL SYSTEM
MAIN CIRCUIT BOARD
AUXILIARY RELAYS
AUX 1
(see page 1 for
transformer
load maximum)
Note: Qty 6 to 7 MicroBrite 12 VAC
Lights require a 300 Watt
transformer.
Automation Control System Load Center Wiring Diagram
MicroBrite Light with Wall Switch Wiring Diagram
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
15
MicroBrite Color and White LED Lights Parts List
Part No. Description
620424 MicroBrite Color Light 12 VAC 50’ cord
620425 MicroBrite Color Light 12 VAC 100’ cord
620426 MicroBrite Color Light 12 VAC 150’ cord
620428 MicroBrite White Light 12 VAC 50’ cord
620429 MicroBrite White Light 12 VAC 100’ cord
602156 MicroBrite Warm White Light 12 VAC 50’ cord
620457 MicroBrite Warm White Light 12 VAC 100’ cord
602155 Microbrite Warm White Light 12 VAC 150’ cord
620430 MicroBrite White Light 12 VAC 150’ cord
602157 MicroBrite Turtle Edition Light 12 VAC 150’ cord
MicroBrite Color and White LED Light Bundles
620427 Two MicroBrite Color Light Combo 100’ w/300W transformer
620431 Two MicroBrite White Light Combo 100’ w/300W transformer
Part No. Description
MicroBrite Color and White LED Lights Parts List
Part No. Description
620460 MicroBrite Light Adaptor (replacement)
620459 Installation Tool (replacement - original)
602158Z Installation Tool (replacement)
620463 Conduit Seal O-Ring (replacement)
MicroBrite Color and White LED Lights Replacement Kits
MicroBrite Light Adaptor
O-Ring
Installation Tool
Original Installation
Tool (P/N 620459)
MicroBrite Color and White Light Installation and User’s Guide MicroBrite Color and White Light Installation and User’s Guide
16
MicroBrite Color and White LED Light Dimensions
THREADED ADAPTER
1.83” (46 mm)
3.0” (76 mm)
THREADED ADAPTER
INSTALLATION TOOL
1.82” (46.2 mm)
0.5” (12 mm)
SECTION VIEW
THREADED
ADAPTER -
FITS 1-1/2”
NPT & NPS
THREADS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Pentair Pool MICROBRITE Mode d'emploi

Catégorie
Accessoires de piscine hors terre
Taper
Mode d'emploi