Nuvo Essentia BTicino NV-E6DXS-BT Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

Essentia
®
BTicino
®
*
*BTicino is a registered trademark of the BTicino Co.
ENGLISH
Danger
Exposure to extremely high noise levels may cause a permanent
hearing loss. Individuals vary considerably to noise induced hearing
loss but nearly everyone will lose some hearing if exposed to sufficiently
intense noise for a sufficient time. The U.S. Government's
Occupational Safety and Health Administration (OSHA) has specified
the following permissible noise level exposures:
According to OSHA, any exposure in the above permissible limits could
result in some hearing loss. Ear plugs or protectors in the ear canal or over
the ears must be worn when operating this amplification system in order to
prevent a permanent hearing loss. If exposure in excess of the limits as
put forth above, to insure against potentially harmful exposure to high
sound pressure levels, it is recommended that all persons exposed to
equipment capable of inducing high sound pressure levels, such as this
amplification system, be protected by hearing protectors while this unit is in
operation.
DURATION PER DAY (HOURS)86432 1
SOUND LEVEL (dB) 90 93 95 97 100 103
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE
PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE
TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE
OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING)
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.
1. Read all safety and operating instructions before using this
product.
2. All safety and operating instructions should be kept for future
reference.
3. Read and understand all warnings listed on the operating
instructions.
4 . Follow all operating instructions to operate this product.
5. This product should not be used near water, i.e. bathtub, sink,
swimming pool, wet basement, etc.
6. Only use dry cloth to clean this product.
7. Do not block any ventilation openings, It should not be placed flat
against a wall or placed in a built-in enclosure that will impede the
flow of cooling air.
8. Do not install this product near any heat sources ; such as,
radiators, heat registers, stove or other apparatus (including heat
producing amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than the
other. A grounding-type plug has two blades and a third grounding
prong. The wide blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord being walked on or pinched, particularly at
plugs, convenience receptacles and the point where they exit
from the apparatus. Do not break the ground pin of the power
supply cord.
11 . Only use attachments specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by
the manufacturer or sold with the apparatus. When a cart is used,
use caution when moving cart/apparatus combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for
long periods of time.
14. Care should be taken so that objects do not fall and liquids are
not spilled into the unit through the ventilation ports or any other
openings.
15. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way;
such as, power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally
or has been dropped.
16. WARNING: To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
IMPORTANT SAFETY INSTRUCTIONS
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE CHASSIS. NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
CAUTION
APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING
AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES,
SHALL BE PLACED ON THE APPARATUS.
1
FRENCH
DURE EN HEURES PAR JOUR 8 6 4321
INIVEAU SONORE CONTINU EN dB 90 93 95 97 100 103
Danger
L‘exposition a des niveaux eleves de bruit peut provoquer une perte
permanente de l’audition, Chaque organisme humain reagit
differemment quant a la perte de l’audition, mais quasiment tout le
monde subit une diminution de I’acuite auditive lors d’une exposition
suffisamment longue au bruit intense. Les autorites competentes en
reglementation de bruit ont defini les expositions tolerees aux niveaux
de bruits:
Selon les autorites, toute exposition dans les limites citees ci-dessus,
peuvent provoquer certaines pertes d’audition. Des bouchons ou
protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors
de l’utilisation de ce systeme d’amplification afin de prevenir le risque
de perte permanente de l’audition, Dans le cas d’expositions
superieures aux limites precitees il est recommande, afin de se
premunir contre les expositions aux pressions acoustiquese I evees
potentielIement dangeure u ses, aux personnes exposees aux
equipements capables de delivrer de telles puissances, tels ce
systeme d’amplification en fonctionnement, de proteger l’appareil
auditif.
ATTENTION: AFIN DE LlMlTER LE RISQUE DE CHO ELECTR/QUE, NE
PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE
PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR.
CONFER LE SERVICE APRES-VENTE AUX
REPARATEURS
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT
QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR
PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES
DOCUMENTS FOURNIS AVEC CE PRODUIT.
IMPORTANTES INSTRUCTIONS DE SECURITE
1. Lire avec attention toutes les recommandations et précautions
d'emploi avant d'utiliser ce produit.
2. Toutes les recommandations et précautions d'emploi doivent être
conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les avertissements énumérés dans les
précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par exemple
baignoires, éviers, piscine, sous-sol humides ... Etc.
ée, cela
Protéger
pincement, particulièrement au niveau des fiches, des
réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas
casser la fiche de terre du cordon d'alimentation.
11. Utiliser uniquement les accessoires spécifiés par le constructeur.
12. Utiliser uniquement avec le chariot de transport, le support, le
trépied, la console ou la table spécifiés par le constructeur ou
vendus avec l'appareil. Lors de l'utilisation d'un chariot, bouger
avec précaution l'ensemble chariotlappareil afin d'éviter les
dommages d'un renversement.
13 Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé
pendant une longue période.
14. Des précautions doivent être prises afin qu'aucun objet ne tombe
et qu'aucun liquide ne se répande à l'intérieur de l'appareil par
les orifics de ventilation ou n'importe quelle autre ouverture.
15. Pour toutes interventions techniques s'adresser à un technicien
qualifié.L'intervention technique est nécessaire lorsque l'appareil
a été endommagé de n'importe quelle façon, comme par
exemple si le cordon secteur ou sa fiche sont détériorés,si du
liquide a coulé ou si des objets sont tombés à l'intérieur de
l'apparei1,si l'appareil a été exposé à la pluie ou à l'humidité, s'il
ne fonctionne pas normalement ou s'il est tombé.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc
electrique ne pas exposer l'appareil à la pluie ou à l'humidité.
6. Utiliser exclusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le
produit tout contre un mur ou dans une enceinte fern
gênerait le flux d'air nécessaire au refroidissement.
8. Ne pas placer le produit près de toute source de chaeur telle que
radiateurs, arrivées d'air chaud, fourneaux ou autres appareils
générant de la chaleur (incluant les amplificateurs producteurs
de chaleur) .
9. Ne pas négliger la sécurité que procure un branchement polarisé
ou avec raccordement à la terre, Un branchement polarisé
comprend deux fiches dont l'une est plus large que l'autre. Un
branchement à la terre comprend deux fiches plus une troisième
reliée à la terre. Si la fiche secteur fournie ne s'insert pas dans
votre prise de courant. consulter un 'électricien afin de remplacer
votre prise obsolète.
10. le cordon d'alimentation de tout écrasement ou
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE
ELECTRIQUE, NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A
L'HUMIDITE.
2
Introduction
Congratulations on your purchase of the NuVo Essentia System. Essentia brings the best of today's digital technology to a true whole-
home audio system. Listening to multiple audio sources from independent zones throughout the home has never been easier or more
affordable.
The elegant BTicino style keypads allow independent selection of up to six different audio sources from up to twelve zones in the
home. They are available in white, black and silver to match a variety of decorating choices. Generation D digital amplification provides
clear, precise digital sound to each zone without the heat generated by traditional analog amplification. The integrated infrared repeater
in each keypad means you can control all of your audio sources wirelessly from any zone of your home.
Enjoying quality audio throughout the home is simple and affordable with Essentia. This installation manual is designed to provide a
sequential, step-by-step guide to making full use of the many features and capabilities of the Essentia System.
E6DS-BT Main System
1 NV-E6DMS Six-Source, Six-Zone Amplifier
6 NV-E6DKP-BT Bticino style Zone Controller Keypads
available in white, black and silver.
1 NV-LRC1 Learning Remote Control
1 NV-E6DEZP Decora EZ Port Multi-port connection hub
1 NV-NEC Network connection cable
6 NV-VEC IR emitters with feedback LED
1 NV-PC2 IEC 2-wire power cable
®
®
Package Contents:
®
E6DXS-BT Expander System
1 NV-E6DMS Six-Source, Six-Zone Amplifier
6 NV-E6DKP-BT Bticino style Zone Controller Keypads
available in white, black and silver.
1 NV-LRC1 Learning Remote Control
1 NV-SRC 1 Source Link Cable
1 NV-DNK1 Data Link Cable
1 NV-PC2 IEC 2-wire power cable
®
3
CCC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Source 6
Sat.
Audio
Out
Source 1
Tuner 1
Audio
Out
Source 2
Tuner 2
Audio
Out
Source 5
CD 2
Audio
Out
Source 4
CD 1
Audio
Out
Source 3
Tuner 3
Audio
Out
Essentia D
Wiring Diagram
Zone/Room 1 Zone/Room 2 Zone/Room 3 Zone/Room 4 Zone/Room 5 Zone/Room 6
Diagram shown with optional NuVo
NV-P2100 auxiliary amplifier powering
zone 6.
EZ Port Cat-5
connection
Single Network cable
connection to the
Essentia Amplifier
R
L
SENSITIVITY
OdBV = 1.0RMS
-12
+6
0
LEFT
+6
-12
RIGHT
0
AUDIO
INPUT
2
INPUT
OUTPUT
CONTROL
SPEAKER
MODELNV-P2100
HIGHEFFICIENCY 200 WATT
STEREOAMPLIFIER
NuVoTechnologies Cincinnati Ohio. USA
120V
60HZ
WATTS
250
UNIT
ON
+12VDC
100mA
VOLTAGE
TRIGGER
3-30 VOLTS
AC OR DC
ON/OFF SWITCH
AUDIO AC/DC
POWER
MODE
OUTPUT POWER
8 OHM: 70W X 2
4 OHM: 100W X 2
CONTROL
USE ONLYWITH 250V FUSEUSE ONLYWITH 250V FUSE
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
ZONE 6
SYSTEM
ZONE TRIGGEROUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-I6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT.MUTE
SUM1
1
13
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-I6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
R
NuVoTechnologies HebronKY USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
Essentia D
V.II
USE ONLYWITH 250V FUSE
3033118
C
US
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CAN/CSASTD.E60065
POWER
STAND BY
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
1
2
3
V.II
Essentia Front Panel
1. POWER Button:
2. STAND BY LED:
3. Zone Status LED's:
The amplifier is designed to be turned on and remain on. The power button supplies power to the system. Each
zone can then be turned on or off independently. The amplifier should be turned on before any external
connections are made. This activates internal protective circuitry.
