6
Version 11 IBM 46XX Scanner
Output Format: IBM RS-485 serial input/output for the 4680 and 4690
(46XX) point-of-sale terminals
The Version 11 46XX interface can be used in several different ways. Both the
46XX terminal and the scanner must be configured to match each other.
Warning: Power to the scanner and 46XX terminal should be turned off
before making physical connection.
The 4680 and 4690 series terminals have different types of physical ports for
connecting bar code scanners. Scanner ports include Port 5B, Port 17, and
Port 9? (? = A, B, C, or E). A Port 9 type connector is present on all versions
of the 46XX families of terminals. That is one reason it is the normal point of
connection for Metrologic scanners. Another reason is that there is enough 12
volt power available to operate many Metrologic scanners. If the terminal
configuration requires use of a different physical port for connecting bar code
scanners, contact Metrologic to get particular adaptor cable information.
No matter what port is in use for the physical connection, all devices use a
common communications bus inside the 46XX terminal. Each device uses a
different address when it must communicate. The terminal must be configured
to look for a device at a logical address.
The IBM 1520 mode/address was selected as a default because it was the first
IBM 46XX family scanner to support UPC/EAN, Code 39 and Interleaved 2
of 5. The Version 11 scanner formats Codabar, Code 128, and Code 93 using
the Code 39 function code designation supported by the IBM device driver for
this scanner type. Other emulation modes currently available are the IBM
3687-2 Port 17 fixed scanner and the Port 9B IBM 4500 CCD hand-held bar
code reader. One of these other emulation modes may be needed depending on
which operating system (4680.OS, 4690.OS, POS/DOS or DOS/RIPPS) is in
use at the site.
Note: The IBM 4683 and IBM 4684 terminals have a good proven track
record of supplying power to Metrologic scanners. The IBM 4693
and IBM 4694 terminals may be restricted from supplying power to
certain scanner models. Specifically, Metrologic currently
recommends using an external power supply for the scanner when
connecting to an IBM 4694. Metrologic has no recommendations at
this time for IBM 4693 terminals.