Datalogic DRAGON M SERIES Guide de référence

Catégorie
Radios
Taper
Guide de référence
DRAGON™ M SERIES
Quick Reference
Guida Rapida
Guide Rapide
Kurzanleitung
Guía Rápida
DRAGON™ M SERIES
Quick Reference
Guida Rapida
Guide Rapide
Kurzanleitung
Guía Rápida
DRAGON™ M SERIES
QUICK REFERENCE
GUIDA RAPIDA
GUIDE RAPIDE
KURZANLEITUNG
GUÍAPIDA
DATALOGIC S.p.A.
Via Candini 2
40012 - Lippo di Calderara di Reno
Bologna - Italy
DRAGON™ M Series
Ed.: 10/2002
ALL RIGHTS RESERVED
Datalogic reserves the right to make modifications and improvements without prior
notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein,
nor for incidental or consequential damages resulting from the use of this material.
Product names mentioned herein are for identification purposes only and may be
trademarks and or registered trademarks of their respective companies.
© Datalogic S.p.A. 2001 - 2002
820001002 (Rev. B)
iii
CONTENTS
Using DRAGON™ M Laser Guns..................................................................... 2
Charging the Batteries...................................................................................... 5
DLL6000-R Compatibility.................................................................................. 6
DRAGON™ M/OM-DRAGON™ Stand Alone Setup......................................... 6
Using Multiple Guns with Same Cradle............................................................. 8
DRAGON™ M/STAR-Modem™ in Stand Alone Mode...................................... 9
DRAGON™ M/STAR-SYSTEM™ Setup ........................................................ 10
DRAGON™ M Default Configuration.............................................................. 12
Technical Features......................................................................................... 13
Warranty......................................................................................................... 14
Compliance .................................................................................................... 14
Reading Diagrams.......................................................................................... 71
DLL6000-R Configuration ............................................................................... 72
Using Multiple Guns with Same Cradle........................................................... 73
Radio Timeout................................................................................................ 74
Numeric Table................................................................................................ 75
INDICE
Descrizione e Uso........................................................................................... 16
Carica e Installazione delle Batterie................................................................ 19
Compatibilità con la Pistola DLL6000-R.......................................................... 20
Configurazione di DRAGON™ M/OM-DRAGON™ in Sistemi Stand Alone..... 20
Comunicazione di più Lettori con la Stessa Base Radio................................. 22
DRAGON™ M/STAR-Modem™ in Modalità Stand Alone............................... 23
Configurazione di DRAGON™ M/ STAR-System........................................ 24
DRAGON™ M – Configurazione di Default..................................................... 26
Caratteristiche Tecniche................................................................................. 27
Garanzia......................................................................................................... 28
Conformità...................................................................................................... 28
Diagrammi di Lettura ...................................................................................... 71
Configurazione del DLL6000-R....................................................................... 72
Comunicazione di più Lettori con la Stessa Base Radio................................. 73
Radio Timeout................................................................................................ 74
Tabella Numerica ........................................................................................... 75
SOMMAIRE
Description et Utilisation................................................................................. 30
Charge et Installation de la Batterie................................................................ 33
Compatibilité avec le Pistolet DLL6000-R....................................................... 34
Configuration DRAGON™ M/OM-DRAGON™ dans Systemes Stand Alone.. 34
Utilisation de Plusieurs Lecteurs pour une Meme Base.................................. 36
Configuration DRAGON™ M/STAR-Modem™ en Mode Stand Alone............. 37
Configuration DRAGON™ M/STAR-System™ ............................................... 38
DRAGON™ M – Configuration par Defaut...................................................... 40
Caracteristiques Techniques .......................................................................... 41
iv
Garantie.......................................................................................................... 42
Conformité...................................................................................................... 42
Abaques de Lecture........................................................................................ 71
