Anolis ArcPixel™ Power Manuel utilisateur

Catégorie
Stroboscopes
Taper
Manuel utilisateur
Version 2.3
QR code for user manual
2
Table of contents
1. Important safety instructions ........................................................................................3
1. Consignes de sécurité importantes..............................................................................4
2. Operating determinations ..............................................................................................5
3. Description of the ArcPixel Power-CE .......................................................................... 6
4. Installation.......................................................................................................................6
4.1. Connection to the mains: .......................................................................................... 6
4.2. Mounting the ArcPixel Power-CE .............................................................................. 7
4.3. Connecting ArcPixes-CE ........................................................................................... 7
4.4. Connecting ArcDots-CE (ArcSource Outdoor 4MC Pixel-CE , ArcDotFlashes-CE) 10
6. Control menu map ........................................................................................................15
5. ArcPixel Power-CE - DMX protocols ........................................................................... 12
7.Control menu .................................................................................................................17
7.1 DMX Addr (Fixture addressing) ............................................................................. 17
7.2 Info (Fixture information) ....................................................................................... 17
7.3 Dots (ArcDot/ArcPix settings) .............................................................................. 17
7.4 Personality ............................................................................................................... 19
7.5 Test ........................................................................................................................... 19
7.6 Stand-alone ............................................................................................................. 20
7.7 Special settings ........................................................................................................ 20
8. Software update............................................................................................................20
9. Incorporation of new dots (after replacing faulty dots) ........................................... 21
10. ArcPixel Power Web manager .................................................................................. 24
11.Technical Specications ............................................................................................. 26
ArcPixel Power-CE
3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
ATTENTION!
Débrancher l’appareil avant d'ouvrir le boîtier!
POUR VOTRE SÉCURITÉ, LISEZ ATTENTIVEMENT CETTE NOTICE AVANT LA PRE-
MIERE UTILISATION
1. Important safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
- follow the instructions and heed all warnings in this manual
CAUTION!
Be careful with your operations. With a high voltage you can suer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
WARNING
To prevent injury, this apparatus must be securely installed in accordance with the
installation instructions.”
Do not block any ventilation openings. Install in accordance with the manufacturers instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
Do not use this apparatus near water. Clean only with dry cloth.
Only use attachments/accessories specied by the manufacturer.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Use a source of AC power that complies with local building and electrical rules. AC power has to have both
overload and short circuit protection.
This device falls under protection class I.Therefore the ArcPixel Power-CE has to be
connected to a mains socket outlet with a protective earthing connection!
This device is for professional use only. It is not for household use.
Warning: Operation of this equipment in a residential environment could cause
radio interference.
The product (covers and cables) must not be exposed to a high frequency electromagnetic eld higher than 3V/m.
Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of
multimedia equipment - Immunity requirements.
4
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia
equipment – Emission Requirements according to class A.
Changes or modications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cau-
se harmful interference in which case the user will be required to correct the interference at his own expense.
1. Consignes de sécurité importantes
Toute personne impliquée dans l'installation et la maintenance de ce produit doit:
- Être susamment qualié
- Suivre les instructions de ce manuel
ATTENTION!
Soyez prudent avec vos manipulations. Avec une haute tension, vous risquez un
choc électrique en touchant les ls à l'intérieur de l'appareil!
Ce produit a quitté nos ateliers dans un état irréprochable. An de maintenir cet état et pour assurer un bon
fonctionnement, il est absolument nécessaire de suivre les consignes de sécurité et les notes contenues dans
ce manuel.
AVERTISSEMENT
Pour éviter toute blessure, cet appareil doit être solidement xé à en conformité
avec les instructions d'installation. "
Ne pas bloquer les ouvertures de ventilation. Installer conformément aux instructions du fabricant.
Ne pas installer près de sources de chaleur telles que radiateurs, ou autres appareils (y compris les ampli-
cateurs) produisant de la chaleur.
Ne pas utiliser cet appareil près de l'eau. Nettoyer avec un chion sec.
Une prise de branchement ou un coupleur est utilisé comme dispositif de déconnexion, ce dispositif doit rester
facilement accessible.
N'utilisez que des accessoires spéciés par le fabricant.
Protégez le cordon d'alimentation du piétinement ou pincement, particulièrement au niveau des ches, des
prises, et le point où ils sortent de l'appareil
Conez toute réparation à un personnel qualié. Une réparation est nécessaire lorsque l'appareil a été endo-
mmagé de quelque façon que ce soit. cordon d'alimentation, che est endommagé, liquide renversé a l interieur,
ou des objets sont tombés dans l'appareil, l'appareil a été exposé à la pluie ou à l'humidité, ne fonctionne pas
normalement , ou s'il est tombé.
Utilisez une source de courant alternatif qui est conforme a l’endroit ou vous vous trouvez. La source alternative
doit avoir à la fois une protection de surcharge et de court-circuit.
Ce dispositif relève de la classe de protection I. Par conséquent, la ArcPixel
Power-CE doit être connecté à une prise électrique reliée à la terre!
5
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched o until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fastened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not qualied
for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!
6
1 - Control board
2 - Power socket
3 - Ethernet
4 - DMX Output
5 - DMX Input
6 - ArcPix output 4
7 - ArcPix output 3
8 - ArcPix output 2
9 - ArcPix output 1
10 - ArcDot output 4
11 - ArcDot output 3
12 - ArcDot output 2
13 - ArcDot output 1
3. Description of the ArcPixel Power-CE
4. Installation
CAUTION!
These servicing instructions are for use by qualied service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that
contained in the operating instructions unless you are qualied to do so.
4.1. Connection to the mains:
The ArcPixel Power-CE is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 Volts. The xture must be grounded.
Connect the xture to the mains with enclosed power cord.
This device falls under protection class I. Therefore the ArcPixel Power-CE has
to be connected to a mains socket outlet with a protective earthing connection.
7
4.2. Mounting the ArcPixel Power-CE
The ArcPixel Power-CE should be be placed on a non-ammable at surface in any orientation and xed by
the four screws.There are four mounting holes of a dimension of 5x7 mm in housing of the driver. Ensure that
installation place is enough ventilated.
4.3. Connecting ArcPixes-CE
1-Screws
2- at surface
3-mounting holes
Connect ArcPixes to the LED outputs of the ArcPixel Power-CE. The rst ArcPix in the ArcPix chain can be
connected to the screw terminal board on the ArcPixel Power-CE either via connection box or via customized
cable length (has to be specied at order). Maximum length between the ArcPixel Power-CE and the last ArcPix
must not exceed 100 metres. For larger installation, the ArcPixel Power-CE should be connected to the Robe
Media Server which allows automatic pixel mapping and full control of the ArcPixes modules.
Placing ferrites
The ferrite CSA19/9.4/29-4S60-EN (P/N 13051312) with one turn of the at cable has to be placed on the
cable at each ArcPix output of the ArcPixel Power-CE, and this ferrite (without cable turn - cable goes directly
through ferrite, ferrite cover is snapped only) has to be placed after each thirtieth ArcPix in the ArcPix line (e.g.
100 ArcPixes per output = 3 ferrites in a line + 1 ferrite with a cable turn at the ArcPix output). You should count
100mm of the cable length per one cable turn on ferrite.
The ArcPix line ferrites (between ArcPixes) have to be placed on the at cable before mounting of ArcPixes on
an installation surface.
8
To connect ArcPixes CE
1. Disconnect ArcPixel Power-CE from mains.
2. Connect ArcPixes (with ferrites as described above) to the ArcPixel Power-CE. Max load per ouput is 100
ArcPixes.
Connect the termination box ArcPix to each ArcPix line. If you use Artnet for control of
the ArcPixel Power-CE, you can connect ArcPixes to all LED outputs 1-4.
For larger installation we recommend to set dierent universes for each ArcPix output. The rst ArcPix has
to have the bottom universe and the last ArcPix the top universe (requirement of the Robe Media Server).
3. Connect ArcPixel Power-CE to mains.
4. Run procedures " Search Dots" and " Sort Dots" from the menu "Dots".
5. Save adjusted values with the option "Store Cong".
7. Connect the ArcPixel Power-CE the Robe Media Server. Set another needed items in
the ArcPixel Power-CE menu.
Note: Never connect/disconnect LED modules when the ArcPixelPower-CE is under voltage!
Every ArcPix line has to be terminated with the termination box ArcPix!
If the line between ArcPixes is disconected, the ArcPixes behind point of interrupt will not work. Before restoring
connection between ArcPixes, switch o the ArcPixel Power-CE.
In case that some ArcPix has been changed, the same address as had original ArcPix is assigned to the new
ArcPix by the ArcPixel Power-CE. It is very important to save Dots conguration at every change of
ArcPixes.(Menu "Dots" -> "Store Cong"),
Max. cable length between the ArcPixel Power-CE and the last connected ArcPix module should not exceed 100m
Note: If DMX is used for control of the ArcPixel Power-CE, the LED outputs 1-3 may be used only.
Number of needed ferrites:
- each ArcPix line: 4 (between
ArcPixes no.30-31, 60-61, 90-91,
at ArcPixel Powe
- total for installation: 16
9
(In this case, one UART from four available UARTs is used for DMX input and remaining three UARTs can be
used for LED outputs only. LED output load is the same as in a case of the control by Artnet - max 100 LED
modules per LED output, but max. 300 modules per xture).
Every ArcPix line has to be terminated with the termination box ArcPix.
The Robe Media Server allows to choose two modes of ArcPixes connection: Fixed-wiring mode and Picture
mode. For detailed description see the user manual of the Robin Media Server.
Number of needed ferrites:
- each ArcPix line: 4 (between
ArcPixes no.30-31, 60-61, 90-91,
at ArcPixel Power-CE)
- total for installation: 12
Three LED outputs
can be used only
10
4.4. Connecting ArcDots-CE (ArcSource Outdoor 4MC Pixel-CE , ArcDotFlashes-CE)
Connect ArcDots to the LED outputs of the ArcPixel Power-CE. The ArcDots can be interconnected directly or
by using T- connectors - see the picture below. If you use Artnet for control of the ArcPixel Power-CE, you can
connect ArcDots to all LED outputs 1-4.
For larger installation (more than 25 ArcDots), the ArcPixel Power-CE should be connected to the Robe Media
Server which allows automatic pixel mapping and full control of the ArcDots modules. Without Robe Media
Server, you have to perform pixel mapping manually using the menu "Dots".
Placing ferrites
The ferrite GTFC 16-8-16 (P/N 1305 1703) has to be placed on the cable at each ArcDot output of the ArcPixel
Power-CE.
To connect ArcDots
1. Disconnect ArcPixel Power-CE from mains.
2. Connect ArcDots (with ferrites as described above) to the ArcPixel Power-CE. Max. number
of ArcDots per output is 35. Connect active terminators to each ArcDots line.
3. Connect the ArcPixel Power-CE to mains
4. Run procedures "Search Dots" and "Sort Dots" from the menu "Dots"
5. Save adjusted values with the option "Store Cong"
6. Disconnect the ArcPixel Power-CE from mains and replace active terminators by passive terminators*.
7. Connect the ArcPixel Power-CE to mains and to the Robe Media Server. Set another needed items in
the ArcPixel Power-CE menu.
* Active terminators can remain permanent connected if there is place for them (they are bigger than passive
ones).
The minimum cable length of 0.3m
between two T-connectors has to
be kept in case that the pixel sor-
ting is executed from the ArcPixel
Power-CE menu.
Every ArcDot line has to
be terminated with the
passive terminator!
Number of needed ferrites:
- at each ArcDot output: 1
- total for installation: 4
Note: Never connect/disconnect LED modules when the ArcPixelPower-CE is under voltage!
If the line between ArcDots is disconected, the ArcDots behind point of interrupt will not work. Before restoring
connection between ArcDots, switch o the ArcPixel Power-CE.
11
In case that some ArcDot has been changed, the same address as had original ArcDot is assigned to it by the
ArcPixel Power-CE. It is very important to save ArcDots conguration at every change of an ArcDot.
(Menu "Dots" -> "Store Cong"),
Max. cable length between ArcPixel Power-CE and the last connected ArcDot module should not be exceeded:
100m @ 25 ArcDots per LED output or 65 m @ 35 ArcDots per LED output.
Only one ArcDot can be connected to the T-connector.
Note: If DMX is used for control of the ArcPixel Power-CE, the LED outputs 1-3 may be used only.
(In this case, one UART from four available UARTs is used for DMX input and remaining three UARTs can be
used for LED outputs only. LED output load is the same as in a case of the control by Artnet - max 35 LED
modules per LED output, max. 100 modules per ArcPixel Power-CE).
