9ERIKSON OUTDOOR FAUX CONCRETE FIRE PIT TABLE
SAFETY INFORMATION
Never use tools. If the valve will not turn by hand, do not try to repair it. Call a
certified gas technician. The use of force or any self-attempted repair may result in
a fire or explosion.
When connecting your gas cylinder:
1. This fire table comes equipped with
standard LP gas hose and regulator
including the appliance side connection
for a CGA No 791 Cylinder Connection
Device. The LP gas hose and regulator
supplied with this fire table must be used.
Only a hose and regulator specified
by manufacturer can be used for
replacement.
a. The CGA No 791 connection
incorporates a magnetic flow limiting
device that acts to limit the flow of gas if
a leak is detected between the regulator
and the burner valve.
b. If the burner valve is open prior to
the LP gas cylinder service valve being
opened, the connection will interpret this
free flow of gas to be a leak.
c. The connection safety feature will
reduce gas flow from the regulator to the
appliance to a minimal level.
d. Be sure that the burner control valve
is closed prior to opening the LP gas
cylinder service valve to ensure that the
connection flow limiting device is not
triggered mistakenly.
e. The pressure regulating valve has a flow
restriction device. If the propane hose is
badly damaged, the flow-restriction
device will be activated and there will be
less gas going out. If the connection flow
limiting device is triggered mistakenly,
close the LP gas cylinder service valve
and the burner valve, wait 10 seconds to
allow the device to reset, open the
cylinder service valve, then open the
burner valve and light the fire table as per
lighting instructions.
2. Be sure to protect the hose from any
hot surfaces. Serious danger may result if
the hose contacts any hot surface.
3. Regular maintenance of the hose and
regulator:
a. Inspect the hose before each use of the
fire table. If the hose shows signs of
cracks, abrasions, cuts or damage of any
kind, do not operate the appliance. Fix or
replace the hose as required before using
the appliance. For assistance with repair
or replacement of the hose, call the
service centre at 1-888-670-6684. Use
only replacement parts from the
manufacturer.
b. Inspect the seal inside the CGA No 791
service valve on the LP gas cylinder when
replacing the cylinder or at least once per
year. If there is any indication of damage,
have the seal replaced by a certified gas
dealer before operating the appliance.
4. Do not use tools to tighten the CGA
No 791 connection nut onto the LP gas
HOSE AND REGULATOR ASSEMBLY AND REPLACEMENT
Before connecting, make sure there is no debris in the propane cylinder head,
regulator head, or burner ports. Connect the regulator valve and tighten securely
by hand.The gas supply must be turned off at the propane gas supply cylinder
when this appliance is not in use. DO NOT obstruct the flow of combustion or
ventilation air to the burner.