Hatco FTB, FTB-S Series Le manuel du propriétaire

Taper
Le manuel du propriétaire
P/N 07.04.568.00 © 2020 Hatco Corporation
Drop-In Frost Top Shelves
Plans réfrigérés de libre service
FTB and FTB-S Series/Séries
Installation and Operating Manual
Manuel d’installation et d’utilisation
Do not operate this equipment unless you
have read and understood the contents
of this manual! Failure to follow the
instructions contained in this manual
may result in serious injury or death.
This manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
WARNING
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en
este manual puede resultar en un serio
lesión o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted
no puede entender el contenido de
este manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
ADVERTENCIA
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel ! Le
non-respect des instructions contenues
dans ce manuel peut entraîner de
graves blessures ou la mort. Ce manuel
contient des informations importantes
concernant l’entretien, l’utilisation et le
fonctionnement de ce produit. Si vous ne
comprenez pas le contenu de ce manuel,
veuillez le signaler à votre supérieur.
Conservez ce manuel dans un endroit
sûr pour pouvoir vous y référer plus tard.
Français = p 15
AVERTISSEMENT
hatcocorp.com
Register Online!
(see page 2)
S’inscrire en ligne!
(voir page 15)
2
Form No. FTBM-0220
English
INTRODUCTION
Important Owner Information ..............................................2
Introduction ...........................................................................2
Important Safety Information ..............................................3
Model Description ................................................................4
Model Designation ...............................................................4
Specifications .......................................................................5
Plug Configuration ............................................................... 5
Electrical Rating Chart .........................................................5
Refrigerant Information ........................................................5
Dimensions .......................................................................... 6
Installation .............................................................................7
General ................................................................................ 7
Preparing the Unit for Installation ........................................ 7
Preparing the Installation Site .............................................8
Installing the Unit ................................................................. 8
Countertop Cutout Dimensions ...........................................9
Operation .............................................................................10
General .............................................................................. 10
Changing the Setpoint Temperature .................................. 11
Setting the Auto-Defrost Cycle(s) ...................................... 11
Changing Fahrenheit and Celsius Setting ......................... 11
Maintenance ........................................................................12
General .............................................................................. 12
Daily Cleaning ...................................................................12
Monthly Cleaning ...............................................................12
Troubleshooting Guide ......................................................13
Options and Accessories .................................................14
Limited Warranty ................................................................14
Authorized Parts Distributors ...........................Back Cover
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and purchase
date of the unit in the spaces below (specification label located
on bottom of unit and back of control panel). Please have this
information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. _________________________________________
Voltage ___________________________________________
Date of Purchase ___________________________________
Register your unit!
Completing online warranty registration will prevent delay in
obtaining warranty coverage. Access the Hatco website at
www.hatcocorp.com, select the Support pull-down menu,
and click on “Warranty”.
Business
Hours: 7:00  to 5:00  MondayFriday,
Central Time (CT)
(Summer Hours June to September:
7:00  to 5:00  MondayThursday
7:00  to 4:00  Friday)
Telephone: 800-558-0607; 414-671-6350
24 Hour 7 Day Parts and Service
Assistance available in the United States
and Canada by calling 800-558-0607.
Additional information can be found by visiting our web site at
www.hatcocorp.com.
Hatco Drop-In Frost Top Shelves are specially designed to hold
quick-turnaround, cold foods such as pre-chilled beverages,
snacks, hors d’oeuvres, and side dishes. The insulated, top-
mount units are designed for full-size sheet pans and are
available in 3/4, one, two, and three pan standard configurations
as well as two and three pan slim configurations.
All models are equipped with a condensing unit that can be
rotated to accommodate the installation location. For additional
installation flexibility, the condensing units on FTB-2, FTB-3,
FTB-S2, and FTB-S3 models also can be installed in several
positions along the bottom of the frost top enclosure using
pre-drilled holes. One year parts and on-site labor warranty is
standard.
Hatco Drop-In Frost Top Shelves are a product of extensive
research and field testing. The materials used were selected
for maximum durability, attractive appearance, and optimum
performance. Every unit is inspected and tested thoroughly
prior to shipment.
This manual provides the installation, safety, and operating
instructions for Drop-In Frost Top Shelves. Hatco recommends
all installation, operating, and safety instructions appearing in
this manual be read prior to installation or operation of a unit.
Safety information that appears in this manual is identified by
the following signal word panels:
WARNING
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to
personal injury.
CONTENTS
Form No. FTBM-0220
3
English
IMPORTANT SAFETY INFORMATION
WARNING
ELECTRIC SHOCK HAZARD:
Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
Turn OFF power switch and disconnect unit from power
source before performing any cleaning, adjustments,
or maintenance.
DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
This unit is not “jet-proof” construction. Do not use
jet-clean spray to clean this unit.
Discontinue use if power cord is frayed or worn.
Do not attempt to repair or replace a damaged power
cord. Cord must be replaced by Hatco, an Authorized
Hatco Service Agent, or a person with similar
qualifications.
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Use only Genuine Hatco Replacement Parts when
service is required. Failure to use Genuine Hatco
Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to
operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts
do not have the characteristics that will allow them to
operate safely in Hatco equipment.
