Bosch B308 Guide d'installation

Catégorie
Protection contre le feu
Taper
Guide d'installation
1 | Overview
2 | SDI2 address settings
The module’s switches provide a tens and ones value for the
module’s address. For single-digit address numbers 1 through
9, set the tens switch to 0 and the ones digit to the appropriate
number. The following illustration shows the address switches
setting for addresses 1 and 11.
Set the switches per the control panel configuration. Each
B308 module must have a unique address.
3.1 | Install the module in the enclosure
Refer to the following illustration for installing into the enclo-
sure.
3.2 | Install and wire the tamper switch
You can connect an optional enclosure door tamper switch
for one module in an enclosure.
1. Put the ICP-EZTS Tamper Switch (P/N: F01U009269)
into the enclosure’s tamper switch mounting location.
For complete instructions, refer to EZTS Cover and Wall
Tamper Switch Installation Guide (P/N: F01U003734).
2. Plug the tamper switch wire onto the module’s tamper
switch connector.
3.3 | Attach to the control panel
Use either the module’s terminal strip labeled with PWR, A, B,
and COM, or the module’s interconnect wiring connectors (wire
included) to attach to the control panel. Interconnect wiring
parallels the PWR, A, B, and COM terminals on the terminal
strip.
Refer to the following illustrations for wiring.
NOTICE!
Use the terminal strip wiring or interconnect wiring
connector to the control panel. Do not use both. When
connecting multiple modules, combine terminal strip
and interconnect wiring connectors in series.
3 | Installation
Callout ― Description
1 ― Module with mounting bracket installed
2 ― Enclosure
3 ― Mounting screws (3)
Callout ― Description
1 ― Terminal strip wiring (SDI2)
2 ― Interconnect cable (P/N: F01U079745) (included)
Callout ― Description
1 ― Bosch control panel
2 ― B308 modules
Callout ― Description
1 ― Bosch control panel
2 ― B308 modules
CAUTION!
Remove all power (AC and battery) before making any
connections. Failure to do so might result in personal
injury and/or equipment damage.
NOTICE!
The module reads the switch setting only during
power up. Cycle the power to the module to enable
the new setting.
= Outputs 11 to 18
= Outputs 111 to 118
2.1 | Valid addresses and output numbers per
control panel
Valid B308 addresses are dependent on the number of outputs
allowed by a particular control panel.
Control
panel
Valid B308
addresses
Corresponding output
numbers
B9512G 01 - 59 11 - 18, 21 - 28, 31 - 38, 41 -
48, 51 - 58, 61 - 68, 71 - 78,
81 - 88, 91 - 98, 101 - 108,
111 - 118, 121 - 128, 131 -
138, 141 - 148, 151 - 158,
161 - 168, 171 - 178, 181
- 188, 191 - 198, 201 - 208,
211 - 218, 221 - 228,
231 - 238, 241 - 248, 251 -
258, 261 - 268, 271 - 278,
281 - 288, 291 - 298, 301
- 308, 311 - 318, 321 - 328,
331 - 338, 341 - 348, 351 -
358, 361 - 368, 371 - 378,
381 - 388, 391 - 398, 401
- 408, 411 - 418, 421 - 428,
431 - 438, 441 - 448, 451 -
458, 461 - 468, 471 - 478,
481 - 488, 491 - 498, 501
- 508, 511 - 518, 521 - 528,
531 - 538, 541 - 548, 551 -
558, 561 - 568, 571 - 578,
581 - 588, 591 - 598
B8512G 01 - 09 11 - 18, 21 - 28, 31 - 38, 41 -
48, 51 - 58, 61 - 68, 71 - 78,
81 - 88, 91 - 98
B6512 01 - 09 11 - 18, 21 - 28, 31 - 38, 41 -
48, 51 - 58, 61 - 68, 71 - 78,
81 - 88, 91 - 96
B5512 01 - 05 11 - 18, 21 - 28, 31 - 38,
41 - 48, 51 - 58
B4512 01 - 03 11 - 18, 21 - 28, 31 - 38
D9412GV4 01 - 12 11 - 18, 21 - 28, 31 - 38,
41 - 48, 51 - 58, 61 - 68,
71 - 78, 81 - 88, 91 - 98,
101 - 108, 111 - 118,
121 - 128
D7412GV4 01 - 06 11 - 18, 21 - 28, 31 - 38,
41 - 48, 51 - 58, 61 - 64
D7212GV4 01 - 02 11 - 18, 21 - 24
To find the output numbers for each address, multiply the
address number by 10 for the base number, and then use
numbers 1 through 8 in the ones place for the output numbers.
For examples, refer to Section 8.
This module is a supervised device that provides 8
programmable outputs (Form C relays) and connects to control
panels through the SDI2 bus.
Callout ― Description
1 ― SDI2 interconnect connectors - connect SDI2 control
panel and SDI2 devices
2 ― SDI2 terminal strip - connect SDI2 control panel and
SDI2 devices
3 ― Tamper switch connector
4 ― Terminal strip (outputs)
5 ― Heartbeat LED (blue)
6 ― Address switches
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
© 2018 Bosch Security Systems, Inc. F.01U.265.458 | 06 | 2018.05
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
Copyright
This document is the intellectual property of Bosch Security
Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and must be
treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to
the Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
8 | Point number examples
El-gr: Μεταβείτε στη διεύθυνση https://gr.boschsecurity.com/el/ για την
τεκμηρίωση σε αυτήν τη γλώσσα.
Es-es: Visite https://es.boschsecurity.com/es/ para obtener documentación en
este idioma.
Fr-fr: Accédez à l’adresse https://fr.boschsecurity.com/fr/ pour obtenir la
documentation dans cette langue.
Hu-hu: A honosított dokumentációt lásd a https://hu.boschsecurity.com/hu/
oldalon.
It-it: Andare a https://it.boschsecurity.com/it/ per la documentazione in questa
lingua.
Pl-pl: Dokumentacja w tym języku znajduje się w witrynie https://
pl.boschsecurity.com/pl/
Pt-br: Acesse http://pt.boschsecurity.com/pt/ para obter a documentação neste
idioma.
7 | Specifications
Dimensions 2.9 in x 5.0 in x 0.6 in
(73.5 mm x 127 mm x 15.25 mm)
Voltage
(operating)
12 V nominal
Current
(maximum)
150 mA (22 mA for digital section + 16 mA
per energized relay)
Operating
temperature
+32°F to +122°F (0°C to +50°C)
Relative
humidity
5% to 93% at +90°C (+32°C) non-
condensing
Relay
outputs
Dry contacts rated for .001 to 1.0 A at 5 to
24 VDC (resistive load).
Terminal wire
size
12 AWG to 22 AWG (2 mm to 0.65 mm)
SDI2 wiring Maximum distance - Wire size (Unshielded
wire only):
400 ft (122 m) - 22 AWG (0.65 mm)
1000 ft (305 m) - 18 AWG (1.02 mm)
Compatibility B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512/B5512E
B4512/B4512E
D9412GV4/D7412GV4/D7212GV4
(Refer to the control panel installation
document for number of supported
devices.)
6 | Certifications
Region
US UL 365 - Police Station Connected Burglar Alarm
Units and Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 864 - Control Units and Accessories for Fire
Alarm Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System
Units
UL 1076 - Proprietary Burglar Alarm Units and
Systems
UL 1610 - Central-Station Burglar-Alarm Units
CSFM - California Office of The State Fire
Marshal
FCC Part 15 Class B
FDNY - Fire Department of New York
FM Approval 3010
Canada CAN/ULC-S303 Local Burglar Alarm Units and
Systems
CAN/ULC-S304 Central and Monitoring Station
Burglar Alarm Units
ICES-003 - Information Technology Equipment
(ITE)
ULC/ORD-C1023 Household Burglar Alarm Sys-
tem Units
ULC/ORD-C1076 Proprietary Burglar Alarm
Units and Systems
When the tamper switch is on, the heartbeat LED stays OFF
for 3 second before showing the firmware version. The LED
flashes the major, minor, and micro digits of the firmware
version, with a 1 second pause after each digit.
For example, the version 1.4.3 shows as LED flashes:
[3 second pause] *___****___*** [3 second pause, then
normal operation].
With a tamper switch:
1. Open the enclosure door.
2. Push and release the switch
5 | Show the firmware version
Without a tamper switch:
1. Quickly short the tamper pins.
2. Refer to the illustration below.
4 | LED descriptions
The module includes one heartbeat LED to indicate that
the module has power and to indicate the module’s current
state. Refer to the following table.
Flash Pattern Function
Flashes once
every 1 second
Normal operation state.
3 quick flashes
every 1 second
Communication error state: Indicates an
SDI2 communication error.
ON Steady LED trouble state: Not powered (for
OFF Steady only), or some other trouble
condition.
OFF Steady
3.4 | Relay output wiring
Each output provides a NO and a NC output. The NO, C
(COMMON), and NC terminals are available in each terminal
or connection output position. The silkscreen on the edge
of the circuit board shows the function of each terminal and
the relay output number.
The middle terminal of each output position is the
COMMON and is labeled C. When the output is inactive,
the NC (Normally Closed) terminal has continuity with the
C terminal. When the output is active (energized), the NO
(Normally Opened) has continuity with the C terminal.
NOTICE!
Do not exceed relay contact ratings of 1.0 A, 24
VDC, resistive load.
For B308 address 01 the output numbers for the output devices
are 11 through 18:
Terminal no 1 2 3 4 5 6 7 8
Output no 11 12 13 14 15 16 17 18
For B308 address 11 the output numbers for the output devices
are 111 through 118:
Terminal no 1 2 3 4 5 6 7 8
Output no 111 112 113 114 115 116 117 118
en Installation Guide
Octo-output Module
B308
  • Page 1 1
  • Page 2 2

Bosch B308 Guide d'installation

Catégorie
Protection contre le feu
Taper
Guide d'installation

dans d''autres langues