8.0 Voltage
8 to 14 VDC. 12 VDC at the reader is recommended for best operation.
9.0 Read Mode
For sector data reads, do not connect the Violet conductor (leave it high). For CSN reads, pull the Violet conductor low (connect the Violet
conductor to ground).
10.0 Connection
Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC
voltage source.
11.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times, and the LED will shine red.
2. Presenting a supported access credential will result in the reader beeping and the LED flashing once.
3. Mobile operation is optimized for smartphones supporting BLE (Bluetooth LE) version 4.2 or newer. Further, for the downloading of mobile
access credentials, a stable, high-quality internet connection is recommended.
NOTE: The access panel controls LED functionality, such as switching the LED to green.
If the reader does not recognize the mobile credential or card or tag (no beep, no LED flash) or exhibits short read range, please see the table
below for possible causes and solutions.
Possible Cause Corrective Action
Incorrect cabling Verify gauge, connections and cabling length
Not enough power 12 VDC recommended
Incorrect credential used Verify if credential technology is supported
Reader/access panel not properly grounded Earth ground needed—verify shield and reader ground are tied at access panel and connect
to ground at one point
Supply generating interference Linear power supply recommended, verify switching power supply before use
Should any of the corrective actions mentioned above not improve performance, disconnect the reader from the access panel and power it with a
separate power supply or 9VDC battery, and re-test card functionality. By powering the readers separately, most variables that may lead to
reduced performance can be eliminated. Should the problem persist, please contact Farpointe directly.
QUICK START GUIDE
NORTEK MOBILE-READY
CONTACTLESS SMARTCARD READERS
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by Farpointe Data could
void the user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions: (1) This device may not cause
interference. (2) This device must accept any interference, including interference that
may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2)
L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
© 2020 Farpointe Data, Inc. All rights reserved. Farpointe Data®, Pyramid
Series Proximity®, Delta®, Ranger®, and CONEKT® are the registered U.S.
trademarks of Farpointe Data, Inc. All other trademarks are the property of
their respective owners.
www.farpointedata.com
Farpointe Data, Inc.
2195 Zanker Road
San Jose, CA 95131 USA
Office: +1-408-731-8700
Fax: +1-408-731-8705
Farpointe Data reserves the right to
change specifications without notice.
Access Control Performance Levels:
Destructive
Attack
Line
Security Endurance
Standby
Power
Level II Level I Level IV Level I
Many Farpointe Data Readers carry the following certifications: