Ubiquiti Loco5AC Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

NanoStation loco Zip Tie
Package Contents
Installation Requirements
Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor
wired Ethernet connections and should be grounded through the AC ground of the
PoE.
We recommend that you protect your networks from harmful outdoor environments
and destructive ESD events with industrial-grade, shielded Ethernet cable from
Ubiquiti. For more details, visit ui.com/toughcable
Surge protection should be used for all outdoor installations. We recommend that
you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation
loco and the other at the entry point to the building. The ETH-SP will absorb power
surges and safely discharge them into the ground.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Diagram Showing Use of Ethernet Surge Protectors
Hardware Overview
Port View
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Power LED
Ethernet Port
Reset Button
The Power LED will light blue when the device is connected to a power source.
10/100/1000 Ethernet port used to connect the power and should be connected to
the LAN and DHCP server.
To reset to factory defaults, press and hold the Reset button for more than 10
seconds while the device is powered on.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Hardware Installation
1.
2.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Pole Mount
1.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
2.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
3.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Connecting Power
WARNING: The switch port must comply with the power specifications listed in
this “Specifications”.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Accessing airOS via Wi-Fi
Verify connectivity in the airOS® Configuration Interface using the UNMS™ app or Web
Portal. Both are available for 15 minutes immediately after you power on the device. If
necessary, you can power cycle the device to re-enable its Wi-Fi.
UNMS App
1. Download the UNMS app.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
2. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
3. Launch the app and follow the on-screen instructions.
Web Portal
1. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
2. Launch your web browser and go to: http://setup.ui.com
3. Select your Country and Language. You must agree to the Terms of Use to use the
product. Click Continue.
Note: Ensure that DHCP is enabled on your Wi-Fi adapter.
Note: Ensure that your Wi-Fi connection has DHCP enabled.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
4. Create a username and password. Confirm your new password and then click Save.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
The airOS Configuration Interface will appear, allowing you to customize your settings
as needed. For additional details, refer to the User Guide available at
ui.com/download/airmax-ac
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s
responsibility to make sure the device is operated within local country regulatory
requirements.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
The Output Power field is provided to the professional installer to assist in meeting
regulatory requirements.
Specifications
Loco5AC
Dimensions 179 x 77.5 x 59.1 mm
(7.05 x 3.05 x 2.33")
Weight 180 g (6.35 oz)
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Loco5AC
Processor MIPS 74K
Memory DDR2 64 MB
Antenna Gain 13 dBi
Networking Interface (1) 10/100/1000 Ethernet Port
Power Method Passive PoE 2-Pair (Pairs 4, 5+; 7, 8 Return)
Power Supply 24V, 0.3A Gigabit PoE Supply*
Max. Power Consumption 7W
Supported Voltage Range 24V ±10%
ESD/EMP Protection ±24kV Contact / Air
Operating Temperature -40 to 70° C (-40 to 158° F)
Operating Humidity 5 to 95% Noncondensing
Certifications CE, FCC, IC
* Not included. Recommended PoE Adapter: POE-24-12W-G.
Operating Frequency (MHz)
Worldwide 5150 - 5875
US/CA U-NII-1 5150 - 5250
U-NII-2A 5250 - 5350
U-NII-2C 5470 - 5725
U-NII-3 5725 - 5850
Management Radio (MHz)
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Management Radio (MHz)
Worldwide 2412 - 2472
US/CA 2412 - 2462
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote
risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated
on the manufacturers label. Connection to a different power source than those specified may
result in improper operation, damage to the equipment or pose a fire hazard if the limitations are
not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only
by a qualified service technician.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and,
where applicable, specify arbitration instead of jury trials or class actions.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could
void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio
communications. Operations of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
This radio transmitter has been approved by ISED Canada.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential
for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement
This equipment complies with radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 25 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
AVIS IMPORTANT
Déclaration sur l’exposition aux rayonnements
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans un
environnement non contrôlé.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait
une distance minimale de 25 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre émetteur,
et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential
environment this equipment may cause radio interference.
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não
pode causar interferência em sistemas devidamente autorizados.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are
applicable to it.
Country List
AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz
frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may operate at 36
dBm.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
Other countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
© 2020 Ubiquiti Inc. All rights reserved.
Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Ubiquiti Loco5AC Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues