Wacker Neuson PSW31500 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

Pump
PS2 800
PSA2 800
PSW3 1500
OPERATOR’S MANUAL
0176745en 001
0209
0176745EN
Foreword
wc_tx001080gb.fm 3
Foreword
Machines covered in this manual
This manual provides information and procedures to safely operate
and maintain this Wacker Neuson model. For your own safety and
protection from injury, carefully read, understand and observe the
safety instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this
manual or need an additional copy, please contact Wacker Neuson
Corporation. This machine is built with user safety in mind; however,
it can present hazards if improperly operated and serviced. Follow
operating instructions carefully! If you have questions about operating
or servicing this equipment, please contact Wacker Neuson
Corporation.
The information contained in this manual was based on machines in
production at the time of publication. Wacker Neuson Corporation
reserves the right to change any portion of this information without
notice.
All rights, especially copying and distribution rights, are reserved.
Copyright 2009 by Wacker Neuson Corporation.
No part of this publication may be reproduced in any form or by any
means, electronic or mechanical, including photocopying, without
express written permission from Wacker Neuson Corporation.
Any type of reproduction or distribution not authorized by Wacker
Neuson Corporation represents an infringement of valid copyrights
and will be prosecuted. We expressly reserve the right to make
technical modifications, even without due notice, which aim at
improving our machines or their safety standards.
Machine Item Number
PS2 800 0620436
0620442
PSA2 800 0620443
PSW3 1500 0620339
0620444
Foreword
wc_tx001080gb.fm 4
PS / PSA / PSW... Table of Contents
wc_bo0176745en_001TOC.fm 5
1. Foreword 3
2. Safety Information 6
2.1 Operating and Electrical Safety ............................................................ 7
2.2 Informational Labels ............................................................................. 7
3. Operation 8
3.1 Names of Parts ..................................................................................... 8
3.2 Prior to Operation ................................................................................. 9
3.3 Installation ............................................................................................ 9
3.4 Electrical Wiring .................................................................................. 14
3.5 Electrical Circuit Diagrams ................................................................. 16
3.6 Operation ............................................................................................ 18
4. Maintenance 23
4.1 Periodic Maintenance Table ............................................................... 23
4.2 Maintenance and Inspection .............................................................. 24
4.3 Disassembly/Reassembly .................................................................. 27
4.4 Disassembly (PS / PSA) ..................................................................... 28
4.5 Reassembly (PS / PSA) ..................................................................... 29
4.6 Disassembly (PSW) ........................................................................... 30
4.7 Reassembly (PSW) ............................................................................ 31
4.8 Troubleshooting .................................................................................. 32
5. Technical Data 34
5.1 Standard Specifications ...................................................................... 34
5.2 Operating Specifications .................................................................... 35
5.3 Dimensions ........................................................................................ 36
Safety Information PS / PSA / PSW...
wc_si000289gb.fm 6
1. Safety Information
This manual contains DANGER, WARNING, CAUTION, NOTICE and
NOTE callouts which must be followed to reduce the possibility of
personal injury, damage to the equipment, or improper service.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE: Used without the safety alert symbol, NOTICE indicates a
situation which, if not avoided, could result in property damage.
Note: Contains additional information important to a procedure.
DANGER
WARNING
CAUTION
PS / PSA / PSW... Safety Information
wc_si000289gb.fm 7
1.1 Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded,
grounding-type receptacle.
Risk of electric shock—this pump has not been investigated for use in
swimming pool areas.
An acceptable motor-control switch shall be provided at the time of
installation according to local codes and regulations.
To reduce risk of electric shock, follow instructions in this manual for
proper installation.
CAUTION: This pump may automatically restart. Prior to working on
the pump or control panel, all supply circuits must be disconnected.
CAUTION: Risk of shock—do not remove cord and strain relief.
1.2 Informational Labels
Label Meaning
A nameplate listing the model number, item num-
ber, revision number, and serial number is
attached to each unit. Please record the informa-
tion found on this plate so it will be available
should the nameplate become lost or damaged.
When ordering parts or requesting service infor-
mation, you will always be asked to specify the
model number, item number, revision number,
and serial number of the unit.
WARNING
Wacker Neuson Corporation
Menomonee Falls, WI 53051 USA
Model Item No. Rev.
Serial No.
VHz
kWkgMax. L/minMax. m
MADE IN
TAIWAN
HPlbsMax. GPMMax. ft
CUS
L
I
S
T
E
D
R
Phase
C22.2 No. 108-M89
2001993
Conforms to UL Std. 778
Cert. to CAN/CSA St d.
Amp.
Man. Y/M
THERMALLY PROTECTED
INDOORS OR OUTDOORS
CSA ENCLOSURE 3
Operation PS / PSA / PSW...
wc_tx000989gb.fm 8
2. Operation
2.1 Names of Parts
See Graphic: wc_gr005716
Ref Description Ref Description
1 Lifting handle 8 Seal-mechanical
2 Coupling 9 Lubricant
3 Oil lifter 10 Seal-dust
4 Oil plug 11 Sleeve
5 Cover-suction 12 Housing-oil
6 Strainer 13 Wear ring
7 Cable assembly 14 Impeller
1
2
2
7
8
9
10
11
12
13
14
3
4
5
6
wc_gr005716
2
PS / PSA / PSW... Operation
wc_tx000989gb.fm 9
2.2 Prior to Operation
When the pump is delivered, first perform the following checks:
Inspection
While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
Specification check
Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note: If there is any problem with the product as shipped, contact your
nearest dealer or Wacker Neuson representative at once.
Product specifications
Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
electrical shock, current leakage, fire, water leakage or other
problems.
2.3 Installation
If the pump is used for outdoor fountains, garden ponds and similar
places, or to drain a swimming pool, the pump must be supplied by an
isolating transformer or connected to a Residual Current Device (RCD)
with a residual operating current not exceeding 30 mA.
The pump must not be used when people are in the water.
Leakage of pump lubricants may cause pollution of water.
Proper plug must be provided according to local codes and standards.
Refer to wiring diagram.
Do not use this pump in liquids other than water, such as oil, salt water,
or organic solvents.
Use with a power supply voltage within ±5% of the rated voltage.
Do not use in water temperatures outside the range of 0–40°C
(32–104°F) which can lead to failure, electrical leakage or shock.
Do not use in the vicinity of explosive or flammable materials.
Use only in fully assembled state.
Note: Consult your local dealer or Wacker Neuson representative
before using with any liquids other than those indicated in this manual.
CAUTION
WARNING
Operation PS / PSA / PSW...
wc_tx000989gb.fm 10
Preparing for installation
Before installing the pump at a work site, you will need to have the
following tools and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note: Please also read the instructions that come with each of the test
instruments.
Checks to make before installation
When a grounded plug is used:
Use the megohmmeter to measure the insulation resistance between
the cable assembly prongs and ground.
When connection leads are used:
With the megohmmeter, measure the insulation resistance between
each core lead and the ground lead.
Reference insulation resistance: 20MW or greater
Note: The reference insulation resistance (20MW or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation, see “Periodic Maintenance Table.”
Improper ways to measure insulation resistance
See Graphic: wc_gr000258
1. Between the plug prongs.
2. Between the electrodes on the level relay unit.
3. Between the electrodes on the level relay unit and the plug prongs.
1
2
wc
_
gr000258
3
PS / PSA / PSW... Operation
wc_tx000989gb.fm 11
Precautions during installation
Do not under any circumstances install or move the pump by
suspending it from the cable assembly. The cable may be damaged,
causing electrical leakage, shock, or fire.
When installing the pump, pay close attention to its center of gravity
and weight. If it is not lowered into place correctly, it may fall and be
damaged or cause injury.
When transporting the pump by hand, be sure to employ manpower
commensurate with the weight of the pump. To avoid back injury when
lifting the pump, bend the knees to pick it up rather than bending your
back only.
2.3.1 This pump series is offered with a variety of discharge fittings. Follow
procedures noted below to assure a proper discharge connection.
Threaded Discharge Fitting (BSP) –
Tighten hose coupling or discharge pipe securely and with proper
gaskets.
Quick Disconnect Coupling (QD) –
Assure coupling is tightened securely to pump discharge fitting and
companion coupling is securely fastened with proper gaskets.
Barbed Discharge Fitting (Barb) –
Place hose clamp over hose and push hose to the base of the
discharge fitting. Tighten the hose clamp to secure the hose in place.
2.3.2 Avoid dropping the pump or other strong impact. Lift the pump by
holding it firmly with the hands or by attaching a rope or chain to the
handle.
Note: On cable assembly handling, see “Electrical Wiring.
2.3.3 Install the pump in a location with sufficient water level, where water
collects readily.
Note: See “Operating Water Level” for the water level necessary for
operation. The discharge end of the hose should be located higher
than the water surface. If the end of the hose is submerged, water may
flow back to the pump when the pump is stopped; and if the hose end
is lower than the water surface, water may overflow when the pump is
turned off.
