Ashley Hearth Products AC1100 Manuel utilisateur

Catégorie
Poêle à bois
Taper
Manuel utilisateur
SAFETY NOTICE:
If this heater is not properly installed, a house re
may result. For your safety, follow the installation
instructions. Never use make-shift compromises
during the installation of this heater. Contact local
building or re ofcials about permits, restrictions and
installation requirements in your area.
CAUTION!
Please read this entire manual before you install
or use your new room heater. Failure to follow
instructions may result in property damage, bodily
injury, or even death.
Improper Installation Could Void Your Warranty!
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU
TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
French version is available for download from the U.S. Stove website: http://www.usstove.com/
La version française est disponible pour téléchargement à partir du site U.S. Stove: http://www.usstove.com/
Approved for installation in the U.S.A.
CONFORMS TO UL 1482, AND CERTIFIED TO ULC-S627
ALSO SUITABLE FOR MOBILE HOME INSTALLATION.
852263F-2502G
Owner’s Manual MODEL: AC1100
U.S. Stove
227 Industrial Park Road
South Pittsburg, TN 37380
(800) 750-2723 • www.usstove.com
U.S. Environmental Protection Agency
Certied to comply with 2015 particulate emissions standards.
-2-
CAUTIONS:
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS.
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS,
RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.
Combustible: Wood
Colors: Metallic Black
Flue Pipe Diameter: 6” (153cm)
Flue Pipe Type: (Standard Single Wall or Double Wall): Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height: 12’ (3.7m)
Maximum Log Length: 18” (457mm)
Electrical 115V, 60Hz, 1.5A
Dimensions
Overall: Depth x Width x Height: 24” x 29” x 28” (609.6mm x 736.6mm x 711.2mm)
Combustion Chamber:
Width x Depth:
18.3” x 11.5” (465mm x 293mm)
Volume:
Cubic Feet:
1.4 cubic feet
Door Opening: Width x Height: 17” x 8.6” (4.32mm x 2.18mm)
Pyroceramic Glass Door: (Viewing) Width x Height: 16.5” x 10” (419mm x 254mm)
Weight (lbs): 450 lbs
Specications
You’ve purchased a heater from North America’s oldest manufacturer of wood burning products.
By heating with wood you’re helping to CONSERVE ENERGY!
Wood is our only Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least
one tree each year. Future generations will thank you.
This manual describes the installation and operation of the Ashley, AC1100 wood heater. This heater meets the
2015 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015.
Under specic test conditions this heater has been shown to deliver heat at rates ranging from 10,925 to 24,900
Btu/hr.
Note: The BTU ratings mentioned above are based on the EPA test protocol burning dimensional Douglas Fir
lumber. Our advertised BTU’s are based on the rst hour of operation at high burn rate burning cordwood.
-3-
UNPACK AND INSPECT
Remove the packing from the appliance and inspect for any damage. Ensure that the bricks are positioned
correctly and not broken (see illustration for proper brick arrangement). Make sure that the bafe board, above
the air tubes, is in place and undamaged. DO NOT remove the bafe board.
TOOLS AND MATERIALS NEEDED FOR INSTALLATION
A 7/16” socket wrench
A 5/16” socket (Best if using a power drill and a socket bit)
A pair of pliers or channel-locks
A power drill with an 1/8” drill bit to install sheet metal screws into connector pipe.
Sheet metal screws
A non-combustible oor protector as specied in this manual
All chimney and chimney connector components required for your particular venting installation.
PRE-ASSEMBLY
Brick Conguration
ASSEMBLY
ASSEMBLY INSTRUCTIONS
Read and follow the directions in this manual to ensure proper assembly, installation and operation of your new
wood heater.
Caution! The appliance is very heavy.
The assistance from a second person is strongly suggested. Please use proper lifting technic when positioning the
appliance for assembly and installation. Several methods may be used to attach the legs and pedestal to the
appliance. The safest method is to roll the appliance on its back. When using this method, you should rst remove
the rebrick from the unit so as to reduce weight and possible breakage. It will be required to raise the bottom
of the unit up to attach two of the legs. It is recommended that you use cardboard or other means of padding
to protect the nish on your new stove.
FREESTANDING LEG ASSEMBLY
1. Unpack the stove and ensure all components are present:
2. Position the unit for assembly.
3. Make sure that the re brick is in place and undamaged. DO NOT remove the re brick.
-4-
INSTALLATION
POSITIONING THE STOVE
It is very important to position the stove as close as possible to the chimney, and in an area that will favor the
most efcient heat distribution possible throughout the house. The stove must therefore be installed in the room
where the most time is spent, and in the most spacious room possible. Recall that stoves produce radiating
heat, the heat we feel when we are close to a stove. A stove also functions by convection, that is through
the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air
distribution from the stove may be facilitated by the use of a fan or blower.
FREE STANDING STOVE INSTALLATION
A stove must never be installed in a hallway or near a staircase, since it may block the way in case of re or fail
to respect required clearances. It is of the utmost importance that the clearances to combustible materials be
strictly adhered to during installation of the stove. Refer to the table and diagrams below for minimum required
clearances.
Do not place any combustible material within 4’ (1.2m) of the front of the unit.
The clearance between the ue pipe and a wall are valid only for vertical walls and for vertical ue pipe.
The chimney connector must not pass through an attic or roof space, closet or similar concealed space, a
oor, or a ceiling.
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Ceiling / Plafond
Floor Protector / Protection de Plancher
K
H
L
J
M M
C
B
A
E
E
D
D
F
G
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Ceiling / Plafond
Floor Protector / Protection de Plancher
K
H
L
J
M M
C
B
A
E
E
D
D
F
G
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Ceiling / Plafond
Floor Protector / Protection de Plancher
K
H
L
J
M M
C
B
A
E
E
D
D
F
G
Dimension Inch mm
A Backwall to Stove 11 280
B Sidewall to Stove 7 178
C Sidewall to Flue 17.3 440
D Wall to Stove (Angled
Installation)
3 77
E Wall to Flue (Angled Installation) 14.4 366
F Ceiling Height 84 2134
G Backwall to Flue 14.8 376
SAFETY NOTICE
If this stove is not properly installed, a house re may result. To reduce the risk of re, follow the installation
instructions.
Consult your municipal building department or re ofcials about permits, restrictions and installations
requirements in your area.
Use smoke detectors in the room where your stove is installed.
Smoke expelled from the unit, by either paint curing, opening the fuel loading door, or a negative pressure
inside the home, could trigger the smoke detectors. Mount smoke detectors at least 10’ from stove
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter uid, or similar liquids to start or
“freshen up” a re in this heater. Keep all such liquids well away from the heater while it is in use.
In the event of a chimney re, push the air control full closed to deprive the re of oxygen. Call the re
department.
A source of fresh air into the room or space heated shall be provided when required.
Room heater, solid fuel type, also for use in mobile homes.
For Canadian installations, where passage
through a wall, or partition of combustible
construction is desired, the installation must
conform to CAN/CSA-B365.
A ue pipe crossing a combustible wall
must have a minimum clearance of 18”
(457.2mm).
To reduce ue clearances from
combustible materials, contact your local
safety department.
-5-
FLOOR PROTECTOR
The stove must be placed on solid concrete, solid masonry, or when installed on a combustible oor, on a oor
protector. The oor protector is required to provide heat, live ember, and ash protection and must be of a non-
combustible, continuous solid surface to protect against inltration of live embers and ash. The stove must be
placed on solid concrete, solid masonry, or when installed on a combustible oor, on a Type 2 oor protector
listed to standard UL 1618 with a minimum R value of 1.03 and a minimum thickness of 1/2” or equivalent.
Dimension Inch mm
H* Front 16 407
J Flue rear 2 51
K** Left 6 204
L** Right 6 204
M Flue Side 2 51
* Canadian installations require 18” (457mm)
** Canadian installations require 8” (203mm)
SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - Do not install in a sleeping room
CAUTION! - The structural integrity of the
mobile home oor, wall, and ceiling/roof must be
maintained.
In addition to the previously detailed installation
requirements, mobile home installations must meet the
following requirements:
The heater must be permanently attached to the
oor.
1. There are two holes in the pedestal base, use
3/8” bolts through the oor.
2. To attach the leg model use two 3/8-16 UNC
bolts through the oor.
The heater must be electrically grounded to the
steel chassis of the mobile home with 8 GA copper
wire using a serrated or star washer to penetrate
paint or protective coating to ensure grounding.
When moving your mobile home, all exterior venting
must be removed while the mobile home is being
relocated. After relocation, all venting must be
reinstalled and securely fastened.
Outside Air is mandatory for mobile home installation.
See your dealer for purchasing.
Check with your local building ofcials as other
codes may apply.
Mobile Home Attachment
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Side wall / Paroi Latérale
Side wall / Paroi Latérale
Back wall / Arrière Mur
Ceiling / Plafond
Floor Protector / Protection de Plancher
K
H
L
J
M M
C
B
A
E
E
D
D
F
G
-6-
COMBUSTION AIR ASSEMBLY INSTRUCTIONS
This appliance requires a source of combustion air. If your home is of tight construction or has negative pressure
problems, you will need an outside source of air. Below is a list of possible indicators that a source of outside
combustion air may be required.
1. Your stove does not draw steadily, smoke rollout occurs, wood burns poorly, or back-drafts occur whether or
not there is combustion present.
2. Existing fuel-red equipment in the house, such as replaces or other heating appliances, smell, do not
operate properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is combustion
present.
3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
4. The house is equipped with a well-sealed vapor barrier and tight tting windows and/or has any powered
devices that exhaust house air.
5. There is excessive condensation on windows in the winter.
6. A ventilation system is installed in the house.
If an outside air intake is required. You may purchase a standard 4” Dryer Vent kit from your local hardware
supply store. If using a Dryer venting kit, the outlet cover must be of a design that DOES NOT close by means of a
ap or trap door. You must purchase a style that allows a continuous in-ow of air and that has a rodent screen.
DRYER VENTING KIT” INSTALLATION
Follow the manufacturer’s installation instructions for attaching the dryer vent kit to the home. Then attach it to
the appliance.
CHIMNEY
Your wood stove may be hooked up with a factory built or masonry chimney, matching the diameter of the stove
exhaust. If you are using a factory built chimney, it must comply with UL 103 or CSA-B365 standard; therefore it must
be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer’s specications.
Take into account the chimney’s location to insure it is not too close to neighbors or in a valley which may cause
unhealthy or nuisance conditions.
If you are using a masonry chimney, it is important that it be built in compliance with the specications of the
National Building Code. It must be lined with re clay bricks, metal or clay tiles sealed together with re cement.
(Round ues are the most efcient).
The interior diameter of the chimney ue must be identical to the stove smoke exhaust. A ue which is too small
may cause draft problems, while a large ue favors rapid cooling of the gas, and hence the build-up of creosote
and the risk of chimney res. Note that it is the chimney and not the stove which creates the draft effect; your
stove’s performance is directly dependent on an adequate draft from your chimney.
Do not connect this unit to a chimney ue serving another appliance.
The following recommendations may be useful for the installation of your chimney:
It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact.
The exterior portion should be double or triple wall pipe to ensure proper draft.
The chimney must exceed any part of the building or other obstruction within a 10’ (3.04m) distance by a
height of 2’ (0.6m).
Installation of an interior chimney is always preferable to an exterior chimney. The interior chimney will
be hotter than an exterior chimney that is being cooled by the ambient air outside the house. Therefore
the gas which circulates will cool
slower, thus reducing the build-
up of creosote and the risk of
chimney res.
The draft caused by the
tendency for hot air to rise will
be increased with an interior
chimney.
Using a re screen at the
extremity of the chimney requires
regular inspection in order to
insure that it is not obstructed
thus blocking the draft, and it
should be cleaned when used
regularly.
Ventilation
-7-
MASONRY CHIMNEY
Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA)
by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration
and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the
stove through a combustible wall to a masonry chimney, special methods are needed as explained in the “5.5
Combustible Wall Chimney Connector Pass-Throughs” Section.
-8-
COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS
Method A. 12” (304.8 mm) Clearance to Combustible Wall
Member: Using a minimum thickness 3.5” (89 mm) brick and a
5/8” (15.9 mm) minimum wall thickness clay liner, construct a
wall pass-through. The clay liner must conform to ASTM C315
(Standard Specication for Clay Fire Linings) or its equivalent.
Keep a minimum of 12” (304.8 mm) of brick masonry between the
clay liner and wall combustibles. The clay liner shall run from the
brick masonry outer surface to the inner surface of the chimney
ue liner but not past the inner surface. Firmly grout or cement
the clay liner in place to the chimney ue liner.
Method B. 9” (228.6 mm) Clearance to Combustible Wall
Member: Using a 6” (152.4 mm) inside diameter, listed, factory-
built Solid-Pak chimney section with insulation of 1” (25.4 mm) or
more, build a wall pass-through with a minimum 9” (228.6 mm) air
space between the outer wall of the chimney length and wall
combustibles. Use sheet metal supports fastened securely to wall
surfaces on all sides, to maintain the 9” (228.6 mm) air space.
When fastening supports to chimney length, do not penetrate
the chimney liner (the inside wall of the Solid-Pak chimney). The
inner end of the Solid-Pak chimney section shall be ush with the
inside of the masonry chimney ue, and sealed with a non-water
soluble refractory cement. Use this cement to also seal to the
brick masonry penetration.
Method C. 6” (152.4 mm) Clearance to Combustible Wall
Member: Starting with a minimum 24 gauge (.024” [.61 mm]) 6”
(152.4 mm) metal chimney connector, and a minimum 24 gauge
ventilated wall thimble which has two air channels of 1” (25.4 mm)
each, construct a wall pass-through. There shall be a minimum
6” (152.4) mm separation area containing berglass insulation,
from the outer surface of the wall thimble to wall combustibles.
Support the wall thimble, and cover its opening with a 24-gauge
minimum sheet metal support. Maintain the 6” (152.4 mm) space.
There should also be a support sized to t and hold the metal
chimney connector. See that the supports are fastened securely
to wall surfaces on all sides. Make sure fasteners used to secure
the metal chimney connector do not penetrate chimney ue
liner.
Method D. 2” (50.8 mm) Clearance to Combustible Wall
Member: Start with a solid-pak listed factory built chimney section
at least 12” (304 mm) long, with insulation of 1” (25.4 mm) or more,
and an inside diameter of 8” (2 inches [51 mm] larger than the
6” [152.4 mm] chimney connector). Use this as a pass-through for
a minimum 24-gauge single wall steel chimney connector. Keep
solid-pak section concentric with and spaced 1” (25.4 mm) off
the chimney connector by way of sheet metal support plates at
both ends of chimney section. Cover opening with and support
chimney section on both sides with 24 gauge minimum sheet
metal supports. See that the supports are fastened securely to
wall surfaces on all sides. Make sure fasteners used to secure
chimney ue do not penetrate ue liner.
NOTES:
Connectors to a masonry chimney, excepting method B, shall
extend in one continuous section through the wall pass-
through system and the chimney wall, to but not past the
inner ue liner face.
A chimney connector shall not pass through an attic or roof
space, closet or similar concealed space, or a oor, or
ceiling.
-9-
CHIMNEY CONNECTOR (STOVE PIPE)
Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case,
we recommend you contact your dealer in order to insure there will be no problem with the draft.
The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021” or 0.53 mm. It is
strictly forbidden to use galvanized steel.
Your stove pipe should be assembled in such a way that the male section (crimped end) of the pipe faces
down. Attach each of the sections to one another with three equidistant metal screws. Seal the joints with furnace
cement.
The pipe must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot,
with the upper end of the section toward the chimney. Any installation with a horizontal run of stove pipe must
conform to NFPA 211. You may contact NFPA (National Fire Protection Association) and request the latest edition
of the NFPA Standard 211.
To insure a good draft, the total length of the stove pipe should never exceed 8’ to 10’ (2.4m to 3.04 m). (Except
for cases of vertical installation, cathedral-roof style where the smoke exhaust system can be much longer and
connected without problem to the chimney at the ceiling of the room).
There should never be more than two 90 degrees elbows in the smoke exhaust system.
Installation of a “barometric draft stabilizer” (replace register) on a smoke exhaust system is prohibited.
Furthermore, installation of a draft damper is not recommended. With a controlled combustion wood stoves the
draft is regulated upon intake of the combustion air in the stove and not at the exhaust.
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too
much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpufng into
the room and ‘plugging’ of the chimney. Inadequate draft will cause the appliance to leak smoke into the room
through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates
excessive draft.
To
Appliance
-10-
FACTORY BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You
must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through
and “T” section package, restops (where needed), insulation shield, roof ashing, chimney cap, etc. Maintain
proper clearance to the structure as recommended by the manufacturer. The chimney must be the required
height above the roof or other obstructions for safety and proper draft operation.
-11-
TYPE
WEIGHT
(LBS. CU.
FT., DRY)
PER
CORD
EFFICIENCY
RANKING
SPLITS
MILLIONS
BTU’s/
CORD
Hickory 63 4500 1.0 Well 31.5
White Oak 48 4100 .9 Fair 28.6
Red Oak 46 3900 .8 Fair 27.4
Beech 45 3800 .7 Hard 26.8
Sugar Maple 44 3700 .6 Fair 26.2
Black Oak 43 3700 .6 Fair 25.6
Ash 42 3600 .5 Well 25.0
Yellow Birch 40 3400 .4 Hard 23.8
Red Maple 38 3200 .3 Fair 22.6
Paper Birch 37 3100 .3 Easy 22.1
Elm/Sycamore 34 2900 .2 Very Difcult 20.1
Red Spruce 29 1800 .1 Easy 16.1
WOOD STOVE UTILIZATION
It is EXTREMELY IMPORTANT that you use DRY WOOD only in your wood oven. The wood should have dried for 9
to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is very
important to keep in mind that even if the wood has been cut for one, two or even more years, it is not necessarily
dry, if it has been stored in poor conditions. Under extreme conditions it may rot, instead of drying. This point
cannot be over stressed; the vast majority of the problems related to the operation of a wood oven is caused by
the fact that the wood used was too damp or has dried in poor conditions.
These problems can be:
Ignition problems
Creosote build-up causing chimney res
Low energy yield
Blackened windows
Incomplete log combustion
Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split. The wood should not be
stored directly on the ground. Air should circulate through the cord. A 24” to 48” air space should be left between
each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be
protected from the elements but not the sides.
This heater is designed to burn natural wood only. Higher efciencies and lower emissions generally result when
burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
DO NOT BURN:
(1) Garbage;
(2) Lawn clippings or yard waste;
(3) Materials containing rubber, including tires;
(4) Materials containing plastic;
(5) Waste petroleum products, paints or paint thinners,
or asphalt products;
(6) Materials containing asbestos;
(7) Construction or demolition debris;
(8) Railroad ties or pressure-treated wood;
(9) Manure or animal remains;
(10) Salt water driftwood or other previously salt water
saturated materials;
(11) Unseasoned wood; or
(12) Paper products, cardboard, plywood, or
particleboard. The prohibition against burning these
materials does not prohibit the use of re starters made
from paper, cardboard, saw dust, wax and similar
substances for the purpose of starting a re in an
affected wood heater.
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
Dead wood lying on the forest oor should be considered wet, and requires full seasoning time. Standing dead
wood can usually be considered to be about 2/3 seasoned. Splitting and stacking wood before it is stored
accelerates drying time. Storing wood on an elevated surface from the ground and under a cover or covered
area from rain or snow also accelerates drying time. A good indicator if wood is ready to burn is to check the
piece ends. If there are cracks radiating in all directions from the center then the wood should be dry enough
to burn. If your wood sizzles in the re, even though the surface is dry, it may not be fully cured, and should be
seasoned longer
Waste and other ammable materials should not be burned in your oven. Any type of wood may be used in
your oven, but specic varieties have better energy yields than others. Please consult the following table in order
to make the best possible choice.
-12-
TESTING YOUR WOOD
When the oven is thoroughly warmed, place one piece of split wood (about ve inches in diameter) parallel to
the door on the bed of red embers. Keep the air control full open by pulling on it and close the door. If ignition
of the piece is accomplished within 90 seconds from the time if was placed in the oven, your wood is correctly
dried. If ignition takes longer, your wood is damp. If your wood hisses and water or vapor escapes at the ends of
the piece, your wood is soaked or freshly cut. Do not use this wood in your oven. Large amounts of creosote could
be deposited in your chimney, creating potential conditions for a chimney re.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
THE FIRST FIRES
The fresh paint on your stove needs to be cured to preserve its quality. Once the fuel charge is properly ignited,
only burn small res in your stove for the rst four hours of operation. Never open the air control more than
necessary to achieve a medium burn rate. Make sure that there’s enough air circulation while curing the stove.
The odors could be smelled during the 3 or 4 rst res. Never start your stove outside. You will not be able to see
if you are over heating.
The amount of visible smoke being produced can be an effective method of determining how efciently the
combustion process is taking place at the given settings. Visible smoke consist of unburned fuel and moisture
leaving your stove. Learn to adjust the air settings of your specic unit to produce the smallest amount of visible
smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess
visible smoke and burn poorly.
CAUTION: Never alter the damper slide or the adjustment range to increase ring for any reason. Doing so
could result in heater damage and will void your warranty.
CAUTIONS:
Ashes could contain hot embers even after two days without operating the stove.
The ash pan can become very hot. Wear gloves to prevent injury.
Never burn the stove with the stove door or ash clean out opening unsealed . This would result in over ring
the stove. Damage to the stove and even house re may result.
Primary Air Settings
(Slide Damper is located in center of stove under hearth plate)
(Damper Adjustment: Pulling out on damper decreases air)
Electric Blower Speed Setting (Variable)
(Blower is on High when turned “ON”, Rotate
clockwise until stop for “LOW”.)
Burn Rate Adjust Damper from fully closed Burn Time Blower Speed
Low Closed @ 30 minutes Low
Medium - Low 5/16” @ 30 minutes Low
Medium - High 9/16” @ 30 minutes Low
High Fully Open all minutes High
IGNITION
After making sure that the stove air intake controls are fully open (completely pull-out towards you), place
several rumpled sheets of paper in the center of the combustion chamber. Place 8 to 10 pieces of small dry
kindling wood over the paper in the form of a tent. You may also place a few pieces of heating wood, but
choose the smaller ones. No chemical product should be used to light the re.
Before igniting the paper and kindling wood, it is recommended that you warm up the chimney. This is done
in order to avoid back draft problems often due to negative pressure in the house. If such is the case, open a
window slightly near the stove and twist together a few sheets of newspaper into a torch. Light up this paper
torch and hold it as close as possible to the mouth of the pipe inside the combustion chamber to warm up
the chimney. Once the updraft movement is initiated, you are ready to ignite the stove by lighting the paper
and kindling wood inside the combustion chamber. When you have achieved a good bed of hot embers, we
recommend the following burn procedures:
-13-
WARNINGS:
Never overre your stove. If any part of the stove starts to glow red, over ring is happening. Readjust the
air intake control at a lower setting.
The installation of a log cradle or grates is not recommended in your wood stove. Build re directly on
rebrick.
Never put wood above the rebrick lining of the rebox.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
OPERATION
Controlled combustion is the most efcient technique for wood heating because it enables you to select the type
of combustion you want for each given situation. The wood will burn slowly if the wood stove air intake control is
adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On the other hand, wood will
burn quickly if the air control is adjusted to admit a larger quantity of oxygen in the combustion chamber. Refer
to the primary air settings table for damper operation setting. Real operating conditions may give very different
results than those obtained during testing according to the species of wood used, its moisture content, the size
and density of the pieces, the length of the chimney, altitude and outside temperature.
EFFICIENCIES
Efciencies can be based on either the lower heating value (LHV) or the higher heating value (HHV) of the fuel.
The lower heating value is when water leaves the combustion process as a vapor, in the case of woodstoves the
moisture in the wood being burned leaves the stove as a vapor. The higher heating value is when water leaves
the combustion process completely condensed. In the case of woodstoves this would assume the exhaust gases
are room temperature when leaving the system, and therefore calculations using this heating value consider
the heat going up the chimney as lost energy. Therefore, efciency calculated using the lower heating value of
wood will be higher than efciency calculated using the higher heating value. In the United States all woodstove
efciencies should be calculated using the higher heating value.
The best way to achieve optimum efciencies is to learn the burn characteristic of you appliance and burn well-
seasoned wood. Higher burn rates are not always the best heating burn rates; after a good re is established a
lower burn rate may be a better option for efcient heating. A lower burn rate slows the ow of usable heat out
of the home through the chimney, and it also consumes less wood.
The top down method of re building is recommended for this appliance. After making sure that the stove air
intake controls are fully open (completely pull-out towards you), Place the largest pieces of wood on the bottom,
laid in parallel and close together. Smaller pieces are placed in a second layer, crossways to the rst. A third layer
of still smaller pieces is laid crossways to the second, this time with some spaces between. Then a fourth layer of
loose, small kindling and twisted newspaper sheets tops off the pile.
OPERATIONAL TIPS
Get the appliance hot and establish a good coal bed before adjusting to a low burn rate (this may take 30
minutes or more depending on your wood)
Use smaller pieces of wood during start-up and a high burn rate to increase the stove temperature
Be considerate of the environment and only burn dry wood
Burn small, intense res instead of large, slow burning res when possible
Learn your appliance’s operating characteristics to obtain optimum performance
Burning unseasoned wet wood only hurts your stoves efciency and leads to accelerated creosote buildup
in your chimney
-14-
RELOADING
Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air
controls to maximum a few seconds prior to opening the stove’s door. Then proceed by opening the door very
slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to increase the draft and thus
eliminate the smoke which is stagnant in a state of slow combustion in the stove. Then bring the red embers to
the front of the stove and reload the unit.
For optimal operation of your wood stove, we recommend you to operate it with a wood load approximately
equivalent to the height of re bricks.
It is important to note that wood combustion consumes ambient oxygen in the room. In the case of negative
pressure, it is a good idea to allow fresh air in the room, either by opening a window slightly or by installing a fresh
air intake system on an outside wall.
Creosote - Formation and Need for Removal when wood is burned slowly, it produces tar and other organic
vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively
cool chimney ue of a slow-burning re. As a result, creosote residue accumulates on the ue lining. When
ignited, this creosote makes an extremely hot re. The chimney connector and chimney should be inspected
at least once every two months during the heating season to determine if a creosote build-up has occurred. If
creosote has accumulated (3mm or more), it should be removed to reduce the risk of a chimney re.
We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately
18” above the stove. This thermometer will indicate the temperature of your gas exhaust fumes within the smoke
exhaust system. The ideal temperature for these gases is somewhere between 275°F and 500°F. Below these
temperatures, the build-up of creosote is promoted. Above 500 degrees, heat is wasted since a too large quantity
is lost into the atmosphere.
To Prevent Creosote Build Up: Always Burn Dry Wood. This Allows Clean Burns And Higher Chimney
Temperatures, Therefore Less Creosote Deposit.
Leave the air control full open for about 5 min. every time you reload the stove to bring it back to proper
operating temperatures. The secondary combustion can only take place if the rebox is hot enough.
Always check for creosote deposit once every two months and have your chimney cleaned at least once a
year.
If a chimney or creosote re occurs, close all dampers immediately. Wait for the re to go out and the heater to
cool, then inspect the chimney for damage. If no damage results, perform a chimney cleaning to ensure there is
no more creosote deposits remaining in the chimney.
ASH DISPOSAL
Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always
empty the stove when it is cold, such as in the morning. Disposal of Ashes: Ashes should be placed in a metal
container with a tight tting lid. The closed container of ashes should be placed on a noncombustible oor or
on the ground, well away from all combustible materials, pending nal disposal. If the ashes are disposed of by
burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have
thoroughly cooled. Other waste shall not be placed in this container.
SMOKE AND CO MONITORS
Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods of time. While the modern combustion systems in
heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or conned
areas can be dangerous. Make sure you stove gaskets and chimney joints are in good working order and sealing
properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas
having the potential to generate CO.
-15-
Your wood stove is a high efciency stove and therefore requires little maintenance. It is important to perform
a visual inspection of the stove every time it is emptied, in order to insure that no parts have been damaged,
in which case repairs must be performed immediately. Inspect and clean the chimney and connector pipe
periodically for creosote buildup or obstructions.
GLASS
Inspect and clean the glass regularly in order to detect any cracks. If you spot one, turn the stove off
immediately. Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is
broken.
If the glass on your stove breaks, replace only with the glass supplied from your heater dealer. Never
substitute other materials for the glass.
To replace the glass, remove the screws retaining the glass mouldings inside the door. Remove the
mouldings and replace the damaged piece with a new one. Perform the procedure backwards after
replacing. When replacing the glass, you should change the glass gasket to make sure you keep it sealed.
Never wash the glass with a product that may scratch. Use a specialized product, available in the stores
where wood stoves are sold. The glass should be washed only when cold.
GASKETS
It is recommended that you change the door gasket (which makes your stove door air tight) once a year, in
order to insure good control over the combustion, maximum efciency and security. To change the door gasket,
simply remove the damaged one. Carefully clean the available gasket groove, apply a high temperature
silicone sold for this purpose and install the new gasket. You may light up your stove again approximately 24 hours
after having completed this operation. This unit’s door uses a 1/2” diameter rope gasket.
WARNING: Never operate the stove without a gasket or with a broken one. Damage to the stove or even
house re may result.
BLOWER (IF EQUIPPED)
The blower needs to be removed and air blown clean. Make sure the blades do not have build up.
SECONDARY AIR TUBES
The secondary air tubes must be cleaned with a wire brush. If debris remains in holes lightly tap with a wooden
stick to remove.
FIREBRICK
The rebrick should be cleaned and inspected as necessary. Replace any damaged or broken brick.
AIR TUBES
The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to insure the
highest efciency. Any damage or deterioration of these tubes may reduce the efciency of combustion. The
air tubes are held in position by either screws or snap pins. Locate these to either side of the tube and remove to
allow the tube to be removed and replaced.
Maintenance
CAUTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
-16-
PAINT
Remember to only clean your stove with a dry soft cloth that will not harm the stoves nish.
Your stove has two types of coatings that are used in the nal nish; porcelain enamel and high temperature
stove paint.
ENAMEL REPAIR
The porcelain enamel nish will maintain its color and luster for the life of the stove. However, because it is glass
it may chip if hit with a hard or sharp object. If you experience a scratch or chip in the porcelain enamel nish,
specially formulated gloss touch up paint can be used. Contact you stove dealer to request a small bottle of this
touch up paint.
1. Ensure the stove is cool.
Note: The paint may be applied to a warm stove, but the temperature of the section to be painted should be
below the boiling temperature
(200°F) to achieve a smooth nish.
2. The area should be built up with multiple thin coats.
Note: Better results are obtained if the stove is brought up to operational temperatures between coats.
HIGH TEMPERATURE STOVE PAINT REPAIR
If the painted portions of your stove need re coating it is possible to give those pieces a brand new look by
repainting it with a 1200°F heat resistant stove paint.
1. Scrub the surface to be repainted with ne sand paper.
2. Clean it properly.
3. Apply thin coats (2-3) of paint successively.
During the curing process there are changes in the paint causing it to give off an odor and some visible
smoke. The fumes are non-toxic, but can be unpleasant. Ventilate and vacate the room to avoid discomfort.
Once the curing is complete there will be no odor or smoke. After re-coating portions of your stove
remember to follow the curing process as discussed in the rst re section of this manual.
STOVE MORTAR REPAIR
Sometimes after the cement on the outside of the stove dries and hardens, it will develop some cracks. Thermal
expansion, growth and shrinkage of the cast-iron do to changing temperatures, may contribute to cracks or
chips in the mortar. If you desire to make repairs on your stove mortar contact your stove dealer to request
replace mortar to perform the repair.
REPAIR INSTRUCTIONS
1. Remove any loose pieces of mortar.
2. Using masking tape or blue tape, line both sides of each seam.
3. Cut the tip of the mortar tube for a 1/8” to 3/16” bead.
4. Fill any large voids.
5. Run a continuous bead of grout the entire length of the seam.
6. Smooth the bead to the size of llet desired. Smaller is better.
7. Stop and remove any excess before it spreads beyond the tape.
Note: You may have to do this several times before you can run the full length of the seam.
8. Carefully remove the tape.
9. Using a damp (not soaked) small cell sponge or cotton cloth, run the length of the seam to atten the edge
of the mortar and remove any cement that spread beyond the llet.
10. Rinse the sponge or cloth often.
Note: You must get everything off of the enamel before it dries.
The mortar contains sodium silicate that will etch the porcelain nish if not removed promptly.
It is better to remove too much rather than to make the llet too large.
11. Allow the mortar to dry overnight before ring up the stove.
-17-
Troubleshooting
High Fuel Consumption
Possible Cause Possible Remedies (Unplug blower rst if equipped)
Improper regulation of draft or air inlet
Close air inlet control as much as possible to maintain desired heat
output.
Check all gaskets, reinstall if necessary (see maintenance for gasket
replacement procedure).
Improper door tting
Check door gasket, reinstall if necessary (see maintenance for gasket
replacement procedure).
Check door latch adjustment. Readjust if necessary.
Back Pufng
Possible Cause Possible Remedies (Unplug blower rst if equipped)
Gusts of wind Chimney may need wind diverter
2-10-3 rule not properly maintained Raise chimney to appropriate height
Chimney Blockage
Smoke shelf in chimney is lled with creosote, soot and ash
Tree limb or other obstruction too close
Persistent soot, creosote or ash build up in chimney
Possible Cause Possible Remedies (Unplug blower rst if equipped)
Cool exhaust ue gasses Use double or triple wall external chimney
Burning unseasoned / wet wood Use dry, seasoned hardwood
Smoke rolls out when feed or ash doors are opened
Possible Cause Possible Remedies (Unplug blower rst if equipped)
Wind Gusts blowing down the chimney
Smoke shelf in chimney is lled with creosote, soot and ash
Chimney may need wind diverter
Opening heater door too soon
Open air control, crack door for 5-10 seconds before fully opening
door
Low Heat Output
Possible Cause Possible Remedies (Unplug blower rst if equipped)
Obstruction in chimney Check for blockage in chimney, remove if necessary
Improperly sealed venting
Check all gasketing, replace if necessary
Check exhaust venting seals, reseal if necessary
Wet or unseasoned wood being burned Burn dry, seasoned hard wood
Improper wood loading Load wood according to directions under utilization
Poor chimney draft
Improper chimney height or wrong size ue in use
Inspect chimney for soot, creosote and ash buildup, clean if
necessary.
-18-
REPAIR PARTS
Key Part No Description
Qty
1 40619 Top Cast Grate Left 1
2 40620 Top Cast Grate With Flue 1
3 69942 Heatshield Weldment 1
4 40621 Top Cast Grate Right 1
5 891492 Blower Assembly 1
6 83614 15" Threaded Rod 4
7 88147 Bafe Board 1
8 86655 Secondary Air Tube, Rear 1
9 86656 Secondary Air Tubes 2
10 89066 Firebrick (4-1/2 X 9) 6
11 891414 Half Firebrick 4
12 891095 Firebrick (6 X 8-1/4) 3
13 891987 Plastic Knob 3
14 69945 Weldment, Ash Pan 1
15 86668 Damper Rod 1
16 88174 Gasket-Flat 1
In order to maintain warranty, components must be replaced using original manufacturers parts
purchased through your dealer or directly from the appliance manufacturer.
Use of third party components will void the warranty.
1
2
3
6
5
14
13
16
15
7
8
10
11
12
9
4
-19-
In order to maintain warranty, components must be replaced using original manufacturers parts
purchased through your dealer or directly from the appliance manufacturer.
Use of third party components will void the warranty.
When ordering cast-iron repair parts
you must specify the desired color.
Cast Repair Parts Color
Key Description
M Mahogany
R Red
B Black
A Almond
Key Part No Description Qty
1 40675 Glass Brace 1
2 88087 Fiberglass Gasket 1
3 892342 Door Glass 1
4 88057 1/2” Robe Gasket 3.5’
5 40695 Cast Door W/Webbing 1
6 40626 Door Latch 1
7 892352 Plastic Handle 1
REPAIR PARTS
3
5
4
6
7
2
1
-20-
Limited Warranty
Plate Steel Heaters
(Inserts, Freestanding, and Pedestal)
The operation of this heater in a manner inconsistent with the owner’s manual will void the warranty and is also against federal regulations.
United States Stove Company warrants to the original purchaser its products against premature failure of any component due to workmanship, quality, or
materials as follows:
TIME PERIOD:
Firebox ...................................................................................................................................... Three Years
Flue Collar - if equipped .............................................................................................................. Three Years
All Doors .................................................................................................................................... Three Years
Firebox Baffl e ................................................................................................................................. One Year
Door Gaskets ................................................................................................................................. One Year
All Electrical Components (Including Blower) - if equipped ................................................................. One Year
Cabinet and Trim ............................................................................................................................ One Year
CLAIM PROCEDURE
Any defects should be reported to United States Stove Company or its dealer and/or distributor giving descriptions and pertinent data, including proof or
purchase which will be returned upon request.
Providing the heater has been installed and used in accordance with the Owners Manual supplied with the heater, United States Stove Company will either:
1) Replace the defective part free of charge
2) Replace the heater free of charge
3) Where the defect is of a cosmetic (non-functional) nature, United States Stove Company will bear reasonable expense to refurbish the heater,
including such items as welding, painting, and incidental labor. A “Reasonable” is defi ned by terms of this warranty as $30.00/hour with full refund for
any purchase of parts.
NOT COVERED
Specifi cally not covered under terms of this limited warranty or any other warranty are problems relating to smoking or creosote. Smoking is attributable
to inadequate draft due to the design or installation of the ue system or installation of the heater itself. Creosote formation is largely attributable to
improper operation of the unit and/or draft as mentioned above. Also, not covered are:
1) Removal and re-installation cost.
2) Service calls to diagnose trouble (unless authorized in writing by the manufacturer, distributor, or dealer).
3) Painted surfaces, brass or brass-colored surfaces.
4) Damage or defect caused by improper installation, accidents, misuse, abuse (including overfi ring) or alteration.
5) Transportation or shipping costs.
LIMITATIONS AND EXCLUSIONS
1) United States Stove Company shall not be liable for incidental, consequential, special, or contingent damages anyone might suffer as a result of their
breach of this written warranty or any implied warranty.
2) Should the heater be replaced by United States Stove Company “free of charge”, all further warranty obligations are thereby met.
3) Parts and/or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty.
4) Without specifi c written exclusionary waivers, no one has authority to add to or vary this limited warranty, or to create for United States Stove
Company any further obligation of liability in connection with this heater or any other applicable accessory. Any further warranty implication applicable
to this heater or any applicable accessory is limited in duration to the same time period as the original statement in the above schedule.
YOUR DUTIES
1) This heater, including all applicable accessories, must be installed and operated in accordance with local authorities having jurisdiction and the
instructions furnished with the Owners Manual.
2) You should keep as permanent record your proof of purchase (or canceled check or invoice).
PROBLEM/RESOLUTION
1) As purchaser, you must fi rst contact the dealer and/or distributor from whom you purchased your heater.
2) If within a reasonable period of time you do not receive satisfactory service from the distributor and/or dealer, write or call United States Stove
Company, Customer Service Department, including complete details of the problem and/or problems you are experiencing, details of your installation,
your proof of purchase, and the heater serial number or test agency code number.
WARRANTOR
The warrantor of record is United States Stove Company, PO Box 151, 227 Industrial Park Road, South Pittsburg, Tennessee 37380.
Phone number 800-750-2723
• Web site www.usstove.com
NOTE
This warranty gives you specifi c legal rights; and, you may also have other rights which vary from state to state. Register your product on line at
www.usstove.com. Save your receipt with your records for any claims.
IMPORTANT
We congratulate you on your selection of United States Stove Company and its products. As the oldest solid fuel manufacturer in the United States
(since 1869), the United States Stove Company is very proud of its products, service, employees, and satisfi ed customers. We would like to hear
from you if you are not satisfi ed with the manner in which you have been handled by our distributor, dealer, representative, customer service
department, parts department, or sales department. Please reach out to us by using any of the contact information listed above.
85989L
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Ashley Hearth Products AC1100 Manuel utilisateur

Catégorie
Poêle à bois
Taper
Manuel utilisateur

dans d''autres langues