Every ArcDot line has to be terminated with the passive terminator!
Note: the same rules as for the ArcDots-CE go for the ArcSource Outdoor 4MC Pixels-CE and Arc-
DotFlashes-CE with the following exception for the ArcDotFlashes-CE: If no DMX signal is present at
ArcPixel Power-CE, the ArcDotFlash modules ash randomly (22-28 ashes per minute).
The Robe Media Server allows you to choose two modes of ArcDots connection: Fixed-wiring mode and Picture
mode. For detailed description see the user manual of the Robin Media Server.
Number of needed ferrites:
- at each ArcDot output: 1
- total for installation: 3
Three LED outputs
can be used only
12
5. ArcPixel Power-CE - DMX protocols
ArcDot-CE/ ArcSource Outdoor 4MC Pixel -CE
version 1.1
RGBW
mode=O
(Channel)
RGBW*
mode=On
(Channel)
Value Function Type of
control
ArcDot 1/ ArcSource Outdoor 4MC Pixel 1
1 1 0-255
Red
Red LED saturation control (0-100%) proportional
2 2 0-255
Green
Green LED saturation control (0-100%) proportional
3 3 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 4 0-255
White
White LED saturation control (0-100%) proportional
ArcDot 2/ ArcSource Outdoor 4MC Pixel 2
4 5 0-255
Red
Red LED saturation control (0-100%) proportional
5 6 0-255
Green
Green LED saturation control (0-100%) proportional
6 7 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 8 0-255
White
White LED saturation control (0-100%) proportional
ArcDot 3/ ArcSource Outdoor 4MC Pixel 3
7 9 0-255
Red
Red LED saturation control (0-100%) proportional
8 10 0-255
Green
Green LED saturation control (0-100%) proportional
911 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 12 0-255
White
White LED saturation control (0-100%) proportional
:
ArcDot 100/ ArcSource Outdoor 4MC Pixel 100
298 397 0-255
Red
Red LED saturation control (0-100%) proportional
299 398 0-255
Green
Green LED saturation control (0-100%) proportional
300 399 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 400 0-255
White
White LED saturation control (0-100%) proportional
:
* RGBW modules only
13
ArcPix-CE
version 1.1
RGBW mode=O
(Channel)
RGBW* mode=On
(Channel) Value Function Type of control
ArcPix 1
1 1 0-255
Red
Red LED saturation control (0-100%) proportional
2 2 0-255
Green
Green LED saturation control (0-100%) proportional
3 3 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 4 0-255
White
White LED saturation control (0-100%) proportional
ArcPix 2
4 5 0-255
Red
Red LED saturation control (0-100%) proportional
5 6 0-255
Green
Green LED saturation control (0-100%) proportional
6 7 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 8 0-255
White
White LED saturation control (0-100%) proportional
ArcPix 3
7 9 0-255
Red
Red LED saturation control (0-100%) proportional
8 10 0-255
Green
Green LED saturation control (0-100%) proportional
911 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 12 0-255
White
White LED saturation control (0-100%) proportional
:
ArcPix 100
298 397 0-255
Red
Red LED saturation control (0-100%) proportional
299 398 0-255
Green
Green LED saturation control (0-100%) proportional
300 399 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 400 0-255
White
White LED saturation control (0-100%) proportional
:
ArcPix 128
352 509 0-255
Red
Red LED saturation control (0-100%) proportional
383 510 0-255
Green
Green LED saturation control (0-100%) proportional
384 511 0-255
Blue
Blue LED saturation control (0-100%) proportional
- 512 0-255
White
White LED saturation control (0-100%) proportional
:
ArcPix 170
508 - 0-255
Red
Red LED saturation control (0-100%) proportional
509 - 0-255
Green
Green LED saturation control (0-100%) proportional
510 - 0-255
Blue
Blue LED saturation control (0-100%) proportional
- - 0-255
White
White LED saturation control (0-100%) proportional
* RGBW modules only
14
ArcDotFlash-CE
version 1.1
Channel Value Function Type of control
ArcDotFlash 1
10-127
128
129-255
Strobe
Synchronous ashing from slow to fast (0.02Hz-20Hz)
Permanent lit
Random ashing from slow to fast (2.2 ashes/minute-28 ashes/minute)
proportional
step
proportional
20-255
Dimmer
Light intensity from 0% to 100% proportional
ArcDotFlash 2
30-127
128
129-255
Strobe
Synchronous ashing from slow to fast (0.02Hz-20Hz)
Permanent lit
Random ashing from slow to fast (2.2 ashes/minute-28 ashes/minute)
proportional
step
proportional
40-255
Dimmer
Light intensity from 0% to 100% proportional
:
ArcDotFlash 100
199 0-127
128
129-255
Strobe
Synchronous ashing from slow to fast (0.02Hz-20Hz)
Permanent lit
Random ashing from slow to fast (2.2 ashes/minute-28 ashes/minute)
proportional
step
proportional
200 0-255
Dimmer
Light intensity from 0% to 100% proportional
15
6. Control menu map
Default settings=Bold print
Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7
DMX Addr Set DMX
Address
0001-0512
IP Address Default Address Set Address
Custom Address IP Adr 1 0-255
IP Adr 2 0-255
IP Adr 3 0-255
IP Adr 4 0-255
Set Address
Network mask Net M. 1
Net M. 2
Net M. 3
Net M. 4
Set Net M.
Info Software Version
IP Addr.
MAC Adr.
Dots New Dots
Unknown Dots
Dots Search Dots
Sort Dots Auto Sort
Manual Sort
Restore Last
Fade Time O
0.1s-25.5s
Dots Curve D. Curve 0-255
RGBW 4ch Mode On, O
Order Mode Order Compact
Order Universe
Store Cong
Test Dots
Update Dots No
Yes
Personality ArtNet Universe Uni. 1 0-255
Uni. 2 0-255
Uni. 3 0-255
Uni. 4 0-255
DMX Input Ethernet
Wired DMX
Display Settings Disp O Timer O, On
Display Lightnes 0-100%
Display Contrast 0-100%
Skip Cfg Mismatch Yes, No
Default Settings Set Defaults
Test Single Dots
All Dots
Full Power
Stand Alone Play On Start O
Single
All
Full PWR
User P1
16
Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7
User P2
User P3
Program Play User 1
User 2
User 3
Program Edit User 1
User 2
User 3 S.Count 1-35
Step 1 Red Z1 0-255
: Green Z1 0-255
Step 35 Blue Z1 0-255
White Z1 0-255
:
Red Z4 0-255
Green Z4 0-255
Blue Z4 0-255
White Z4 0-255
Step Tim. 0-25.5sec
Copy To Next
Special Settings Software Update No, Yes
Reset Password
17
7.Control menu
The control panel situated on the top cover of the ArcPixel Power-CE allows xture addressing and set the
driver´s behaviour.
Control elements:
[ENTER] button- enters menu,conrms adjusted values and leaves menu.
, [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
[ESCAPE] button- leaves the menu without saving value.
7.1 DMX Addr (Fixture addressing)
Set DMX Address - use this menu item to set the DMX start address of the xture, which is dened as the rst
channel from which the ArcPixel Power-CE will respond to the DMX controller.
IP address - select this menu item to set desired IP address. IP address is the Internet protocol
address.The IP uniquely identies any node (xture) on a network. There cannot be 2 xtures with
the same IP address on the network!
Default Address. This address is derived from xture´s MAC address and
cannot be changed. Conrm the item "Set Address" to select this address.
Custom Address. IP address consists of four decimal numbers, each ranging
from 0 to 255, separated by dots, e.g., 172.16.254.1. Each part represents a group of 8 bits
(octet) of the address.
The following items "IP Adr 1", " IP Adr 2", " IP Adr 3", " IP Adr 4" allow to set each
part (number) of the address. After setting desired IP address, conrm the item
"Set Address" to save this address.
Network mask - select this menu item to set desired network mask. A network mask is a 32-bit mask used to
divide an IP address into subnets and specify the networks available hosts.
The following items "Net M.1", "Net.M.2", " Net.M.3", " Net.M.4" serve for seting of each part (number) of
the net mask.
After setting desired network mask, conrm the item "Set Net M." to save adjusted values.
7.2 Info (Fixture information)
Use this menu to read useful information about the xture.
Software version - select this menu item to read software versions.
Dot 10.0/20 - Dot version. The items show software version of each LED module.
MA. In - Driver version. The item shows software version of the ArcPixel Pover-CE.
IP Addr - this menu item shows the current IP address.
MAC Addr - select this menu item to read the MAC address (the MAC address "runs" on display).
Dots - select this menu item to read information about connected LED modules (ArcDot, ArcPix)
New Dots - the item shows the number of recently connected LED modules.
Unknown Dots - the item shows the number of LED modules which were not detected
by the dot checking procedure ("Search Dots") or are new dots after replacement.
18
7.3 Dots (ArcDot/ArcPix settings)
Use this menu to prepare LED module for operation in desired matrix.
Search Dots - this function checks all LED modules connected to the xture and the message “Done” with the
number of found LED modules is displayed after nishing the procedure.
Example: Dots: 25
Search/Done
The ArcPixes, ArcDots are sorted according to their RDM UID in colour range RGB,RGB......RGB.
Sort Dots - this menu allows you to choose automatic or manual sorting of connected LED modules.
Auto Sort - Conected LED modules are sorted automatically by the following rule:
ArcPix modules are sorted according to their IDs.
ArcDot modules are sorted according to their distances from the ArcPixel Power-CE
(the active terminator for the ArcDot has to be connected to the last ArcDot at each LED
output of the ArcPixel Power-CE).
Manual Sort - after choosing this option, the following screen will be displayed:
Example: D001 St1 (D001...LED module No.1, St1.... LED output 1 of the ArcPixel Power-CE )
U1 A001 (U1........universe, A001.......DMX address)
You can go throw connected dots pressing the [UP] and [DOWN] buttons, current displayed
LED module starts blinking a white colour.
Press the [ENTER], item U1 starts to blink slowly. Now by means of the [UP] and [DOWN]
buttons you can move between the item A001 and U1. To edit celected item, press
the [ENTER] again, selected item will start to blink fast and you can set desired values
using the UP] and [DOWN] button.
After automatic or manual sorting, do not forget to save changes by means of
the menu item „Store Cong“.
Restore Last - recalls last saved dots conguration.
Fade Time - select this menu item to set a desired max. fade time (0-25.5 sec.). This adjusted fade time inu-
ences fade of RGB and dimmer during DMX operation:
If time between two receiving DMX values is > than fade time set in the item "Fade Time", the entire adjusted
fade time will be used.
If time between two receiving DMX values is < than fade time set in the item "Fade Time", the adjusted fade
time will be reduced to ll entire time between the two receiving DMX values.
e.g. "Fade Time".=2sec. and xture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It
means, that red will go to full intensity during 2 seconds.
"Fade Time"=8 sec. and xture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It
means, that red will go to full intensity during 5 seconds. (Max, fade time is reduced from 8 sec. to 5 sec.).
Dots Curve - this menu item allows you to select desired running of colour saturation. You can select 255
colour saturation runnings in all. The value 0 corresponds linear curve, the value 128 corresponds exponential
curve with index 1.9 and last value 255 corresponds exponential curve with index 2.6.
RGBW 4ch Mode - This function activates four channels RGBW mode (see DMX protocol) - for RGBW
modules only.
19
Order Mode - the menu allows to select a method how LED modules will be assigned to the Artnet Universe.
Order Compact - All LED modules will be assigned to the Universe at the rst LED output. After lling
this Universe, the rest of LED modules will be assigned to the Universe at the LED output 2.
Order Universe - LED modules output will be assigned to dierent Universes. LED modules on the
rst LED output to the Universe set at this LED output. LED modules on the second LED output to the Universe
set at the second LED output etc.
Store Cong - select this function to save all changes that have been done in the menu "Dots" .
Test Dots - use this menu item to browse throw the list of sorted LED modules.The ID of corresponding dot is
shown under the dot number. Displayed LED module blinks in white.
Update Dots - allows update of the connected LED modules after standard software updating of the ArcPixel
Power-CE (item “Software Update” in the menu "Special Setting").
Note: The update via the menu "Software Update" has to be realized before running the "Update Dots"
procedure
7.4 Personality
Use this menu to modify the ArcPixel Power-CE operating behavior.
ArtNet Universe - use the menu item to assign ArtNet universe to desired LED output.
Uni.1 - ArtNet universe for LED output 1
:
Uni.4 - ArtNet universe for LED output 4
ArtNet is a proprietary protocol for transmitting DMX512 (with RDM) over UDP/IP. Up to sixteen DMX512
universes can be accessed through one IP subnet.
The Universe is a single DMX 512 frame
of 512 channels.
DMX Input - this menu allows you to choose desired DMX data input:
Artnet - if this input is selected (RJ45), all LED outputs (1-4) are active.
Wired DMX - if this input is selected (3-pin XLR), only LED outputs 1-3 are active.
Display Settings - this menu allows you to change the display settings.
Display O Timer - if this item is on the display will be swiched o 2 minutes after last pressing any
button on the control panel.
Display Lightness - select this menu item to adjust the display intensity (0-100%).
Display Contrast- select this menu item to adjust contrast of the display (0-100%).
Skip Cfg Mismatch - If this function regards behaviour of the xture if some dots have been replaced (e.g.
due to faulty dots).
No: after switching the xture on, the channel with the new dots will be displayed and dots check
procedure will stop.You have to manually assigned new dots.
Yes: after switching the xture on, the dots checking procedure will run and error messages
regards replaced dots will apear (in case that some problem occured). Fixture menu is accessible.
Default setting - select this option to set xture personalities to the default (factory) values.
7.5 Test
Single Dots - the LED modules blink one by one starting from DMX address 1 (universe 1) in the colour order
red, green, blue and white.
All Dots - all connected LED modules blink together in the colour order red, green, blue and white.
Before both test sequences, the "Search Dots" and "Sort Dots" procedures from the menu "Dots" have tu be
made.
Full Power - all connected LED modules light at max light output (R+G+B+W=full).
20
7.6 Stand-alone
The ArcPixel Power is not connected to the Robe Media Server but can execute pre-set programs (sequences).
Play On Start - This function allows you to select a program which will be played after switching the xture on.
Selected program will be played continuously in a loop.
O - function is disabled.
Single - LED modules blink one by one in the colour order red, green, blue and white.
All - all connected LED modules blink together in the colour order red, green, blue and white.
Full PWR - all connected LED modules light at max light output (R+G+B+W=full).
User P1 - the ArcPixel Power plays user program 1.
User P2 - the ArcPixel Power plays user program 2.
User P3 - the ArcPixel Power plays user program 3.
Program Play - entering this menu provides a complete overview of all programs oered, from which
the selected program can run continuously in a loop .
User 1 - the ArcPixel Power plays user program 1.
User 2 - the ArcPixel Power plays user program 2.
User 3 - the ArcPixel Power plays user program 3.
Program Edit - the ArcPixel Power oers three freely editable programs each up 35 steps. Every program step
includes a step time-the total time occupied by the step in the program.
To edit a program
1. Use the [UP] and [DOWN] buttons to select desired program (User 1-User 3) and press the [ENTER] button.
2. Enter the item S. Count and by means of the [UP] and [DOWN] buttons set desired number of program steps.
This value should be set before starting of programming (e.g. if you want to create a program with 10 steps,
set S. Count=10).
3 Press the [ENTER] button.
4.Select Step 1 and press the [ENTER] button. List of editable items will appear:
Red Z1 - a red LEDs on LED output 1
Green Z1 - a green LEDs on LED output 1
Blue Z1 - a blue LEDs on LED output 1
White Z1 - a white LEDs on LED output 1
:
Red Z4 - a red LEDs on LED output 4
Green Z4 - a green LEDs on LED output 4
Blue Z4 - a blue LEDs on LED output 4
White Z4 - a white LEDs on LED output 4
Step Tim. - a step time (0-25.5 sec)
Copy To Next - this item duplicates the current prog. step to the next prog. step.
5. After editing the items, select next prog. step and edit its items again. Repeat this action for all program steps.
7.7 Special settings
Reset Password
- using this function you can reset current password into default password: admin.
8. Software update
The Ethernet input (RJ45) also serves for software update of the xture by means of the ROBE RDM
Uploader software.
For more details about the ROBE RDM Uploader, please visit https://www.robe.cz/robe-uploader/.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Anolis ArcPixel™ Power Manuel utilisateur

Catégorie
Stroboscopes
Taper
Manuel utilisateur

dans d''autres langues