DeWalt DW079KDT Le manuel du propriétaire

Taper
Le manuel du propriétaire
DW079
Rotary Laser
Laser rotatif
Láser rotativo
INSTRUCTION MANUAL
GUIDE D'UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA
DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DEWALT • www.dewalt.com
English
1
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS
OR ANY DEWALT TOOL, CALL US TOLL FREE AT:
1-800-4-DEWALT (1-800-433-9258).
WARNING! Read and understand all instructions.
Failure to follow all instructions listed below may result
in electric shock, fire and/or serious personal injury.
SAVE THESE INSTRUCTIONS
Safety Instructions for Lasers
Do not operate the laser in explosive atmospheres, such as
in the presence of flammable liquids, gases, or dust. Power
tools create sparks which may ignite the dust or fumes.
Use the laser only with the specifically designated batteries.
Use of any other batteries may create a risk of fire.
Store idle laser out of reach of children and other untrained
persons. Lasers are dangerous in the hands of untrained
users.
Use only accessories that are recommended by the
manufacturer for your model. Accessories that may be suitable
for one laser, may create a risk of injury when used on another
laser.
Tool service MUST be performed only by qualified repair
personnel. Repairs, service or maintenance performed
by unqualified personnel may result in injury. To locate
your nearest DEWALT service center call 1-800-4-DEWALT
(1-800-433-9258) or go to http://www.dewalt.com on the Internet.
Do not use optical tools such as a telescope or transit to
view the laser beam. Serious eye injury could result.
Do not place the laser in a position which may cause anyone
to intentionally or unintentionally stare into the laser beam.
Serious eye injury could result.
Do not position the laser near a reflective surface which
may reflect the laser beam toward anyone’s eyes. Serious
eye injury could result.
Turn the laser off when it is not in use. Leaving the laser on
increases the risk of staring into the laser beam.
Do not operate the laser around children or allow children
to operate the laser. Serious eye injury may result.
Do not remove or deface warning labels. If labels are
removed user or others may inadvertently expose themselves to
radiation.
Position the laser securely on a level surface. Damage to the
laser or serious injury could result if the laser falls.
Dress properly. Do not wear loose clothing or jewelry.
Contain long hair. Keep your hair, clothing, and gloves away
from moving parts. Loose clothing, jewelry, or long hair can be
caught in moving parts. Air vents often cover moving parts and
should also be avoided.
WARNING: Use of controls or adjustments or performance
of procedures other than those specified herein may result in
hazardous radiation exposure.
WARNING! DO NOT DISASSEMBLE THE ROTARY LASER.
There are no user serviceable parts inside. Disassembling
the rotary laser will void all warranties on the product. Do not
modify the product in any way. Modifying the tool may result in
hazardous laser radiation exposure.
The label on your tool may include the following symbols.
V .......volts nm .....wavelength in nanometers
mW .....milliwatts IIIa ..... Class IIIa Laser
.....laser warning symbol
English
2
FIG. 1 For your convenience and safety, the following labels are on your
laser (Fig. 1).
AVOID EXPOSURE: LASER RADIATION IS EMITTED FROM
THIS APERTURES.
DANGER: LASER RADIATION. AVOID DIRECT EYE
EXPOSURE.
Laser Information
The DW079 Cordless Rotary Laser is listed as a CLASS IIIA LASER
PRODUCT and complies with the applicable requirement of title 21
of the Code of Federal Regulations set forth by: the Department of
Health, Education, and Welfare; the Food and Drug Administration;
the Center for Devices and Radiological Health.
These devices comply with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio and television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
English
3
Connect the equipment into an outlet on a circuit differentfrom
that which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
These Class B digital devices comply with Canadian ICES-003.
SPECIFICATIONS
Light Source Semiconductor laser diode
Laser Wavelength 630 – 680 nm Visible
Laser Power <5mw, CLASS IIIa LASER
PRODUCT
Rotation Speed 0 – 600 rpm
Self-Leveling Range ± 5°
Indoor Visible Range 200' (61 m) diameter
Range with Detector 1500' (450 m) diameter
Level Accuracy ± 1/8" per 100' (± 3 mm per 31 m)
Power Source 9.6V–18V DEWALT batteries
Operating Temperature 23°F to 122°F (-5°C to 50°C)
Storage Temperature -4°F to 158°F (-20°C to 70°C)
Environmental Water resistant
Important Safety Instructions for All
Battery Packs
When ordering replacement battery packs, be sure to include
catalog number and voltage. Consult the chart at the end of this
manual for compatibility of chargers and battery packs.
The battery pack is not fully charged out of the carton. Before using
the battery pack and charger, read the safety instructions below.
Then follow charging procedures outlined.
READ ALL INSTRUCTIONS
Do not charge or use battery in explosive atmospheres,
such as in the presence of flammable liquids, gases or dust.
Inserting or removing the battery from the charger may ignite the
dust or fumes.
NEVER force battery pack into charger. DO NOT modify
battery pack in any way to fit into a non-compatible charger
as battery pack may rupture causing serious personal injury.
Consult the chart at the end of this manual for compatibility of
batteries and chargers.
Charge the battery packs only in DEWALT chargers.
DO NOT splash or immerse in water or other liquids.
Do not store or use the tool and battery pack in locations
where the temperature may reach or exceed 105°F (40˚)
(such as outside sheds or metal buildings in summer).
DANGER: Electrocution hazard. Never attempt to open the
battery pack for any reason. If battery pack case is cracked or
damaged, do not insert into charger. Do not crush, drop or damage
battery pack. Do not use a battery pack or charger that has
received a sharp blow, been dropped, run over or damaged in
any way (i.e., pierced with a nail, hit with a hammer, stepped on).
Electric shock or electrocution may result. Damaged battery packs
should be returned to service center for recycling.
NOTE: Battery storage and carrying caps are provided
for use whenever the battery is out of the tool or
charger. Remove cap before placing battery in charger
or tool.
WARNING: Fire hazard. Do not store or carry
battery so that metal objects can contact exposed
battery terminals. For example, do not place battery in aprons,
pockets, tool boxes, product kit boxes, drawers, etc., with loose nails,
screws, keys, etc. without battery cap. Transporting batteries can
possibly cause fires if the battery terminals inadvertently come
in contact with conductive materials such as keys, coins, hand
tools and the like. The US Department of Transportation Hazardous
English
4
Material Regulations (HMR) actually prohibit transporting batteries
in commerce or on airplanes (i.e., packed in suitcases and carry-on
luggage) UNLESS they are properly protected from short circuits.
So when transporting individual batteries, make sure that the
battery terminals are protected and well insulated from materials
that could contact them and cause a short circuit.
SPECIFIC SAFETY INSTRUCTIONS FOR NICKEL CADMIUM
(NiCd) OR NICKEL METAL HYDRIDE (NiMH)
Do not incinerate the battery pack even if it is severely
damaged or is completely worn out. The battery pack can
explode in a fire.
A small leakage of liquid from the battery pack cells may
occur under extreme usage or temperature conditions. This
does not indicate a failure.
However, if the outer seal is broken:
a. and the battery liquid gets on your skin, immediately wash
with soap and water for several minutes.
b. and the battery liquid gets into your eyes, flush them
with clean water for a minimum of 10 minutes and seek
immediate medical attention. (Medical note: The liquid is
25-35% solution of potassium hydroxide.)
SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM ION (LI-ION)
Do not incinerate the battery pack even if it is severely
damaged or is completely worn out. The battery pack can
explode in a fire. Toxic fumes and materials are created when
lithium ion battery packs are burned.
If battery contents come into contact with the skin,
immediately wash area with mild soap and water. If battery
liquid gets into the eye, rinse water over the open eye for
15 minutes or until irritation ceases. If medical attention is
needed, the battery electrolyte is composed of a mixture of liquid
organic carbonates and lithium salts.
Contents of opened battery cells may cause respiratory
irritation. Provide fresh air. If symptoms persists, seek medical
attention.
WARNING: Burn hazard. Battery liquid may be flammable if
exposed to spark or flame.
The RBRC™ Seal
The RBRC™ (Rechargeable Battery Recycling
Corp oration) Seal on the nickel cadmium, nickel metal
hydride or lithium ion batteries (or battery packs)
indicate that the costs to recycle these batteries (or
battery packs) at the end of their useful life have
already been paid by DEWALT. In some areas, it is
illegal to place spent nickel cadmium, nickel metal hydride or lithium
ion batteries in the trash or municipal solid waste stream and the
RBRC program provides an environmentally conscious alternative.
RBRC™ in cooperation with DEWALT and other battery users,
has established programs in the United States and Canada to
facilitate the collection of spent nickel cadmium, nickel metal
hydride or lithium ion batteries. Help protect our environment and
conserve natural resources by returning the spent nickel cadmium
and nickel cadmium, nickel metal hydride or lithium ion batteries
to an authorized DEWALT service center or to your local retailer
for recycling. You may also contact your local recycling center for
information on where to drop off the spent battery.
RBRC™ is a registered trademark of the Rechargeable Battery
Recycling Corporation.
Important Safety Instructions for All
Battery Chargers
SAVE THESE INSTRUCTIONS: This manual contains important
safety and operating instruc tions for battery chargers.
English
5
Before using charger, read all instructions and cautionary
markings on charger, battery pack, and product using battery
pack.
DANGER: Electrocution hazard. 120 volts are present at
charging terminals. Do not probe with conductive objects. Electric
shock or electrocution may result.
WARNING: Shock hazard. Do not allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Burn hazard. To reduce the risk of injury, charge only
DEWALT rechargeable batteries. Other types of batteries may
burst causing personal injury and damage.
CAUTION: Under certain conditions, with the charger plugged
in to the power supply, the exposed charging contacts inside the
charger can be shorted by foreign material. Foreign materials of a
conductive nature such as, but not limited to, steel wool, aluminum
foil, or any buildup of metallic particles should be kept away from
charger cavities. Always unplug the charger from the power supply
when there is no battery pack in the cavity. Unplug charger before
attempting to clean.
DO NOT attempt to charge the battery pack with any
chargers other than the ones in this manual. The charger and
battery pack are specifically designed to work together.
These chargers are not intended for any uses other than
charging DEWALT rechargeable batteries. Any other uses
may result in risk of fire, electric shock or electrocution.
Do not expose charger to rain or snow.
Pull by plug rather than cord when disconnecting charger.
This will reduce risk of damage to electric plug and cord.
Make sure that cord is located so that it will not be stepped
on, tripped over, or otherwise subjected to damage or
stress.
Do not use an extension cord unless it is absolutely
necessary. Use of improper extension cord could result in risk
of fire, electric shock, or electrocution.
When operating a power tool outdoors, use an extension
cord suitable for outdoor use. Use of a cord suitable for out-
door use reduces the risk of electric shock.
An extension cord must have adequate wire size (AWG
or American Wire Gauge) for safety. The smaller the gauge
number of the wire, the greater the capacity of the cable, that
is 16 gauge has more capacity than 18 gauge. An undersized
cord will cause a drop in line voltage resulting in loss of power
and overheating. When using more than one extension to make
up the total length, be sure each individual extension contains
at least the minimum wire size. The following table shows the
correct size to use depending on cord length and nameplate
ampere rating. If in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.
Recommended Minimum Wire Size for Extension Cords
Total Length of Cord
25 ft. 50 ft. 75 ft. 100 ft. 125 ft. 150 ft. 175 ft.
7.6 m 15.2 m 22.9 m 30.5 m 38.1 m 45.7 m 53.3 m
Wire Size AWG
18 18 16 16 14 14 12
Do not place any object on top of charger or place the
charger on a soft surface that might block the ventilation
slots and result in excessive internal heat. Place the charger
in a position away from any heat source. The charger is ventilated
through slots in the top and the bottom of the housing.
Do not operate charger with damaged cord or plug.
English
6
Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to an
authorized service center.
Do not disassemble charger; take it to an authorized
service center when service or repair is required. Incorrect
reassembly may result in a risk of electric shock, electrocution
or fire.
Disconnect the charger from the outlet before attempting
any cleaning. This will reduce the risk of electric shock.
Removing the battery pack will not reduce this risk.
NEVER attempt to connect 2 chargers together.
The charger is designed to operate on standard 120V
household electrical power. Do not attempt to use it on any
other voltage. This does not apply to the vehicular charger.
Using Automatic Tune-Up™ Mode
The Automatic Tune-Up™ Mode equalizes or balances the
individual cells in the battery pack allowing it to function at
peak capacity. Battery packs should be tuned up weekly or after
10 charge/discharge cycles or whenever the pack no longer
delivers the same amount of work. To use the Automatic Tune-
Up™, place the battery pack in the charger and leave it for at least
8 hours. The charger will cycle through the following modes.
1. The red light will blink continuously indicating that the 1-hour
charge cycle has started.
2. When the 1-hour charge cycle is complete, the light will stay
on continuously and will no longer blink. This indicates that the
pack is fully charged and can be used at this time.
3. If the pack is left in the charger after the initial 1-hour charge,
the charger will begin the Automatic Tune-Up™ mode. This
mode continues up to 8 hours or until the individual cells in the
battery pack are equalized. The battery pack is ready for use
and can be removed at any time during the Automatic Tune-
Up™ mode.
4. Once the Automatic Tune Up™ mode is complete, the charger
will begin a maintenance charge; the red indicator will remain
lit.
Chargers
Your tool uses a DEWALT 9.6, 12, 14.4, 18 Volt charger. Be sure to
read all safety instructions before using your charger. Consult the
chart at the end of this manual for compatibility of chargers and
battery packs.
Charging Procedure
DANGER: Electrocution hazard. 120 volts present at charging
terminals. Do not probe with conductive objects. Danger of electric
shock or electrocution.
1. Plug the charger into an appropriate outlet before inserting
battery pack.
2. Insert the battery pack into the charger, making sure the pack
is fully seated. The red (charging) light will blink continuously
indicating that the charging process has started.
3. The completion of charge will be indicated by the red light
remaining ON continuously. The pack is fully charged and may
be used at this time or left in the charger.
Indicator Light Operation
English
7
Charge Indicators
Some chargers are designed to detect certain problems that can
arise with battery packs. Problems are indicated by the red light
flashing at a fast rate. If this occurs, re-insert battery pack into
the charger. If the problem persists, try a different battery pack to
determine if the charger is OK. If the new pack charges correctly,
then the original pack is defective and should be returned to a
service center or other collection site for recycling. If the new battery
pack elicits the same trouble indication as the original, have the
charger tested at an authorized service center.
HOT/COLD PACK DELAY
Some chargers have a Hot/Cold Pack Delay feature: when the
charger detects a battery that is hot, it automatically starts a Hot
Pack Delay, suspending charging until the battery has cooled. After
the battery has cooled, the charger automatically switches to the
Pack Charging mode. This feature ensures maximum battery life.
The red light flashes long, then short while in the Hot Pack Delay
mode.
PROBLEM POWER LINE
Some chargers have a Problem Power Line indicator. When the
charger is used with some portable power sources such as
generators or sources that convert DC to AC, the charger may
temporarily suspend operation, flashing the red light with two
fast blinks followed by a pause. This indicates the power source
is out of limits.
LEAVING THE BATTERY PACK IN THE CHARGER
The charger and battery pack can be left connected with the red
light glowing indefinitely. The charger will keep the battery pack
fresh and fully charged.
NOTE: A battery pack will slowly lose its charge when kept out of
the charger. If the battery pack has not been kept on maintenance
charge, it may need to be recharged before use. A battery pack may
also slowly lose its charge if left in a charger that is not plugged into
an appropriate AC source.
WEAK BATTERY PACKS: Chargers can also detect a weak
battery pack. Such batteries are still usable but should not be
expected to perform as much work. The charger will indicate to
replace battery pack.
Important Charging Notes
1. Longest life and best performance can be obtained if the battery
pack is charged when the air temperature is between 65°F and
75°F (18° - 24°C). DO NOT charge the battery pack in an air
temperature below +40°F (+4.5°C), or above +105°F (+40.5°C).
This is important and will prevent serious damage to the battery
pack.
2. The charger and battery pack may become warm to touch while
charging. This is a normal condition, and does not indicate a
problem. To facilitate the cooling of the battery pack after use,
avoid placing the charger or battery pack in a warm environment
such as in a metal shed, or an uninsulated trailer.
3. If the battery pack does not charge properly:
a. Check current at receptacle by plugging in a lamp or other
appliance
b. Check to see if receptacle is connected to a light switch
which turns power off when you turn out the lights.
c. Move charger and battery pack to a location where the
surrounding air temperature is approximately 65°F - 75°F
(18°- 24°C).
d. If charging problems persist, take the tool, battery pack and
charger to your local service center.
4. The battery pack should be recharged when it fails to produce
sufficient power on jobs which were easily done previously.
DO NOT CONTINUE to use under these conditions. Follow
English
8
the charging procedure. You may also charge a partially used
pack whenever you desire with no adverse affect on the battery
pack.
5. Under certain conditions, with the charger plugged into the
power supply, the exposed charging contacts inside the charger
can be shorted by foreign material. Foreign materials of a
conductive nature such as, but not limited to, steel wool,
aluminum foil, or any buildup of metallic particles should be kept
away from charger cavities. Always unplug the charger from the
power supply when there is no battery pack in the cavity. Unplug
charger before attempting to clean.
6. Do not freeze or immerse charger in water or any other liquid.
WARNING: Shock hazard. Don’t allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Never attempt to open the battery pack for any
reason. If the plastic housing of the battery pack breaks or cracks,
return to a service center for recycling.
Storage Recommendations
1. The best storage place is one that is cool and dry away from
direct sunlight and excess heat or cold.
2. Long storage will not harm the battery pack or charger. Under
proper conditions, they can be stored for 5 years or more.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
LASER OPERATION
To extend battery life per charge, turn the laser off when it is not
in use.
To ensure the accuracy of your work, check the laser
calibration often. Refer to Field Calibration Check under
Laser Maintenance.
Before attempting to use the laser, make sure the tool is
positioned on a relatively smooth, secure surface.
• Always mark the center of the laser line or dot. If you mark
different parts of the beam at different times you will introduce
error into your measurements.
To increase working distance and accuracy, set up the laser in
the middle of your working area.
When attaching to a tripod or wall, mount the laser securely.
When working indoors, a slow rotary head speed will produce
a visibly brighter line, a faster rotary head speed will produce a
visibly solid line.
To increase beam visibility, wear Laser Enhancement Glass es
and/or use a Laser Target Card to help find the beam.
Extreme temperature changes can cause movement or shifting
of building structures, metal tripods, equipment, etc., which can
effect accuracy. Check your accuracy often while working.
When working with the DEWALT Digital Laser Detector, set the
laser’s rotation speed to the fastest setting.
If the laser is dropped or has suffers a sharp blow, have the
calibration system checked by a qualified service center before
using the laser.
A
C
B
FIG. 2
English
9
Installing and Removing the
Battery Pack (Fig. 2)
NOTE: Make sure your battery pack is fully charged before you
install it.
INSTALLING THE BATTERY PACK
1. Release latch (B) to open the hatch door (A). Insert the battery
pack (C).
CAUTION: The laser will operate even if battery door is not
fully latched. To secure the battery, always ensure battery door
is closed and latched.
2. Slide the battery pack in firmly.
3. Close the hatch door and fasten latch.
REMOVING THE BATTERY PACK
1. Release latch to open the hatch door.
2. Remove the battery pack.
3. To recharge the battery pack, insert it into the charger as
described in the charger section of this manual.
Laser Control Panel
The laser is controlled by the power button (D), the speed/rotation
button (E), the scan mode button (F), and two arrows (G, H). The
arrows control the movement of the laser head left and right when
the laser is being used in the plumb mode. Four LED indicator lights
are on the control panel: power (I), X-axis leveling (J), Y-axis leveling
(K) and remote control private mode (L).
TURNING THE LASER ON (FIG. 3)
1. Insert the fully charged battery pack. Be sure that the battery
door is securely latched.
2. Gently press the power button (D) to power the laser on. The
power LED indicator light (J) will illuminate. If the laser is out of
level, the X-axis (J) and/or Y-axis (K) leveling lights will flash until
the laser is level. Press the speed/rotation button (E) to adjust
the rotation speed.
NOTE: The head will begin or resume rotation once the laser is
level.
KJ
I
H
G
F
E
DL
FIG. 3
TURNING THE LASER OFF
Gently press the power button to turn the laser off. The power LED
indicator light will no longer be illuminated.
Laser Control Panel Buttons
POWER BUTTON
To completely power the laser unit off, the power button on the
control panel of the laser unit must be pressed. The laser unit will
also automatically power off if it is left in Sleep Mode for 8 hours.
NOTE: Press the remote control power button to put the laser unit
into Sleep Mode. In Sleep Mode all laser unit functions shut off
except for a periodic blink from the power LED on the control panel
of the laser unit. Press the remote control power button again to
“wake up” the laser unit.
English
10
ARROW BUTTONS
The arrow buttons (G, H) are used for different functions depending
on the operating mode of the laser unit.
In Self-Leveling Horizontal Mode:
The arrows buttons adjust the direction of the laser beam in
Scan Mode or Pointing Mode (0 rpm).
In Self-Leveling Vertical Mode:
The arrow buttons move the laser beam left and right.
In Manual Mode:
The arrow buttons are used to tilt the laser head.
NOTE: Refer to Using the Wireless Remote Control for a full
description of Manual Mode.
SPEED/ROTATION BUTTON
The speed/rotation button (E) is used to adjust the rotation speed
of the laser beam through its 4 preset speeds.
The head speed will cycle through 4 speeds, then repeat the
sequence as the speed/rotation button is pressed.
REMEMBER:
Slow speed = Bright Beam Fast Speed = Solid Beam
NOTE: The speed/rotation button performs the same function as
the speed/rotation button on the remote control.
SCAN MODE BUTTON
The scan mode button (F) is used to make the laser head sweep
back and forth, creating a short, bright laser line. This short line is
much brighter and more visible than when the unit is in full rotation
mode.
Using Scan Mode:
To enter Scan Mode, push and release the scan mode
button. To exit Scan Mode, push and release the button
again.
The size and direction of the scan zone can be controlled
with the arrow buttons on the laser unit control panel or the
remote control. For a more detailed explanation, refer to
Using the Wireless Remote Control.
The size and direction of the scan zone can also be controlled
manually with the User Defined Scan Mode:
1. Set the laser unit at 0 rpm (pointer mode).
2. Manually rotate the laser head to position the laser beam
at one edge of the desired scan zone.
3. Press and hold the scan mode button on the laser unit
control panel. While holding down the scan mode button,
manually rotate the laser head to the opposite edge of the
desired scan zone.
4. Release the scan mode button.
5. The laser will scan between the two selected points.
NOTE: If the scan mode button is pressed and held, but the
laser head is not manually rotated, after four seconds the unit
will enter Private Mode or No Remote Mode as described
below.
IMPORTANT: The remote control cannot be used for User
Defined Scan Mode.
PUBLIC, PRIVATE AND NO REMOTE MODES
The DW079 Rotary Laser and the DW0794 Remote Control each
have the capability to operate in either Public Mode or Private
Mode. For the laser and the remote control to work together, they
must both be set to the same mode. The laser unit can also be set
to No Remote Mode, which causes it to ignore all remote control
commands.
Public Mode
The laser unit can receive commands from any DEWALT
laser remote control, and even from some other brands of
English
11
laser remote controls. This is the normal, default operating
mode for the DW079 laser unit.
To Activate Public Mode:
Press and hold the speed/rotation button (E) (open
padlock symbol beside the button).
As the default operating mode, the laser unit will power
up in Public Mode if:
The laser was last used in Public Mode
OR
The laser has been turned off for 8 hours after being
used in Private Mode
OR
The battery pack has been removed and reinstalled.
Private Mode
The laser unit will only accept commands from the
DW0794 remote control designated by the user.
To activate Private Mode:
Press and hold the scan mode button (F) on the laser
unit control panel (closed padlock symbol) and at the
same time press and hold the remote control scan
mode button (R) (closed padlock symbol).
After 4 seconds, both the laser unit and the remote
control will enter Private Mode. As confirmation,
the laser unit will beep and the laser control panel
LED (L) (next to the closed padlock symbol) and the
remote control LED (T) (next to the closed padlock
symbol) will flash.
No Remote Mode
This mode causes the laser unit to ignore all remote
control commands.
To activate No Remote Mode:
Press and hold the scan mode button (F) on the laser
unit control panel (closed padlock symbol), but do
not press any button on the remote control.
After 4 seconds, the laser unit will beep and the LED
(L) next to the padlock symbol will flash.
Using the Wireless FIG. 4 S
M
P
O
N
RQ
T
Remote Control (Fig. 4)
The remote control allows one person
to operate and setup the laser from a
distance. The remote control features a
power button (M), manual mode button
(N), four arrows (O, PP), speed/rotation
button (Q) and scan mode button (R).
Two LED indicator lights are on the
remote control: transmit (S) and private
mode (T).
REMOTE CONTROL: POWER
BUTTON
Press the remote control power button
(M) to put the laser unit into Sleep
Mode. In Sleep Mode all laser unit functions shut off except for a
periodic blink from the power LED (L) on the control panel of the
laser unit. Press the remote control power button again to “wake
up” the laser unit.
NOTE: To completely power the laser unit off, the power button on
the control panel of the laser unit must be pressed. The laser unit will
also automatically power off if it is left in Sleep Mode for 8 hours.
REMOTE CONTROL: MANUAL MODE BUTTON
To activate Manual Mode, press and hold the remote control manual
mode button (N) for 3 seconds. Manual Mode must be activated to
English
12
use manual sloping. (Refer to Using Manual Slope Mode for a
complete description of this function.)
To re-engage full self-leveling, press and hold the manual mode
button again for 3 seconds.
Using Manual Slope Mode:
The DW079 Manual Slope Mode allows the self-leveling
function to be disabled in one axis (direction) so that the
laser can be sloped in that axis. The other axis will continue
to self-level, ensuring that the laser beam is only sloping in
the expected direction.
Entering and exiting Manual Slope Mode:
To activate Manual Slope Mode, press and hold the
remote control manual mode button (N) for 3 seconds.
To re-engage full self-leveling, press and hold the
manual mode button again for 3 seconds.
Setting the Slope Direction:
When Manual Slope Mode is activated, the unit auto-
matically engages Manual Y Mode. This allows the
operator to slope the laser in the direction of the Y-axis,
as indicated by the “gunsights” on the rollcage.
In certain situations, it may be desirable to slope the
laser in the X-axis. The direction of Manual Slope Mode
can be changed back and forth between the Y- and
X-axes as follows:
Immediately (within 5 seconds) after entering Manual
Slope Mode, press and hold the remote control right
arrow button to activate Manual X Mode.
The unit can be changed back to Manual Y Mode by
immediately pressing and holding the remote control
left arrow button.
To change the direction of Manual Slope Mode at a
later time, re-engage full self-leveling, then activate
Manual Slope Mode again and go through the axis
selection procedure outlined above.
The X and Y LED indicator lights on the laser unit control
panel (Fig. 3, K, J) will indicate the manual slope direction
that is selected. The manually controlled axis is identified
by a turned-off LED, and the self-leveling axis is identified
by a lighted LED.
Setting the Amount of Slope:
Once Manual Slope Mode is activated, the amount of
slope can be manually adjusted using any of the following
methods:
Use the laser control panel up and down arrow buttons
(Fig. 3, G, H) to tilt the laser rotor head up and down.
OR
Use the remote control up and down arrow buttons
(Fig. 3, O) to tilt the laser rotor head up and down.
OR
The entire laser unit can be tipped up and down by
setting it on a sloped surface. Make sure the laser unit is
positioned so the direction of manual sloping is lined up in
the same direction as the sloped surface.
REMOTE CONTROL: ARROW BUTTONS
The arrow buttons (O, P) are used for different functions depending
on the operating mode of the laser unit.
In Self-Leveling Horizontal Mode:
The up and down arrows (O) adjust the length of the laser line
in Scan Mode.
The left and right arrows (P) adjust the direction of the laser
beam in Scan Mode or Pointing Mode (0 rpm).
In Self-Leveling Vertical Mode:
The up and down arrows (O) adjust the position of the laser
line in Scan Mode.
English
13
The left and right arrows (P) move the laser beam left and
right.
In Manual Mode:
The arrow buttons (O) are used to tilt the laser head up or
down in the X or Y directions as marked on the protective roll
cage of the laser unit.
REMOTE CONTROL: SPEED/ROTATION BUTTON
The speed/rotation button (Q) is used to adjust the speed of the
laser beam through its 4 preset speeds.
NOTE: The speed/rotation button performs the same function as
the speed/rotation button on the control panel of the laser unit.
REMOTE CONTROL: SCAN MODE BUTTON
The scan mode button (R) is used to make the laser head sweep
back and forth, creating a short, bright laser line. This short line is
much brighter and more visible than when the unit is in full rotation
mode.
Using Scan Mode:
To enter Scan Mode, push and release the scan mode button.
To exit Scan Mode, push and release the button again.
The size and direction of the scan zone can be controlled
with the arrow buttons on the laser unit control panel or the
remote control. For a more detailed explanation, refer to
Arrow Buttons under Laser Control Panel Buttons.
IMPORTANT: The remote control cannot be used for User
Defined Scan Mode.
REMOTE CONTROL: PUBLIC AND PRIVATE MODE
The DW079 Rotary Laser and the DW0794 Remote Control each
have the capability to operate in either Public Mode or Private
Mode. For the laser and the remote control to work together, they
must both be set to the same mode.
Public Mode
The remote control sends signals that can potentially be
received by multiple laser units as well as other models of
laser units. This is the normal, default operating mode for the
DW0794 remote control.
To activate Public Mode:
Press and hold the speed/rotation button (Q) (open
padlock symbol beside the button) for 4 seconds.
After an 8-hour period of inactivity, the remote control
will automatically enter Public Mode.
After replacement of its battery, the remote control will
automatically enter Public Mode.
Private Mode
The remote control sends signals that can only be received by
the designated laser unit.
To activate Private Mode:
Press and hold the remote control scan mode button
(R) (closed padlock symbol beside the button) and at
the same time, press and hold the scan mode button
(F) on the laser unit control panel (closed padlock
symbol).
After 4 seconds, both the remote control and the laser
unit will enter Private Mode. As confirmation, the laser
unit will beep and the laser unit control panel LED (L)
(next to the closed padlock symbol) and the remote
control LED (T) (next to the closed padlock symbol) will
flash.
Height of Instrument Alert
The DW079 has a built-in alarm feature that alerts the operator if
the unit is disturbed after the unit has self-leveled. The laser unit will
stop rotating, the control panel LED indicator lights will flash and the
beeper will sound.
English
14
TO RESET THE LASER UNIT FOR CONTINUED USE
Turn the unit off and back on again using the power button on
the laser unit control panel.
OR
Put the unit in sleep mode and then wake it back up using the
power button on the remote control.
NOTE: Always recheck the laser setup after the Height of
Instrument Alert has triggered.
Laser Troubleshooting
LASER AND REMOTE CONTROL ARE OUT OF SYNC
On the remote control, press and hold speed/rotation button for
4 seconds to activate Public Mode.
On the laser unit, press and hold speed/rotation button for
4 seconds to activate Public Mode.
Using the Laser on a Tripod
1. Position the tripod securely and set it to the desired height.
2. Make sure that the top of the tripod is roughly level. The laser
will self-level only if the top of the tripod is within ± 5˚ of level. If
the laser is set up too far out of level, it will beep when it reaches
the limit of its leveling range. No damage will be done to the
laser, but it will not operate in an “out of level” condition.
3. Secure the laser to the tripod by screwing the threaded knob on
the tripod into the female thread on the bottom of the laser.
NOTE: Be sure that the tripod you are working with has a
5/8"–11 threaded screw to ensure secure mounting.
4. Turn the laser on and adjust the rotation speed and controls as
desired.
Using the Laser on a Floor (Fig. 5)
The laser level can be positioned directly on the floor for leveling
and plumbing applications such as framing walls.
1. Place the laser on a relatively smooth and level surface where
it will not be disturbed.
2. Position the laser for a level or plumb setting as shown.
3. Turn the laser on and adjust the rotation speed and controls as
desired.
LEVEL
MODE
PLUMB
MODE
FIG. 5
NOTE: The laser will be easier to set up for wall applications if the
rotation speed is set to 0 rpms and if the remote control is used to
line up the laser with control marks. The remote allows one person
to set up the laser.
Manual Head Rotation
The laser is designed with a protective alloy cage around the rotary
head to prevent accidental damage from work site activities. You
can still access the rotary head and manually direct the beam to
establish or transfer a mark.
Laser Accessories
Recommended accessories for use with your tool are available for
purchase at your factory-owned local service center.
WARNING: Since accessories, other than those offered by
DEWALT, have not been tested with this product, use of such
English
15
accessories with this tool could be hazardous. To reduce the risk
of injury, only DEWALT, recommended accessories should be used
with this product.
If you need assistance in locating any accessory, please contact
DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD
21286, call 1-800-4-DEWALT (1-800-433-9258) or visit our website
www.dewalt.com
Laser Enhancement Glasses
Some laser kits include a pair of FIG. 6
Laser En hancement Glasses (Fig. 6).
These red lens glasses improve the
visibility of the laser beam under
bright light conditions or over long
distances when the laser is used for
interior applications. These glasses
are not required to operate the laser.
CAUTION: These glasses are not ANSI approved safety glasses
and should not be worn while operating other tools. These glasses
do not keep the laser beam from entering your eyes.
DANGER: TO REDUCE THE RISK OF SERIOUS PERSONAL
INJURY, NEVER STARE DIRECTLY INTO THE LASER BEAM,
WITH OR WITHOUT THESE GLASSES.
Target Card
Some laser kits include a Laser Target Card
FIG. 7
(Fig. 7) to aid in locating and marking the laser
beam. The target card enhances the visibility of the
laser beam as the beam crosses over the card. The
card is marked with standard and metric scales.
The laser beam passes through the red plastic and
reflects off of the reflective tape on the reverse side.
The magnet at the top of the card is designed to
hold the target card to ceiling track or steel studs to determine
plumb and level positions. For best performance when using the
Target Card, the DEWALT logo should be facing you.
Digital Laser Detector: DW0772
(Fig. 8–10)
Some laser kits include a DEWALT Digital Laser Detector. The
DEWALT Digital Laser Detector allows you to locate a laser beam
emitted by a rotary laser in bright light conditions or over long
distances. The detector can be used in both indoor and outdoor
situations where it is difficult to see the laser beam.
DD
X
W
AA
Z
V
U
FIG. 8
The detector is not for use with non-rotating lasers but is compatible
with most rotary red-beam or infrared (invisible) beam lasers on the
market. It can be set to indicate the location of the beam to either
the nearest 1/8" (3 mm) or the nearest 1/25" (1 mm). The detector
gives both visual signals through the display window (V) and audio
signals through the speaker (W) to indicate the location of the laser
beam.
English
16
The DEWALT Digital Laser Detector can be used with or without
the detector clamp. When used with the clamp, the detector can be
positioned on a grade rod, leveling pole, stud or post.
BATTERIES (FIG. 9)
X
Y
FIG. 9
The Digital Laser Detector is powered by a
9 volt battery. To install the battery pro-
vided, lift up on the battery compartment
cover (X). Place the 9 volt battery in
the compartment, aligning the battery as
shown on the embossed icon (Y).
DETECTOR CONTROLS (FIG. 10)
The detector is controlled by the power/
volume button (Z) and the accuracy mode
button (AA).
When the power/volume button is pushed
CC
BB
AA2
AA1
FIG. 10
once, the detector is turned on. The top of
the display window shows the ON icon
(BB), and the volume icon (CC). To
decrease the volume of the audible signal
that the detector emits when it senses a
laser beam, push the button again; one of
the half circles next to the horn icon will
dissappear. To turn off the audible signal
push the button a third time; the volume
icon will dissapear. The DEWALT Digital
Laser Detector also has an auto shut-off
feature. If a rotary laser beam does not strike the beam detection
window, or if no buttons are pressed, the detector will shut itself off
in about 30 minutes.
