VeriFone Vx 675 Quick Installation Guide

Taper
Quick Installation Guide
c
2016 Verifone, Inc. All rights reserved.
Verifone, Inc.
1-800-Verifone
www.verifone.com
VX 675 WiFi-BT ATEX Certifications and Regulations
Verifone Part Number: DOC265-042-EN-B Revision B
*DOC265-042-EN-B*
Electrical
Power Packs
Before you connect the terminal power pack to an electrical outlet, check that the on/off power switch on the terminal is off. If the terminal does not have an on/
off switch, check that the power cable connector is removed from the terminal’s power port.
Or, when connecting the terminal to a power pack, always connect the plug of the power pack to an electrical wall outlet first. Then connect the power cable to
the terminal’s power port.
The power pack is rated as follows:
Input Voltage: 100 - 240 V AC, 50/60 Hz
Output Voltage: 5 V DC, 1 A
Model VX 675 WiFi-BT is intended to be provided with appropriately certified power module suitable for the destination country with an output rating of 5 V DC,
min 1 A and evaluated as a Limited Power Source, output rated SELV, non-energy hazardous. Suitability of power module subject to auditing agency’s
discretion
.
AC Adapter
The AC adapter is designed to ensure your personal safety and to be compatible with this equipment. Please follow these guidelines:
Do not use the adapter in a high moisture environment. Never touch the adapter when your hands or feet are wet.
Allow adequate ventilation around the adapter. Avoid locations with restricted airflow.
Connect the adapter to a proper power source. The voltage and grounding requirements are found on the product case and/or packaging.
Do not use the adapter if the cord becomes damaged.
Do not attempt to service the adapter. There are no serviceable parts inside. Replace the unit if it is damaged or exposed to excess moisture.
Separate Power Sources
Some peripherals require a separate power source. Before connecting a check reader or similar device, remove the power cable connector from the terminal’s
power port.
Peripherals
Before connecting any peripheral device, turn off power to the terminal and check that the power cable connector is removed from the terminal’s power port.
Turn on power only after you are finished connecting the peripheral device(s). For complete information about peripheral installation and use, please refer to
the user documentation supplied with those devices.
Telecommunication Cord
Caution: To reduce the risk of fire, use only No. 26 AWG or larger UL Listed or CSA Certified Telecommunication Line Cord.
Pour réduire les risques d'incendie, utilisez uniquement les cordons téléphoniques No. 26 AWG ou UL Listed ou certifiés CSA
Disconnecting Power
Disconnecting power during a transaction may cause transaction data files that are not yet stored in terminal memory to be lost.
Location – Electrical Considerations
CAUTION: Due to risk of electrical shock or terminal damage, do not use the terminal near water, including a bathtub, wash bowl, kitchen sink or laundry tub,
in a wet basement, or near a swimming pool. Also, avoid using this product during electrical storms. Avoid locations near electrical appliances or other devices
that cause excessive voltage fluctuations or emit electrical noise (for example, air conditioners, neon signs, high-frequency or magnetic security devices, or
electric motors).
Du fait d'un risque d'électrocution ou d'une détérioration du terminal, ne pas utiliser cet équipement près d'une source d'eau, par exemple près
d'une baignoire, d'un lavabo, d'un évier de cuisine ou d'un bac de lavage, dans un sous-sol humide ou à proximité d'une piscine. De même, éviter
d’utiliser ce produit lors des orages provoquant des coupures électriques. Éviter de placer le terminal à proximité d’appareils électriques ou autres
unités pouvant entraîner des fluctuations de tension importantes ou des interférences électriques, tels que les climatiseurs, enseignes au néon,
dispositifs de sécurité à haute fréquence ou équipements électriques.
Equipment
Repairs
Do not, under any circumstances, attempt any service, adjustments, or repairs on this equipment. Instead, contact your local Verifone distributor or service
provider for assistance. Failure to comply may void the product warranty.
Location – Environmental Considerations
Do not plug the power pack into an outdoor outlet or operate the terminal outdoors. It is not waterproof or dust proof, and is for indoor use only. Any damage
to the unit from exposure to rain or dust may void your warranty. Always use your ATEX terminal in its pouch. Do not expose your terminal to rain. Do not use
the terminal where there is high heat, dust, humidity, moisture, or caustic chemicals or oils. Keep the terminal away from direct sunlight and anything that
radiates heat, such as a stove or a motor.
WARNING! Your POS Terminal contains sensitive electronic components that can be permanently damaged if exposed to excessive shock or vibration. To
minimize the risk of damage to your Terminal, avoid dropping your Terminal and operating it in high-shock and high-vibration environments. Do
not store the Terminal where prolonged exposure to extreme temperature can occur, because it can cause permanent damage. Do not expose
the Terminal to water. Contact with water can cause this unit to malfunction.
Votre terminal de point de vente contient des composants électroniques sensibles, susceptibles de subir des dommages définitifs en cas
d'exposition à des chocs ou à des vibrations excessives. Pour minimiser le risque de dommages pour votre terminal, éviter de le faire tomber ou
de l'exposer à des environnements pouvant provoquer des chocs et des vibrations excessives. Ne pas stocker le terminal dans des lieux
susceptibles d'entraîner une exposition prolongée à des températures extrêmes, du fait des dommages définitifs que cette situation peut
provoquer. Ne pas exposer le terminal à l'eau. Un contact avec de l'eau peut provoquer un dysfonctionnement de l'unité.
VX 675 WiFi-BT ATEX Certifications and Regulations
FCC Compliance
The following device has been tested and certified as compliant with the regulations and guidelines set forth in Part 15 of FCC Rules:
Manufacturer: Verifone, Inc.
Brand, Model: VX 675 WiFi-BT
Part 15 of FCC Rules