When lit, this blue LED (light-emitting diode) indicates that the amplifier is plugged into an AC power outlet
source.
These LED's indicate the power status of each zone. When a zone LED is lit, it indicates that the zone is
currently turned on.
1
3
4
2
5
6
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
Keypad Features
1. Volume Level
2. Power
3. Volume
4. IR Receiver
5. Mute
6. Source Selection
The level of the zone volume is indicated by these LEDs (light-emitting diodes).
The power button turns that keypad's zone on and off independently of the other zones. Pressing and holding
the power button turns all zones off simultaneously.
Independent audio volume level for each zone is controlled with these buttons.
Each keypad has an IR (infrared) receiver located under the volume button for wireless control of the audio
source equipment.
The mute button temporarily silences any audio playing in that keypad's zone.
The source buttons independently select any of the six sources connected to the Essentia amplifier.
The selected source button will remain lit.
4
Essentia Back Panel
1. Audio Source Inputs:
2. Source Link:
3. Variable Lineout:
4. Fixed Lineout:
5. Speaker Outputs:
6. Zone Triggers:
7. Emitter Outputs:
8. System On:
9. External Mute:
10. Network Input:
11. Digital Link:
12. RS232 Port:
13. AC Power:
The Essentia amplifier accepts up to six audio sources. A source consists of any audio component capable
of supplying a line level signal.
This multi-pin connection is used to transfer the audio information from the Essentia main amplifier to the
expander amplifier. This output is used to expand the system to twelve zones. The source link connection
cable is provided with the Essentia D Expander package.
The variable lineout is intended for zones where additional amplification is needed and the Essentia keypad
is used to control the volume of all the speakers in that zone.
The fixed lineout is intended for zones where additional amplification and separate volume control are
needed.
Individual stereo speaker outputs for each zone provide 20 watts output per channel.
These outputs provide a 12-volt output when the corresponding zone is turned on. This is used to trigger
external equipment specific to a given zone.
These outputs transfer IR (infrared) signals, repeated from a zone keypad, from the Essentia amplifier to
the audio source equipment. There are six source specific outputs and two “sum” output that sends IR
signals regardless of the selected source.
This output provides a constant 12-volt output when any zone is turned on. This is used to trigger external
devices.
This is designed to mute any audio playing through the system when the phone or doorbell rings.
This RJ-45 connection is the input for all zone information coming from the Essentia keypads. The
connection is made using the Network Cable supplied with the package.
This multi-pin connection transfers all the digital information from the main amplifier to the expander
amplifier. This output is used to expand the system from six to twelve zones. The Digital Link connection
cable is provided with the Essentia D Expander package.
The RS232 serial port allows two-way communication for control by a home automation system.
A detachable power cable supplies power to the Essentia System from any AC outlet.
5
ZONE 6
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
1
2
3
4
5
6
8
9
10 11
12
13
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
SUM1
1
1
3
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
FIXED
OUTPUT
R
NuVo TechnologiesHebron KY USA
FUSE:T5 A
120V 60Hz 500W
MODEL NV-6DM2
SIX SOURCESIX ZONE
AUDIO DISTRIBUTIONSYSTEM
www.nuvotechnologies.com
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
Essentia D
V.II
1. Setup:
2. Whole-Home Control:
3. Transport Buttons:
4. Video Source Control:
5. Source Volume:
6. Numeric Buttons:
7. Power Button:
8. Channel up and down:
9. Macro Buttons:
The setup button is used to place the
remote control in program/learn mode.
This section automatically performs the
basic Essentia keypad functions.
The transport buttons perform basic
source specific functions, such as play,
stop, pause, forward and reverse.
These buttons are typically used by
video equipment for menu navigation
and selection.
This is source specific volume control,
such as a TV or stereo receiver. This is not
used for NuVo zone volume.
These buttons provide source specific
direct numeric access.
This power button is for source specific
power on and off. It is not for NuVo zone
on and off.
This button provides source specific
channel scrolling.
These buttons do not perform a given
source function. They can be used for
programming multiple function macro
commands.
1
2
3
4
5
6
MUTE
VOL-
VOL+
ON/OFF
W
H
O
L
E
-
O
H
M
E
C
O
N
T
R
L
O
W
H
O
L
E
-
O
H
M
E
C
O
N
T
R
L
O
S
O
UR
C
E
NV-LRC1
M1
M2
M3
M4
M6
M5
M7
M8
1
3
4
2
5
7
8
9
LRC1 Learning Remote Control
6
7
Installing the Essentia System in Your Home
I. Prewire
The Essentia System uses CAT5 cable for keypad control and either two or four-conductor 16-gauge speaker wire. All the wire is
“homerun” from each zone to the location of the Essentia amplifier and Audio Source equipment.
Complete CAT5 Crimping Instructions
The NuVo audio systems require CAT5, unshielded, twisted
pair (UTP), for communication between the
keypads/Display Pads and the main amplifier unit. Each
end of the wire is terminated with an RJ45 connector.
The Essentia System can accommodate 2,000 total feet of
CAT5 cable. For the most reliable operation, it is best that
no single run of CAT5 exceeds 250 feet.
The correct wiring scheme for the CAT5 cable is standard
EIA/TIA 568A. Properly terminating the CAT5 cable is
crucial for the operation of the system. It is very important
to use a good quality crimp tool, and test each end to end
run with a CAT5 wire tester to insure that your system
operates flawlessly, fig.1.
1. Strip a 2 to 3 inch portion of the insulation,
exposing the 4 twisted pairs.
2. Untwist the wires and fan them out
individually. Arrange the wires into the
correct color scheme as shown in Fig. 1.
3. Flatten the wires in their correct order, and trim
them evenly across the top. Most crimp tools have
a wire trimmer built-in. It is best to trim the wires
to about ½” in length.
4. While holding the wires flat between your thumb
and forefinger, insert the wires into the RJ45
connector, so each is in its own slot. Push the wire
into the RJ45, so all 8 conductors touch the end of
the connector. The insulation jacket should
extend beyond the crimp point of the RJ45.
5. Insert the RJ45 into the crimp tool receptacle and
squeeze the tool firmly. Note that a ratchet type
tool should tighten down until it no longer clicks.
6. The RJ45 should be firmly crimped to the CAT5
insulation. It is necessary that the color scheme
be repeated identically on each end of the wire.
Step-by-Step Crimping Instructions:
Fig. 1: EIA 568A wiring scheme for CAT5 Cable
Pin #
1. Green Stripe
2. Green
3. Orange Stripe
4. Blue
5. Blue Stripe
6. Orange
7. Brown Stripe
8. Brown
Note: Colors listed as “stripe” are a white wire
with a colored stripe.
Step 1 Step 2 Step 3
Step 4 Step 5 Step 6
12345678
Top view with
tab down.
Wires insert from
this end.
Pair 2
Pair 3
Pair 4
Pair 1
IR TX
Ground
Control Data Bus-
Control Data Bus+
IR Active
Ground
+12V Power
Ground
II. Terminating Speaker Wire
Be careful not to allow the exposed wire from each conductor to
touch the adjacent conductor. This will short the speaker input.
Each speaker output is designed for two 8-Ohm speakers.
Overloading the amplifier could cause it to overheat and do
damage to the output.
The speaker wire for each zone is terminated in a standard Euro-
style connector that plugs into each zone specific amplified
output. The common speaker termination scheme is Left - Left +,
Right - Right +. Either two or four-conductor 16-guage wire is
recommended. Larger than 14-guage wire will not fit into the
euro connector.
To terminate the speaker wire, strip back the outer jacket and
expose the inner conductors. Strip approximately 1/4” (4 mm)
of the insulation from the inner conductors exposing the copper
wire. Place the exposed wire in the euro connector and tighten
the screw down terminals, fig. 2.
II. Installing the Essentia Amplifier
The amplifier should be plugged in and the power button on the
front panel should be depressed before proceeding with the rest of
the installation.
System setup works best when the amplifier is placed in the
same location as the audio source equipment. This is typically in
an audio rack, entertainment center or a closet dedicated to
housing the home audio/video equipment.
This activates the internal protective circuitry of
the Essentia System.
III. Installing the NV-E6DEZP EZ Port
The EZ Port is a multi-connection hub designed to accept all the
CAT5 wires from the keypads in the system. The location of the EZ
Port should be determined by the location of the Essentia
amplifier. It is best to place in the wall behind the amplifier that
would be easily accessible if necessary.
The EZ Port fits easily in any dual-gang size construction bracket
with an open back. These are often referred to as “mud rings”.
Simply plug the terminated CAT5 wires into any of the sixteen
available jacks on the back of the EZ Port, Fig. 3. The order in
which the individual CAT5 wires are plugged is in not important,
although it is strongly recommended that you label the CAT5 with
the appropriate zone number for future reference.
Once you have plugged the Cat-5 wires into the EZ Port, screw the
EZ Port into its construction bracket using the supplied mounting
screws.
-
-
+
+
LEFT
RIGHT
LEFT
RIGHT
Fig. 2
Fig. 3
8
IV. Connecting the EZ Port to the Essentia amplifier
When the EZ Port is installed in the wall the only part visible
should be the faceplate and a single RJ45 jack. The supplied pre-
terminated network cable can then be plugged into the jack on
the EZ Port and into the network connection on the back of the
Essentia amplifier, Fig. 4. Any CAT5 cable terminated using 568A
or 568B network wiring will suffice should you need a longer
connection.
SYSTEM
DIGITAL LINK
PROGRAM
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
NETWORK
EZ Port (front)
Essentia Network
Connection
Network Cable
NV-E6D EZ Port
Model NV-E6DEZP
Connect to NV-E6DM
Audio Distribution Amplifier
V. Attaching Audio Source Equipment to the Essentia Amplifier
Each piece of audio source equipment is connected to the
Essentia amplifier with standard stereo RCA cables. Attach the
RCA cable to the corresponding audio output on the source
equipment and to the desired source input on the back of the
Essentia amplifier, Fig. 5.
SOURCE LINK
SOURCE INPUTS
ZONE 1
ZONE 3
ZONE 2
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
ZONE 1
ZONE 3
ZONE 2
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VAR IAB LE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
Source 1
Tuner 1
Audio
Out
VI. Connecting the IR Emitters
IR commands for the source equipment are transferred from the
Essentia amplifier to the source equipment via mini IR mouse
emitters. Six of these are supplied with your Essentia System.
The emitter is plugged into the corresponding source IR output
on the Essentia and then placed over the IR receiver window on
the source component, fig. 6. The IR outputs are individually
routed to sources 1-6 allowing IR commands from the chosen
source to only control that source.
The two SUM outputs will flash any IR command that is sent from
any of the zones. This is used to connect the NuVo T2 Tuner,
which has a single IR direct input to control both tuners to the
Essentia System or an IR blaster designed to flash IR commands
to a variety of components. This is done by plugging a single
mono 1/8” patch cable into the SUM IR output and into the Direct
IR input.
Fig. 4
Fig. 5
Fig. 6
9
VII. Expanding Essentia to 12 Zones
Six additional listening zones can be added to the Essentia
System using the Essentia Expander package. The expansion is
easily done using the Source Link and Digital Link multi-pin
outputs on the Essentia main amplifier, Fig. 7.
The necessary cables for this are supplied with the Expander
package. No other connections are necessary with the exception
of the AC power cord and the additional speaker terminations.
The additional CAT5 wires for the zones 7-12 plug into the EZ
Port.
VIII. Installing the Essentia Keypads
You are now ready to install the keypads and complete the
Essentia installation. This is easily done using a rotary switch
located on the back of the keypad to set a specific zone address
for each keypad, Fig. 8.
The switch requires the use of a small flat screwdriver and is set
by turning the arrow insert on the switch to the appropriate zone
number. Zones 1-12 are set by using switch positions 1-C (note
that zones 10, 11 and 12 are denoted by A, B and C respectively).
Switch positions D, E, F and 0 are for additional keypads in zones
1-4.
Once each keypad’s zone address is set, the CAT5 can be plugged
in and the keypad installed in the wall.
It is important to note that the keypads will not function properly
unless each has its own unique zone address.
Source Link Cable
Data Link Cable
Fig. 8
Fig. 7
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
10
ZONE 6
SYSTEM
ZONE TRIGGEROUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITALLINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT.MUTE
SUM1
1
1
2
3
123
4
5
6
SUM2
5
45
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARI ABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
ZONE 12
ZONE TRIGGEROUTPUTS
SOURCE LINK
ZONE 71
DIGITALLINK
ZONE 9
ZONE 10
ZONE 11
ZONE 8
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
1
7
8
9
5
10 11
12
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
20W/6OHMX2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
Essentia D
V.II
R
NuVoTechnologiesHebron KY USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIXZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
3033118
C
US
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CAN/CSASTD.E60065
R
NuVoTechnologiesHebron KY USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DX
SIXSOURCE SIXZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
3033118
C
US
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CAN/CSASTD.E60065
Essentia Keypad
Model NV-E6DKP-BTBK
www.nuvotechnologies.com
NuVo Technologies LLC
Hebron, Kentucky USA
Use only with
NuVo System
Essentia
Utiliser uniquement avec
NuVo System
Essentia
WARNING:
AVIS:
Zone
Address
Network
Connection
Local Source
EQ Control and Source Grouping
To change bass response, press the Mute button and Source 1
button simultaneously. Adjust the bass level up or down by using
the Volume Up and Volume Down buttons. The volume indicator
LEDs will indicate the output level, fig. 8. Adjust treble response
using the same process. This is accessed by pressing the Mute
and Source 2 buttons. Once the desired setting is made, press
the Source button again to return the keypad to normal
operation.
Source grouping is a feature that allows multiple zones in an
open living space to always share the same source selection but
still retain individual volume and on/off control. This is achieved
by pressing Mute and Source 3. Volume Up enables the group
function, and Volume Down disables the group function and
causes the keypad to operate independently of all other groups,
fig. 10.
VOLUME
FLAT
-4 dB
+4 dB
+6 dB
+8 dB
-6 dB
-8 dB
Fig.10
VOLUME
Group Disabled
Group Enabled
Fig. 11
VOLUME
MUTE
CD2
TNR1
TNR2
DVD
CD1
SAT
Source 1
Source 2
Source 3
Source 4
Source 5
IX. Keypad Zone Settings
Each Essentia keypad has the ability to set specific zone
functions. These are bass and treble EQ, source grouping, all on
(party mode) and volume reset. Each of these functions is
accessed by pressing the MUTE and SOURCE 1-5 buttons
simultaneously, fig. 9.
While the keypad is in the function set mode, the appropriate
source button with flash. To return to normal zone control, press
the flashing source button.
Fig. 9
11
All On/Party Mode
Press the Mute
and Source 4
buttons to
initiate the
Master Mode.
The lit volume LED
will flash when the
keypad is in
Master Mode.
VOLUME
MUTE
CD2
TNR1
TNR2
DVD
CD1
SAT
Source 4
Fig. 12
Fig. 13
Fig. 14
VOLUME
VOLUME
-38 to -29 dB
-28 to -19 dB
-18 to -13 dB
-12 to -7 dB
-6to0dB
-54 to -39 dB
-78 to -55 dB
Volume Reset Off
Volume Reset On
Volume Reset
Each zone has the capability of turning on at two different
volume level settings. At factory default the zone will turn on at
the previous listening level. If desired, you can change that
default to a low level volume reset regardless of the previous
level.
To change the zone to volume reset mode, press the Mute and
Source 5 buttons simultaneously. The Source 5 button will begin
flashing. The volume LED will first appear at the far left
indicating no volume reset. Pushing the Volume Up button will
cause the volume LED to move to the far right position. This now
indicates that the zone is in volume reset mode, fig. 14.
To return to normal keypad operation, press the Source 5 button
again and it will stop flashing. In the volume reset mode the zone
will automatically turn on at a preset -60 dB level. The volume
reset can be turned off by repeating the above steps and
returning the volume LED to the far left position.
12
13
X. Using the Fixed and Variable Lineouts
Zone Variable Lineout
Each zone of the Essentia amplifier has two 3.5mm mini stereo outputs. These are fixed and variable lineouts used for adding additional
amplification when necessary for each zone. A distinct advantage to the NuVo equipment is the ability to use the amplified output,
variable and fixed lineouts all simultaneously on all zones. The Essentia amplifier has zone trigger outputs that provide a 12V trigger for
additional amplification. This enables the attached amplifier to be triggered on and off with the zone keypad.
The variable lineout is designed to allow additional audio amplification volume level to be controlled from that zone’s keypad. When
used in conjunction with the zone amplified output, fig. 15, all the speakers volume will track with the keypad volume level.
Fig. 15
R
L
SENSITIVITY
OdBV = 1.0RMS
-12
+6
0
LEFT
+6
-12
RIGHT
0
AUDIO
INPUT
2
INPUT
OUTPUT
CONTROL
SPEAKER
MODEL NV-P2100
HIGH EFFICIENCY 200 WATT
STEREO AMPLIFIER
NuVo TechnologiesCincinnati Ohio. USA
120V
60HZ
WATTS
250
UNIT
ON
+12VDC
100mA
VOLTAGE
TRIGGER
3-30 VOLTS
AC OR DC
ON/OFF SWITCH
AUDIO AC/DC
POWER
MODE
OUTPUT POWER
8 OHM: 70W X 2
4 OHM: 100W X 2
CONTROL
USE ONLYWITH 250V FUSE
CCC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
The Zone keypad controls the audio volume.
Diagram shown using the NuVo P2100 amplifier.
Source 1
Tuner 1
Audio
Out
Zone/Room 1
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
NuVoTechnologies CincinnatiOhio USA
FUSE:T5 A
120V 60Hz 500W
MODEL NV-6DM
SIX SOURCESIX ZONE
AUDIO DISTRIBUTIONSYSTEM
www.nuvotechnologies.com
ZONE 6
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
SUM1
1
13
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
R
NuVoTechnologies HebronKY USA
FUSE:T5 A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
Essentia D
V.II
USE ONLYWITH 250V FUSE
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
Zone Fixed Lineout
In some zone applications, it is more advantageous to have a separate volume control on the additional speakers being driven by an
additional amplifier. This is common with outdoor zones. The fixed lineout offers the capability to add amplification, but the audio signal
is not affected by the zone keypad volume level. Therefore, it requires a separate volume control for those speakers, fig. 16.
Fig. 16
14
R
L
SENSITIVITY
OdBV = 1.0RMS
-12
+6
0
LEFT
+6
-12
RIGHT
0
AUDIO
INPUT
2
INPUT
OUTPUT
CONTROL
SPEAKER
MODEL NV-P2100
HIGH EFFICIENCY 200 WATT
STEREO AMPLIFIER
NuVo TechnologiesCincinnati Ohio. USA
120V
60HZ
WATTS
250
UNIT
ON
+12VDC
100mA
VOLTAGE
TRIGGER
3-30 VOLTS
AC OR DC
ON/OFF SWITCH
AUDIO AC/DC
POWER
MODE
OUTPUT POWER
8 OHM: 70W X 2
4 OHM: 100W X 2
CONTROL
USE ONLYWITH 250V FUSEUSE ONLYWITH 250V FUSE
CCC
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Additional speakers are controlled by a separate
volume control.
Diagram shown using the NuVo P2100 amplifier.
Source 1
Tuner 1
Audio
Out
Zone/Room 1
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
ZONE 6
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
SUM1
1
13
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
R
NuVoTechnologies HebronKY USA
FUSE:T5 A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
Essentia D
V.II
USE ONLYWITH 250V FUSE
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
15
XI. The NV-LRC1 IR Remote Control
The Essentia System comes with the NV-LRC1 Learning Remote Control. This remote allows wireless control of all keypad functions, as
well as the functions of the audio source equipment. Each NuVo zone keypad has an IR receiver that captures the specific source
commands from any remote control and in turn sends the command ultimately to the appropriate source equipment. Embedded IR code
libraries makes use of the LRC1 with a large variety of audio and video equipment easy. For complete setup and functionality refer to the
User Guide included with the remote control. Additional remote controls are available from NuVo.
XII. NV-MI1 Mute Interface Adapter
The Mute Interface is used in conjunction with System Mute input in the back of the Essentia amplifier. It acts as a relay for a voltage
from up to two phone lines and two doorbell transformers. When a voltage is presented to the MI1 it then sends a contact closure to the
Essentia System, which in turn causes the system to mute momentarily. This is useful in allowing the telephone ring or doorbell to be
heard when audio is playing in any of the zones, Fig. 17.
MUTE INTERFACE
ADAPTER
NV-MI1
CONNECT TO
MUTE INPUT
A
B
A
B
DOORBELL 1
DOORBELL 2
Connect to Telephone RJ-11
Line 1: Pins 3,4 Line 2: Pins 2,5
Mute Interface Module
Model NV-MI1
R
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
SYS ON
EXT. MUTE
L
R
L
R
L
R
VARIABLE
OUTPUT
FIXED
OUTPUT
SUM1
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
NuVoTechnologies CincinnatiOhio USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM
SIXSOURCESIXZONE
AUDIO DISTRIBUTIONSYSTEM
www.nuvotechnologies.com
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
12 34 5
6
12 34 5
6
13
5
135
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
USE CNLY WITH 250V FUSE
2
4
6
SUM2
24
6
OUTPUT POWER
20W/6OHM X2
ZONE 6
ZONE 6
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
Fig. 17
Essentia D
V.II
The MI1 connects to the NuVo amplifier using a standard
mono patch cable with a mini-plug on each end. Plug one
end into the EXT. MUTE input on the back of the
amplifier and the other end into the input on the front of
the Mi1.
The back of the MI1 will accept up to two AC or
DC voltages from two different doorbell chimes.
This connection is done with a two conductor
wire from the terminals on the doorbell chime to
the Doorbell A or Doorbell B inputs on the back
of the MI1. Polarity is not important for this
connection.
Up to two phone lines can be brought into
the RJ-11 connection on the back of the MI1.
The voltage from the phone ringer will
trigger the NuVo System to mute.
16
XIII. NV-LSA40 Local Source Amplifier
The LSA40 is 40 watt accessary amplifier that allows any line-level audio signal local to a zone to be amplified through that zones
speakers. It is designed to be used universally in a variety of applications, but as shown in fig. 18, it can be triggered on and off by any
zone keypad. When connected to the keypad, the user will listen to the NuVo audio system when the zone is turned on. When the zone is
off the LSA40 will automatically amplify any incoming local audio signal.
Fig. 18
INPUT
POWER
+
+
-
-
L
L
L
L
R
R
R
R
+
+
+
+
-
-
-
-
MODEL:NV-LSA40-DC
LOCALSOURCE AMPLIFIER
DESIGNEDIN USA
28VDC
Control
Voltage
1.5A
MADEIN CHINA
TOA
M
P
L
IF
I
E
R
TO
S
P
E
A
K
ER
I
N
T
E
R
T
E
K
3033118
I
N
T
E
R
T
E
K
CM
The connection from the LSA40 to
the Essentia or Concerto keypads
is done using the provide two
prong plug.
Atwoconductorwireisusedasavoltage
trigger from the LSA40 the NuVo zone
keypad. When the zone is turned on this
allows the NuVo system audio to pass to
the zone speakers. When the zone is
turned off the internal amplifier of the
LSA40 is automatically engaged.
LSA40P Back
LSA40P Front
Zone/Room 1
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Any NuVo System
zone output can be
wired to the LSA40
Local Source
Amplifier.
NuVo System zone speakers.
50 Watt AC
power adapter
supplied with
the LSA40P
ZONE 6
SYSTEM
ZONE TRIGGEROUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT.MUTE
SUM1
1
13
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
R
NuVoTechnologies HebronKY USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
Essentia D
V.II
USE ONLYWITH 250V FUSE
3033118
C
US
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CAN/CSASTD.E60065
XIV. NV-LSA40PD Local Source Amplifier Power Distribution Hub
The LSA40PD is a great device for distributing the necessary DC power to up to 4 individual LSA40 amplifiers. This allows the LSA40
components to be remotely located without the need for an external power supply in the zone, fig. 19. The LSA40PD is typically located
where the Essentia amplifier is installed. The power from the head end to each of LSA40 locations is sent over standard 16 gauge speaker
wire.
17
Fig. 19
+
+
-
-
L
L
L
L
R
R
R
R
+
+
+
+
-
-
-
-
MODEL:NV-LSA40
LOCAL SOURCEAMPLIFIER
2
8
V
D
C
TO
K
E
Y
P
A
D
1.5A
TO AMPLIFIER
TO SPEAKER
WIRE STRIP 5/16” (8MM)
Designed In USA
Made In China
NuVoTechnologies LLC Cincinnati, Ohio USA
www.nuvotechnologies.com
+
+
-
-
L
L
L
L
R
R
R
R
+
+
+
+
-
-
-
-
MODEL:NV-LSA40
LOCAL SOURCEAMPLIFIER
2
8
V
D
C
TO
K
E
Y
P
A
D
1.5A
TO AMPLIFIER
TO SPEAKER
WIRE STRIP 5/16” (8MM)
Designed In USA
Made In China
NuVoTechnologies LLC Cincinnati, Ohio USA
www.nuvotechnologies.com
+
+
-
-
L
L
L
L
R
R
R
R
+
+
+
+
-
-
-
-
MODEL:NV-LSA40
LOCAL SOURCEAMPLIFIER
2
8
V
D
C
TO
K
E
Y
P
A
D
1.5A
TO AMPLIFIER
TO SPEAKER
WIRE STRIP 5/16” (8MM)
Designed In USA
Made In China
NuVoTechnologies LLC Cincinnati, Ohio USA
www.nuvotechnologies.com
+
+
-
-
L
L
L
L
R
R
R
R
+
+
+
+
-
-
-
-
MODEL:NV-LSA40
LOCAL SOURCEAMPLIFIER
2
8
V
D
C
TO
K
E
Y
P
A
D
1.5A
TO AMPLIFIER
TO SPEAKER
WIRE STRIP 5/16” (8MM)
Designed In USA
Made In China
NuVoTechnologies LLC Cincinnati, Ohio USA
www.nuvotechnologies.com
+
-
+
-
MODEL:NV-LSA40PD-DC
LOCAL SOURCE AMPLIFIER
DESIGNED IN USA
28VDC 5A
ZONE 1
MADE IN CHINA
I
N
T
E
R
T
E
K
3033118
I
N
T
E
R
T
E
K
CM
ZONE 3
+
-
+
-
ZONE 2 ZONE 4
POWER
LSA40PD Front
LSA40PD
Back
200 Watt AC
power adapter
included with
the LSA40PD
AC Power Source
LSA40 Back
LSA40 Back
LSA40 Back
LSA40 Back
D
16 gauge 2 conductor speaker wire is required to
send voltage from the LSA40PD to four separate
zones.
Any NuVo System zone
output can be wired to the
LSA40 Local Source
Amplifier.
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
R
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
SYS ON
EXT.MUTE
L
R
L
R
L
R
VARIABLE
OUTPUT
FIXED
OUTPUT
SUM1
3033118
C
US
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CAN/CSASTD.E60065
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
12 34 5
6
12 34 5
6
13
5
135
RS-232
CONNECT TO
NV-I6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
USE CNLYWITH 250V FUSE
2
4
6
SUM2
24
6
OUTPUT POWER
20W/6OHM X2
ZONE 6
ZONE 6
SYSTEM
ZONE TRIGGEROUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITALLINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
Essentia D
V.II
-
18
XV. NV-LSI12 Local Source Interrupt
A lower cost alternative to the LSA40 is the LSI12. This is a non-amplified local source interrupt. It is installed in the same way the LSA40
is installed, but the incoming local signal must be amplified, fig 20. This is a useful accessory where a local amplified signal is already
present.
Fig. 20
LOCAL SOURCE
SWITCH
NV-LSI12
CONNECT TO
AMPLIFIER
RLY+
RLY-
L-
L+
R-
R+
To A m
plifier
To Keypad
To Speakers
L-
L+
R-
R+
Model NV-LSI12
Mute Interface Module
The selected zone speaker output of the Essentia or Simplese
amplifier is wired directly to the LSI12.
The connection from the LSI12 is
done with the provided two prong
plug. Make sure that red is positive
and black is negative when splicing
the 2-conductor wire from the LSI12.
A 2-conductor wire from a
relay on the LSI12 plugs into
the back of the zone keypad.
When the Essentia or Simplese
keypad is turned off the local source
is routed to the zone speakers.
The Essentia or Simplese is active
when the zone keypad is turned on.
4-conductor speaker
wire from the LSI12 to
the zone speakers.
Speaker input from Essentia or Simplese.
LSI12 front
LSI12 back
VOLUME
MUTE
CD1
CD2
TNR1
TNR2
DVD
SAT
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ZONE 6
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
RS-232
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
CONNECT TO
NV-E6DEZP
USE NV-NC1
CABLE
SYS ON
EXT. MUTE
SUM1
1
13
5
135
2
4
6
SUM2
5
24
6
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
12 34 5
6
12 34 5
6
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
TIP=L
RING=R
R
NuVoTechnologies HebronKY USA
FUSE:T5A
120V 60Hz 500W
MODEL NV-6DM2
SIXSOURCE SIX ZONE
AUDIODISTRIBUTION SYSTEM
www.nuvotechnologies.com
Essentia D
V.II
USE ONLYWITH 250V FUSE
3033118
C
S
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSASTD.E60065
Amplified signal from the local zone source
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Nuvo Essentia BTicino NV-E6DXS-BT Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à