When the detector is on, the bottom of the window shows an
accuracy mode icon. Either the ±1/25" (1 mm) accuracy mode icon
(AA1) will appear, or the ±1/8" (3 mm) accuracy mode icon (AA2)
will appear. When the ±1/25" (1 mm) accuracy mode icon appears,
it indicates that the detector will give an “on grade” reading only
when the laser beam is on grade or no more than 1/25" (1 mm)
above or below it. When the 1/8" (3 mm) accuracy mode icon
appears, it indicates that the detector will give an “on grade”
reading when the laser beam is on grade or approximately 1/8"
(3 mm) above or below it. Push the accuracy mode button (AA)
once to change the accuracy mode.
Detector Operation (Fig. 11)
1. Set up and position the rotary laser that you will be using
according to the manufacturer’s directions. Turn the laser on and
make sure that the laser is rotating and emitting a laser beam.
Slightly Slightly
Above Above On Below Below
Grade Grade Grade Grade Grade
fast fast steady slow slow
beep beep tone beep beep
audible
signals
INDICATORS
display icons
FIG. 11
NOTE: This detector has been designed to be used only with a
rotating laser. The detector will not work with a stationary beam
laser level.
2. Turn the detector on by pressing the power/volume button (Z).
English
17
3. Adjust the volume as desired as described in the Detector
Controls.
4. Position the detector so that the detector window (U) is facing
the laser beam produced by the rotary laser. Move the detector
up or down within the approximate area of the beam, until you
have centered the detector. For information about the display
window indicators and the audible signal indicators, refer to
the table titled Indicators (Fig. 11).
5. Use the marking notches (DD) to accurately mark the position
of the laser beam.
II
JJ
HH
GG
FF
EE
FIG. 12
DD
MOUNTING ON A GRADE ROD (FIG. 12)
1. To secure your detector to a grade rod, first attach the detector
to the clamp by pushing in on the clamp latch (EE). Slide the
tracks (FF) on the clamp around the rail (GG) on the detector
until the latch (HH) on the clamp pops into the latch hole (II) on
the detector.
2. Open the jaws of the clamp by turning the clamp knob (JJ)
counterclockwise.
3. Position the detector at the height needed and turn the clamp
knob clockwise to secure the clamp on the rod.
4. To make adjustments in height, slightly loosen the clamp,
reposition and retighten.
Detector Cleaning and Storage
Dirt and grease may be removed from the exterior of the
detector using a cloth or soft, non-metallic brush.
The DEWALT Digital Laser Detector is waterproof. If you should
drop the detector in mud, wet concrete, or a similar substance,
simply hose the detector off. Do not use high pressure water,
e.g., from a pressure washer.
The best storage place is one that is cool and dry–away from
direct sunlight and excess heat or cold.
Detector Service
Except for batteries, there are no user serviceable parts in the
Digital Laser Detector. Do not disassemble the unit. Unauth orized
tampering with the laser detector will void all warranties.
Detector Troubleshooting
THE DETECTOR WILL NOT TURN ON.
• Press and release the power/volume button.
Check to see that the battery is in place and in the proper
position.
If the detector is very cold, allow it to warm up in a heated
area.
• Replace the 9 volt battery. Turn the unit on.
If the detector still does not turn on, take the detector to a
DEWALT service center.
THE DETECTOR’S SPEAKER MAKES NO SOUND.
• Ensure that the detector is on.
English
18
Press the power/volume button. It will toggle from high, to low,
to mute.
Ensure that the rotary laser is spinning and that it is emitting a
laser beam.
If the detector is still not making any sound, take it to a DEWALT
service center.
THE DETECTOR DOES NOT RESPOND TO A STATIONARY
LASER BEAM.
The DEWALT Digital Laser Detector has been designed to work
only with rotary lasers.
THE DETECTOR GIVES OFF A TONE BUT THE LCD
DISPLAY WINDOW DOES NOT FUNCTION.
If the detector is very cold, allow it to warm up in a heated
area.
• If the LCD display window is still not functioning, take the
detector to a DEWALT service center.
Construction Grade Rod
DANGER: NEVER attempt to use a grade rod in a storm or
near overhanging electric wires. Death or serious personal injury
will occur.
Some laser kits include a grade rod. The DEWALT FIG. 13
Grade Rod is marked with measurement scales
on both sides and is constructed in telescoping
sections. A spring-loaded button actuates a lock to
hold the grade rod at various lengths.
The front of the grade rod has the measurement
scale starting at the bottom. Use this for measuring
from the ground up when grading or leveling jobs.
The back of the grade rod is designed to measure
the height of ceilings, joists, etc. Fully extend the
top section of the grade rod until the button locks into the previous
section. Extend that section either until it locks into the adjacent
section or until the grade rod touches the ceiling or joist. The height
is read where the last extended section exits the previous lower
section, as shown in Figure 13.
Using the Laser with a Wall Mount
(Fig. 14, 15)
Some laser kits include a Wall Mount. It can be used for attaching
the tool to track or ceiling angle and to aid in acoustical ceiling
installation. Follow the directions below for using the wall mount.
CAUTION: Before attaching the laser level to wall track or ceiling
angle, be sure that the track or angle is properly secured.
1. Place the laser on the mounting base (KK) aligning the hole (LL)
on the bottom of the laser with the hole (MM) in the mounting
base. Turn the mounting knob (NN) to secure the laser.
PP
QQ
LL
SS
RR
NN
OO
PP
MM
KK
FIG. 14
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

DeWalt DW079KDT Le manuel du propriétaire

Taper
Le manuel du propriétaire