The UV system should remain on continuously to ensure protection of your water system. During normal
operation of the system, the green power LED light will be illuminated and the display will indicate the number
of days remaining until lamp replacement is required.
'XULQJSHULRGVRIQRQXVHLWLVQRUPDOIRUWKHWHPSHUDWXUHRIWKHZDWHULQWKHF\OLQGHUWRULVH6LPSO\ÁXVKLQJ
the water line will alleviate this condition. During humid conditions, sweating, or small water droplets may
be noticed on the surface of the UV reaction chamber. The formation of condensation during high humidity
conditions is normal. Do not allow condensation to drip onto ballast or the Class A system OWL controller.
The following instructions have been provided to assist with general maintenance of the system; UV lamp
replacement and quartz sleeve cleaning/ replacement. All other system repairs must be completed by an
accredited service technician.
)RUV\VWHPUHSDLUVÀUVWFRQWDFW\RXUORFDOZDWHUWUHDWPHQWGHDOHUZKHUH\RXSXUFKDVHGWKLVSURGXFWRUDQ
accredited service technician by calling our Customer Service Center at 1-888-592-8370
WARNING: Never attempt to service the Vitapur
®
UV system unless you are an accredited service technician,
as the performance of the system could be adversely affected.
WARNING: The lamp heats up after continuous use and can burn your skin if touched. Allow lamp to cool for
at least 5 minutes before removing. Do not operate the UV lamp outside of the reactor. The lamp in the unit
emits powerful Ultraviolet light that can cause permanent damage to skin and eyes. Never look at the lamp
when the unit is turned on. Handle the UV lamp by the ends only. Do not touch the bulb of a lamp with your
ÀQJHUV,IWKHVXUIDFHRIWKHODPSEHFRPHVGLUW\XVHDFOHDQOLQWIUHHFORWKDQGLVRSURS\ODOFRKROWRUHPRYH
the dirt.
Your Vitapur
®
UV disinfection system is equipped with a visible / audible lamp failure indicator. In the event
RIDIDLOXUHRIWKH89ODPSWKHUHG/('OLJKWZLOOÁDVKDQGDORXGEHHSLQJZLOOEHDXGLEOHIURPWKHHOHFWURQLF
ballast of the unit. The lamp life countdown timer will stop decrementing. Please note that if these conditions
occur and you are on a non-municipal supplied water source, you should immediately stop using the water
for potable applications until the lamp is replaced and disinfection of the distribution lines is completed.
7KHXOWUDYLROHWODPSKDVDQDSSUR[LPDWHOLIHRIRQH\HDU+UV$OWKRXJKWKH89ODPSZLOOFRQWLQXHWR
operate long past 9000 hours, the UV output continually decreases after 9000 hours, and the UV lamp may
no longer provide adequate disinfection. The built in 365 day countdown timer displays the number of days
remaining until lamp replacement is required. When countdown timer reaches 0 days an intermittent audible
alarm will be activated and display will indicate alarm A3. In order to allow time to obtain a replacement
UV lamp, the audible alarm can be silenced for 7 days by pressing and holding button on ballast for 2-5
VHFRQGV$IWHUGD\VDODUPZLOOVRXQGDJDLQLIODPSKDVQRWEHHQUHSODFHG7KLVFDQEHGRQHDPD[LPXPRI
4 times which allows a total of 28 days to obtain a replacement UV lamp. After 4 times, alarm can no longer
be silenced until a replacement lamp is installed and the lamp life alarm is reset to 365 days by pressing and
holding button for 10 seconds.
Replacement UV lamps and quartz sleeves are available from an authorized dealer. Use only Vitapur
®
lamps
and sleeves to ensure system performance. Replacement lamps and quartz sleeves are sold under the
following model numbers:
OPERATION & MAINTENANCE:
LAMP INSTALLATION AND REPLACEMENT:
  • Page 1 1

vitapur GUVL-330S Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues