Beko BS 107 C Manuel utilisateur

Taper
Manuel utilisateur
Portable air
conditioner
User Manual
BS 107 C
EN FR
Please read this user manual rst!
Dear Customer,
Thank you for preferring a Beko product. We hope that you get the best results
from your product which has been manufactured with high quality and state-of-
the-art technology. Therefore, please read this entire user manual and all other
accompanying documents carefully before using the product and keep it as a
reference for future use. If you handover the product to someone else, give the user
manual as well. Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
This product has been produced in environmentally friendly, modern facilities
Complies with the WEEE Regulation. Does not contain PCB.
C
Important information or
useful hints about usage.
A
Warning for hazardous
situations with regard to
life and property.
Warning to actions that
must never perform.
B
Warning for electric shock.
This symbol shows that
this appliance used a
flammable refrigerant. If
the refrigerant is leaked
and exposed to an external
ignition source, there is a
risk of fire.
Warning for hot surfaces.
Do not cover it.
This symbol shows that the
operation manual should
be read carefully.
This symbol shows that a
service personnel should
be handling this equipment
with reference to the
installation manual.
Portable air conditioner / User Manuel
3 / 64 EN
CONTENTS
The refrigerant used in mobile air conditioners is the environmentally friendly hydrocarbon R290.
This refrigerant is odorless, and compared to the alternative refrigerant, the R290 is an ozone-free
refrigerant, and its effect is very low.
Please read the instructions before use and repair.
The drawings provided in this manual may not be the same as the physical objects. Please refer to the
physical objects.
1 Safety nstructons 4
2 Features and components 10
2.1 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Control settng 12
3.1 Control panel operation instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.2 Operation instructions of remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Protecton functon 15
5 Installaton and adjustment 16
5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Dranage nstructons 19
7 Mantenance 21
7.1 Clean the surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.2 Clean the lter screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.3 Clean the upper lter screen frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
8 Unt Storage 22
9 Troubleshootng 23
10 Addendum 30
11 Installaton nstructons 31
11.1 F-Gas instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
12 Specfcatons 32
4 / 64 EN
Portable air conditioner / User Manuel
Warnng matters:
Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an operating
gas appliance or an operating electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Appliance shall be installed, operated and stored in a room with a
floor area larger than 7 m
2
The appliance must be kept free from obstruction to ensure proper
function and mitigate safety hazards.
Servicing shall be performed only as recommended by the
manufacturer.
The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorises their
competence to handle refrigerants safely in accordance with an
industry recognised assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.
1 Safety nstructons
Portable air conditioner / User Manuel
5 / 64 EN
1 Safety nstructons
All working procedure that affects safety means shall only be
carried by competent persons.
C
Note:
The air conditioning is only suitable for indoor use, and is
not suitable for other applications.
Follow local grid interconnection rules while installing the
air conditioning and ensure that it is properly grounded.
If you have any question on electrical installation, follow
the instructions of the manufacturer, and if necessary,
ask a professional electrician to install it.
Place the machine in a flat and dry place and keep a
distance of above 50cm between the machine and the
surrounding objects or walls.
After the air conditioning is installed, ensure that the
power plug is intact and firmly plugged into the power
outlet, and place the power cord orderly to prevent
someone from being tripped or pulling out the plug.
Do not put any object into the air inlet and outlet of the
air conditioning. Keep the air inlet and outlet free from
obstructions.
When drainage pipes are installed, ensure that the
drainage pipes are properly connected, and are not
distorted or bended.
While adjusting the upper and lower wind-guide strips
of the air outlet, pluck it with hands gently to avoid
damaging wind-guide strips.
6 / 64 EN
Portable air conditioner / User Manuel
C
Note:
When moving the machine, make sure that it is in an
upright position.
The machine should stay away from gasoline, flammable
gas, stoves and other heat sources.
Don’t disassemble, overhaul and modify the machine
arbitrarily, otherwise it will cause a machine malfunction
or even bring harm to persons and properties. To avoid
danger, if a machine failure occurs, ask the manufacturer
or professionals to repair it.
Do not install and use the air conditioning in the
bathroom or other humid environments.
Do not pull the plug to turn off the machine.
Do not place cups or other objects on the body to
prevent water or other liquids from spilling into the air
conditioning.
Do not use insecticide sprays or other flammable
substances near the air conditioning.
Do not wipe or wash the air conditioning with chemical
solvents such as gasoline and alcohol. When you need
to clean the air conditioning, you must disconnect the
power supply, and clean it with a half-wet soft cloth. If
the machine is really dirty, scrub with a mild detergent.
1 Safety nstructons
Portable air conditioner / User Manuel
7 / 64 EN
C
Note:
This appliance can be used by children aged from
8 years and above if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understand the hazards involved. Cleaning and user
maintenance shall not be made by children unless they
are aged from 8 years and above and supervised. Keep
the appliance and its cord out of reach of children aged
less than 8 years.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The appliance shall be installed in accordance with
national wiring regulations.
Do not operate your air conditioner in a wet room such as
a bathroom or laundry room.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
1 Safety nstructons
8 / 64 EN
Portable air conditioner / User Manuel
C
Warning Do not use manuals to accelerate the defrosting
process or to clean, other than those recommended by
the manufacturer. The appliance shall be stored in a
room without Continuously operation ignition sources
(for example: open flames, an operation gas appliance or
an operating electric heater.) Do not pierce or burn. Be
aware that refrigerants may not contain an odour.
The appliance shall state the insulation of a residual
current device (RCD) having rated residual operating
current not exceeding 30mA.
This appliance is intended to be used in household and
similar applications such as
-
Staff kitchen areas in shops, offices and other working
environments;
-
farm houses;
-
by clients in hotels, motels and other residential type
environments;
-
bed and breakfast type environments;
1 Safety nstructons
Portable air conditioner / User Manuel
9 / 64 EN
Transportaton, markng and storage for unts
Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
Marking of equipment using signs
Compliance with local regulations
Disposal of equipment using flammable refrigerants
Compliance with national regulations
Storage of equipment/appliances
The storage of equipment should be in accordance with the
manufacturer’s instructions.
Storage of packed (unsold) equipment
Storage package protection should be constructed such that
mechanical damage to the equipment inside the package will not
cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
1 Safety nstructons
10 / 64 EN
Portable air conditioner / User Manuel
2.1 Features
Brand new appearance, compact structure, smooth line, simple and generous shape.
Functions of refrigeration, dehumidification, air supply and continuous drainage
Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe.
LED displays the control panel, beautiful and fashionable, with high-quality remote control. It adopts a
user-friendly remote control design.
Air filtration capability.
Timing switch function.
Protection function of automatically restarting the compressor after three minutes, a variety of other
protection functions.
The Max operation temperature for the air conditioner Cooling: 35/24°C; heating:20/12 °C;
Temperature operation range: 7-35°C.
2.2 Components
Control panel
Top cover
Rear housing
Handle
Caster
Air outlet/Louver
Front housing
2 Features and components
Portable air conditioner / User Manuel
11 / 64 EN
Front housing
Handle
Rear housing
EVA filter
Continuous
drainage hole
Air vent
CON filter
Drainage hole
Exhaust pipe assembly
Window sealing plate assembly
2 Features and components
12 / 64 EN
Portable air conditioner / User Manuel
3.1 Control panel operaton nstructons
Operaton nterface
1 2 3 4 5 6 7
1. Timer key
2. Up key
3. Down key
4. Display window
5. Fan speed selection key
6. Mode selection key
7. Power key
1. When the machine is powered on for the first time, the buzzer will play power-on music, and then
the machine will get into standby status.
2.
Power Key: press the key to turn on and turn off the machine. In the case of power on, press the
key to turn off the machine; in the case of power off, press the key to turn on the machine.
3.
Mode Selection Key: In the case of power on, press the key to switch between cooling fan
dehumidifying mode.
4.
Up Key and Down Key: press the two keys to change the setting temperature or setting time,
operate as follows:
While setting temperature, press up key or down key to select the required temperature (not
available in fan or dehumidifying mode).
3 Control settng
Portable air conditioner / User Manuel
13 / 64 EN
While setting time, press up key or down key to select the required time.
5.
Wind Speed Selection Key:
In cooling and fan mode, press the key to select high,low wind speed operation. But limited by anti-
cold conditions, under certain conditions, it may not run according to the set wind speed.
In dehumidifying mode, pressing the key is invalid, and the fan will forcibly choose low wind speed
operation.
6.
Timing Key:
In the case of power on, press the key to close timing; in the case of power off, press the key to
open timing.
Press the key, when the timing symbol flashes, press up and down key to select the required timing
value.
Timing values can be set in 1-24 hours and the timing value is adjusted up or down by one hour.
7.
Sleep Mode:
In the cooling Mode,Press the UP and Fan Key to turn on the sleep mode, then the unit will work on
Energy-Saving and quiet type.
3.2 Operaton nstructons of remote control
The remote control Panel is as follows:
1
2
3
4
5
7
6
3 Control settng
14 / 64 EN
Portable air conditioner / User Manuel
Instructions of key operation of the high-quality remote control are as follows:
1. Power: press the key to turn on or turn off the machine.
2. Timer: press the key to set timing.
3. Down: press the key to reduce temperature and timing set value.
4. Mode: press the key to switch between cooling, fan, dehumidifying mode.
5. Up: press the key to increase temperature and timing set value.
6. Fan: press the key to select high, low wind speed.
7. Sleep mode: press the key to turn on the sleep mode.
3 Control settng
Portable air conditioner / User Manuel
15 / 64 EN
1. Frost Protecton Functon
In cooling, dehumidifying or economic power saving mode, if the temperature of the exhaust pipe is
too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe
rises to a certain temperature, it can automatically revert to normal operation.
2. Overflow Protecton Functon
When water in the water pan exceeds the warning level, the machine will automatically sound an
alarm, and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe
connecting the machine or the water outlet to sewer or other drainage area to empty the water
(details see Drainage Instructions at the end of this chapter). After the water is emptied, the machine
will automatically return to the original state.
3. Automatc Defrostng (Heat pump models have ths functon.)
The machine has automatic defrosting function. Defrosting can be achieved through four - way valve
reversing.
4. Protecton Functon of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function
after the compressor is turned off.
4 Protecton functon
16 / 64 EN
Portable air conditioner / User Manuel
5.1 Installaton
A
Warnng: before using the mobile air conditioning, keep it upright for at least
two hours.
The air conditioning can be easily moved in the room. In the moving process, ensure that the air
conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do
not install and use the air conditioning in the bathroom or other humid environments.
1. Install the heat pipe assembly (as shown in Fig. 1)
Push
Fig. 1
1) Take out the outer connector assembly and the exhaust pipe assembly, and remove the plastic
bags;
2) Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot (push to
the left) and complete the assembly (as shown in fig. 1).
2. Installation of window sealing plate components
1) Half open the window, and mount the window sealing plate assembly to the window (as shown in
Fig. 2 and Fig. 3). Components can be placed in horizontal and vertical direction.
2) Pull various components of the window sealing plate assembly open, adjust their opening distance
to bring both ends of the assembly into contact with the window frame, and fix various components
of the assembly.
5 Installaton and adjustment
Portable air conditioner / User Manuel
17 / 64 EN
C
Note:
1. The flat end of the exhaust pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep
the ventilation of the exhaust pipe not blocked.
Fig. 2 Fig. 3
3. Install the body
1) Move the machine with installed heat pipe and fittings before the window, and the distance
between the body and walls or other objects shall be least 50 cm (as shown in Fig. 4).
Min: 50cm
Min: 50cm
Fig. 4
2) Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the
window sealing plate assembly (as shown in Fig. 5 and Fig. 6) .
5 Installaton and adjustment
18 / 64 EN
Portable air conditioner / User Manuel
C
Note:
1. The flat end of the exhaust pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep
the ventilation of the exhaust pipe not blocked.
Fig. 5 Fig. 6
C
Important notce:
The length of the exhaust hose shall be 280~1,500mm, and this length is based on
the specifications of the air conditioning. Do not use extension tubes or replace it
with other different hoses, or this may cause a malfunction. Exhaust host must be not
blocked; otherwise it may cause overheating.
5 Installaton and adjustment
Portable air conditioner / User Manuel
19 / 64 EN
This machine has two drainage methods: manual drainage and continuous drainage.
1. Manual drainage:
1) When the machine stops after the water is full, turn off the machine power and unplug the power
plug.
C
Note: Please move the machine carefully, so as not to spill the water in the water pan
at the bottom of the body.
2) Place the water container below the side water outlet behind the body.
3) Unscrew the drainage cover and unplug the water plug, the water will automatically flow into the
water container.
C
Note:
1. Keep the drainage cover and the water plug properly.
2. During drainage, the body can be tilted slightly backwards.
3. If the water container cannot hold all the water, before the water container is full,
stuff the water outlet with the water plug as soon as possible to prevent water from
flowing to the floor or the carpet.
4. When the water is discharged, stuff the water plug, and tighten the drainage cover.
6 Dranage nstructons
20 / 64 EN
Portable air conditioner / User Manuel
2. Continuous drainage (Optional) (only applicable to dehumidifying mode), as shown in figure:
1) Unscrew the drainage cover, and unplug the water plug.
2) Set the drainage pipe into the water outlet.
3) Connect the drainage pipe to the bucket.
6 Dranage nstructons
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Beko BS 107 C Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues