Form No. CSRM-0220
13
English
INSTALLATION
General
Remote Built-In Cold Shelves are shipped from the factory as
components that require installation and connection. Use the
following information and procedures to prepare the unit and
the installation site.
NOTE: Make sure the installation location provides enough
room for the condensing unit and the remote mounted
control box.
WARNING
ELECTRIC SHOCK HAZARD:
• Units supplied without an electrical cord and plug
require a hardwired connection to on-site electrical
system. Connection must be properly grounded and
of correct voltage, size, and configuration for electrical
specifications of unit. Contact a qualified electrician to
determine and install proper electrical connection.
• Unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Installation by unqualified personnel
will void the unit warranty and may lead to electric
shock or burn, as well as damage to unit and/or its
surroundings. Check with local plumbing and electrical
inspectors for proper procedures and codes.
• Unit is not weatherproof. Locate unit indoors.
• Remote control box must be mounted on vertical wall
and installed in vertical position. Mounting remote
control box in horizontal position may result in
collection of liquids and lead to electric shock.
FIRE HAZARD: Install condensing unit with a minimum
of2″(51mm)ofspacebetweenallsidesofunitandany
combustible surfaces.
Locate the unit at the proper counter height in an area that is
convenient for use. The location should be level and strong
enough to support the weight of the unit and contents.
NOTICE
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
This unit is designed for use in environments where
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
When shipped during cold weather months, store unit
for at least 10 hours in an environment where ambient
temperature is between 65°F (18°C) and 86°F (30°C) to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warmup time.
Provide louvered or grill-style openings with a minimum
size of 12″ x 12″/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind the
condensing unit for proper ventilation. Failure to provide
adequate air flow through the condensing unit may cause
unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple
condensing units are installed together. Intake air should
enter from outside of cabinet.
NOTICE
Do not locate unit in area with excessive air movement
around unit. Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods, air
conditioning ducts, and exterior doors).
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Damage to any countertop material caused by heat or cold
generated from Hatco equipment is not covered under
the Hatco warranty. Contact manufacturer of countertop
material for application information.
All cold shelves are shipped in a shipping frame for protection
and stability. Keep the unit in the shipping frame until the unit
and the installation site are completely prepared for the unit to
be installed.
Survey the installation site. Take into account the need for
louvered or grill-style openings in the cabinetry to provide
proper ventilation for the condensing unit as well as access to
the control panel. One of these ventilation openings must be in
front of the condensing coils with the other on the opposite side.
If multiple condensing units are installed in the same counter,
each unit should intake cool air and expel hot air.
1. Remove all external packaging from the unit.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
2. Remove tape, protective packaging, and literature from all
surfaces of the unit.
Preparing the Installation Site
1. Prepare the appropriate opening and mounting bolt holes
in the countertop for the unit being installed.
• For top mounted CSBFR and CSBFX models, refer to
“Countertop Cutout Dimensions — Top Mounted Units,”
in this section.
• For bottom mounted CSSBR, CSSBFR, CSSBX, and
CSSBFX models, refer to “Countertop Cutout and
Mounting Bolt Dimensions — Bottom Mounted Units,”
in this section.
• For underside, surface mounted CSUR and CSUX
models, refer to “Mounting Bolt Dimensions—CSUR
and CSUX Models” in this section. Make sure the
countertop is a solid surface material with good heat
transfer characteristics, such as stainless steel, granite,
quartz, Corian
®
, etc... The thickness of the countertop
NOTE: The performance of each type of solid surface material
will vary dependant upon the material’s characteristics.
2. Cut and drill the appropriate holes in the vertical surface
where the control box will be installed. Refer to the
“Installing the Remote Control Box” procedure for cutout
dimensions.
• The installation depth required for the control box is
3. Make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents.
4. Install the unit. Refer to the appropriate procedure in this
section for the model being installed.