FIRE HAZARD:
• Install unit with a minimum of 2″ (51 mm) of space
between all sides of the condensing unit and any
combustible surfaces.
Do not use flammable cleaning solutions to clean unit.
EXPLOSION HAZARD: Do not store or use gasoline or
other flammable vapors or liquids in the vicinity of this or
any other appliance.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
Make sure food product has been chilled to the proper
food-safe temperature before placing in unit. Failure to
chill food product properly may result in serious health
risks. This unit is for holding pre-chilled food product only.
Hatco Corporation is not responsible for actual food
product serving temperature. It is the responsibility of the
user to ensure that food product is held and served at a
safe temperature.
This unit is not intended for use by children or persons
with reduced physical, sensory, or mental capabilities.
Ensure proper supervision of children and keep them
away from the unit.
WARNING
Make sure all operators have been instructed on the safe
and proper use of the unit.
Maintain proper cleanliness of the unit. Proper cleanliness
and sanitation is critical for food-safe operation. Refer to
the MAINTENANCE section for cleaning procedures.
This unit has no “user-serviceable” parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
NOTICE
This unit is designed for use in environments where the
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
When shipped during cold weather months, store unit in
proper ambient temperature environment for 10 hours to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warm up time.
Provide louvered or grill-style openings with a minimum
size of 12″ x 12″/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind the
condensing unit for proper ventilation. Failure to provide
adequate air flow through the condensing unit may cause
unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple
refrigerated wells are installed together. Intake air should
enter from outside of cabinet.
Transport and install unit in upright position only. Failure
to do so may result in damage to the refrigeration system.
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch the finish of the unit,
marring its appearance and making it susceptible to soil
accumulation.
Do not use steel wool for cleaning. Steel wool will scratch
the finish.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean the unit.
This unit is intended for commercial use only—NOT for
household use.
Read the following important safety information before using this equipment to avoid serious
injury or death and to avoid damage to equipment or property.
4
Form No. FTBM-0220
English
MODEL DESCRIPTION
All Models
Hatco Drop-In Frost Top Shelves are reliable and versatile.
Each unit has an insulated, stainless steel and aluminized
steel housing. The bottom of the recessed frost top enclosure
is covered with a copper evaporator coil to provide even

enclosure is standard on all units except the FTB-3/4 and
FTB-1. Drop-In Frost Top Shelves are controlled by a digital
temperature controller and a Power I/O (on/off) Switch housed
in a single, remote-mountable control panel. The control panel
      

to the control panel provides power to the entire unit. All
models are designed to be mounted to the topside of various
types of countertop material including stainless steel, wood,
Corian, Swanstone, etc... Hatco Drop-In Frost Top Shelves
are designed, manufactured, and tested to maintain safe food
holding temperatures.
The ecoization logo identifies products designed to reflect
Hatco’s commitment to improving, protecting, and preserving
the global environment. Hatco Drop-In Frost Top Shelves
qualify for the ecoization logo through the use of eco-friendly
insulation as well as a highly efficient condensing unit.
FTB-X Models
FTB-X Models are available in 3/4, one, two, and three pan
configurations. These models orient full-size sheet pans in the
standard position with the short side facing the customer.
FTB-SX Models
FTB-SX Models are available in two and three pan
configurations. These models are “slim” designed and orient
full-size sheet pans with the long side facing the customer. The
slim design allows easy, reachable access to everything on the
frost top.
NOTE: Sheet Pans are available for the Drop-In Frost Top
Shelves. Refer to the OPTIONS AND ACCESSORIES
section in this manual for details.
F T B - S x
Frost Top
Drop-In
Full-Size Sheet Pan Capacity
No Character = Standard Depth
S = Slim Depth
Model FTB-S2
Model FTB-2
Pans not included.
Drop-In Frost Top Shelves (Models FTB-2 and FTB-S2 shown)
MODEL DESIGNATION
Form No. FTBM-0220
5
English
Model
Compressor
Size Volts Watts Amps PlugConguration
Shipping
Weight
FTB-3/4 1/5 hp 120 300 3.8 NEMA 5-15P 120 lbs. (54 kg)
FTB-1
1/5 hp 120 300 3.8 NEMA 5-15P
132 lbs. (60 kg)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-2
1/5 hp 120 300 3.8 NEMA 5-15P
180 lbs. (82 kg)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-3
1/5 hp 120 300 3.8 NEMA 5-15P
213 lbs. (97 kg)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-S2
1/5 hp 120 300 3.8 NEMA 5-15P
182 lbs. (83 kg)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-S3
1/5 hp 120 300 3.8 NEMA 5-15P
239 lbs. (109 kg)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
High Side Low Side
186 psig
(12.8 bar)
88 psig
(6.07 bar)
SPECIFICATIONS
NOTE: Shipping weight includes packaging.
NOTE: The specification labels are located on the bottom of the
unit and the back of the control panel. See the label for the
serial number and verification of unit electrical information.
Plug Configuration
Units are supplied from the factory with an electrical cord and
plug installed. Plugs are supplied according to the applications.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NEMA 5-15P
CEE 7/7 Schuko AS 3112
BS-1363
Plug Configuration
NOTE: Receptacle not supplied by Hatco.
Refrigerant Information
Hatco Drop-In Frost Top Shelves use R-513A refrigerant in the
condensing unit.
Electrical Rating Chart
The shaded areas contain electrical information for
International models only.
Design Pressure
Discharge
Pressure
Suction
Pressure Superheat Subcooling
115 to 125 psig
(7.9 to 8.6 bar)
6 to 9 psig
(0.4 to 0.6 bar)
4° to 10°F
(2.2° to 5.6°C)
5° to 10°F
(2.8° to 5.6°C)
Operating Specifications
NOTE: The Operating Specifications are accurate for units in an ambient
air temperature of 75°F (24°C).
6
Form No. FTBM-0220
English
Model
Width
(A)
Depth
(B)
Overall
Height (C)
Enclosure
Height (D)
FTB-3/4
21-1/16
(535 mm)
18
(457 mm)
23-3/4
(604 mm)
3-9/16
(90 mm)
FTB-1
21-1/16
(535 mm)
28-15/16
(735 mm)
17-1/8
(433 mm)
3-9/16
(90 mm)
FTB-2
39
(991 mm)
28-15/16
(735 mm)
17-1/4
(437 mm)
3-9/16
(90 mm)
FTB-3
57
(1448 mm)
28-15/16
(735 mm)
17-3/4
(450 mm)
3-9/16
(90 mm)
Model
Width
(A)
Depth
(B)
Overall
Height (C)
Enclosure
Height (D)
FTB-S2
54-15/16
(1395 mm)
21-1/16
(535 mm)
17-1/4
(437 mm)
3-9/16
(90 mm)
FTB-S3
80-13/16
(2053 mm)
21-1/16
(535 mm)
17-1/4
(437 mm)
3-9/16
(90 mm)
SPECIFICATIONS
Dimensions — FTB Models
Dimensions — FTB-S Models
A B
C
D
Front View Side View
Dimensions—FTB Model
Form No. FTBM-0220
7
English
INSTALLATION
General
Drop-In Frost Top Shelves are shipped from the factory
completely assembled and ready for use. Use the following
information and procedures to prepare the unit and installation
site as well as to install the unit.
WARNING
ELECTRIC SHOCK HAZARD:
Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
Unit is not weatherproof. Locate unit indoors.
FIREHAZARD:Installunitwithaminimumof2″(51mm)
of space between all sides of the condensing unit and any
combustible surfaces.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
NOTICE
Transport and install unit in upright position only. Failure
to do so may result in damage to the refrigeration system.
When shipped during cold weather months, store unit in
proper ambient temperature environment for 10 hours to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warm up time.
This unit is designed for use in environments where the
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
Provide louvered or grill-style openings with a minimum size
of12″x12″/144squareinches(31x31cm/961squarecm)
in the cabinetry in front of and behind the condensing unit
for proper ventilation. Failure to provide adequate air flow
through the condensing unit may cause unit failure and will
void the unit warranty.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
All Drop-In Frost Top Shelves are shipped in a shipping frame
for protection and stability. Keep the unit in the shipping frame
until the unit and the installation site are completely prepared
for the unit to be installed.
1. Remove all external packaging from the unit.
2. Remove tape, protective packaging, and literature from all
surfaces of unit.
NOTE: To prevent delay in obtaining warranty coverage, complete
online warranty registration. See the IMPORTANT
OWNER INFORMATION section for details.
Preparing the Unit for Installation
The orientation of the condensing unit on all FTB models can
be adjusted to match the layout of the installation site. It can
be rotated 90° or 180° from its factory-installed position. On
FTB-3, FTB-S2, and FTB-S3 models, the condensing unit
can be installed in several positions along the bottom of the

increments. The condensing unit on FTB-2 models can be

Survey the installation site and determine if adjustment to
the orientation and/or position of the condensing unit is
necessary. Take into account the need for louvered or grill-style
openings in the cabinetry to provide proper ventilation for the
condensing unit as well as access to the control panel. One of
these ventilation openings must be in front of the condensing
coils with the other on the opposite side. If adjustment to the
orientation and/or position of the condensing unit is necessary,
use the following procedure(s).
Rotating the Condensing Unit
This procedure can be performed on all FTB models.
1. Place blocks underneath the condensing unit for support
during rotation.
2. Remove the 4 mounting screws that secure the condensing
unit support frame to the underside of the frost top enclosure.
3. Rotate the condensing unit 90° or 180°, depending on the
installation site.
NOTE: Do not rotate the condensing unit in a direction that will
put the evaporator lines or any other obstruction in front
of the condenser coil.
4. Reattach the condensing unit support frame to the underside
of the frost top enclosure using the 4 mounting screws.
Hoses removed
for clarity.
Mounting
Screw
Condensing Unit
Support Frame
Condensing Unit
rotated 90°.
Rotating the Condensing Unit
8
Form No. FTBM-0220
English
INSTALLATION
Moving the Condensing Unit
This procedure can be performed on FTB-2, FTB-3, FTB-S2,
and FTB-S3 models only.
1. Remove the four mounting screws that secure the
condensing unit support frame to the underside of the frost
top enclosure.
2. Move the condensing unit to the desired position. The
condensing unit can be installed in several positions along
the bottom of the frost top enclosure using pre-drilled holes

3. Reattach the condensing unit support frame to the frost
top enclosure using the four mounting screws.
Mounting
Screw
Condensing Unit Moved to Opposite End
Condensing Unit in End Position
Moving a Condensing Unit
Preparing the Installation Site
1. Cut the appropriate opening in the countertop for the unit
being installed. Refer to “Countertop Cutout Dimensions”
in this section.
2. If installing the control panel remotely, cut and drill the
appropriate holes in the vertical surface where the control
panel will be installed. Refer to the “Installing the Control
Panel Remotely” procedure for cutout dimensions.
3. Make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents. Make sure a minimum
        
condensing unit and any interior surface.
NOTE: The countertop must be level to ensure proper draining
of the frost top enclosure.
4. Cut two openings in the cabinetry to provide proper ventilation
for the condensing unit. Louvered or grill-style panels should
be installed in the openings to protect the condensing unit.

or 144 square inches (961 square cm).
One opening should be located in front of the condenser
coils with the other opening on the opposite side.
NOTE: Ducting may be required to ensure proper ventilation
inside the cabinet.
5. Make sure a grounded electrical receptacle of the correct
     
mm) of the mounting location for the control panel. See
the SPECIFICATIONS section for details.
Installing the Unit
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Lift the unit out of the shipping frame and carefully lower it
into the countertop cutout. This step requires two or more
people, depending on the unit.
2. Apply National Sanitation Foundation-approved (NSF-
approved) silicone sealant around the edge of the unit to
seal it to the countertop.
3. Install the control panel in the desired location.
The control panel can be installed on one of three sides
of the condensing unit support frame. Do not install the
control panel in front of the condenser coils.
The control panel can be installed remotely within 48”
(1219 mm) of the condensing unit. Refer to the “Installing
the Control Panel Remotely” procedure in this section.
 
(except FTB-3/4 and -1 models). If a trap and drain line
are not available, a catch pan (not supplied) must be used
under the drain fitting to contain water draining from the
frost top enclosure.
NOTE: Consult a qualified plumber for proper trap and drain
installation that conforms to local plumbing codes.
Air Flow
Air Flow
r
Installing a FTB-2
5. Clean the frost top enclosure thoroughly in preparation for
initial operation. Refer to the MAINTENANCE section for
proper cleaning procedures.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the pan is emptied regularly to prevent over-flowing.
6. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Form No. FTBM-0220
9
English
Model
Width
(A)
Depth
(B)
FTB-3/4
19-7/16 to 20-1/8
(494 to 511 mm)
16-1/2 to 17-1/16
(419 to 433 mm)
FTB-1
19-7/16 to 20-1/8
(494 to 511 mm)
27-7/16 to 28
(697 to 711 mm)
FTB-2
37-3/8 to 38
(949 to 965 mm)
27-5/16 to 28
(694 to 711 mm)
FTB-3
55-3/8 to 56
(1407 to 1422 mm)
27-5/16 to 28
(694 to 711 mm)
Model
Width
(A)
Depth
(B)
FTB-S2
53-5/16 to 54
(1354 to 1372 mm)
19-7/16 to 20-1/8
(494 to 511 mm)
FTB-S3
79-3/16 to 79-7/8
(2011 to 2029 mm)
19-7/16 to 20-1/8
(494 to 511 mm)
INSTALLATION
FTB-3
FTB-S2
B
B
A
A
Countertop Cutout Dimensions
FTB and FTB-S Series Countertop Cutout Dimensions.
Installing the Control Panel Remotely
Use the following procedure to install the control panel
remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the “Control Panel Cutout and Screw Hole
Dimensions” chart for the cutout dimensions.
2. Remove the control box from the unit by removing the
bolts on the side of the condensing unit.
3. Remove the four trim cover screws from the control box
and remove the trim cover.
4. Remove the bracket from the control box by unscrewing
the four bracket screws.
5. Position the control box into the cutout opening from the
backside.
6. Fasten the control box to the vertical surface using four
screws (not supplied).
 
where the trim cover will contact the cabinet surface. Refer
to the “Control Panel Cutout and Screw Hole Dimensions”
illustration for more information.
8. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16″
(11 mm)
3/8″
(9 mm)
Silicone Sealant
5-5/8″
(143 mm)
7-7/16″
(189 mm)
7-3/4″
(196 mm)
3-1/2″
(89 mm)
1-1/16″
(27 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.
10
Form No. FTBM-0220
English
OPERATION
General
Use the following procedures to operate a Drop-In Frost Top
Shelf.
WARNING
Read all safety messages in the Important Safety
Information section before operating this equipment.
Make sure food product has been chilled to the proper
food-safe temperature before placing in the unit. Failure
to chill food product properly may result in serious health
risks. This unit is for holding pre-chilled food product only.
NOTICE
When shipped during cold weather months, store unit in
proper ambient temperature environment for 10 hours to
prevent compressor and/or refrigerant line damage. If unit
is turned on and there is excessive noise and vibration,
turn off immediately and allow additional warm up time.
This unit is designed for use in environments where the
ambient temperature is between 65°F (18°C) and 86°F
(30°C).
NOTE: If the display flashes “OFF” and then the current
temperature, press and hold the key for three
seconds. The display will no longer flash “OFF”.
If the display flashes “df” and then the current
temperature, press and hold the key for three
seconds. The display will no longer flash “df”.
Startup
1. Move the Power I/O (on/off) Switch to the I (on) position
(located on the control panel).
The digital temperature controller will energize and
“ON” will appear on the display, followed by the current
temperature of the unit.
• The symbol on the display will illuminate to show
the condensing unit is active and chilling the frost top.
NOTE: The unit is pre-set at the factory to a setpoint
temperature of 25°F (-4°C). If ambient conditions
require adjustment to the setpoint temperature, refer
to the “Changing the Setpoint Temperature” in this
section.
Digital Temperature
Controller
Power I/O(On/Off) Switch
Unit “Active”
Symbol
FTB Series Control Panel
2. Allow the unit approximately 30 minutes to reach the
setpoint temperature before loading pre-chilled food
product.
3. Verify on the display that the unit has reached the proper
setpoint temperature, and load the frost top with food pans
that contain pre-chilled food product.
Always use a food pan. Do not place food directly into
the frost top.
Stir thick food items frequently to keep food chilled
uniformly.
WARNING
Hatco Corporation is not responsible for the actual food
product serving temperature. It is the responsibility of the
user to ensure that the food product is held and served at
a safe temperature.
Shutdown
1. Move the Power I/O (on/off) Switch to the O (off) position.
The digital temperature controller and condensing unit will
shut off.
2. Perform the “Daily Cleaning” procedure in the
MAINTENANCE section of this manual.
NOTICE
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
NOTE: If a catch pan is used underneath the drain fitting,
make sure the pan is emptied regularly to prevent over-
flowing.
Form No. FTBM-0220
11
English
OPERATION
Changing the Setpoint Temperature
Use the following procedure to change the setpoint temperature
on the digital temperature controller.
NOTE: Changes to the setpoint temperature should be made
in small increments (1 to 2 degrees). Wait at least two
hours after a change in setpoint temperature before
checking for the desired result.
1. Press and hold the key for one second until the
display flashes the current setpoint temperature.
2. Press the or key to increase or decrease the
setpoint temperature. If no key is pressed within 60
seconds, the display will revert to normal operation and
the current temperature of the unit will be shown on the
display.
3. Press the key to lock in the new setpoint temperature.
The display will revert to show the current temperature of
the unit.
Display
Down Arrow/
Defrost Key
Unit
“Active”
Symbol
Up Arrow/
Standby Key
SET
Key
Digital Temperature Controller
NOTE: If the display flashes “OFF” and then the current
temperature, press and hold the key for three
seconds. The display will no longer flash “OFF”.
If the display flashes “df” and then the current
temperature, press and hold the key for three
seconds. The display will no longer flash “df”.
Setting the Auto-Defrost Cycle
Hatco Refrigerated Wells are programmed at the factory with
the auto-defrost cycle deactivated. Use the following procedure
to activate the auto-defrost cycle if ambient or operational
conditions require the unit to defrost occasionally. When the
unit is in a defrost cycle, will appear on the display.
1. Press and hold the key for three seconds to access
programming mode. “PS” (password) will appear on the
display.
2. Press the key again. A numeric value will appear on
the display.
3. Press the or key until the number “22” appears
on the display, then press the key.
4. Use the or key to scroll through the programmable
parameters until “dI” (defrost interval) appears on the
display.
5. Press the key to select “dI”. The current number of
defrost cycles will be shown on the display. For new units,
this value will be “0”.
6. Press the or key within 60 seconds to scroll to
the desired number of hours between defrost cycles. See
below for examples of how the defrost cycle(s) operate:
“0” = auto-defrost is deactivated
“1” = unit will defrost every hour
“4” = unit will defrost every four hours
“12” = unit will defrost every twelve hours
If no key is pressed within 60 seconds, the display will
revert to normal operation and the current temperature of
the unit will be shown on the display.
7. Press the key to lock in the new defrost cycle setting.
8. Press and hold the key for three seconds to exit
programming mode. The display will revert to show the
current temperature of the unit.
Changing Fahrenheit and Celsius Setting
Use the following procedure to change between Fahrenheit and
Celsius on the display.
1. Press and hold the key for three seconds to access
programming mode. “PS” (password) will appear on the
display.
2. Press the key again. A numeric value will appear on
the display.
3. Press the or key until the number “22” appears
on the display, then press the key.
4. Use the or key to scroll through the programmable
parameters until appears on the display.
5. Press the key to select .
6. Press the or key within 60 seconds to scroll to
the desired setting. See below for the correct setting:
“0” = Displays Celsius
“1” = Displays Fahrenheit
If no key is pressed within 60 seconds, the display will
revert to normal operation and the current temperature of
the unit will be shown on the display.
7. Press the key to lock in the new setting.
8. Press and hold the key for three seconds to exit
programming mode. The display will revert to show the
current temperature of the unit.
12
Form No. FTBM-0220
English
MAINTENANCE
General
Hatco Drop-In Frost Top Shelves are designed for maximum
durability and performance, with minimum maintenance.
WARNING
ELECTRIC SHOCK HAZARD:
Turn OFF power switch and disconnect unit from power
source before performing any cleaning, adjustments,
or maintenance.
DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
FIRE HAZARD: Do not use flammable cleaning solutions
to clean this unit.
This unit has no “user-serviceable” parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
NOTICE
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Do not use steel wool for cleaning. Steel wool will scratch
the finish.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch the finish of the unit,
marring its appearance and making it susceptible to soil
accumulation.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean this unit.
Daily Cleaning
1. Move the Power I/O (on/off) Switch to the O (off) position
and allow the unit to defrost.
NOTE: If a catch pan is used underneath the drain fitting,
make sure the pan is emptied regularly to prevent over-
flowing.
2. Remove and wash any pans.
3. Clean the frost top using a damp cloth or sponge and
mild detergent. Use a plastic scouring pad to remove any
hardened food particles or mineral deposits.
4. Wipe down the frost top with a non-abrasive, sanitized
cloth to remove the detergent residue. Repeat until all
detergent residue is gone and the frost top is clean.
5. Wipe dry the entire unit using a non-abrasive, dry cloth.
6. Wipe down the outside of the louvered or grill-style panels
installed in the ventilation openings.
Monthly Cleaning
Perform the following procedure monthly to maintain proper
and efficient operation of the Drop-In Frost Top Shelf as well
as prevent malfunction.
1. Remove and clean both sides of the louvered or grill-style
panels that are installed in the ventilation openings. Dirt
and dust build-up in the panels can restrict air flow to the
condensing unit and cause over-heating.
2. Clean the condenser coil cooling fins. Dirt, dust, and lint
build-up in the cooling fins will prevent proper cooling of
the refrigerant in the refrigeration system. This buildup will
cause inefficient operation and can lead to unit failure. Use
the following methods to clean the condenser coil cooling
fins:
Vacuum the cooling fins.
Brush the cooling fins vertically using a condenser
coil brush. NOTICE: Use caution when brushing
the cooling fins, they are delicate and can be bent
easily. DO NOT use a wire brush.
Condenser Coil
Cooling Fins
Condenser Coil Cooling Fins
NOTE: Depending on the conditions of the installation site, this
cleaning procedure may need to be performed more
often or less often than monthly. Monitor the level of dirt,
dust, and lint buildup on the panels and cooling fins,
and make adjustments to the frequency of cleanings as
necessary.
Form No. FTBM-0220
13
English
Symptom Probable Cause Corrective Action
Unit too cold. Setpoint temperature too low. Adjust the setpoint temperature to a higher setting. Refer to
the “Changing the Setpoint Temperature” procedure in the
OPERATION section.
Digital temperature controller not working
properly.
Contact Authorized Service Agent or Hatco for assistance.
Unit not cold enough. Food product not pre-chilled before loading
in unit.
Load unit with pre-chilled food product only.
Setpoint temperature set too high. Adjust the setpoint temperature to a lower setting. Refer to
the “Changing the Setpoint Temperature” procedure in the
OPERATION section.
Condenser coil and/or ventilation panels are
plugged.
Clean the condenser coil and ventilation panels. Refer to
the “Monthly Cleaning” procedure in the MAINTENANCE
section.
Too much frost built up inside of unit. Turn off, defrost, and clean the unit. Activate an auto-defrost
cycle, if necessary (refer to the “Setting the Auto-Defrost
Cycle” procedure in the OPERATION section).
Digital temperature controller not working
properly.
Contact Authorized Service Agent or Hatco for assistance.
Refrigerant low/leaking or other internal
condensing unit malfunction.
Unit makes excessive noise
and vibration when turned on.
Internal components have not been adequately
warmed before operation.
Turn off unit immediately. Unit should be stored in a warm
environment of 65°F (18°C) for at least 10 hours.
Controller display flashes
“OFF” and unit is not working.
The unit is in Standby mode.
Press and hold the key for three seconds. The display
will no longer flash “OFF”.
Controller display flashes “df”
and unit is not working.
The unit is in Defrost mode.
Press and hold the key for three seconds. The display
will no longer flash “df”.
Unit plugged in, but not
working.
Unit turned off. Turn on unit.
Circuit breaker tripped. Reset circuit breaker. If circuit breaker continues to trip,
contact Authorized Service Agent or Hatco for assistance.
Digital temperature controller not working
properly.
Contact Authorized Service Agent or Hatco for assistance.
Condensing unit overheated.
Internal condensing unit malfunction.
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch and
disconnect unit from power source before performing any
cleaning, adjustments, or maintenance.
TROUBLESHOOTING GUIDE
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on “Find A Service Agent”; or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
14
Form No. FTBM-0220
English
1. PRODUCT WARRANTY
Hatco warrants the products that it manufactures (the “Products”)
to be free from defects in materials and workmanship, under
normal use and service, for a period of one (1) year from the
date of purchase when installed and maintained in accordance
with Hatco’s written instructions or 18 months from the date
of shipment from Hatco. Buyer must establish the Product’s
purchase date by registering the Product with Hatco or by other
means satisfactory to Hatco in its sole discretion.
Hatco warrants the following Product components to be free
from defects in materials and workmanship from the date of
purchase (subject to the foregoing conditions) for the period(s)
of time and on the conditions listed below:
a) One (1) Year Parts and Labor PLUS One (1) Additional
Year Parts-Only Warranty:
Conveyor Toaster Elements (metal sheathed)
Drawer Warmer Elements (metal sheathed)
Drawer Warmer Drawer Rollers and Slides
Strip Heater Elements (metal sheathed)
Display Warmer Elements (metal sheathed air heating)
Holding Cabinet Elements (metal sheathed air heating)
Heated Well Elements — HW and HWB Series
(metal sheathed)
b) Two (2) Year Parts and Labor Warranty:
Induction Ranges
Induction Warmers
c) One (1) Year Parts and Labor PLUS Four (4) Years
Parts-Only Warranty:
3CS and FR Tanks
d) One (1) Year Parts and Labor PLUS Nine (9) Years
Parts-Only Warranty on:
Electric Booster Heater Tanks
Gas Booster Heater Tanks
e) Ninety (90) Day Parts-Only Warranty:
Replacement Parts
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND
IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE OR PATENT OR OTHER
INTELLECTUAL PROPERTY RIGHT INFRINGEMENT.
Without limiting the generality of the foregoing, SUCH
WARRANTIES DO NOT COVER: Coated incandescent light
bulbs, fluorescent lights, heat lamp bulbs, coated halogen light
bulbs, halogen heat lamp bulbs, xenon light bulbs, LED light
tubes, glass components, and fuses; Product failure in booster
tank, fin tube heat exchanger, or other water heating equipment
caused by liming, sediment buildup, chemical attack, or
freezing; or Product misuse, tampering or misapplication,
improper installation, or application of improper voltage.
2. LIMITATION OF REMEDIES AND DAMAGES
Hatco’s liability and Buyer’s exclusive remedy hereunder will
be limited solely, at Hatco’s option, to repair or replacement
using new or refurbished parts or Product by Hatco or a Hatco-
authorized service agency (other than where Buyer is located
outside of the United States, Canada, United Kingdom, or
Australia, in which case Hatco’s liability and Buyer’s exclusive
remedy hereunder will be limited solely to replacement of part
under warranty) with respect to any claim made within the
applicable warranty period referred to above. Hatco reserves
the right to accept or reject any such claim in whole or in part. In
the context of this Limited Warranty, “refurbished” means a part
or Product that has been returned to its original specifications
by Hatco or a Hatco-authorized service agency. Hatco will not
accept the return of any Product without prior written approval
from Hatco, and all such approved returns shall be made
at Buyer’s sole expense. HATCO WILL NOT BE LIABLE,
UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES, INCLUDING BUT NOT LIMITED
TO LABOR COSTS OR LOST PROFITS RESULTING FROM
THE USE OF OR INABILITY TO USE THE PRODUCTS OR
FROM THE PRODUCTS BEING INCORPORATED IN OR
BECOMING A COMPONENT OF ANY OTHER PRODUCT
OR GOODS.
OPTIONS AND ACCESSORIES
Food Pans
Accessory food pans are available in various sizes.
ALUM PAN ............ Half-size aluminum sheet pan —

18″SHEETPAN ....Full size aluminum sheet pan —

Full Sheet Pan
(18″SHEET PAN)
Half-Size Sheet Pan
(ALUM PAN)
Food Pans
LIMITED WARRANTY
Formulaire n° FTBM-0220
15
Français
INTRODUCTION
Informations Importantes pour le Propriétaire ................15
Introduction .........................................................................15
Consignes de Sécurité Importantes ................................. 16
Description du Modèle .......................................................17
Désignation du Modèle ...................................................... 18
Caractéristiques Techniques ............................................18
Configuration des Fiches ...................................................18
Tableau des valeurs nominales électriques ......................18
Information sur le fluide frigorigène ................................... 18
Dimensions ........................................................................ 19
Installation ...........................................................................20
Généralités ........................................................................20
Préparer l’appareil pour installation ...................................20
Préparer le lieu d’installation .............................................21
Installer l’appareil ...............................................................21
Dimensions de découpe du comptoir ................................ 22
Mode d’emploi ....................................................................23
Généralités ........................................................................23
Modifier la température nominale ......................................24
Programmer le cycle de dégivrage automatique...............24
Alternance entre l’affichage Fahrenheit et Celsius ............24
Maintenance ........................................................................25
Généralités ........................................................................25
Nettoyage quotidien ...........................................................25
Nettoyage mensuel ............................................................25
Guide de Dépannage ..........................................................26
Options et Accessoires .....................................................27
Garantie Limitée .................................................................27
Autorisés Distributeurs de Pièces ........Couverture Arrière
INFORMATIONS IMPORTANTES POUR LE PROPRIÉTAIRE
Noter le numéro de modèle, le numéro de série , le voltage
et la date d’achat de votre appareil ci-dessous (l’étiquette
comportant les caractéristiques techniques se situe sous
l’appareil et à l’arrière du panneau de contrôle). Veuillez avoir
cette information à portée de la main si vous appelez Hatco
pour assistance.
