NSS Charger 2717DB & Charger 2022DB Manuel utilisateur

Taper
Manuel utilisateur
OPERATION MANUAL
CHARGER 2717 DB & CHARGER 2022 DB
Original Instructions
Instructions D'origine
Instrucciones Originales
OPERATION MANUAL
CHARGER 2717 DB & CHARGER 2022 DB
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to observe these instructions can cause
personal injury to machine operator or bystanders.
WARNING: Fire or explosion hazard.
NEVER operate this machine in an
explosive atmosphere (grain dust,
flammable liquids or fumes, etc.).
WARNING: Fire or explosion hazard.
NEVER use flammable liquids (gas,
kerosene, solvents, or thinners) to
clean or burnish floor.
WARNING: This product contains a chemical known to the state of California to cause
cancer and birth defects or other reproductive harm.
INTENDED USE
NSS Burnishers are intended for commercial use,
buffing and burnishing floors in an indoor environment.
It is not intended for spray burnishing.
NSS Burnishers are Twister Approved.
NSS does not recommend using these machines for
any other purpose.
FOR SAFETY
ALWAYS read and understand all instructions before
operating or servicing machine.
ALWAYS use this machine ONLY as described in
this manual.
NEVER attempt to operate this machine unless you
have been trained in its operation.
NEVER allow an untrained person to operate this
machine.
ALWAYS operate this machine from the rear control
panel, not from the side.
ALWAYS turn off master switch when attaching or
changing pads.
NEVER attempt to operate this machine if it is not
working properly or has been damaged in any
manner.
NEVER disconnect or modify any switches or safety
devices (circuit breaker).
NEVER drop or insert any object into any machine
opening.
NEVER operate this machine with any air opening
blocked. Keep all air openings free of dust, lint, hair,
etc.
NEVER pick up anything that is burning or smoking,
such as cigarettes, matches or hot ashes.
NEVER allow this machine to be used as a toy. Close
attention is necessary when used by or near children.
ALWAYS wear clean tennis shoes or “non-slip” shoes.
Leather soled shoes will be extremely slippery.
ALWAYS keep face, fingers, hair or any other body
part or loose clothing away from any machine opening
or moving part (revolving pad driver).
ALWAYS be sure that the ramp is secured to the
vehicle before attempting to load / unload.
ALWAYS use extreme caution when operating the
machine on a ramp or loading / unloading this machine
into or out of a truck / trailer. Use extreme caution if
the ramp is wet, oily, or covered with cleaning
chemicals.
NEVER stop or turn the machine on a ramp or incline.
NEVER attempt to climb a grade or operate this
machine on a ramp or incline of more than 20 degrees.
ALWAYS store this machine indoors in a dry, cool
area.
NEVER park or store the machine near a dock, on
ramps, near a furnace, boiler, open flame, or other
high heat source.
NEVER spray this machine with water or any liquids.
NEVER allow the battery charging plug to get wet or a
short may occur.
NEVER operate this machine when the battery
charger is plugged in.
NEVER operate the machine outdoors or allow
machine to freeze.
NEVER expose the machine to rain, snow, or extreme
temperatures.
NEVER store any items on the machine.
ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR /
SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.
IMPORTANT SAFETY INSTRUCTIONS
BATTERY POWERED EQUIPMENT WITH ON BOARD CHARGERS
WARNING: Failure to observe these instructions can cause personal
injury to machine operator or bystanders.
GENERAL
ALWAYS read and understand all instructions before
installing or charging batteries.
NEVER attempt to install or charge batteries unless
you have been trained to do so.
NEVER allow an untrained person to install or charge
batteries.
ALWAYS remove all jewelry when working on or
near the batteries.
ALWAYS turn off all switches during installation and
service.
ALWAYS disconnect the battery leads before
performing any service or repair.
ALWAYS wear eye protection, rubber gloves and
protective clothing to avoid contact with battery acid.
NEVER lay anything on top of batteries as arcing
may occur.
IF CONTACT WITH BATTERY ACID OCCURS,
follow these instructions:
SKIN – rinse area with water.
EYES – Flush with water for 15 minutes.
INTERNAL – Drink water or milk. Follow with Milk
of Magnesia, beaten egg or vegetable oil. Call a
physician immediately.
BATTERY INSTALLATION
ALWAYS use two people to install, as batteries are
heavy.
ALWAYS turn off all machine switches.
ALWAYS position batteries as shown on the
machine installation decal to maintain machine
balance.
ALWAYS connect batteries as shown on the
machine installation decal to avoid shorting out the
batteries and the electrical system.
BATTERY CHARGING
ALWAYS read instructions on charger carefully.
ALWAYS use the NSS supplied charger with proper
voltage rating.
For lead acid batteries only, (does not apply to gel
cell or maintenance free batteries).
ALWAYS check to ensure the battery water level
covers the battery plates before charging.
ALWAYS check water level after charging and add
distilled water if necessary to bring level to the bottom
of the fill hole.
NEVER
overfill batteries as
battery
and machine damage may
result.
ALWAYS wipe any acid from the top of batteries
using a soap solution.
ALWAYS reattach caps to batteries. Do not charge
with caps loose or removed.
ADD only distilled water.
For All Types of Batteries
ALWAYS study battery manufacturers’ specific
precautions such as recommended rates of charge.
NEVER charge a frozen battery.
ALWAYS plug the charger into an earthed socket-
outlet.
NEVER touch uninsulated portion of output connector
or uninsulated battery terminal.
ALWAYS disconnect the AC supply before making or
breaking the connections to the battery while
charging.
NEVER open or disassemble charger.
NEVER operate charger if the AC supply cord is
damaged or if the charger has received a sharp blow,
been dropped, or otherwise damaged in any way.
Read and understand all
instructions before installing
or charging batteries.
No smoking, open
flames, or sparks while
working with batteries.
Contains acid.
Avoid contact
Poison. Causes
severe burns. Avoid
contact.
WARNING: Batteries emit hydrogen, which can cause fire or explosion.
NEVER smoke, light a match, or cause a spark during operation or charging.
ALWAYS char
g
e in a well-ventilated area awa
y
from o
p
en flame.
ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR/
SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS
NOISE AND VIBRATION
MACHINE INSPECTION
Now that the machine is unpacked remember to
recycle all packing materials.
Inspect the machine for damage or missing
components. If damage is found, contact the
freight company to file a freight claim.
MACHINE OPERATION
General Information
This machine works best with dry polishing or
burnishing. Use mop on restorers rather than spray
buff systems to restore the shine.
Spray buffing is time consuming and uses more pads
because they become loaded with floor finish, which
can cause overloading of the machine’s control
system.
Quick Start
Connecting Battery Pack to Machine
When the machine is shipped with batteries, the
machine will arrive with the battery pack
disconnected from the machine.
Lift up on the handle on the top cover to expose the
battery pack.
Connect the cable with the Anderson connector
into the Anderson connector mounted to the
machine at the rear of the battery compartment in
front of the control column.
For machines shipped without batteries
See Battery Installation in the Maintenance Section
later in this manual.
Lower Brush/Pad to Operating Position
Move the front of the machine from/to pad
changing position or operating position by grasping
the handle and moving it to the desired position.
Turn on master switch (and key switch if so
equipped). Wait until you hear a click, the machine
is now on. See Machine Components for more
information.
Check that the battery meter is reading in the high
or green range. The machine should be put on
charge if not in the high range. See Charging
Instructions later in this manual.
Turn on brush switch. See Machine Components
for more information.
Twist the handle grips forward (away from you) to
activate the Pad and Drive Motors. To move
backward twist the handle grips backward (toward
you). See Machine Components for more
information.
CAUTION: This Machine must be moving at all
times when the pad is rotating or the floor may be
damaged.
Transporting the Machine to Work Site
NSS recommends transporting the machine to the
work site with the front of the machine in the
operating position and the brush switch in the off
position. This will reduce the potential of damage to
the Flexiwall Shield and Pad Driver when moving
through stock/storage rooms and double swinging
doors.
For questions and all information pertaining to
this machine read the rest of this manual.
NOISE
Sound pressure level at Operator
position
(
ISO 11201
)
68 dB(A)
VIBRATION
Weighted RMS acceleration value
(
ISO 5349
)
.269 m/s
2
MACHINE COMPONENTS
Operator Control Column
The operator control column is located at the rear of
the machine. This column has components that
control various machine functions.
Drive System Control
At the top on both sides of the control column are
two (2) rubber twist grips. These grips rotate
forward and backward to control the direction and
speed of the machine.
They also activate the Brush Motor so it is only on
when the machine is moving. The farther the grips
are rotated, the faster the machine will move.
These twist grips have a safety feature that returns
the machine to the neutral position when the
handles are released.
Battery Meter
The battery meter is located in the back of the control
column cover and has two uses. It shows the state of
charge of batteries during operation and flashes fault
codes when there is a problem with the machine.
The rate of charge is indicated by numbers. The
higher the number the greater the charge in the
battery pack.
When there is a fault with the machine, the Battery
Meter will flash an “F” followed by a number.
See Trouble Shooting Chart for more
information.
Battery Charger
The battery charger is located on top of the battery
box cover.
This high efficiency battery charger is designed for
onboard operation.
Master Switch
The master switch is located on the top right side
of the control column and it turns the machine on
and off.
If the brush switch is on and the brush head is
down or the twist grips are not in the neutral
position the machine will not turn on. A flashing
fault code will appear on the battery meter. See the
bottom of the decal on control column cover and
correct the problem.
The control system will automatically turn the
machine off if it sets idle for 10 minutes. Turned off
the master and brush switch and then turn the
master switch back on to restart.
Hour Meter
The hour meter is located under the Master Switch
and counts the hours the brush motor is on. The
hour meter is used for indicating maintenance
intervals. The hour meter cannot be reset.
See maintenance section for maintenance
intervals.
Fuse Holder
The fuse holder is located under the Hour Meter. It
houses a 2 AMP fuse.
Key Switch
A Key Switch is Optional and will be located above
the hour meter when installed. The key switch and
master switch will both need to be used to turn the
machine on and off.
Brush Switch
The brush switch is located on the left side of the
control column and it turns the brush on and off.
There is also a tilt switch in this circuit located
under the brush head that only allows the brush to
be turned on when the brush head is in the
operating position.
Circuit Breaker
There is one master circuit breaker located below
the brush switch on the control column.
Brush Head
The brush motor, Filter Bag and Flexiwall shield
are located at the front of the machine.
The bag connects directly to the Flexiwall shield
and has a snap that retains the rear of the bag.
MAINTENANCE
ALWAYS turn OFF all machine switches
before performing any maintenance or
repairs to any equipment.
Check the tension of the Drive Chain after the
first 100 hrs of use and then every 90 days or 300
hours as needed. For the chain tightening
instructions see the maintenance section called
90 Day Maintenance (300 Hours).
Daily Maintenance
Never leave the machine sit with a used pad
installed. This can cause the pad driver to warp.
Pad Installation / Changing
There is a wide range of pads available for many
different burnishing applications. Consult your local
NSS authorized distributor for application
recommendations.
Lift the front of the machine up to the 90-degree
position to view the pad driver and pad.
Make sure that the correct pad (7/8" to 1" [22mm to
25.4mm]) X 27" [68.6 cm] is being installed.
Place the pad flat on the floor, and remove the
center hole of the pad, step on the center of the
pad to compress the edges around the center hole.
This allows for easier installation of the pad
centering cup.
With the machine in the pad changing position,
carefully center the pad on the driver.
Caution: Pads must be installed concentric (evenly
aligned) with the outside edge of the pad driver.
Failure to follow these precautions will cause
excessive machine vibration, a reduction in pad life
and produce unsatisfactory burnishing results.
Place the pad grabber in the center hole of the
pad.
Holding the pad driver and pad, push on the pad
grabber until the spring clip has clicked twice.
Caution: Failure to install the pad grabber tightly
may allow the pad to be thrown from the driver.
Daily Maintenance (continued)
Empty the filter bag daily or when it is
approximately one-half (1/2) full.
Charging Batteries
Recharge the batteries when indicated by the
Battery Meter.
Never let the batteries sit overnight after the
machine has been run for 1hr or more since last
recharge.
NEVER let the electrolyte level fall below the tops
of the plates. This will damage the batteries
immediately, and void the warranty.
Check charger cord for exposed wires and
damaged plugs before using.
To recharge the batteries plug the charger cord into
the charger located on top of the machine and then
into an electrical outlet.
When the cord is plugged into an outlet the
machine will automatically become disabled.
Charge the batteries with the cover open when
possible to reduce heat build up in the batteries.
See charging instructions for more details.
ALWAYS wear eye protection, rubber gloves and
protective clothing to avoid contact with battery
acid when working around batteries.
After charging batteries check the water level of
each battery cell and add distilled water as
required to level specified by battery manufacturer.
Check and verify that all battery connections are
clean and tight.
Wipe machine down with a damp cloth.
NEVER spray this machine with water or any
liquids.
ALWAYS Check the tilt switch for proper
operation. With the master switch turned off, put
the brush head into the pad change position. Turn
the brush switch on then the master switch on, the
machine should turn on.
If the machine does not turn on and the battery
meter is flashing a one, the tilt switch has failed.
DO NOT use the machine until the tilt switch has
been replaced.
Opportunity Charging
Opportunity charging is charging the batteries when
an opportunity presents itself, such as during breaks,
and is done in addition to a full charge cycle.
Opportunity charging is recommended, as this extra
charging time will help raise the operating voltage of
the batteries, and will help ensure maximum runtime
and cycle life.
See Monthly Maintenance and Operating Battery
Charger Instructions for equalizing your batteries
especially if you have been opportunity charging
your machine.
Weekly Maintenance (Every 25 Hrs)
Verify all daily maintenance has been performed.
Inspect the Flexiwall Shield for dents around the
outside edge and cracks in the plastic.
Check that the Brush and Retaining Band are
properly installed.
Remove dirt build up on the brush along the
bottom of the Flexiwall Shield.
A damaged Flexiwall Shield Assembly will greatly
reduce dust control capabilities of the machine.
Monthly Maintenance
(Every 100 Hrs)
Verify that all daily and weekly maintenance has
been performed.
Equalize your batteries (Flooded only).
The batteries should be equalized once every 30
days for maximum battery runtime and life.
To equalize the batteries:
Plug in the charger, and fully charge the batteries
(until the green 100% LED is on continuously).
Unplug the charger from the wall outlet, then plug it
back in.
The charger will run for 2hrs, holding the batteries
at a constant voltage, and equalizing each cell.
THIS STEP IS ESPECIALLY IMPORTANT IF YOU
PRACTICE OPPORTUNITY CHARGING.
Check the Battery Tray Drain Hose for liquid level
on a monthly basis.
Spilled liquids from the battery compartment area
are collected in a tray under the batteries. The tray
can be drained using the hose at the right rear of
the machine as shown above.
IMPORTANT: Drain all liquids into an approved
container and dispose of according to your local
and federal regulations.
Inspect the machine components for wear, loose
fasteners, or damage. Pay special attention to all
pivot points and moving parts.
Call an authorized NSS service center for repairs.
90 Day Maintenance
(Every 300 Hrs)
Verify that all daily, weekly and monthly
maintenance has been performed.
Tighten Chain
Check the tension on the drive motor chain. If the
chain has more than ½” [12.7mm] deflection,
tighten as needed.
Access to the bolts for the drive motor are on the
left side of the machine. There are two bolts on top
which are accessed through the holes as shown in
the picture above. There are also two bolts located
below the frame. A total of four bolts.
Lubrication
Lubricate the casters with an industrial grade
bearing grease. Failure to lubricate casters will
cause the machine to maneuver with difficulty and
premature failure of the caster will result.
Lubricate the drive wheel bearings with an
industrial grade bearing grease. The zerk fittings
on the bearings can be accessed from the front of
the machine.
Failure to lubricate drive wheel bearings will cause
the machine to maneuver with difficulty and
premature failure of the bearings will result.
Lube the drive motor chain with a small amount of
grease using a brush. A chain spray can also be
used.
NEVER use your fingers to put the lube on the
chain. Serious injury may occur.
Lubricate all moving parts as required with a small
amount of grease.
DO NOT lubricate the Gas Spring shaft, it does not
require lubrication as it is self lubricating.
Every 6 Months (Every 600 Hours)
Call your Authorized NSS Distributor / Service
Station to have the following services performed.
Verify that all daily, weekly, monthly and quarterly
maintenance has been performed.
Inspect Brush Motor carbon brushes for wear.
Using compressed air, blow the accumulated
carbon brush dust out of the motor.
Replace carbon brush when they measure ½”
[12.7mm] or less in length.
Failure to replace carbon brushes will cause poor
machine performance and possible motor damage.
Check the condition of the batteries.
A battery may be checked using a Hydrometer to
check the specific gravity (strength) of the acid in
each cell. Variations in readings occur due to the
chemical reaction taking place during use.
Always check the specific gravity when the battery
is fully charged.
Replace batteries as needed.
Battery Installation:
Turn off all switches. Disconnect battery pack from
the machine.
ALWAYS wear eye protection, rubber gloves and
protective clothing to avoid contact with battery
acid when installing batteries. See Battery
Warnings on page 3.
Repairs performed by an unauthorized company will void the machine warranty.
If
y
ou re
q
uire assistance findin
g
an authorized service center
,
contact NSS Enter
p
rises.
Remove the side panel and top cover. There are
two bolts (one in each corner) on top of the side
panel and two nuts (one in each corner) at the
bottom of the cover. Note that the nuts at the
bottom are not visible from the side.
The cover will still be attached to the side panel.
Move them out of the way to install the Batteries.
Batteries are heavy – ALWAYS use two people to
install batteries into machine.
Refer to wiring diagram located on the under side
of the cover. Align batteries in compartment the
same as the old batteries or as shown on diagram.
Install battery cables the same as they were on the
old batteries or as shown on wiring diagram
located on the under side of the cover.
NSS recommends replacing the battery cables
when replacing batteries.
Tighten bolts and hex nuts with a wrench.
Install terminal boots over terminals to complete
installation.
CAUTION: Do not short across two terminals with a
wrench.
CAUTION: Loose or improper battery connections
will cause battery or machine damage and possible
personal injury.
Every 12 Months
(Every 1200 Hours)
Call your Authorized NSS distributor / Service
Station to have the following services performed.
Verify that all daily, weekly, monthly and quarterly
maintenance has been performed.
Inspect Drive Motor carbon brushes for wear.
This will require removing the drive motor from the
machine and should only be done by an authorized
NSS Service Station.
Using compressed air, blow the accumulated
carbon brush dust out of the motor.
Replace carbon brush when they measure ½”
[12.7mm] or less in length.
Failure to replace carbon brushes will cause poor
machine performance and possible motor damage.
Gas Spring Service
ALWAYS secure Brush Head in the pad change
position using the strap provided before
attempting any maintenance or repairs to the gas
spring or coil spring assemblies.
Remove the spring clip that secures the gas spring
to the machine. Then pull the gas spring off of the
ball stud. There is a clip and ball stud at each end.
Place one end of the gas spring against a hard
surface and push on it. If you can compress it, it
must be replaced. If you can not compress it, it is
most likely OK.
Pad Pressure Adjustment
The NSS Charger 2717 DB and Charger 2022 DB
is preset at the factory for medium duty
applications. It can be tuned to your specific
application for optimum performance.
ONLY an authorized NSS Service Station should
perform this adjustment.
Tools required for Pad pressure adjustment
1) ¾ open end wrench
2) Clamp on Amp Meter
It is necessary to use a clamp on AMP Meter when
adjusting the pad pressure.
There are many different manufactures and
models of AMP Meters to choose from. Two AMP
Meters are shown above. The one on the left is
AMPROBE Model ACDC-610 and the one on the
left is AMPROBE Model ACDC-400.
Checking the Pad Motor Amperage
First install a new pad on the pad driver. Caution:
Checking the Amps with a used pad will cause the
machine to have high amps when a new pad is
installed.
Lower the Pad Motor into the operating position
and open the cover over the battery compartment.
Put the clamp on AMP Meter around the red
(positive) wire coming from the battery pack to the
machine as shown.
While running the machine read the amp meter.
The amp meter should be reading between 70-80
amps for the Charger 2717 DB & 50-70 amps for
the Charger 2022 DB.
Pad Pressure Adjustment
If adjustment is required, follow these
instructions.
It will be easier to access the lock nut and spring
guide rod assembly with the machine in the pad
change position.
First loosen the lock nut on the spring guide. With
the lock nut loose, the spring guide rod assembly
will be easily turned by grasping the set collar on
the spring guide rod.
Turn the spring rod guide assembly ½ to 1 turn at a
time. A little adjustment goes a long way.
Thread the spring guide rod assembly out of the
ball joint to decrease the pad pressure. Thread the
spring guide rod assembly into the ball joint to
increase the pad pressure.
Every time an adjustment is made check the amps.
This may require a few tries to get it were it should
be.
After the adjustment is made tighten the lock nut
and redo the amp test. If it has not changed the
process is complete.
Fall back setting
If your machine has come totally out of adjustment, or
you need to replace the Spring Rod Guide Assembly
you may need to start from the beginning.
The factory starting setting for the pad pressure on
the Charger 2717 DB is 3/4 of an inch [19mm] from
the set collar to the lock nut.
The factory starting setting for the pad pressure on
the Charger 2022 DB is 1/2 of an inch [12.7mm]
from the set collar to the lock nut.
From this setting, proceed with the Pad Pressure
Adjusted.
Battery Replacement Notes
Entire Pack.
oIt is always recommended to replace all batteries
in the pack at the same time.
One or more batteries out of the pack. This is not
recommended. Replacing just one or two batteries
out of the pack can lead to the following:
Overcharging the new, or the remaining
original, batteries.
Undercharging the new, or remaining
original, batteries.
Over discharging either the new or the
remaining original batteries.
o If you wish to only replace some of the batteries
in the pack, follow these steps for best results:
Replacement batteries must always be of the
same battery manufacturer, model and amp-
hour rating, as the remaining batteries in the
pack.
Never mix batteries from different
manufacturers in the same pack.
Fully charge both the new battery, and the
remaining original batteries. (specific gravity
= 1.265 minimum, use a hydrometer)
Use a replacement battery that is close to the
same age as the remaining original ones.
Do not run the machine as long for about 20
cycles. For example, if you used to get 4 hrs
runtime, only run it for 2.5 hrs, and then
charge the batteries completely.
Opportunity charge whenever possible.
Equalize after 30 days (Flooded only).
The above steps will provide the best
opportunity for the new battery(s) to join the
pack.
Battery Do’s and Don’ts:
a. You do not have to fully discharge the batteries
before charging. They do not have a “memory”.
b. Plug the charger in anytime the machine is not in
use.
c. NEVER let the electrolyte level fall below the tops
of the plates (flooded cell batteries). This will
damage your batteries almost immediately, and
void the battery warranty. They can tell if this
happened.
d. NEVER refill the batteries with well or tap water
(flooded cell batteries).
e. NEVER overfill the batteries (flooded cell
batteries).
f. NEVER let the batteries sit discharged overnight
(or between shifts).
g. ALWAYS check the electrolyte level about every 3
or 4 charge/discharge cycles BEFORE
CHARGING.
h. ALWAYS refill the batteries with distilled water (if
needed) AFTER CHARGING.
i. ALWAYS fully recharge the batteries after use
(until the green LED comes on).
j. ALWAYS equalize the batteries (Flooded only)
every 30 days.
k. NEVER OVER DISCHARGE!
l. NEVER charge GEL batteries with the charger set
to FLOODED/AGM.
m. NEVER charge FLOODED/AGM batteries with the
charger set to GEL. EXCEPTION-CROWN AND
TROJAN AGM’S TO BE CHARGED WITH GEL
SETTING.
Battery charger
The onboard battery charger supplied with this
machine is capable of charging lead acid batteries
from 185 to 350ah capacity. There is no need to
change algorithms or settings based on battery
manufacturer, or battery size.
The charger can also be set to charge flooded (wet)
cell, AGM, or Gel batteries. LED’s on the charger
indicate which type of battery the charger is set to
charge. One setting is for Flooded and (most) AGM
batteries, the other setting is only for Crown and
Trojan AGM and GEL batteries.
Depending on the battery charger model, the charger
can operate on 100/115/230 VAC 1ph 50/60 HZ
power, and will automatically detect these input
voltages. Before connecting the battery charger to
power, check the label on the battery charger to
verify proper input power.
Determining Your Battery Type
CAUTION: DIFFERENT BATTERY TYPES HAVE
DIFFERENT CHARGING REQUIREMENTS.
FAILURE TO PROPERLY IDENTIFY YOUR
BATTERY TYPE, AND SET THE CHARGER
ACCORDINGLY WILL RESULT IN BATTERY
DAMAGE, AND VOID THE WARRANTY.
Your machine may have been ordered with batteries
installed at the NSS factory. The standard battery
type, normally supplied by NSS, is the Flooded (wet)
cell lead acid battery. Gel and AGM sealed batteries
may also be available at customer request.
Flooded (wet) batteries can be easily identified by the
removable cell caps. Removing the caps allows
inspection of the liquid electrolyte (sulfuric acid) level
in each cell.
AGM (Absorbed Glass Mat) batteries are sealed,
maintenance free batteries. They do not have cell
caps intended for removal. Look for “AGM” printed
on the tops or sides of the batteries.
Gel (gelled electrolyte) batteries are also sealed,
maintenance free batteries. They do not have cell
caps intended for removal. Look for “GEL” printed
on the tops or sides of the batteries.
Battery Charger Indicator LED’s
Your battery charger is equipped with LEDs that
indicate the following:
Battery Type Setting. Either of these two LEDs will
be illuminated, anytime the charger is plugged in,
to signal which type(s) of batteries the charger is
configured to charge. The two options available
are:
oWet / AGM: When this LED is illuminated, the
charger is configured to charge either flooded
(wet), or AGM batteries.
oGel Cell. When this LED is illuminated, the
charger is configured to charge Gel batteries
ONLY. EXCEPTION: Crown and Trojan
AGMs are to be charged with the Gel
setting.
State of Charge Indicators. Four additional LEDs
provide information about the charge level of the
batteries during charging.
o30%, 60%, 90% and 100%.
Fault Indications. During charging, the charger
provides feedback about the charge process and
any problems detected. It will provide feedback
and signal the type of problem by flashing LEDs as
described below:
Changing the Battery Type Setting
The standard setting for the onboard battery charger
is Flooded/AGM. EXCEPTION: If your machine was
ordered from NSS equipped with Crown AGM or Gel
batteries, then the charger was configured for Gel
batteries at the factory.
Configuring the Charger for Gel batteries:
1. Remove the top cover.
2. Pull the jumper off the 2-pin connector (position 1),
and then move the jumper to position 2 on only
one pin of the 2-pin connector. See photo below.
3. Reinstall the top cover.
1. The green wire outputs a battery voltage when
the charger is not plugged in to AC to provide an
Interlock function.
2. Securely fasten the black ring terminal from the
charger to the negative terminal ("-", "NEG",
NEGATIVE") of the battery pack.
3. Select Charge Algorithm if battery type is other
than factory default.
Configure the Charger for Flooded/AGM batteries
1. Remove the top cover
2. Pull the jumper from the 2-pin connector, and
install the jumper at position 1 (on both pins of 2-
pin connector).
3. Reinstall the top cover.
Operating the Battery Charger
CAUTION: DIFFERENT BATTERY TYPES HAVE
DIFFERENT CHARGING REQUIREMENTS.
FAILURE TO PROPERLY IDENTIFY YOUR
BATTERY TYPE AND SET THE CHARGER
ACCORDINGLY WILL RESULT IN BATTERY
DAMAGE, AND VOID THE WARRANTY.
The battery charger is fully automatic. Simply plug
the charger into a suitable wall outlet, and the
charger will charge the batteries. The green 100%
LED will be continuously illuminated when the charge
cycle is complete.
A bubbling, or boiling sound coming from the
batteries during the last few hours of the charge is
normal. The batteries may be warm, but not too hot
to touch.
The charger will maintain the proper battery voltage
as long as it is plugged in (maintenance mode).
Equalizing the batteries (Flooded only)
The batteries should be equalized once every 30
days for maximum battery runtime and life.
To equalize the batteries:
Plug in the charger, and fully charge the batteries
(until the green 100% LED is on continuously).
Unplug the charger from the wall outlet, then plug it
back in.
The charger will run for 2hrs, holding the batteries at
a constant voltage, and equalizing each cell.
Opportunity Charging
Opportunity charging is charging the batteries when
an opportunity presents itself, such as during breaks,
and is done in addition to a full charge cycle.
Opportunity charging is recommended, as this extra
charging time will help raise the operating voltage of
the batteries, and will help ensure maximum runtime
and cycle life.
See Operating Battery Charger Instructions or
Monthly Maintenance for equalizing your
batteries especially if you have been opportunity
charging your machine.
Notes on LED indications per DoE compliance:
When first connected to DC (AC not connected), the
LEDs will display one or more of the following:
The LEDs will flash the charger’s ID code (this is for
PCS internal use only). Once the LEDs flash the ID,
they will only display one yellow LED. This
configuration will remain until AC is detected and a
charge cycle is in progress.
There is also a possibility the LEDs will not flash
their ID code and only show a yellow LED.
Lastly, the LEDs may not flash their ID code and
may not show any LEDs until AC is detected.
If the AC line and neutral wires are reversed, the unit
will wait 2 minutes before starting a charge. NOTE:
The 2-minute wait period will also be a factor if the
Top cover
screws
Position 1
For Wet
Cell
(Default)
(Jumper on
both pins)
Position 2
For Gel Cell
(Jumper on 1
Pin of 2-Pin
Connector
)
Jumper
Location
charger is being powered by anything other than
normal grid AC such as a conventional generator,
inverter, etc.
If the AC plug is disconnected during charge, the unit
will turn off as expected. The user may hear some
clicking noise, but should not be alarmed. This is the
Powered by Battery/DOE functionality checking for
AC connection.
How to read charging data from a battery charger
equipped with DeltaView® Link
DeltaView Link
DeltaView Link is a system that allows you to read
data from your battery charger using an app on your
smartphone. The battery charger transmits data to
your phone’s Bluetooth receiver.
These instructions apply to Dual Pro battery chargers
manufactured after 11/29/16. The manufacturing
date is located on the barcode tag attached to the
pigtail cord coming out of the charger. This battery
charger is found on Champ Rider Scrubbers,
Wrangler 3330, Wrangler 2730, Wrangler 2625,
some Wrangler 2016 models, and Charger battery
burnishers.
Instructions
Step 1. Download the Pro Charging Systems “DeltaView
Link” app
For Apple iPhones: Go to the app store and search for
“DeltaView Link” by Pro Charging Systems, LLC.
For Android Phones: Go to the play store and search for
“DeltaView Link” by Pro Charging Systems, LLC.
Step 2. Turn on your phone’s Bluetooth function. If your
Bluetooth is off, the app will turn it on for you when it
starts. Answer “yes” when prompted to turn on
Bluetooth.
Step 3. Locate the “DeltaView Link” icon on your phone
and press it to start the app.
Step 4. A list of all battery chargers that are connected to
AC power within range of your phone will appear. Tap on
a battery charger to select it.
Step 5. Follow the app prompts to read through the data
on your charger. You will find detailed information about
the last 100 charge cycles.
NOTE: Crown and Trojan AGM batteries should
be charged with the GEL setting.
The charger has been tested on batteries from
the following manufacturers:
Trojan flooded cell
US Battery flooded cell
Deka flooded cell
Crown gel
Concord gel
Discover AGM
TROUBLE SHOOTING CHART
Problem Cause Solution
Machine will not turn on.
Battery pack is not plugged into machine.
Open the battery cover and plug the battery
pack into the machine.
Battery charger is plugged into AC outlet. Unplug the battery charger.
The 2-amp fuse is missing or blown. Replace 2-amp fuse.
Circuit breaker is tripped. Reset circuit breaker.
Brush motor will not run
or stopped running.
Current over load of brush motor has exceeded
set parameters in control system.
Turn off all switches and then turn on the
master switch to reset the control system. If the
problem continues check battery meter for fault
code F42.
Tilt switch failure.
Check tilt switch operation. Replace tilt switch if
test failed.
Carbon Brushes worn or not making contact.
Have an authorized NSS Service Station check
carbon brushes and replace if necessary.
Brush motor will not turn
off when handles are in
neutral position.
The potentiometer is set on the threshold of
neutral or potentiometer has failed.
Have an authorized NSS Service Station reset
the potentiometer to neutral or replace.
Machine vibrates.
Pad not centered or torn. Center pad. Change torn and worn pad.
Pad driver damaged and/or out of balance.
Check pad driver for damage and replace if
necessary.
Run time is less than
when new.
Damaged or defective battery or battery pack.
Check for fault codes on the battery charger
during battery charging. Have an authorized
NSS Service Station check the batteries and
replace as necessary.
Batteries are not fully charged
Charge batteries until the green LED indicates
the charge cycle is complete.
Incorrect Battery Type Setting on the charger
Ensure the charger is set according to the type
of batteries installed.
Battery charger will not
turn on.
Battery charger cord damaged.
Check for cord damage and replace if
necessary. DO NOT try to repair it.
Connection not made between battery charger
and battery pack.
Check connections at battery pack for corrosion
and loose or broken wires.
The battery charger is damaged.
Have an authorized NSS Service Station check
and replace if necessary. DO NOT try to repair
it.
TABLE 1
BATTERY TYPES
NSS Part
Number
Crown
Part
Number
Battery Volts
System Volts
Amp Hour
Battery Type
Setting
4491061 1-1470 12 36 215 Flooded/AGM
3390361 1-1435 6
24 &
36
235 Flooded/AGM
2392111 1-1427 12 24 115 SPE CURVE 0
6393651 1-1428 12 24 130 SPE CURVE 0
2392731 1-12145 12 24 100 SPE CURVE 1
6491931 1-1437 6
24 &
36
200 GEL
2691501 1-1450 6 36 350 Flooded/AGM
TROUBLE SHOOTING CHART CONTINUED
Problem Cause Solution
Pad will not stay in the
pad change position.
Weak or missing gas spring(s). Check and replace if necessary.
Pad will turn on in the
pad changing position.
Tilt switch failure.
See daily maintenance for proper checking
procedure. Replace tilt switch as necessary.
Circuit breaker trips.
Spray Buffing. DO NOT spray buff.
Pad pressure to heavy.
Check gas springs for failure and replace as
necessary.
Pad pressure collars out of adjustment.
Readjust pad pressure collars as required by
your burnishing conditions.
Front of machine does
not move down to the
floor when turned on.
Spring guides sticking in slides.
Check spring guides for proper operation.
Replace if bent. Lubricate if necessary. Loosen
bolts in spring guide mounting bracket, it will
self-align, retighten bolts.
Flashing number 1
appears in battery
meter.
Brush motor circuit closed when machine is
turned on.
Turn off brush switch. Check tilt switch for
proper operation.
Flashing letter A
appears in battery
meter.
Twist grip not in neutral when master switch is
turned on. Potentiometer not set properly in
neutral position.
Let go of twist grip. Have an authorized NSS
Service Station reset the potentiometer to
neutral or replace.
Fault code F12 appears
in battery meter.
Internal programmable parameter data is
corrupt.
Turn machine off and then on. If problem
continues call for service.
Fault code F23 appears
in battery meter.
Internal temperature of controller has exceeded
the set parameters.
Turn machine off and let control system cool off.
If problem continues call for service.
Fault code F26 appears
in battery meter.
Precharge failure when controller is turned on or
the control system has been miswired causing
an internal controller failure.
Turn machine off and then on. If problem
continues call for service.
Fault code F29 appears
in battery meter.
Wired incorrectly. Internal control system failure.
Check wiring. Turn machine off and then on. If
problem continues call for service.
Fault code F32 appears
in battery meter.
Wired incorrectly. Internal control system failure.
Check wiring. Turn machine off and then on. If
problem continues call for service.
Fault code F37 appears
in battery meter.
Potentiometer wired incorrectly. Internal control
system failure.
Check wiring. Turn machine off and then on. If
problem continues call for service.
Fault code F42 appears
in battery meter.
The brush motor is exceeding the current limit
set in the controller.
Check the gas springs for wear. Check the
brush pressure set collars for proper
adjustment. Check pad driver and Flexiwall
shield for proper installation and problems. Turn
machine off and then on. If problem continues
call for service.
Fault code
F44/F4C/F45/F59/F60
appears in battery
meter.
Caused by wiring short circuit in drive wiring or
shorted drive motor.
Check wiring and drive motor for short circuit.
Correct problem if found. If problem continues
call authorized NSS Service Station for service.
Fault code F4D/F46/F61
appears in battery
meter.
Caused by wiring short circuit in brush wiring or
shorted brush motor.
Check wiring and brush motor for short circuit.
Correct problem if found. If problem continues
call for service.
Fault code F58 appears
in battery meter.
The deceleration of the brush motor or drive
motor exceeded set parameters. Example:
Tried to slow down or stop on too steep a hill.
Turn machine off and then on. If problem
continues call authorized NSS Service Station
for service.
Fault code F62 appears
in battery meter.
Wired incorrectly. Internal control system failure.
Check wiring. Turn machine off and then on. If
problem continues call for service.
Fault code F63 appears
in battery meter.
Caused by wiring short circuit in contactor
wiring or contactor coil.
Check wiring and contactor for short circuit.
Correct problem if found. If problem continues
call for service.
Repairs performed by an unauthorized company will void the machine warranty.
If
y
ou re
q
uire assistance findin
g
an authorized service center
,
contact NSS Enter
rises.
MANUEL D'UTILISATION
CHARGER 2717 DB & CHARGER 2022 DB
Translation from Original Instructions
Une Traduction Des Instructions Originales
Traducción de las Instrucciones Originales
MANUEL D'UTILISATION
CHARGER 2717 DB & CHARGER 2022 DB
CONSERVER CES INSTRUCTIONS
CONSIGNES DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT: Le non-respect de ces instructions peut causer des
blessures à l'opérateur de la machine ou des passants.
AVERTISSEMENT: Danger
d'incendie ou d'explosion. JAMAIS
utiliser cet appareil dans une
atmosphère explosive (poussière
de grain, liquides ou vapeurs
inflammables, etc.).
AVERTISSEMENT: Danger d'incendie ou
d'explosion.
NE JAMAIS utiliser de liquides
inflammables (gaz, kérosène, de solvants
ou diluants) pour nettoyer ou polir étage.
AVERTISSEMENT: Ce produit contient un produit chimique connu dans l'état de Californie pour
causer le cancer et des malformations congénitales ou autres problèmes de reproduction.
UTILISATION
NSS Polisseuses sont destinés à un usage commercial,
le polissage et le polissage étages dans un
environnement intérieur. Il n'est pas destiné à pulvériser
le brunissage.
NSS Polisseuses sont Twister approuvé.
NSS ne recommande pas l'utilisation de ces machines
à d'autres fins.
POUR LA SÉCURITÉ
TOUJOURS lire et comprendre toutes les instructions
avant d'utiliser ou d'entretenir la machine.
TOUJOURS utiliser cette machine uniquement
comme décrit dans ce manuel.
NE JAMAIS tenter de faire fonctionner cette machine,
sauf si vous avez été formé dans son fonctionnement.
NE JAMAIS laisser une personne non formée à
fonctionner cette machine.
TOUJOURS cette machine à partir du panneau de
commande arrière, pas de côté.
TOUJOURS éteindre l'interrupteur principal lors de la
fixation ou du changement des plaquettes.
NE JAMAIS tenter de faire fonctionner cette machine
si elle ne fonctionne pas correctement ou s'il a été
endommagé de quelque manière.
NE JAMAIS déconnecter ou modifier des
interrupteurs ou des dispositifs de sécurité
(disjoncteur).
NE JAMAIS laisser tomber ou insérer un objet dans
les ouvertures de la machine.
NE JAMAIS utiliser cette machine avec une
ouverture d'air bloqué. Gardez toutes les ouvertures
d'air libres de poussière, les peluches, les cheveux,
etc.
NE JAMAIS ramasser tout ce qui brûle ou qui fume,
comme des cigarettes, des allumettes ou des cendres
chaudes.
NE JAMAIS laissez cette machine pour être utilisé
comme un jouet. Une attention particulière est
nécessaire lorsqu'il est utilisé par ou près des enfants.
TOUJOURS portez des chaussures de tennis propres
ou chaussures "anti-dérapant". Cuir à semelles des
chaussures deviennent extrêmement glissantes.
TOUJOURS garder le visage, les doigts, les cheveux
ou toute autre partie du corps ou des vêtements
amples loin de toute ouverture de la machine ou la
partie mobile (renouvelable pilote de la tablette).
TOUJOURS s'assurer que la rampe est fixée au
véhicule avant de charger / décharger.
TOUJOURS utiliser une extrême prudence lors de
l'utilisation de la machine sur une rampe ou de
chargement / déchargement de cette machine dans ou
hors d'un camion / remorque. Soyez extrêmement
prudent si la rampe est humide, grasse, ou recouverts
de produits chimiques de nettoyage.
NE JAMAIS arrêter ou faire tourner la machine sur
une rampe ou pente.
NE JAMAIS tenter de monter un grade ou d'utiliser
cette machine sur une rampe ou pente de plus de 20
degrés.
TOUJOURS rangez cet appareil à l'intérieur dans un
endroit frais et sec.
NE JAMAIS stationner ou remiser la machine près
d'un quai, sur des rampes, à proximité d'un four, de la
chaudière, de la flamme nue, ou de toute autre source
de chaleur élevée.
NE JAMAIS vaporisez cette machine avec de liquides.
NE JAMAIS laissez la prise de charge de la batterie à
l'humidité ou un court peut se produire.
NE JAMAIS utiliser cette machine lorsque le chargeur
est branché.
NE JAMAIS utiliser la machine à l'extérieur ou laisser
la machine à geler.
NE JAMAIS pas exposer la machine à la pluie, la
neige ou des températures extrêmes.
NE JAMAIS entreposer tous les articles sur la
machine.
TOUT SERVICE de réparation doit être effectuée par un centre DISTRIBUTEUR / SERVICE AUTORISÉ NSS
utilisant uniquement des pièces ÉQUIPEMENT ORIGINAL NSS
CONSIGNES DE SÉCURITÉ IMPORTANTES
ÉQUIPEMENT DE PILES avec à son bord CHARGEURS
AVERTISSEMENT: Le non-respect de ces instructions peut causer des blessures à
l'opérateur de la machine ou les spectateurs.
GENERAL
TOUJOURS lire et comprendre toutes les
instructions avant d'installer ou de charger les
batteries.
NE JAMAIS tenter d'installer ou de charger les
batteries, sauf si vous avez été formé pour le faire.
NE JAMAIS laisser une personne non formée à
installer ou de charger les batteries.
TOUJOURS retirer tous les bijoux lorsque vous
travaillez sur ou près des batteries.
TOUJOURS éteindre tous les commutateurs lors de
l'installation et le service.
TOUJOURS débrancher les câbles de batterie avant
d'effectuer une réparation ou.
TOUJOURS porter des lunettes de protection, des
gants en caoutchouc et des vêtements de protection
pour éviter tout contact avec de l'acide de la batterie.
NE JAMAIS rien poser sur le dessus de piles arc
électrique peut survenir.
SI CONTACT AVEC L'ACIDE piles, suivez ces
instructions:
o PEAU - zone avec de l'eau de rinçage.
o YEUX - Rincer à l'eau pendant 15 minutes.
o INTERNE - Buvez de l'eau ou du lait. Suivez avec
du lait de magnésie, un œuf battu ou de l'huile
végétale. Appeler immédiatement un médecin.
INSTALLATION DES PILES
TOUJOURS utiliser deux personnes pour installer,
que les batteries sont lourdes.
TOUJOURS éteindre tous les interrupteurs de la
machine.
TOUJOURS batteries de position, comme indiqué sur
l'autocollant de l'installation de la machine pour
maintenir l'équilibre de la machine.
TOUJOURS raccorder piles comme indiqué sur un
autocollant à l'installation de la machine pour éviter
de court-circuiter les piles et le système électrique.
CHARGE DE LA BATTERIE
TOUJOURS lire les instructions sur le chargeur
soigneusement.
TOUJOURS utiliser le NSS fourni chargeur avec la
tension nominale correcte.
Pour les batteries au plomb-acide seulement (ne
s'applique pas à la cellule de gel ou batteries sans
entretien).
TOUJOURS vérifier pour assurer le niveau de l'eau
de la batterie couvre les plaques de la batterie avant
de la charger.
TOUJOURS vérifier le niveau d'eau après la charge
et ajouter de l'eau distillée si nécessaire pour amener
le niveau vers le bas de l'orifice
de remplissage.
NE JAMAIS trop remplir les
batteries que la batterie et la
machine peut causer des dommages.
TOUJOURS essuyer un acide à partir du haut des
piles en utilisant une solution de savon.
TOUJOURS rattacher des bouchons de batteries. Ne
chargez pas de bouchons en vrac ou supprimé.
Ajouter que de l'eau distillée.
Pour tous les Types de Batteries
TOUJOURS étudier précautions spécifiques des
fabricants de batteries de tels que les taux
recommandés de la charge.
JAMAIS charger une batterie gelée.
TOUJOURS brancher le chargeur sur une prise de
courant mise à la terre.
NE JAMAIS toucher les parties non isolées du
connecteur de sortie ou les bornes de la batterie non
isolée.
TOUJOURS débrancher l'alimentation secteur avant
de faire ou défaire les connexions à la batterie
pendant la charge.
NE JAMAIS ouvrir ou démonter le chargeur.
NE JAMAIS utiliser le chargeur si le cordon
d'alimentation est endommagé ou si le chargeur a
eçu un coup, s'il est tombé ou endommagé de
quelque manière que.
Lire et comprendre toutes les
instructions avant d'installer ou
de charger les batteries.
Pas de fumée, les flammes,
les étincelles ou en travaillant
avec des piles.
Contient de
l'acide, éviter tout
contact.
Poison. Provoque des
brûlures graves. éviter
tout contact.
AVERTISSEMENT:
Les batteries dégagent de l'hydrogène, ce qui peut provoquer un incendie ou une explosion.
NE JAMAIS fumer, allumer une allumette ou provoquer une étincelle pendant le fonctionnement ou le chargement.
TOUJOURS char
g
er dans un endroit bien ventilé à l'écart de toute flamme.
TOUT SERVICE de réparation doit être effectuée par un centre DISTRIBUTEUR /
SERVICE AUTORISÉ NSS utilisant uniquement des pièces ÉQUIPEMENT ORIGINAL NSS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

NSS Charger 2717DB & Charger 2022DB Manuel utilisateur

Taper
Manuel utilisateur