Astria Fireplaces EBVPF Instruction Sheet

Catégorie
Cheminées
Taper
Instruction Sheet
1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
In Canada
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1
AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDA-
TIONS DES AUTORITÉS PROVINCIALES
AYANT JURIDICTION ET CONFORMÉMENT
AUX EXIGENCES DU CODE D'INSTALLATION
CAN1-B149.1 ET.2.
GAS APPLIANCE
KITS AND ACCESSORIES
GAS CONVERSION KIT (FGCK)
WARNING: THIS CONVERSION KIT SHALL BE IN-
STALLED BY A QUALIFIED SERVICE AGENCY IN ACCOR-
DANCE WITH THE MANUFACTURER'S INSTRUCTIONS
AND ALL APPLICABLE CODES AND REQUIREMENTS
OF THE AUTHORIZED AGENCY HAVING JURISDICTION.
IF THE INFORMATION IN THESE INSTRUCTIONS ARE
NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR
PRODUCTION OF CARBON MONOXIDE MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE. THE INSTALLATION IS NOT PROPER
AND COMPLETE UNTIL THE OPERATION OF THE CON-
VERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE
OWNER INSTRUCTIONS SUPPLIED WITH THE KIT.
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA
INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CON-
FORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES
EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉS AVOIR
LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUC-
TION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION
OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RÉ-
SULTER LE DOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU
BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE
DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE
DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE
ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CON-
VERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS
LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES
AVEC L'ÉQUIPEMENT.
750018M REV. F 03/2015
Note: For detailed information on derating at
altitudes above 2,000 feet, please refer to the
"Orifice Sizes - Sea Level To High Altitude (All
Models)" section of the appliance Installation
Instructions.
To complete the conversion proceed as follows:
Note: After converting the valve and gas
components, refer to the appliance Installation
Instructions and Care and Operation Instruc-
tions to adjust the air shutter opening for the
gas type used.
CAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, before
proceeding with the conversion.
Step 1. Turn off the gas supply to the appli-
ance. Remove the front glass door/frame (if
used) from the appliance. Access the control
compartment.
Step 2. Carefully remove the logs. Exercise
care as not to break the logs.
Step 3. Locate the screws securing the burner
(tray) to the appliance. Remove the burner and
retain the securing screws.
This Gas Conversion Kit contains all of the
necessary components needed to complete
the conversion of an appliance from the use of
one type of gas to the use of another, including
labeling that must be affixed to ensure safe
operation.
ALWAYS REFER TO THE APPLIANCE INSTAL-
LATION AND HOMEOWNERS CARE AND
OPERATION DOCUMENTS BEFORE COM-
PLETING A CONVERSION. ALL WARNINGS,
CAUTIONS AND DETAILED INSTRUCTIONS
CONTAINED THEREIN ARE APPLICABLE TO
THIS DOCUMENT.
evlaVtlovilli
M.
oNtraP/eziS
ecifirOrenruB ecnailppAoTrefeR
launaMnoitallatsnI
ecifirOtoliP ecnailppAoTrefeR
launaMnoitallatsnI
daeHevla
Vt
iKhtiWdedivorP
sleba
Lt
iKhtiWdedivorP
evlaVcinortcel
E.
oNtraP/eziS
ecifirOrenruB ecnailppAoTrefeR
launaMnoitallatsnI
ecifirOtoliP ecnailppAoTrefeR
launaMnoitallatsnI
wercSgnitsujd
At
iKhtiWdedivorP
paCdettol
St
iKhtiWdedivorP
gnirp
St
iKhtiWdedivorP
sleba
Lt
iKhtiWdedivorP
Kit Components:
P750018M
2NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Electronic Appliances
Step 7. Honeywell Electronic Valves - See
Figure 7. Remove the slotted cap screw, o-ring,
pressure-regulating adjusting screw and spring.
Retain all parts for possible later use. Install
new components from this kit. Black cap and
red spring for propane gas units. Silver cap and
stainless steel spring fro natural gas units.
Figure 6
Figure 3
Pilot
Orifice
Figure 2
Flip Cap
Thread
Protector
HONEYWELL
VALVE
Figure 4
Step 6. Refer to Figure 3 and remove the
pilot hood assembly to access the hexed pilot
orifice. Using a (4mm) Allen wrench, remove
and replace the orifice with the one provided
with this kit. Figure 4 shows the pilot reas-
sembled, with proper flame. Figure 5 shows
a typical pilot to burner relationship.
Pilot
Burner
Figure 5
(Millivolt Example Shown)
Figure 1
Pressure
Regulator
Remove
These
Components
SIT VALVE
Step 5. Honeywell Systems - See Figure
2. Remove the black thread-protecting cap.
Remove the conversion flip cap by turning it
counterclockwise. Invert the flip cap so that the
letters associated with the desired gas type are
positioned closest to the valve body.
NG is for natural gas and LP is for propane.
Tighten the flip cap by turning it clockwise.
Replace the black thread-protecting cap.
Millivolt Appliances
Step 4. SIT Systems - Refer to Figure 1. Using
a Torx T20, or a flat screwdriver, remove and
discard the three pressure regulator mounting
screws. Remove the pressure regulator, spring,
poppet, diaphragm and bushing.
Discard all removed components. Ensure
the rubber gasket installed on the back of the
replacement pressure regulator is properly
positioned and install the new pressure regula-
tor using the new screws supplied with this kit.
Tighten screws to 25 In. lb. torque.
3/8” Min
(9 mm)
Hood
Pilot
Nozzels
Ignitor Rod
Note: If the ignitor assembly is damaged, a replacement kit is available, order Catalog Number 87L54.
Retaining
Clip
Ignitor
Assembly
Pilot
Assembly
Pilot
Orifice
Flare Nut
INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACE • CONVERSION KITS
3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 7
Spring
Adjusting
Screw
Slotted
Cap
PSI
OFF
I
ON
CONTROL
IGNITE
Test
Port
Step 8. Refer to Figure 6 and replace the pilot
orifice as follows: Remove the ignitor assembly
retainer clip, and carefully remove the ignitor
assembly. Exercise extreme care to prevent
damage to or breakage of the ignitor assembly.
Remove the screw securing the pilot assembly
to its mounting bracket. Back off the flare nut
at the end of the pilot gas line to free the pilot
assembly from the gas line.
Remove the pilot orifice and replace it with
the one provided with this conversion kit.
Reinstall the pilot assembly by reversing the
steps detailed here.
When reinstalling the ignitor assembly, use
extreme care to prevent damage and break-
age. Do not apply any leverage to the ignitor
assembly while restoring the retainer clip to
its original position.
Figure 8
ALL FIXED SETTING SIT VALVES
Millivolt Appliances
Step 9. SIT Systems - Refer to Figure 1. Using
a Torx T20, or a flat screwdriver, remove and
discard the three pressure regulator mounting
screws. Remove the pressure regulator, spring,
poppet, diaphragm and bushing.
Discard all removed components. Ensure
the rubber gasket installed on the back of the
replacement pressure regulator is properly
positioned and install the new pressure regula-
tor using the new screws supplied with this kit.
Tighten screws to 25 In. lb. torque.
Step 10. Refer to Figure 3 and remove the
pilot hood assembly to access the hexed pilot
orifice. Using a (4mm) Allen wrench, remove
and replace the orifice with the one provided
with this kit. Figure 4 shows the pilot reas-
sembled, with proper flame. Figure 5 shows
a typical pilot to burner relationship.
Step 12. Refer to Figure 6 and replace the pilot
orifice as follows: Remove the ignitor assembly
retainer clip, and carefully remove the ignitor
assembly. Exercise extreme care to prevent
damage to or breakage of the ignitor assembly.
Remove the screw securing the pilot assembly
to its mounting bracket. Back off the flare nut
at the end of the pilot gas line to free the pilot
assembly from the gas line.
Remove the pilot orifice and replace it with
the one provided with this conversion kit.
Reinstall the pilot assembly by reversing the
steps detailed here.
When reinstalling the ignitor assembly, use
extreme care to prevent damage and break-
age. Do not apply any leverage to the ignitor
assembly while restoring the retainer clip to
its original position.
Figure 9
All Models
Step 13. Unscrew the orifice from the manifold
and replace it with the one provided with this
kit (Figure 9 ).
Step 14. Reassemble all removed components
by reversing the procedures outlined in the
preceding steps. Use pipe joint compound or
Teflon tape on all pipe fittings before installing
(ensure propane resistant compounds are used
in propane applications, do not use pipe joint
compounds on flare fittings). Adjust the air
shutter opening on the burner tube, refer to
Note on page 1.
Step 15. Attach appropriate conversion kit
label (Figure 10 ) next to the rating plate on
the appliance. Attach the installer conversion
label next to the gas valve, after filling out the
information on the label. Refer to the Installation
Instructions for required input rating.
Figure 10
Step 18. For detailed Lighting Instructions, refer
to the Care And Operations instructions.
Step 16. Turn on gas supply and test for gas
leaks, using a gas leak test solution (also referred
to as bubble leak solution).
Step 17. Attach manometer to the manifold
side pressure test fitting (1/4" Allen wrench for
Electric units) and adjust screw until pressure
reads 3.5 inches water column (6.54 MmHg)
for natural gas, and 10.0 inches water column
(18.69 MmHg) for propane gas. Refer to the
Installation Instructions and the Table below.
Modified Kit
Pressure Regulator
- After Trim
Remove
These
Components
SIT VALVE
Kit Pressure
Regulator - Before
Trim
Electronic Appliances
Step 11. SIT Systems - See Figure 8. Using
a Torx T20, or a flat screwdriver, remove and
discard the three pressure regulator mounting
screws. Remove the pressure regulator, spring,
poppet, diaphragm and bushing. Discard all
removed components.
Using a standard tin snip cutting tool, proceed
to trim shoulder off of the regulator provided
with the kit. Ensure the rubber gasket installed
on the back of the replacement pressure regula-
tor is properly positioned and install the new
modified pressure regulator using the new
screws supplied with this kit. Tighten screws
to 25 In. lb. torque.
Inlet Gas Supply Pressure
Fuel # Minimum Maximum
Propane
Natural
(2.74 kPa)
11.0" WC 13.0" WC
(3.23 kPa)
(1.24 kPa)
4.5" WC 10.5" WC
(2.61 kPa)
INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACE • CONVERSION KITS
4NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Printed in U.S.A.
© 2015 INNOVATIVE HEARTH
PRODUCTS, LLC
P/N 750018M Rev. F 03/2015
P750018M
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE
AND ARE NOT DRAWN TO SCALE. 1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
IHP.us.com
INNOVATIVE HEARTH PRODUCTS • DIRECT-VENT GAS FIREPLACE • CONVERSION KITS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Astria Fireplaces EBVPF Instruction Sheet

Catégorie
Cheminées
Taper
Instruction Sheet

dans d''autres langues