Configuration du DLL6000-R .......................................................................... 72
Utilisation de Plusieurs Lecteurs pour une Meme Base.................................. 73
Radio Timeout................................................................................................ 74
Tableau Numérique........................................................................................ 75
INHALTSVERZEICHNIS
Beschreibung und Gebrauchsanweisung........................................................ 44
Ladung der Akkus........................................................................................... 47
DLL6000-R Kompatibilität............................................................................... 48
DRAGON™ M/OM-DRAGON™ Stand-Alone Konfiguration ........................... 48
Verbinden Mehrerer Leser mit Einer Station................................................... 50
DRAGON™ M/STAR-Modem™ im Stand-Alone Mode................................... 51
DRAGON™ M/STAR-System™ Konfiguration................................................ 52
DRAGON™ M Grundeinstellung..................................................................... 54
Technische Daten........................................................................................... 55
Gewährleistung............................................................................................... 56
Konformität..................................................................................................... 56
Lesefeldkurven............................................................................................... 71
DLL6000-R Konfiguration ............................................................................... 72
Verbinden Mehrerer Leser mit Einer Station................................................... 73
Radio Timeout................................................................................................ 74
Numerische Tabelle........................................................................................ 75
INDICE
Descripción y Utilización................................................................................. 58
Carga y Instalación de la Batería.................................................................... 61
Compatibilidad DLL6000-R............................................................................. 62
Configuración DRAGON™ M/OM-DRAGON™ para Sistemas
en Configuración Unitaria ............................................................................... 62
Utilización de Varios Lectores para una Misma Base ..................................... 64
DRAGON™ M/STAR-Modem™ en Modo de Configuración Unitaria.............. 65
CONFIGURACIÓN de DRAGON™ M/STAR-System™.................................. 66
DRAGON™ M – Configuración Predefinida.................................................... 68
Características Técnicas ................................................................................ 69
Garantia.......................................................................................................... 70
Conformidad................................................................................................... 70
Curvas de Respuesta Óptica.......................................................................... 71
Configuración del DLL6000-R......................................................................... 72
Utilización de Varios Lectores para una Misma Base ..................................... 73
Radio Timeout................................................................................................ 74
Tabla Numerica.............................................................................................. 75
1
DRAGON™ M SERIES
LASER GUNS
QUICK REFERENCE
DATALOGIC
2
UK/US
USING DRAGON™ M LASER GUNS
The DRAGON™ M series laser gun can be used with either an
OM-DRAGON™ cradle or STARGATE™ radio base station to build a Cordless
Reading System for the collection, decoding and transmission of barcoded
data.
DRAGON™ M is also completely compatible with the DLL6000-R/OM6010-R
Cordless Reading System.
DRAGON™ M laser guns automatically scan barcodes at a distance. Simply
aim and pull the trigger.
SCAN LINE POSITION
Code scanning is performed along the scan line emitted from the reading
window. This line must cross the entire code.
iBCDEFGHPk
iBCDEFGHPk
iBCDEFGHPk
OK
iPEJWKHL)k
iPEJWKHL)k
iPEJWKHL)k
NO
AIMING SYSTEM
DRAGON™ M provides a programmable aiming system. If enabled, the scan
line emitted from the reading window is preceded by a red spot which must
illuminate the code center to get the best reading performance (see figure
above, c). Once the defined timeout is reached, the red spot disappears and is
followed by the scan line to start the code scanning.
DRAGON™ M
3
UK/US
After Dragon™ M Setup, read one of the following codes to set desired aiming
system timeout. (Not available for DLL6000-R compatible applications).
aiming system disabled
i#9"k
i#9"k
i#9"k
300 ms
i#9'k
i#9'k
i#9'k
500 ms
i#9,k
i#9,k
i#9,k
1 sec
i#91k
i#91k
i#91k
READING ANGLE
Successful scanning is obtained by tilting the reader with respect to the
barcode to avoid direct reflections that impair the reading performance, see the
figure below.
OK Not Advised
DATALOGIC
4
UK/US
SETUP
DRAGON™ M/OM-DRAGON™ Stand Alone Configuration
1. Connect an OM-DRAGON™ cradle to the Host. For installation and
connection information see the OM-DRAGON™ Quick Reference
Manual.
2. Charge the DRAGON™ M battery using an OM-DRAGON™ or the
C-DRAGON™ charger as described in this Quick Reference manual. A
full charge takes 2 hours with NiMh battery models.
3. Configure the laser gun as described in this Quick Reference -
DRAGON™ M/OM-DRAGON™ Stand Alone Setup.
4. Configure the OM-DRAGON™ cradle. See OM-DRAGON™
Configuration in the OM-DRAGON™ Quick Reference.
or
DRAGON™ M/STAR-System™ Configuration
1. Charge the DRAGON™ M battery using an OM-DRAGON™ or the
C-DRAGON™ charger as described in this Quick Reference manual. A
full charge takes 2 hours with NiMh battery models.
2. Configure the laser gun as described in this Quick Reference -
DRAGON™ M/STAR-System™ Setup.
or
DRAGON™ M/DLL6000-R Compatibility
1. Charge the DRAGON™ M battery using an OM-DRAGON™/OM6010-
R or the C-DRAGON™/C6010 charger as described in this Quick
Reference manual. A full charge takes 2 hours with NiMh battery
models.
2. Read the DLL6000-R compatibility code in this Quick Reference -
DLL6000-R Compatibility.
3. Configure the laser gun as described in this Quick Reference –
DLL6000-R Configuration.
DRAGON™ M
5
UK/US
CHARGING THE BATTERIES
Once the OM-DRAGON™ is powered, you can charge the laser gun’s
batteries:
Place the DRAGON™ M into the OM-DRAGON™ cradle. The red LED on the
cradle goes on.
The battery is completely charged when the green LED on the cradle goes on.
After many
recharging cycles NiMh and NiCd batteries may tend to lose their
operating autonomy. This condition can be overcome by inserting the
DRAGON™ M into the OM-DRAGON™ / C-DRAGON™ charger and pressing the
“battery reconditioning” button (see below).
When the above procedure is no longer effective, the batteries must be
changed. To change the batteries of your laser gun, unscrew the battery cover
screw, replace the old batteries with new ones, then screw the battery cover
back into place. (See the following figures).
NiMh, NiCd or Alkaline
CAUTION
Dispose of used batteries as required by the relevant laws
in force.
Battery cover
screw
+
Battery
reconditioning
button
DATALOGIC
6
UK/US
DLL6000-R COMPATIBILITY
If it is necessary to use the DRAGON™ M reader in DLL6000-R applications,
full radio protocol and software compatibility is provided by reading the following
code:
Set DLL6000-R compatibility
i#:+k
i#:+k
i#:+k
The reader will automatically be switched off and restarted and four high tones
will be emitted.
At this point, the DRAGON™ M reader is ready to be configured using the
DLL6000-R procedure; refer to the DLL6000-R Quick Reference or System
Manual. For your convenience, the DLL6000-R configuration procedure is also
included at the end of this manual.
Do not use the DRAGON™ M configuration procedure.
To restore the DRAGON™ M standard configuration read the following code,
then follow the DRAGON™ M configuration procedure below:
Restore DRAGON™ M standard configuration
i#:&k
i#:&k
i#:&k
DRAGON™ M/OM-DRAGON™ STAND ALONE
SETUP
When the OM-DRAGON™ is connected and powered, configure the
DRAGON™ M by reading the following codes in the given sequence and follow
the instructions.
Note: for the numeric code selection use the table at the end of this Quick
Reference.
Restore DRAGON™ M default
1.
iPk
iPk
iPk
Enter configuration
2.
ik
ik
ik
DRAGON™ M
7
UK/US
Set Date
3.
i*"k
i*"k
i*"k
+
six digits for Day, Month and Year (DDMMYY).
Set Time
4.
i*#k
i*#k
i*#k
+
four digits for Hours and Minutes (HHMM).
Set Radio Address
5.
i3"3')k
i3"3')k
i3"3')k
+
four digits for the DRAGON™ M Address (from 0000 to 1999).
All guns must have different addresses.
Exit and Save configuration
6.
i k
i k
i k
7.
Read the Bind code to pair the DRAGON™ M to the OM-DRAGON™.
The reader is dedicated to the cradle. Any previously bound reader will
be excluded.
To connect several guns to the same cradle see the following section
Using Multiple Guns with Same Cradle'.
Bind
i3/*k
i3/*k
i3/*k
The green LED on the DRAGON™ M will blink: the gun is ready to be
inserted into the cradle.
DATALOGIC
8
UK/US
8.
Firmly insert the gun into the OM-DRAGON™ within 10 seconds; a beep
will be emitted, signaling that the OM-DRAGON™ has been paired to the
DRAGON™ M, and the green LED on the reader will go off.
YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE
DEFAULT VALUES.
9.
Configure the OM-DRAGON™ base, refer to the “OM-DRAGON™
Quick Reference”.
USING MULTIPLE GUNS WITH SAME CRADLE
If you want to use several DRAGON™ M guns with the same OM-DRAGON™
cradle, you must first Bind the cradle with one of the guns (see the previous
"DRAGON™ M/OM-DRAGON™ Stand Alone Setup" procedure).
Successive guns
can be associated with this same cradle by following the
configuration procedure substituting the Bind command with Join (step 7).
Join
7.
i3//k
i3//k
i3//k
The green LED on the DRAGON™ M will blink: the gun is ready to be
inserted into the cradle. Complete step 8.
END of procedure.
WARNING
If the cradle is not
bound to a gun, its address assumes a
random value which can cause conflicts and malfunctions
to other cradles within its range.
DRAGON™ M
9
UK/US
DRAGON™ M/STAR-MODEM™ IN STAND ALONE
MODE
To configure a DRAGON™ M reader to communicate with STAR-Modem™ in
Stand Alone Mode, follow the "DRAGON™ M/OM-DRAGON™ Stand Alone
Setup" procedure substituting steps 6 and 7 with those below:
STAR-Modem™ Address
6.
i343k
i343k
i343k
Read the code above and the four-digit address of the
STAR-Modem™.
7.
Exit and Save configuration
i k
i k
i k
END of procedure.
YOUR READER IS NOW READY TO READ BARCODES.
DATALOGIC
10
UK/US
DRAGON™ M/STAR-SYSTEM™ SETUP
The following procedure allows configuring a DRAGON™ M reader to
communicate with various STAR-System™ devices such as STARGATE™ RF
base stations:
Restore DRAGON™ M Default
1.
iPk
iPk
iPk
Enter Configuration
2.
ik
ik
ik
Set Date
3.
i*"k
i*"k
i*"k
+
six digits for Day, Month and Year (DDMMYY).
Set Time
4.
i*#k
i*#k
i*#k
+
four digits for Hours and Minutes (HHMM).
Set the connection according to the length of the codes to be read:
5.
Code Length
240 Characters
i3"Bk
i3"Bk
i3"Bk
Code Length >240 Characters
(not for systems with OM-DRAGON™ as Master)
i3"Ek
i3"Ek
i3"Ek
DRAGON™ M
11
UK/US
Set Radio Address
6.
i3'k
i3'k
i3'k
+
four digits from the Numeric Table in the range 0000-1999.
All guns must have different addresses.
Set First STAR-System™ Address
7.
i343k
i343k
i343k
+
four digits from the Numeric Table in the range 0000-1999.
Set Last STAR-System™ Address
8.
i355k
i355k
i355k
+
four digits from the Numeric Table in the range 0000-1999.
NOTE
Whenever the system is composed of a single base
station, the first and last base station addresses (steps 7
and 8) must have the same value.
Exit and Save Configuration
9.
i k
i k
i k
END of procedure.
YOUR READER IS NOW READY TO READ BARCODES.
DATALOGIC
12
UK/US
DRAGON™ M DEFAULT CONFIGURATION
DATA FORMAT
code identifier disabled, field adjustment disabled, code length not
transmitted, character replacement disabled, time stamping disabled, time
stamping delimiter disabled
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout, one read per cycle,
safety time 0.5 sec, beeper intensity high, tone 2, aiming spot = disabled
DISPLAY/KEYPAD PARAMETERS
Font size = small, display timeout = 8 sec., backlight = off, display mode =
local echo, keypad disabled, KeyID characters: left = '<', center = '=', right = '>'
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled,
decoding safety = one read, Puzzle Solver™ disabled
CODE SELECTION
enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length code; 4-99
characters
Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
variable length code; 1-99 characters
disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes,
Codablock-A, Codablock-F Standard and EAN, MSI, Plessey, Telepen,
Delta IBM, Code 11, Code 16K, Code 49
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours,
transmission mode = one-way, beeper control for radio response = normal,
single store disabled, batch mode disabled
DRAGON™ M
13
UK/US
TECHNICAL FEATURES
Electrical Features
Battery Type 2 AA NiMh* batteries
Time of recharge NiMh 2 hours
Operating autonomy
(typ. continuous reading)
60,000 reads - NiMh
Display
(Only available with some models)
LCD 4 lines x 16 chars
Programmable font and backlight
Indicators Laser On / battery low LED (red)
Programmable Beeper
Laser Features
Standard LR
Power (typical) in mW 0.9 mW 1.4 mW
Light Source VLD in the range between 630~680 nm
Scan rate 35 ± 5 scans/sec
Typical reading field width see reading diagram
Max. resolution 0.12 mm, 5 mils 0.25 mm, 10 mils
PCS minimum
(Datalogic Test Chart)
15% 40%
Scan angle 42° 23°
Laser Safety Class 2 (EN 60825-1 / CDRH)
Radio Features
European Models USA Models
Working frequency 433.92 MHz 910 MHz
Bit rate 19200 baud 36800 baud
Range (in open air) 50 m. 30 m.
System Configuration
OM-DRAGON™ STARGATE™ OM6010-R
Max. number of devices
per base station
32 255 32
Max. number of devices
in the same reading area
2000 127
Environmental Features
Working Temperature
-10 to + 40 °C / +14 to +104 °F
Storage Temperature
-20 to + 50 °C / -4 to +140 °F
Humidity 90% non condensing
Drop resistance
(on concrete)
with display
without display
1.5 m
1.8 m
Protection sealed against rain and dust
Mechanical Features
Weight (with batteries) about 340 g.
Dimensions 203 x 117 x 69 mm
Material ABS and Polycarbonate molded with rubber
* It is possible to employ also NiCd or non-chargeable Alkaline AA batteries.
DATALOGIC
14
UK/US
WARRANTY
Datalogic warranties this product against defects in workmanship and
materials, for a period of 24 months from the date of shipment, provided that
the product is operated under normal and proper conditions.
Datalogic has the faculty to repair or replace the product, these provisions do
not prolong the original warranty term.
The warranty does not apply to any product that has been subject to misuse,
accidental damage, unauthorized repair or tampering.
COMPLIANCE
This device must be opened by qualified personnel only.
The batteries must be removed before opening the device.
Modifications or changes to this equipment without expressed
written approval of Datalogic could void the authority to use the
equipment.
This device complies with PART 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference which may
cause undesired operation.
Contact the competent authority responsible for the management of radio
frequency devices of your country to verify the eventual necessity of a user
license.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for
further information.
!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

Datalogic DRAGON M SERIES Guide de référence

Catégorie
Radios
Taper
Guide de référence