HITACHI
HA-6800
CHECKING THE OPERATION OF THE PROTECTION
CIRCUIT
When the
output
·circuit
is
repaired by replacing the
power
transistors, etc., perform an operation check on
the
ASO (Area
of
Safe Operation) detection circuit and
the speaker protection circuit.
1.
Operation
check
of
the
ASO
detection
circuit
for
the
output
transistors
Connect the audio oscillator
to
the TUNER
IN
ter-
minals
with
the speaker terminals unloaded (speaker:
disconnect).
Set the frequency
of
the audio oscillator
at
1 kHz and adjust the level
of
the input signal so
that
the voltage
at
the speaker terminals
is
approx. 5
V rms.
Under these conditions, short-circuit the speaker ter-
minals of the channel to
which
the input signal
is
ap-
plied using a
lead
wire, etc. If this sl:lort-circuit makes
the
ASO detection circuit operate, no
output
appears
at
the speaker terminals even if the
lead
wire used
for
short-circuiting
is
removed.
Next, turn
off
the
power
switch
and, after approx.
10
sec., turn the power
switch
on again. When
output
comes
out
of the speaker terminals, this indicates
that
the ASO detection circuit
is
operating normally.
2.
Operation
check
of
the
speaker
protection
cir-
cuit
Make sure that the relay operates
(a
click sound
is
heard) approx.
6-10
seconds after the power switch
is
turned on
with
the speaker terminals unloaded
(speaker: disconnect).
Next, when a resistor
with
a resistance of approx-
imately
10
k ohms and
two
1.5 V dry batteries
are
connected
in
series across pins 4 and 2
of
main
power printed wiring board
IC901, the relay turns
off
within 1 sec. When the dry batteries are taken away,
the relay operates again. Next, change the polarities
of
the dry batteries and carry
out
the abovemention-
ed
operation to check the operation of the relay.
If
the relay
is
energized
with
this operation,
it
means
that the speaker protection circuits are functioning
normally.
When conducting this operational check, take care
not
to create shortcircuits
with
parts close
at
hand.
3.
Operation
check
of
temperature-detection
cir-
cuit
Leave the speakers disconnected
without
a load, set
the power switch
to
ON
and check that a clicking
sound
is
heard by the relay being energized after a
period of 6 to
10
seconds.
Next, warm up the
SR901
body using a soldering iron
or a hair dryer.
Once the temperature
of
the body
reaches about
100°C, the protection circuit
is
ac-
tivated and the
relay
is
turned OFF.
Even
if the body
is
no longer warmed up, the relay
is
not reset. Next,
set the power switch to
OFF and after allowing the
body
to
cool
down
sufficiently, switch
ON
the power
again. If the relay
is
energized, it means that the
temperature-detection protection circuit
is
operating
normally.
CAUTION
Before warming up the body, detach the clamp and
distance the
SR901
from the radiation fin. When a
soldering iron
of
the
30
watts class
is
used and the body
is
warmed up too much, the devices themselves may
be
damaged. Take care not to apply heat for a long period
of
time.
Method
of
checking
the
POWER
MOS
FET---...
Remove the
FET.
In the
case
of
an
N channel
FET,
it
is
normal: When
touching the black test probe of the tester (ohm
range
X100)
to the drain of the
FET,
and the
red
test
probe to the source, after applying the black test pro-
be
to the gate
and
the
red
test probe to the source at
the same time, a current flows. And next, when
brushing both the gate
and
source simultaneously
with
your hand, the current stops.
In
the case of a P channel, the
red
and black test pro-
bes
of
the tester
are
applied
in
reverse.
Audio
oscillator
Frequenzgenerator
Oscillateur
ci'onde
sonore
-12-
AC
voltmeter
Wechselstrom
Voltmeter
Voltmetre
a
Courant
alternatif
SR901
Oscilloscope
Oszillograph
Oscilloscope
Fig. 1
Abb.
7
Fig.
8
Abb.
8
Fig. 9
Abb.
9
•
Phenomena
and
remedy
when
the
protection
circuit
operates
Type
of
protection circuit
Phenomenon when the protection
Cause
Remedy
circuit operates
1
Muting
circuit
No sound comes
out
about
6-10
Normal
sec. after the
power
switch
is
turned ON.
2
Protection circuit
of
the
1.
No sound comes out.
Short
circuit
of
speaker
Turn
off
the
power
switch, check
POWER MOS
FET
(ASO
2.
When the power switch is
output
terminal.
whether the speaker terminal
is
short
protection circuit)
turned
ON, the relay becomes
circuited or not, and turn
ON
again.
ON, then
OFF
when the signal
is
applied.
3 Speaker protection circuit
1. No sound comes out.
Power amplifier faulty,
1.
Repair faulty parts
in
power
(DC voltage detec-
2.
Neutral point voltage
is
more
etc.
amplifier.
.tion/protection
circuit)
than
±2
V.
3.
After
the power switch
is
turned ON, relay doesn't turn
ON.
4 Temperature-detection pro-
1 . Sound suddenly stops
when
1. Poor heat
1.
Improve heat dissipating effect.
tection circuit used for a long time.
dissipating effect.
2.
Use speakers
with
an
impedance
2.
Speaker impedance
of
not
less than 6 ohms or avoid
is
too low.
use
at
sound volume levels.
KONTROllE
DER FUNKTION DER
SCHUTZSCHAl
TUNG
Falls die Ausgangsschaltung repariert wurde, indem
z.b. die Leistungstransistoren usw. erneuert wurden,
dann
mur5
die ASO-Schutzschaltung (ASO = Area
of
Safe Operation) und die Lautsprecher-Schutzschaltung
kontroliert werden.
1.
Funktionsprufung
der
ASO-Schaltung
fur
die
leistu
n
gstra
nsisto
ren
Den Frequenzoszillator
an
die TUNER
IN
anschlier5en, wobei die Lautsprecherklemmen keine
Last aufweisen durfen (Lautsprecher nicht
angeschlossenl. Die Frequenz des Frequen-
zoszillators
auf
1 kHz einstellen und den
Pegel
des
Eingangssignales so abgleichen,
dar5
die Spannung
an
den Lautsprecherklemmen etwa 5 V (Mittelwert,
bewertet) betragt.
In
diesem Zustand sind die Laut-
sprecherklemmen
kurzzuschlier5en, und zwar die
Klemmen jenes Kanals,
an
welchen
das
Eingangssignal angelegt wurde.
Falls
dieser Kurz-
schlur5
zu
einem Ansprechen der ASO-
Schutzschaltung fUhrt,
dann erscheint kein
Ausgangssignal
an
den Lautsprecherklemmen, auch
nicht wenn den zum
Kurzschlier5en der Klemmen
verwendete Draht
entfernt
wird.
Danach den
Netzschalter abschalten und nach etwa
10
Sekunden wieder einschalten. Wenn nun ein
Ausgangssignal
an
den Lautsprecherklemmen
festgestellt wird bedeutet dies,
dar5
die ASO-
Schutzschaltung
richtig arbeitet.
2.
Funktionsprufung
der
lautsprecher-
Schutzschaltung
Darauf achten,
dar5
etwa
6-10
Sekunden nach dem
Einschalten
des
Netzschalters ein Schaltgerausch
des Relais vernommen werden kann, wenn keine
Last
an
den Lautsprecherklemmen anliegt
( Lautsprecher nicht angeschlossen).
Wenn ein Widerstand mit einem Widerstand von
ea.
10
kOhm und zwei 1,5 V Trockenbatterien
in
Serie
-13-
mit
Stift
4 und
Stift
2 von
IC901
der gedruckten
Schaltung parallelgeschaltet werden, wonach das
Relais innerhalb einer Sekunde abschalten sollte.
Werden die Trockenbatterien wieder entfernt, dann
arbeitet das
Relais wiederum. Anschlier5end die
Polaritat der Tockenbatterien umpolen und die obige
Prufung des Relais nochmals durchfUhren. Wenn
auch nun das
Relais
aktiviert wird, dann ist die
Lautsprecher-Schutzschaltung
in
Ordnung.
Bei
dieser PrOfung ist besonders darauf
zu
achten,
dar5
keine der benachbarten Teile kurzgeschlossen
werden.
Wird das
Relais
dadurch erregt, bedeutet es,
dar5
die
Schutzschaltkreise der Lautsprecher normal funk-
tionieren.
Wenn diese Funktionsprufung vorgenommen wird,
darauf achten,
dar5
keine Kurzschlusse mit
naheliegenden Teilen entstehen.
3.
Funktionsprufung
des
Warmeentdeckungs-
Schaltkreises
Die Lautsprecher ohne Belastung getrennt lassen,
den Netzschalter einschalten und uberprufen,
dar5
nach 6 bis
10
Sekunden durch Erregen
des
Relais
ein
Knackgerausch gehart wird.
Danach den
Karper
des
S
R-901
mit einem Lotkolben
oder Haartrockner anwarmen. Wenn die Temperatur
des Korpers
ea.
100°C erreicht, wird der Schutz-
schaltkreis aktiviert und das Relais ausgeschaltet.
Selbst wenn der Karper nicht weiter erwarmt wird,
erfolgt keine Ruckstellung des
Relais. Als nachstes
den Netzschalter ausschalten, und nachdem sich der
Karper genugend abgekuhlt hat, das Gerat wieder
einschalten. Wird das Relais erregt, bedeutet
es,
daf?:.
der Warmeentdeckungs-Schutzschaltkreis normal
funktioniert.