PROGRAMMING
• Enter ENGINEER’S CODE: rst time type six times 1 (111111
factory preset) and press ENTER (The red LED will illuminate).
• Conrm ENGINEER’S CODE (typing again the same) or
type the new code (4 to 8 digits) then press ENTER (Melo-
dy). Pressing twice the ENTER button without changing the
ENGINEER’S CODE, will exit from the programming.
•Enter the code (4 to 8 digits) to enable RELAY 1 (ACCESS 1) or
re-enter the existing code then press ENTER (Melody).
•Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody).
•Enter the code (4 to 8 digits) to enable RELAY 2 (ACCESS 2) or
re-enter theexisting code then press ENTER (Melody).
•Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00=remain open time) or re-enter the existing time
then press ENTER (Melody).
•Enter the code (4 to 8 digits) to enable RELAY 3 (ACCESS 3
only for Art.8800-3) or re-enter the existing code then press
ENTER (Melody).
•Enter the RELAY 3 (only for Art.8800-3) operation time (2 dig-
its 01 to 99 I.E. 05=5 seconds, 00=remain open time) or re-en-
ter the existing time then press ENTER (Melody).
• The system is ready to use (the red LED will be o).
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
• Turn o power to code lock;
• Keep ENTER button pressed while turning the power back on;
• Release ENTER button;
• The engineer’s code is now set to 111111 (six times one).
OPERATION
To use the system, type in the programmed code and press ENTER, the green LED will illuminate and the relay will operate for the
programmed time.To cancel remain open time, type in the same code and press CLEAR. If a wrong code is entered, a continuous
melody will sound for 4 or more seconds, according to the number of mistakes
.
OPERATION NOTES
• To operate relays together, set the same code for each relay;
• If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will
operate only when the correct code is enter
ENTER THE
"ENGINEER’S CODE"
CONFIRM
OR CHANGE
"ENGINEER’S CODE"
ENTER
"ACCESS 1 CODE"
ENTER
"ACCESS 2 CODE"
ENTER
"ACCESS 3 CODE"***
ENTER
"ACCESS 1 TIME"
ENTER
"ACCESS 2 TIME"
ENTER
"ACCESS 3 TIME"***
SYSTEM
READY TO USE
First time six times
1 “111111” factory
preset
Type again six times
“1” or the new en-
gineer’s code 4 to 8
digits
Code to enable relay 1
4 to 8 digits
Code to enable relay 2
4 to 8 digits
Code to enable relay 3
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
00= remain open
Two digits (01 to 99)
i.E. 05=5 Seconds
Two digits (01 to 99)
i.E. 05=5 Seconds
Red led will be o
Press Enter
(Red LED will
be ON)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
*** Only for Art.8800-3