This device complies with the limits for a Class B digital device as specified in Part 15 of FCC Rules which provide reasonable protection
against harmful interference in a residential area.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference; and,
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. In the unlikely event that there is interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult with the dealer or ask an experienced radio/TV technician for help.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Use of a shielded
interface cable is required to comply with the Class B limits of Part 15 of FCC Rules. Any changes or modifications to this equipment not
expressly approved by Verifone could void the user’s authority to operate this equipment.
RF Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. To comply with Council
Recommendation 1999/519/EC and FCC RF exposure requirement, a minimum separation distance of 20 cm must be maintained
between the user's body and the device, including the antenna.
SAR Labeling
Wi-Fi
USA
For body-worn operation, this device has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains
no metal parts and positions the handset a minimum of 0 cm from the body. Use of other accessories may not ensure compliance with
FCC RF exposure guidelines. The highest SAR value for the device as reported to the FCC when tested for use when worn on the body,
as described in the user guide, is 0.06 W/kg.
This device complies with SAR for general population/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and has been tested in
accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C.
Legal Terms and Conditions Regarding PCI SSC Approvals
PCI SSC’s approval only applies to PEDs that are identical to the PED tested by a PCI Security Standards Council recognized laboratory.
If any aspect of the PED is different from that which was tested by the laboratory - even if the PED conforms to the basic product
description contained in the letter, then the PED model should not be considered approved, nor promoted as approved. For example, if a
PED contains firmware, software, or physical construction that has the same name or model number as those tested by the laboratory,
but in fact are not identical to those PED samples tested by the laboratory, then the PED should not be considered or promoted as
approved.
No vendor or other third party may refer to a PED as “PCI Approved,” nor otherwise state or imply that PCI SSC has, in whole or part,
approved any aspect of a vendor or its PEDs, except to the extent and subject to the terms and restrictions expressly set forth in a written
agreement with PCI SSC, or in an approval letter. All other references to PCI SSC’s approval are strictly and actively prohibited by PCI
SSC.
When granted, an approval is provided by PCI SSC to ensure certain security and operational characteristics important to the
achievement of PCI SSC’s goals, but the approval does not under any circumstances include any endorsement or warranty regarding the
functionality, quality, or performance of any particular product or service. PCI SSC does not warrant any products or services provided by
third parties. Approval does not, under any circumstances, include or imply any product warranties from PCI SSC, including, without
limitation, any implied warranties of merchantability, fitness for purpose or non infringement, all of which are expressly disclaimed by PCI
SSC. All rights and remedies regarding products and services, which have received an approval, shall be provided by the party providing
such products or services, and not by PCI SSC or the payment brand participants.
This equipment operates on a secondary basis, and must not cause interference to systems operating on a primary basis. As secondary
equipment, it is not protected from harmful interference, even from stations of the same type.
Recycling: DO NOT DISCARD!
UNIT MUST BE RECYCLED OR DISPOSED OF PROPERLY
For proper disposal instructions go to http://recycle.verifone.com/
Please retain this sheet for future reference.
continued on rear cover
VX 675 WiFi-BT ATEX Declaration of Conformity
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
______________________________________________________________________
Manufacturer’s Name Verifone, Inc.
Manufacturer’s Address Verifone, Inc.
88 West Plumeria Drive
San Jose, CA 95134, USA
Declares, that the product
Product Name: VX 675 WiFi-BT
Model Number: VX 675 WiFi-BT
Part Number: M265-XXX-XX-XXX-X
Brand: Verifone
Product Options:All
Conforms to the following product specifications:
Safety: IEC 60950-1:2005+A1:2009+A2:2013
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
EMC: EN 55022:2010+AC:2011 (Class B)
EN 55024:2010
EN 61000-3-2:214 (Class A)
EN 61000-3-3:2013
WIFI/BT: EN 301 489-1 V1.9.2
EN 301 489-17 V2.2.1
EN 300 328 V1.9.1
RFID: ETSI EN 302 291-1 V 1.1.1 (2005-07)
ETSI EN 302 291-2 V 1.1.1 (2005-07)
EN 301 489-1 V1.9.2
EN 301 489-3 V1.6.1
SAR: EN 62311:2008
EN 62209-2:2010/IEC 62209-2:2010
EN 62479:2010
Also conform with the provisions of the Directive 2014/34/EU for use in potentially explosive atmospheres:
Marking: II 3G Ex ic IIA T3 Gc 0 °C Ta +40 °C
Standards: IEC60079-0:2012
IEC60079-11:2012
Type Examination Certificate Number: ITS16ATEX28411X
Intertek ExTR Reference Number: 102328522DAL-001
Notification Body: Intertek Testing & Certification Limited.
Intertek House, Cleeve Road,
Leatherhead, Surrey KT2272SB
US Project Number: G102328522
EC Directives: 2014/34/EU (ATEX Directive)
2014/30/EU (EMC Directive)
Supplementary Information:
We hereby declare that this device complies with the requirements of Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and R&TTE
Directive 1999/5/EC. This also carries the CE Mark per Directive 93/68/EEC, and conforms to RoHS Directive 2011/65/EU, as well as Technical
Documentation: EN 50581:2012 and DIN EN 50581 (2013-02).
Dated: November 22, 2016
Sheetal Shah
Chief Operations Officer
Global Supply Chain
San Jose, CA, USA
European contact for regulatory topics only: Verifone UK Ltd.
Symphony House
7 Cowley Business Park
High Street
Cowley Uxbridge, UB8 2AD
United Kingdom
Tel: +44-1895-275275
  • Page 1 1
  • Page 2 2

VeriFone Vx 675 Quick Installation Guide

Taper
Quick Installation Guide

dans d''autres langues