2.3.4 The hose should be run as straight as possible, since excessive
bending will hinder the water flow, preventing sufficient lift, and can
even cause the hose to become clogged with earth. If the hose is
crimped near the pump, air can become trapped in the pump and
cause idle running.
WARNING
CAUTION
Operation PS / PSA / PSW...
wc_tx000989gb.fm 12
If large quantities of earth are sucked up, damage resulting from
friction in the pump can lead to electrical leakage and shock.
2.3.5 Use the pump in the upright position. To prevent the pump from
becoming submerged in mud, mount it on a block or other firm base if
necessary.
2.3.6 If used in a permanent installation, where the pump is not readily
accessible after installation, please contact Wacker Neuson for a
duplicate nameplate to be installed at the wellhead or on the control
box so that it will be readily visible.
CAUTION
PS / PSA / PSW... Operation
wc_tx000989gb.fm 13
Notes:
Operation PS / PSA / PSW...
wc_tx000989gb.fm 14
2.4 Electrical Wiring
Performing electrical wiring
Electrical wiring should be performed by a qualified person in accord
with all applicable regulations. Failure to observe this precaution not
only risks breaking the law but is extremely dangerous.
Incorrect wiring can lead to current leakage, electrical shock or fire.
Always make sure the pump is equipped with the specified overload
protectors and fuses or breakers, so as to prevent electrical shock from
a current leak or pump malfunction.
Operate within the capacity of the power supply and wiring.
Grounding
Do not use the pump without first grounding it properly. Failure to
ground it can lead to electrical shock from a current leak or pump
malfunction.
Do not attach the grounding wire to a gas pipe, water pipe, lightning
arrester or telephone grounding wire. Improper grounding can result in
electrical shock.
Connecting the power supply
Before connecting leads to the terminal strip, make certain the power
supply is turned off (circuit breaker, etc.), to avoid electrical shock,
shorting, or unexpected starting of the pump, leading to injury.
Before inserting the power supply plug, make certain the power supply
is turned off (circuit breaker, etc.), to avoid electrical shock, shorting,
or unexpected starting of the pump, leading to injury.
Do not use the pump with the cable assembly or plug connected
loosely, which can result in electric shock, shorting, or fire.
Draw power from a dedicated power outlet rated at 15 A or above.
Sharing the outlet with other equipment may cause overheating at the
branch outlet and could result in fire.
NOTICE: Be sure to use a dedicated power supply with a ground
leakage circuit breaker.
Grounded plug
Connect only to receptacle of proper voltage and current rating
matching that of the plug provided with the cable assembly.
WARNING
WARNING
CAUTION
WARNING
CAUTION
PS / PSA / PSW... Operation
wc_tx000989gb.fm 15
Without Plug
Tighten the ends of the cable assembly securely against the terminal
board. If installation of a grounded plug is required, use only a properly
rated and approved CEE plug and secure the ends of the cable
assembly securely to power and ground terminals in accordance with
the plug manufacturer’s instructions.
See Graphic: wc_gr000309
Cable Assembly
If it is necessary to extend the cable assembly, use a core size equal
to or larger than the original. This is necessary not only to avoid a
performance drop, but to prevent cable overheating which can result in
fire, electrical leakage or electrical shock.
If a cable with cut insulation or other damage is submerged in the
water, there is a danger of damage to the pump, electrical leakage,
electrical shock, or fire.
Be careful not to let the cable assembly be cut or become twisted. This
may result in damage to the pump, electrical leakage, electrical shock,
or fire.
If it is necessary to submerge the connection wires of the cable
assembly in water, first seal the wires completely in a molded
protective sleeve, to prevent electrical leakage, electrical shock, or fire.
Do not allow the cable assembly wires or power supply plug to become
wet.
Make sure the cable does not become excessively bent or twisted, and
does not rub against a structure in a way that might damage it.
If used in a deep-well installation, the cable assembly should be
secured every twenty feet.
Br
L
L1
L2
G/Y
wc
_
gr000309
G
CAUTION
Operation PS / PSA / PSW...
wc_tx000989gb.fm 16
2.5 Electrical Circuit Diagrams
See Graphic: wc_gr005717
Ref. Description Ref. Description
1 Capacitor 7 Heater
2 Main coil 8 Level relay unit
3 Auxiliary coil 9 Transformer
4 Protector 10 Electrode
5 Frame grounding 11 Switch
6 Ground
R (Br)
W (L)
G (G/Y)
R (Br)
W (L)
G (G/Y)
R (Br)
W (L)
G (G/Y)
R
W
R
W
G
6
6
6
6
5
B
B
B
W
G
5
5
7
11
7
4
4
4
9
8
10
1
1
2
2
3
3
R (Br)
W (L)
G (G/Y)
G/Y
G/Y
B
B
5
11
4
1
2
3
1
2
3
PS2 800 PSW3 1500
PSA2 800
wc_gr005717
PS / PSA / PSW... Operation
wc_tx000989gb.fm 17
If connected to a circuit protected by a fuse, use a time-delay fuse with
this pump.
Wire Colors
B Black V Violet Or Orange
G Green W White Pr Purple
L Blue Y Yellow Sh Shield
P Pink Br Brown LL Light Blue
R Red Cl Clear G/Y Green/Yellow
T Tan Gr Gray
CAUTION
Operation PS / PSA / PSW...
wc_tx000989gb.fm 18
2.6 Operation
Before starting
2.6.1 Make sure once again that the product is of the correct voltage and
frequency rating.
NOTICE: Using the product at other than rated voltage and frequency
will not only lower its performance but may damage the product.
Note: Confirm the rated voltage and frequency on the model
nameplate.
2.6.2 Confirm the wiring, supply voltage, circuit breaker capacity, and motor
insulation resistance.
Reference insulation resistance = 20 MW or greater.
Note: The reference insulation resistance (20 MW or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation see “Periodic Maintenance Table.”
2.6.3 The setting on the circuit breaker or other overload protector should be
made in accord with the rated current of the pump.
Note: See “Operating Specifications” for the rated current of the pump.
2.6.4 When powering the pump with a generator, be certain the generator is
sized to supply the required power for the pump and any other
equipment powered by the generator.
Non-Automatic Models (PS2 800, PSW3 1500 )
Test Operation
Do not operate the pump while it is suspended in the air. The recoil
may result in injury or other major accident.
Do not start the pump when people are standing next to it. A current
leak can result in electrical shock.
Run the pump for a short time (3–10 minutes) and confirm the
following:
Using an ammeter (clamp-on type), measure the operating
current at the L1 and L2 phase wires on the terminal.
COUNTERMEASURE: If the operating current exceeds the rated
value, pump motor overload may be a cause. Make sure the pump has
been installed under proper conditions as described in Installation.
Using an AC voltmeter (tester), measure voltage at the terminals.
Supply voltage tolerance: within ±5% of rated voltage.
WARNING
WARNING
PS / PSA / PSW... Operation
wc_tx000989gb.fm 19
COUNTERMEASURE: If the supply voltage is outside the tolerance,
possible causes are the power supply capacity or an inadequate
extension cable. Look again at the wiring diagram and make sure the
conditions are proper.
In case of very excessive vibration, unusual noise or odor, turn off the
power immediately and consult your nearest dealer or Wacker
representative. Continuing to operate the pump under abnormal
conditions may result in electrical shock, fire, or current leakage.
Operation
Make sure no extraneous objects such as pins, nails or other metal
objects are sucked into the pump. These can damage the pump or
cause it to malfunction, and can result in electrical shock or electrical
leakage.
When the pump is not used for an extended period, be sure to turn off
the power (circuit breaker, etc.). Deterioration of the insulation may
lead to electrical leakage, electrical shock, or fire.
In case of a power outage, turn off the power to the pump to avoid
having it start unexpectedly when the power is restored, presenting
serious danger to people in the vicinity.
The pump may become hot during operation. Do not touch an
operating pump. Allow the pump to cool before handling.
Pay careful attention to the water level while the pump is operating. Dry
operation may cause the pump to malfunction.
Note: See section “Operating Water Level” for the water level
necessary for operation.
If the protection system operates due to an overload or malfunction,
causing the pump to stop, first investigate and remove the cause
before restarting.
CAUTION
WARNING
CAUTION
Operation PS / PSA / PSW...
wc_tx000989gb.fm 20
Operating water level
Do not operate the pump below the C.W.L. (Continuous running Water
Level) indicated below. Failure to observe this condition may result in
damage to the pump, current leakage or electrical shock.
See Graphic: wc_gr005720
Operating Water Level.
Pump Model C.W.L.
PS2 800 50 mm (2 in.)
PSA2 800 80 mm (3.15 in.)
PSW3 1500
CAUTION
PS2 800, PSA2 800
PSW3 1500
wc_gr005720
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

Wacker Neuson PSW31500 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues