Airmax LR25 Installation & Maintenance

Taper
Installation & Maintenance

Ce manuel convient également à

Pond
&
Lake
Installation & Maintenance
For Models:
Airmax® Ecosystems
Natural. Clear Water. Guaranteed.™
www.airmaxeco.com
Airmax® Ecosystems
Natural. Clear Water. Guaranteed.™
www.airmaxeco.com
WARRANTY:
Airmax® Ecosystems will repair or replace any SilentAir™ LR Series compressor found to be defective within 2 years
of the original purchase date. Air filters and diaphragms are considered wear items and are not covered by this warranty.
This limited warranty is extended exclusively to the original purchaser beginning from the date of original receipt. Abuse or
misuse of this product voids all warranty. Any signs of water damage inside the unit voids all warranty. In case of warranty
claims, the product must be returned to place of purchase accompanied by original receipt.
REPLACEMENT PARTS
SILENTAIR™
COMPRESSOR
DIAPHRAGM
KIT
AIR
FILTERS*
LR25 #510147 #510158
LR50 #510148 #510159
* Package contains two replacement air filters.
Only one required per pump.
4
SilentAir
LR Series
Compressors for Shallow Water Aeration Systems
2YE AR WARR ANT Y
• LR25
(Item #120912)
• LR50
(Item #120913)
NOTE: Airline and Diuser NOT Included
Use with ProAir
2 Diuser (Item #490354)
and EasySet
Weighted Airline
(Item #510118) for the best results.
073_12
AIR FILTER
AIR FILTER COVER
DIAPHRAGM KIT
COVER LID
CAUTION: To reduce the risk of electric shock, pull plug before
servicing this pump.
WARNING: Risk of electrical shock, this compressor has not
been investigated for use in swimming pool areas. This pump is
supplied with a grounded plug. To reduce the risk of electric shock:
connect only to a properly grounded receptacle which is serviced
by a Ground Fault Interrupter.
• Do not place pump where it
might fall into water.
• Do not place pump
in direct sunshine.
• Do not place pump near
ammable or other dangerous
materials or objects.
• Use only to pump air.
• Place horizontally and make
sure pump is above the height
of the water surface to prevent
water siphoning out of pond.
WARNING
!
ATTENTION: Pour réduire le risque de choc électrique,
débrancher la pompe avant de réparer cette pompe.
AVERTISSEMENT: Rish de choc électrique, cette pompe n’a
pas été étudié pour une utilisation dans les piscines. Cette pompe
est fournie avec une prise de terre. Pour réduire le risque de choc
électrique: se connecter uniquement à une prise correctement mise à
la terre qui est desservi par un disjoncteur de fuite à la terre.
• Ne pas placer la pompe où elle
pourrait tomber dans l’eau.
• Ne pas placer la pompe
en plein soleil.
• Ne pas placer la pompe près de
substances inammables ou
autres matières dangereuses ou
des objets.
• Utiliser uniquement pour
pompe à air.
• Placer horizontalement et
s’assurer que la pompe est
supérieure à la hauteur de la
surface de l’eau pour empêcher
l’eau de l’étang à siphonner.
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To guard against injury, basic safety precautions should be observed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment.
For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility
for service or discard the appliance:
1. If the appliance falls into the water, DON’T reach for it!
First unplug it and then retrieve it. If electrical compo-
nents of the appliance get wet, unplug the appliance
immediately.
2. Carefully examine the appliance after installation. It
should not be plugged in if there is water on parts not
intended to be wet.
3. Do not operate any appliance plug or receptacle getting
wet, position aquarium stand and tank to one side of
a wall-mounted receptacle to prevent water from drip-
ping onto the receptacle or plug. A “drip loop” should
be arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip loop” is
that part of the cord below the level of the receptacle,
or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the
receptacle. If the plug or receptacle does get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to the appliance. Then, unplug and examine for presence of water in the receptacle.
c. Close supervision is necessary when any appliance is used by or near children.
d. To avoid injury, do not contact moving parts.
e. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning.
never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
f. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition.
g. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
h. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less ampreres or watts tan
the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
This appliance should be grounded to minimize the possibility of electric shock. This appliance is equipped with an electric
cord having an equipment grounding conductor and a grounding type plug. The plug must be plugged into an outlet that
is installed and grounded in accordance with all appropriate codes and ordinances.
The appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in (A)
above. A temporary adapter which looks like the adapter illustrated in (B) and (C) above may be used to connect this plug
to a two-pole receptacle as shown in (B) if a grounded outlet is not available. The temporary adapter should be used only
until a grounded outlet can be installed by a qualified electrician. The green-colored rigid ear( lug, and the like) extending
from the adapter must be fastened to a permanent ground such as a grounded outlet box.
IMPORTANT: Airmax® Ecosystems, Inc. is not responsible for losses, injury or death resulting from a failure to follow these
safety precautions, misuse or abuse of equipment.
TECHNICAL SPECS
MODEL VOLTAGE WATTAGE
MAX
AIR FLOW
MAX DIFFUSER
DEPTH
ITEM #
LR25 120V / 60 Hz 50 Watts 2.5 CFM Up to 6 Feet 120912
LR50 120V / 60 Hz 100 Watts 4.9 CFM Up to 8 Feet 120913
INSTALLATION
Compressors should be installed 12 inches or more above the water level to ensure that water cannot flow from the airline/
diffuser back to the pump. Compressors may be used without protection although for longer life it is suggested that it be
placed indoors or under a protective ventilated cover. Keep pump as dry as possible. If left outdoors place it on a hard
surface that will stay dry during heavy rains.
MAINTENANCE & TROUBLESHOOTING
There are no parts that need lubrication. The integrated air filter requires periodic cleaning. To clean the filter media, remove
the air filter cover. Extract the filter media from the compressor and rinse thoroughly with cold water. Before replacing, wait
for the air filter to dry. Replace media into the empty filter cavity, replace the air filter cover and refasten. When the airflow
decreases, it is time to replace the diaphragms. There are two diaphragms, one at either end of the compressor.
1. Disconnect the compressor from the AC receptacle.
2. Remove the cover lid.
3. Unscrew the diaphragm assembly from either end of the compressor.
4. Remove the diaphragm assembly.
5. Replace the diaphragm assembly and refasten.
6. Replace the cover lid.
32
SilentAir
LR Series
Compressors for Shallow Water Aeration Systems
Installation & Maintenance Instructions
Pond
&
Lake
  • Page 1 1
  • Page 2 2

Airmax LR25 Installation & Maintenance

Taper
Installation & Maintenance
Ce manuel convient également à

dans d''autres langues