AEG BS7304001M Guide d'installation

Taper
Guide d'installation
INS TAL LAT ION
EN
Installation Instruction
Warning! Before proceeding with installation, read
the safety information in the User Manual.
The oven is designed to be connected to 230 - 240V
~ (50Hz) electricity supply.
The oven has an easily accessible terminal block which
is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical
VXSSO\PXVWFRPSO\WRWKHVSHFL¿FDWLRQVJLYHQEHORZ
For UK use only
Connection
via
Min. size
&DEOHÀH[
&DEOHÀH[
type
Fuse
Cooker
Control
Circuit
2,5 mm² PVC / PVC
twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3 mm between the switch
contacts and of a type suitable for the required load in
compliance with the current regulations.
The switch must not break the yellow and green earth
cable at any point.
EN
After installation and connecting, the cable must
be placed so that it cannot at any point reach
a temperature of more than 50°C above the
ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply is
properly earthed.
The manufacturer declines any responsibility
should these safety measures not be carried out.
Attention: The new appliance may only be installed and
connected by a registered expert.
Please comply with this. If you do not, any
damage resulting is not covered by the warranty.
Safety information for the installer
 7KHHOHFWULFDOLQVWDOODWLRQLVWREHVHWXSVR
that the appliance can be isolated from the
mains with a minimum 3 mm all-pole contact
separation.
 6XLWDEOHVHSDUDWLRQGHYLFHVLQFOXGHHJ
cut-outs, fuses (screw fuses are to be taken
out of the holder), RCD’s and ccontactors.
 $QWLVKRFNSURWHFWLRQPXVWEHSURYLGHGE\WKH
installation.
 7KHEXLOWLQXQLWPXVWPHHWWKHVWDELOLW\
requirements of DIN 68930.
 %XLOWLQRYHQVDQGEXLOWLQFRRNLQJVXUIDFHV
DUH¿WWHGZLWKVSHFLDOFRQQHFWLRQV\VWHPV)RU
safety reasons, they must only be combined
with appliances from the same manufacturer.
2
min.
3 mm
3
min.
50 mm
=
=
4
min. 550
20
594
15
579
590
min. 560
594
589
114
21546
548
3
5
594
15
579
594
589
114
21546
min. 550
20
600
min. 560
548
3
5
5
130
max. R1200 mm
140
alternativ 100
H05VV-F
H05RR-F
min. 1600 mm
90°
2x3,5x25
6
7
867302060-C-072016
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AEG BS7304001M Guide d'installation

Taper
Guide d'installation

dans d''autres langues