Weller WXHAP 200 Operating Instructions Manual

Taper
Operating Instructions Manual
WXHAP 200
Betriebsanleitung - Operating Instructions - Mode dèmploi - Istruzioni per lùso - Manual de uso -
Manual do utilizador - Gebruiksaanwijzing - Instruktionsbok - Betjeningsvejledning - Käyttöohjeet -
Οδηγίες Λειτουργίας- Kullanım kılavuzu - Návod k použití - Instrukcja obsługi - Üzemeltetési utasítás
Návod na používanie - Navodila za uporabo - Kasutusjuhend - Lietosanas instrukcija –
Naudojimo instrukcija
WXHAP 200 – Operating Instructions I
The data specified above only serve to
describe the product. No statements
concerning a certain condition or suitability for
a certain application can be derived from our
information. The given information does not
release the user from the obligation of own
judgement and verification. It must be
remembered that our products are subject to a
natural process of wear and aging.
© This document, as well as the data,
specifications and other informations set forth
in it, are the exclusive property of Weller Tools
GmbH. Without their consent it may not be
reproduced or given to third parties. Subject to
modifications.
Printed in Germany.
05.2013
Deutsch
DE
English
EN
Français
FR
Italiano
IT
Español
ES
Português
PT
Nederlands
NL
Svenska
SV
Dansk
DK
Suomi
FI
Eλληvık
GR
Türkçe
TR
Česky
CZ
Polski
PL
Magyar
HU
Slovensky
SK
Slovenščina
SL
Saksa keel
EE
Lietuviškal
LV
Vāciski
LT
WXHAP 200 – Operating Instructions II
български
BG
Român
RO
Hrvatski
HR
EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
DE
WXHAP 200
Betriebsanleitung
WXHAP 200
WXHAP 200
Geräteübersicht
1 Elektrisches Anschlusskabel
2 Anschluss Heißluftschlauch
3 Fingerschalter
4 Ablage
5 Düsenadapter
6 Düse
Legen Sie das Lötwerkzeug bei
Nichtgebrauch immer in der
Sicherheitsablage ab.
4
WXHAP 200 3-6
DE
DE
FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Inhalt
1
Zu dieser Anleitung .................................................................... 3
2 Zu Ihrer Sicherheit ..................................................................... 3
3 Lieferumfang (Betriebsanleitung) ............................................... 4
4. Gerätebeschreibung ................................................................... 4
4 Inbetriebnahme des Geräts ....................................................... 5
5 Zubehör ..................................................................................... 6
6 Entsorgung ................................................................................ 6
7 Garantie ..................................................................................... 6
1 Zu dieser Anleitung
Wir danken Ihnen für das mit dem Kauf des Weller Heißluftkolbens
WXHAP 200 erwiesene Vertrauen. Bei der Fertigung wurden
strengste Qualitätsanforderungen zugrunde gelegt, die eine
einwandfreie Funktion des Gerätes sicherstellen.
Diese Anleitung enthält wichtige Informationen, um den WXHAP 200
sicher und sachgerecht in Betrieb zu nehmen, zu bedienen, zu
warten und einfache Störungen selbst zu beseitigen.
Z Lesen Sie diese Anleitung und die beiliegenden
Sicherheitshinweise vor Inbetriebnahme des WXHAP 200
vollständig durch, bevor Sie mit dem WXHAP 200 arbeiten.
Z Bewahren Sie diese Anleitung so auf, dass sie für alle Benutzer
zugänglich ist.
1.1 Berücksichtigte Richtlinien
Der Weller Heißluftkolben WXHAP 200 entspricht den Angaben der
EG Konformitätserklärung mit den Richtlinien 2004/108/EG
2006/95/EG und 2011/65/EU (RoHS).
1.2 Zu beachtende Dokumente
Betriebsanleitung des WXHAP 200
Begleitheft Sicherheitshinweise zu dieser Anleitung
Betriebsanleitung Ihres Steuergeräts
2 Zu Ihrer Sicherheit
Der Heißluftkolben WXHAP 200 wurde entsprechend dem heutigen
Stand der Technik und den anerkannten sicherheitstechnischen
Regeln hergestellt. Trotzdem besteht die Gefahr von Personen- und
Sachschäden, wenn Sie die Sicherheitshinweise im beiliegenden
Sicherheitsheft sowie die Warnhinweise in dieser Anleitung nicht
beachten. Geben Sie den WXHAP 200 an Dritte stets zusammen mit
der Betriebsanleitung weiter.
4-6 WXHAP 200
2.1 Das müssen Sie beachten
Legen Sie den Heißluftkolben stets in der Originalablage ab.
Entfernen Sie alle brennbaren Gegenstände aus der Nähe des
heißen Lötwerkzeugs.
Schließen Sie niemals brennbare Gase an Ihre Heißluftgeräte an.
Tragen Sie geeignete Schutzkleidung beim Betrieb des
WXHAP 200.
Richten Sie den Heißluftstrahl nicht auf Personen und schauen
Sie nicht in den Heißluftstrahl hinein.
Lassen Sie den heißen WXHAP 200 nie unbeaufsichtigt.
Arbeiten Sie nicht an unter Spannung stehenden Teilen.
Sorgen Sie bei der Verwendung von inerten Gasen für
ausreichende Belüftung.
Lesen und beachten Sie die Betriebsanleitung der jeweiligen
verwendeten Weller WXA 2 Versorgungseinheit.
2.2 Bestimmungsgemäßer Gebrauch
Verwenden Sie den WXHAP 200 ausschließlich gemäß dem in der
Betriebsanleitung angegebenen Zweck zum Löten und Entlöten von
oberflächenmontierten Bauelementen unter den hier angegebenen
Bedingungen. Der bestimmungsgemäße Gebrauch des WXHAP 200
schließt auch ein, dass
Sie diese Anleitung beachten,
Sie alle weiteren Begleitunterlagen beachten,
Sie die nationalen Unfallverhütungsvorschriften am Einsatzort
beachten.
Für andere von der Betriebsanleitung abweichende Verwendung,
sowie bei eigenmächtig vorgenommenen Veränderungen am Gerät
wird vom Hersteller keine Haftung übernommen.
3 Lieferumfang (Betriebsanleitung)
WXHAP 200
T0052712099
WDH 30
T0051515299
R04 Ø 1,2 mm
R06 Ø 3,0 mm
Düsenadapter M6
WXHAP 200 5-6
DE DE FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
4. Gerätebeschreibung
Der Weller Heißluftkolben WXHAP 200 mit integriertem
Fingerschalter (3) eignet sich zum Löten und Entlöten von
oberflächenmontierten Bauelementen. Ein breites Düsenprogramm
macht ihn universell einsetzbar. Durch den im Handgriff integrierten
Fingerschalter (3) wird der Luftdurchfluss gesteuert. Die Ionenfalle
im Kolben sorgt dafür, dass die ausströmende Heißluft frei von
statischen Ladungen ist. Schlauch und Handgriff sind antistatisch
ausgeführt. Die Temperatur der Heißluft kann über das Steuergerät
im Bereich von 50 °C – 550 °C (100 °F – 1000 °F) eingestellt
werden.
3.1 Technische Daten WXHAP 200
Heizleistung 200 W
Heizspannung 24 V AC
Max. Luftmenge 15 l/min
Temperaturbereich 50 °C bis 550 °C/100 °F bis 1000 °F
Temperaturgenauigkeit ± 30
°C/± 80 °F
Potentialausgleich
Der Heißluftkolben WXHAP 200 ist mit einer
Potentialausgleichsleitung ausgestattet, die gemäß der
Betriebsanleitung des verwendeten Steuergeräts beschaltet werden
kann.
4 Inbetriebnahme des Geräts
WARNUNG!
Verletzungsgefahr durch Heißluft und inerte Gase.
Beim Betrieb des Heißluftkolbens besteht Verbrennungsgefahr
durch austretende Heißluft. Vorsicht: Bei Verwendung von inerten
Gasen besteht Erstickungsgefahr.
Z Lesen Sie die beiliegenden Sicherheitshinweise, die
Sicherheitshinweise in dieser Betriebsanleitung sowie die
Anleitung Ihres Steuergeräts vor in Inbetriebnahme des
WXHAP 200 vollständig durch. Beachten Sie die darin
gegebenen Vorsichtsmaßnahmen.
1. Den Heißluftkolben WXHAP 200 sorgfältig auspacken.
2. Sicherstellen, dass das Steuergerät ausgeschaltet ist.
3. Den Heißluftkolben WXHAP 200 in der Sicherheitsablage (4)
ablegen.
4. Den elektrischen Anschlussstecker (1) des WXHAP 200 in die
Anschlussbuchse des Steuergeräts einstecken und durch kurze
Rechtsdrehung verriegeln.
5. Die Schlauchleitung des WXHAP 200 (2) auf den „Air"-Nippel des
Steuergeräts schieben.
6-6 WXHAP 200
6. Steuergerät am Netzschalter einschalten und Temperatur und
Luftdurchflussmenge einstellen.
Beachten Sie hierbei die Betriebsanleitung Ihres Steuergeräts.
4.1 Arbeitshinweise
VORSICHT!
Beschädigung des Kolbenheizkörpers durch zu
langes Düsengewinde.
Die Gewindetiefe für Heißluftdüsen beträgt max. 5 mm (0,2 "). Ein
längeres Gewinde führt zur Zerstörung des Heizkörpers.
Die Verwendung von Düsen anderer Hersteller als Weller kann zu
Schäden am Heißluftkoben führen. Hierbei erlischt der
Garantieanspruch.
Z Achten Sie auf die richtige Gewindetiefe der
einzuschraubenden Düsen!
Z Verwenden Sie Weller Originalheißluftdüsen!
Mit dem WXHAP 200 erhalten Sie einen SW8 Steckschlüssel.
Dieser muss verwendet werden, um die Düsen zu wechseln. Ziehen
Sie die Muttern am Heizkörper mit dem mitgelieferten Maulschlüssel
fest.
Hinweis Um die Düsen zu verwenden den mitgelieferten Düsenadapter (5)
(T005 87 617 28) mit dem SW8 Steckschlüssel in den WXHAP 200
einschrauben. (siehe Überblick Hot Air Nozzles).
Ersatzheißluftkolben sind justiert und können ohne Nachjustierung
angeschlossen und verwendet werden.
Zur Überprüfung der Heißlufttemperatur wird die Verwendung einer
speziellen Messdüse (T005 87 278 08) empfohlen, durch die ein
Mantelthermoelement (Ø 0,5 mm) kontaktiert werden kann.
5 Zubehör
WXHAP 200 Heißluftdüsen (siehe Überblick Hot Air Nozzles).
6 Entsorgung
Entsorgen Sie ausgetauschte Geräteteile, Filter oder alte Geräte
gemäß den Vorschriften Ihres Landes.
7 Garantie
Die Mängelansprüche des Käufers verjähren in einem Jahr ab
Ablieferung an ihn. Dies gilt nicht für Rückgriffsansprüche des
Käufers nach §§ 478, 479 BGB.
Aus einer von uns abgegebenen Garantie haften wir nur, wenn die
Beschaffenheits- oder Haltbarkeitsgarantie von uns schriftlich und
unter Verwendung des Begriffs „Garantie“ abgegeben worden ist.
Technische Änderungen vorbehalten!
Die aktualisierten Betriebsanleitungen finden Sie unter
www.weller-tools.com.
EN
FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT DE
WXHAP 200
Operating Instructions
WXHAP 200
WXHAP 200
Device overview
1 Connector with cable
2 Hot air hose connection
3 Push button
4 Stand
5 Nozzle adaptor
6 Nozzle
Always place the soldering
tool in the safety rest while not
in use.
4
WXHAP 200 3-7
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
Contents
1
About these instructions ............................................................ 3
2 For your safety ........................................................................... 3
3 Scope of supply (Operating instructions) ................................... 5
4 Device description ..................................................................... 5
5 Commissioning the device ......................................................... 6
6 Accessories ............................................................................... 7
7 Disposal ..................................................................................... 7
8 Warranty .................................................................................... 7
1 About these instructions
Thank you for placing your trust in our company by purchasing the
Weller WXHAP 200 Hot Air Tool. This product meets or exceeds the
requirements established by Weller for superior performance,
versatility and quality.
These instructions contain important information which will help you
to start up, operate and service the WXHAP 200 safely and
correctly, as well as to eliminate simple faults/malfunctions
yourselves.
Z Please read these instructions carefully and the attached safety
guidelines before you put the WXHAP 200 into operation.
Z Keep these instructions in a place that is accessible to all users.
1.1 Directives taken into consideration
The Weller WXHAP 200 Hot Air Tool corresponds to the EC
Declaration of Conformity in accordance with the basic safety
requirements of Directives 2004/108/EC, 2006/95/EC and
2011/65/EU (RohS).
1.2 Applicable documents
WXHAP 200 operating instructions
Accompanying booklet on safety
Operating instructions for your control unit
2 For your safety
The WXHAP 200 Hot Air Tool has been manufactured in accordance
with state-of-the-art technology and recognized safety rules and
regulations. There is nevertheless the risk of personal injury and
damage to property if you fail to observe the safety information set
out in the enclosed booklet accompanying these operating
instructions and the warnings given therein.
4-7 WXHAP 200
Always pass on the WXHAP 200 on to third parties along with these
operating instructions. The manufacturer shall not be liable for
damage resulting from misuse of the machine or unauthorized
alterations
State of California warning:
When used for soldering and similar applications, this product
produces chemicals known to the State of California to cause
cancer and birth defects or other reproductive harm.
2.1 Please observe the following:
Always place the hot air tool in its original stand.
Remove all flammable objects from the vicinity of the hot soldering
tool.
Do not connect flammable gases to your hot air equipment.
Always wear suitable protective clothing when using the
WXHAP 200.
Do not direct the hot air jet at persons or look into the hot air jet.
Never leave the hot WXHAP 200 unattended.
Do not carry out work on live parts
When using inert gases, make sure the area is well ventilated.
Read and observe the operating instructions of your control unit.
Read and follow the operating instructions for the Weller WXA 2
supply unit.
2.2 Intended use
Use the WXHAP 200 exclusively for the purpose indicated in the
operating instructions of releasing, accommodating and setting down
chip components under the conditions specified here. Intended use
of the WXHAP 200 also includes that
you read and follow these instructions,
you read and follow all additional accompanying documents,
you observe the national accident-prevention regulations
applicable at the location where the device is used.
The manufacturer accepts no liability for damages resulting from
failure to use the device in compliance with these operating
instructions or unauthorised modifications to the device.
WXHAP 200 5-7
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
3 Scope of supply (Operating instructions)
4 Device description
The Weller WXHAP 200 Hot Air Tool with integrated finger switch (3)
is suitable for soldering and desoldering surface-mounted
components. A wide range of nozzles adds to the versatility of the
WXHAP 200 tool.
A push button (3) integrated in the handle is used to control the air
flow. The ionising circuit integrated in the tool ensures that hot air is
static free. The hose and handle are of antistatic design.
The hot air temperature can be set to between 50°C and 550°C
(100°F and 1000°F) using the control unit.
4.1 Technical data WXHAP 200
Heating output 200 W
Heating voltage 24 V AC
Max. air flow rate 15 l/min
Temperature range 50°C up to 550°C/100°F up to
1000°F
Temperature accuracy ± 30°C/± 80°F
Potential balance
The WXHAP 200 hot air tool has an equipotential bonding conductor
which can be connected in accordance with the operating
instructions of the control unit in use.
WXHAP 200
T0052712099
WDH 30
T0051515299
R04 Ø 1,2 mm
R06 Ø 3,0 mm
Nozzle adaptor M6
6-7 WXHAP 200
5 Commissioning the device
WARNING!
Risk of injury due to hot air and inert gases.
Use caution when operating the hot air tool, because hot air can
cause burns. Caution: use of inert gases in an enclosed area can
cause asphyxiation.
Z Please read carefully the safety instructions in the attached
booklet, the safety guidelines given in these operating
instructions and the operating instructions of your control unit
before putting the WXHAP 200 into operation. Also observe
the safety precautions described herein.
1. Carefully unpack hot air tool WXHAP 200.
2. Make sure that the control unit is OFF.
3. Place the WXHAP 200 hot air tool into the stand (4).
4. Insert the electrical plug (1) of the WXHAP 200 into the
socket on the control unit and lock the plug into place by turning it
slightly to the right.
5. Push the air hose of the WXHAP 200 (2) onto the air nipple on
the control unit.
6. Turn on the control unit at the power switch and set the
temperature and air flow. Also read and observe the operating
instructions of your control unit.
5.1 Operating guidelines
CAUTION!
Excessively long nozzle threads can damage the
heater core of your tool.
The max. thread depth for hot air nozzles is 5 mm (0.2 "). Use of
longer threads will cause irreparable damage to the heater core.
Use of Non-Weller nozzles may result in damage to the hot air
tool and void the warranty.
Z Pay attention to the correct thread depth of the screw-in
nozzles!
Z Always use Weller original hot air nozzles!
The WXHAP 200 is supplied with an 8 mm socket wrench. Use this
to replace the nozzles. Tighten the nuts on the heater core using the
supplied open-end wrench.
Note To use the nozzles, screw the supplied nozzle adaptor (5)
(T005 87 617 28) into the WXHAP 200 using the 8 AF socket
wrench. You can use the same nozzles as those for the
WXHAP 200.
Replacement hot air tools are supplied preset and can be connected
and used without any need for readjustment.
To check the hot air temperature, it is recommended that you use a
special test nozzle (T005 87 278 08) which mates with a sheathed
thermocouple (Ø 0.5 mm).
WXHAP 200 7-7
DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT
6 Accessories
WXHAP 200 Hot Air Nozzles (see overview Hot Air Nozzles)
7 Disposal
Dispose of replaced equipment parts, filters or old devices in
accordance with the rules and regulations applicable in your country.
8 Warranty
Claims by the buyer for physical defects are time-barred after a
period of one year from delivery to the buyer. This does not apply to
claims by the buyer for indemnification in accordance with §§ 478,
479 BGB (German Federal Law Gazette).
We shall only be liable for claims arising from a warranty furnished
by us if the quality or durability warranty has been furnished by use
in writing and using the term "Warranty“.
In addition, for the USA and Canada:
Weller Tools GmbH warrants to the original purchaser and any
subsequent owner (“Buyer”) that Weller soldering and desoldering
products will be free from defects in material and workmanship for a
period of one year from date of purchase, provided that no warranty
is made with respect to products which have been altered, subjected
to abuse or improperly used, installed or repaired. Use of non-Weller
Tools GmbH components will void this warranty if a non-Weller
Tools GmbH component is defective (or is the source of the defect).
Weller Tools GmbH will repair or replace products found to be
defective not caused by a part, component or accessory
manufactured by another company, during the warranty period.
Contact Weller Tools with dated proof of purchase and return to
Apex Tool Group LLC., 14600 York Rd. Suite A, Sparks, MD 21152
USA. All costs of transportation and reinstallation shall be borne by
the Buyer.
IN NO EVENT SHALL WELLER TOOLS GMBH BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. WELLER TOOLS
GMBH LIABILITY FOR ANY CLAIMS ARISING OUT OF THIS
WARRANTY SHALL NOT EXCEED THE PURCHASE PRICE OF
THE PRODUCT.
THE PERIOD OF ALL IMPLIED WARRANTIES APPLICABLE TO
THIS PRODUCT INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS, OR FITNESS FOR A
PARTICULAR PURPOSE IS LIMITED TO 12 MONTHS FROM THE
DATE OF PURCHASE BY THE USER.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may
not apply to you. Some states do not allow limitation on how long an
implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have
other rights, which vary from state to state. Subject to technical
alterations and amendments! See the updated operating instructions
at www.weller-tools.com.
EN FR
FR
ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT DE
WXHAP 200
Model d'emploi
WXHAP 200
WXHAP 200
Schéma de l'appareil
1 Connecteur avec câble
2 Flexible d'air chaud
3 Bouton poussoir
4 Support
5 Embout à buse
6 Buse
En cas de non utilization de l'outil de
soudage, toujours le poser dans la
plaque reposoir de sécurité.
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156

Weller WXHAP 200 Operating Instructions Manual

Taper
Operating Instructions Manual

dans d''autres langues