3
ENGLISH
Support: Support.Eccotemp.com Shop Online: Eccotemp.com Store Locator: Eccotemp.com/locator
PLEASE NOTE: MINI TANKS ARE FOR INDOOR PERMANENT INSTALLATIONS ONLY. BEFORE POWERING THE WATER HEATER, BE SURE THAT THE SYSTEM IS COMPLETELY FILLED WITH WATER
AND ALL AIR IS REMOVED.THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
CAUTION! When a supplemental heat source is connected to the Certied
Household Electric Storage Tank Water Heater, provisions must be made to limit the
heat source temperature not to exceed that of the water heater thermostat setting.
CAUTION! If the water heater has been retrotted with supplemental heating
equipment, you must adjust both the thermostat controlling the supplemental heat
source located in the water piping and the thermostat on the water heater behind
the access panel to the same temperature. Failure to adjust both thermostats to the
same temperature can cause loss of proper temperature control.
CAUTION! To reduce the risk of electric shock or re, use only on a utility supply
having a maximum 125/250 volt, three wire system.
CAUTION! To reduce the risk of electrical shock, connect ground to water heater.
For detailed information refer to instructions.
CAUTION! Install temperature and pressure protective equipment required by
local codes, but no less than a combination temperature and pressure relief valve
certied as meeting the requirements for relief valves, ANSI 21.22, by a nationally
recognized testing laboratory that maintains periodic inspection of production of
listed equipment or materials. The valve must be oriented, provided with tubing, or
otherwise installed so that discharge can exit only within 6 inches above, or at any
distance below, the structural oor, and cannot contact any live electrical part.
DANGER! To reduce the risk of electric shock, disconnect from power supply
before replacing temperature-limiting device.
CAUTION! To reduce the risk of excessive pressures and temperatures in this water
heater, install temperature and pressure protective equipment required by local
codes and no less than a combination temperature and pressure relief valve certied
by a nationally recognized testing laboratory that manintains periodic inspection
of production of listed equipment or materials, as meeting the requirements for
Relief Valves and Automatic Gas Shuto Devices for Hot Water Supply Systems,
ANSIZ21.22. This valve must be marked with a maximum set pressure not to exceed
the marked maximum working pressure of the water heater. Install the valve into
an opening provided and marked for this purpose in the water heater, and orient
it or provide tubing so that any discharge from the valve exits only within 6 inches
above, or at any distance below, the structural oor, and does not contact any live
electrical part. The disharge opening must not be blocked or reduced in size under
any circumstances.
SAFETY