Rockwell Automation Allen-Bradley Micro800 Wiring Diagrams

Taper
Wiring Diagrams
Wiring Diagrams
Micro800™ Non-isolated Unipolar Analog
Output Plug-in Module
Catalog Number 2080-OF2
http://literature.rockwellautomation.com
FR
Cette publication est disponible en français sous forme électronique (fichier PDF).
Pour la télécharger, rendez-vous sur la page Internet indiquée ci-dessus.
IT
Questa pubblicazione è disponibile in Italiano in formato PDF. Per scaricarla
collegarsi al sito Web indicato sopra.
DE
Diese Publikation ist als PDF auf Deutsch verfügbar. Gehen Sie auf die oben
genannte Web-Adresse, um nach der Publikation zu suchen und sie
herunterzuladen.
ES
Esta publicación está disponible en español como PDF. Diríjase a la dirección web
indicada arriba para buscar y descarga esta publicación.
PT
Esta publicação está disponível em portugués como PDF. Vá ao endereço web que
aparece acima para encontrar e fazer download da publicação.
ZH
ZC
KO
2 Micro800™ Non-isolated Unipolar Analog Output Plug-in Module
Publication
2080-WD004A-EN-P - May 2011
Environment and Enclosure
Preventing Electrostatic Discharge
ATTENTION
This equipment is intended for use in a Pollution Degree 2 industrial
environment, in overvoltage Category II applications (as defined in IEC
60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment
is considered Group 1, Class A industrial equipment according to IEC/CISPR
11. Without appropriate precautions, there may be difficulties with
electromagnetic compatibility in residential and other environments due to
conducted and radiated disturbances.
This equipment is supplied as open-type equipment. It must be mounted
within an enclosure that is suitably designed for those specific environmental
conditions that will be present and appropriately designed to prevent personal
injury resulting from accessibility to live parts. The enclosure must have
suitable flame-retardant properties to prevent or minimize the spread of flame,
complying with a flame spread rating of 5V A, V2, V1, V0 (or equivalent) if
non-metallic. The interior of the enclosure must be accessible only by the use
of a tool. Subsequent sections of this publication may contain additional
information regarding specific enclosure type ratings that are required to
comply with certain product safety certifications.
In addition to this publication, see:
Industrial Automation Wiring and Grounding Guidelines, Rockwell
Automation publication 1770-4.1
, for additional installation
requirements.
NEMA Standard 250 and IEC 60529, as applicable, for explanations of
the degrees of protection provided by different types of enclosure.
ATTENTION
This equipment is sensitive to electrostatic discharge, which can cause
internal damage and affect normal operation. Follow these guidelines when
you handle this equipment:
Touch a grounded object to discharge potential static.
Wear an approved grounding wriststrap.
Do not touch connectors or pins on component boards.
Do not touch circuit components inside the equipment.
Use a static-safe workstation, if available.
Store the equipment in appropriate static-safe packaging when not in
use.
Micro800™ Non-isolated Unipolar Analog Output Plug-in Module 3
Publication
2080-WD004A-EN-P - May 2011
North American Hazardous Location Approval
The following modules are North American Hazardous Location approved:
2080-OF2
The following information applies
when operating this equipment in
hazardous locations:
Informations sur l’utilisation de cet
équipement en environnements dangereux:
Products marked "CL I, DIV 2, GP A, B, C, D" are
suitable for use in Class I Division 2 Groups A,
B, C, D, Hazardous Locations and nonhazardous
locations only. Each product is supplied with
markings on the rating nameplate indicating the
hazardous location temperature code. When
combining products within a system, the most
adverse temperature code (lowest "T" number)
may be used to help determine the overall
temperature code of the system. Combinations
of equipment in your system are subject to
investigation by the local Authority Having
Jurisdiction at the time of installation.
Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu'à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages
sur sa plaque d'identification qui indiquent le code de
température pour les environnements dangereux.
Lorsque plusieurs produits sont combinés dans un
système, le code de température le plus défavorable
(code de température le plus faible) peut être utilisé
pour déterminer le code de température global du
système. Les combinaisons d'équipements dans le
système sont sujettes à inspection par les autorités
locales qualifiées au moment de l'installation.
WARNING
EXPLOSION HAZARD
Do not disconnect
equipment unless power
has been removed or the
area is known to be
nonhazardous.
Do not disconnect
connections to this
equipment unless power
has been removed or the
area is known to be
nonhazardous. Secure any
external connections that
mate to this equipment by
using screws, sliding
latches, threaded
connectors, or other means
provided with this product.
Substitution of any
component may impair
suitability for Class I,
Division 2.
If this product contains
batteries, they must only be
changed in an area known
to be nonhazardous.
AVERTISSEMENT
RISQUE D’EXPLOSION
Couper le courant ou s'assurer
que l'environnement est
classé non dangereux avant de
débrancher l'équipement.
Couper le courant ou s'assurer
que l'environnement est
classé non dangereux avant de
débrancher les connecteurs.
Fixer tous les connecteurs
externes reliés à cet
équipement à l'aide de vis,
loquets coulissants,
connecteurs filetés ou autres
moyens fournis avec ce
produit.
La substitution de tout
composant peut rendre cet
équipement inadapté à une
utilisation en environnement
de Classe I, Division 2.
S'assurer que l'environnement
est classé non dangereux
avant de changer les piles.
4 Micro800™ Non-isolated Unipolar Analog Output Plug-in Module
Publication
2080-WD004A-EN-P - May 2011
Parts List
Your package contains one Micro800 Non-isolated Unipolar Analog Output
Plug-in Module and these pinout guide wiring instructions.
You can choose to wire the plug-in before inserting it onto the controller, or
wire it once the module is secured in place.
ATTENTION
This equipment is considered Group 1, Class A industrial equipment
according to IEC/CISPR 11. Without appropriate precautions, there may be
difficulties with electromagnetic compatibility in residential and other
environments due to conducted and radiated disturbance.
Be careful when stripping wires. Wire fragments that fall into the controller
could cause damage. Once wiring is complete, make sure the controller is
free of all metal fragments before removing the protective debris strip.
Do not wire more than 2 conductors on any single terminal.
If you insert or remove the plug-in module while power is on, an electrical
arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous
before proceeding.
Cable length should be less than 10 meters.
Do not insert or remove the plug-in module while power is applied,
otherwise, permanent damage to equipment may occur.
45013
Micro800™ Non-isolated Unipolar Analog Output Plug-in Module 5
Publication
2080-WD004A-EN-P - May 2011
Wire the Module
Follow the pinout diagram to wire your plug-in module.
8-Pin Female Terminal Block
Insert Module into Controller
Follow the instructions to insert and secure the plug-in module to the
controller.
1. Position the plug-in module with the terminal block facing the front
of the controller as shown.
2. Snap the module into the module bay.
3. Using a screwdriver, tighten the 10…12 mm (0.39…0.47 in.) M3 self
tapping screw to torque specifications.
1 2 3 4
1 2 3 4
B
A
Back
Front
40514
(View into terminal block)
Pin A1 COM Pin B1 VO-0
Pin A2 COM Pin B2 CO-0
Pin A3 COM Pin B3 VO-1
Pin A4 COM Pin B4 CO-1
44015
6 Micro800™ Non-isolated Unipolar Analog Output Plug-in Module
Publication
2080-WD004A-EN-P - May 2011
Specifications
General and Environmental Specifications
Attribute Value
Mounting torque 0.2 Nm (1.48 lb-in)
Terminal screw torque 0.22…0.25 Nm (1.95…2.21 lb-in)
(using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Wire size
0.14…1.5 mm
2
(26…16 AWG) solid copper wire or
0.14…1.0 mm
2
(26…17 AWG) stranded copper wire
rated @ 90 °C (194 °F ) insulation max
Voltage resistive load, min 1 kΩ
Current resistive load, max 500 Ω
Output voltage range 0…10V
Output current range 0…20 mA
Power consumption <60 mA @ 24V
Temperature, operating IEC60068-2-1 (Test Ad, Operating Cold),
IEC60068-2-2, (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20...65 °C (-4…149 °F)
Temperature, surrounding air, max. 65 °C (149 °F)
Temperature, non-operating IEC60068-2-1 (Test Ad, Operating Cold),
IEC60068-2-2, (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-40...85 °C (-40…185 °F)
North American temp code T4
Micro800™ Non-isolated Unipolar Analog Output Plug-in Module 7
Publication
2080-WD004A-EN-P - May 2011
Certifications
Certification (when
product is marked)
(1)
Value
c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada.
See UL File E322657.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations,
certified for U.S. and Canada. See UL File E334470.
CE European Union 2004/108/EC EMC Directive, compliant with:
EN 61326-1; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
European Union 2006/95/EC LVD, compliant with:
EN 61131-2; Programmable Controllers (Clause 11)
C-Tick Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
(1)
See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates,
and other certification details.
Rockwell Automation Support
Rockwell Automation provides technical information on the Web to assist you in using
its products. At http://support.rockwellautomation.com
, you can find technical
manuals, a knowledge base of FAQs, technical and application notes, sample code and
links to software service packs, and a MySupport feature that you can customize to
make the best use of these tools.
For an additional level of technical phone support for installation, configuration, and
troubleshooting, we offer TechConnect support programs. For more information,
contact your local distributor or Rockwell Automation representative, or visit
http://support.rockwellautomation.com
.
Installation Assistance
If you experience a problem within the first 24 hours of installation, please review the
information that's contained in this manual. You can also contact a special Customer
Support number for initial help in getting your product up and running.
New Product Satisfaction Return
Rockwell Automation tests all of its products to ensure that they are fully operational
when shipped from the manufacturing facility. However, if your product is not
functioning and needs to be returned, follow these procedures.
Allen-Bradley, Rockwell Automation, Micro800 and TechConnect are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
United States 1.440.646.3434
Monday – Friday, 8 a.m. – 5 p.m. EST
Outside United States Please contact your local Rockwell Automation representative for any
technical support issues.
United States Contact your distributor. You must provide a Customer Support case number
(see phone number above to obtain one) to your distributor in order to
complete the return process.
Outside United States Please contact your local Rockwell Automation representative for the return
procedure.
Publication 2080-WD004A-EN-P - May 2011 PN 953203-24(01)
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Printed in Singapore.