Modèle No. _______________________________________
Numéro de série ___________________________________
Voltage __________________________________________
Date d’achat ______________________________________
Enregistrez votre appareil!
Remplissez la garantie en ligne pour éviter les retards
pour faire jouer la garantie. Accédez au site Web Hatco
www.hatcocorp.com, sélectionnez le menu déroulant
Support (Assistance), puis cliquez sur « Warranty » (Garantie).
Horaires
ouvrables : 7h00 à 17h00 du lundi au vendredi
Heure du Centre (CT)
(Horaires d’été—juin à septembre:
7h00 à 17h00 du lundi au jeudi
7h00 à 16h00 le vendredi)
Téléphone: 800-558-0607; 414-671-6350
Service d'assistance et de pièces de
rechange disponible 7j/7, 24h/24 aux
États-Unis et au Canada en composant
le 800-558-0607.
Des renseignements supplémentaires sont disponibles sur
notre site Web à www.hatcocorp.com.
Les plans réfrigérés de libre service Hatco sont spécialement
conçus pour les aliments froids de libre service rapide, tels
que des boissons froides, des collations, des hors d’œuvres
et des plats d’accompagnement. Les appareils s’encastrent
sur le dessus d’un meuble, sont isolés et sont conçus pour
accueillir des grands plateaux fins. En configuration standard,
ils peuvent accueillir 3/4, un, deux ou trois plateaux, et deux ou
trois en configuration allongée.
Tous les modèles sont équipés d’un groupe compresseur-
condenseur qui peut pivoter pour s’adapter au lieu
d’installation. Pour plus de flexibilité lors de l’installation, les
groupes compresseur-condenseur des modèles FTB-2, FTB-3,
FTB-S2 et FTB-S3 peuvent aussi être installés dans différentes
positions contre la partie inférieure de la cuve du plan réfrigéré
à l’aide des orifices pré-percés. La garantie d’un an pour les
pièces ainsi que pour la main d’œuvre sur place est standard.
Les plans réfrigérés de libre service Hatco sont le produit
d’une recherche avancée et d’essais pratiques. Les matériaux
utilisés ont été sélectionnés pour une durabilité maximale, une
apparence attractive et des performances optimales. Chaque
appareil est soigneusement inspecté et testé avant expédition.
Ce manuel fournit les instructions d’installation, de sécurité et
d’utilisation pour les plans réfrigérés de libre service Hatco.
Hatco vous recommande de lire l’ensemble des instructions
d’installation, de sécurité et de fonctionnement contenues dans
ce manuel avant d’installer et d’utiliser l’appareil.
Les consignes de sécurité qui apparaissent dans ce manuel
sont identifiées par les mots indicateurs suivants :
AVERTISSEMENT
AVERTISSEMENT indique une situation dangereuse qui,
si elle n’est pas évitée, peut provoquer la mort ou des
blessures graves.
ATTENTION
ATTENTION indique une situation dangereuse qui, si elle
n’est pas évitée, peut provoquer des blessures légères ou
moyennes.
AVIS
AVIS est utilisé pour des questions sans rapport avec des
blessures corporelles.
SOMMAIRE
16
Formulaire n° FTBM-0220
Français
CONSIGNES DE SÉCURITÉ IMPORTANTES
AVERTISSEMENT
DANGER DE DÉCHARGE ÉLECTRIQUE :
Brancher l’appareil sur une prise de courant avec terre
de tension, de format et de configuration des broches
corrects. Si la fiche et la prise ne se correspondent pas,
s’adresser à un électricien qualifié pour déterminer et
installer une prise de courant de format et de tension
corrects.
Mettez l’unité hors tension depuis l’interrupteur et
débranchez le cordon d’alimentation avant d’effectuer
tout nettoyage, tout réglage ou tout entretien.
• L’unité n’est pas étanche. Il doit être installé en
intérieur.
NE PAS immerger l’appareil ni le saturer d’eau.
L’appareil n’est pas étanche à l’eau. Ne pas le faire
fonctionner s’il a été immergé ou saturé d’eau.
Cet appareil n’est pas étanche aux jets. Ne pas utiliser
de jet sous pression pour nettoyer l’appareil.
Ne pas utiliser l’appareil si le cordon est endommagé
ou usé.
Ne pas tenter de réparer ni de changer un cordon
électrique endommagé. Ce cordon doit être changé
par Hatco, par un réparateur Hatco agréé ou par une
personnes de qualifications comparables.
La réparation de cet appareil doit être confiée
exclusivement à du personnel qualifié. Les réparations
par des personnes non qualifiées peuvent provoquer
des décharges électriques et des brûlures.
Pour les réparations, utiliser exclusivement des pièces
de rechange Hatco d’origine. Utilisez des pièces
détachées Hatco authentiques sous peine d’annuler
toutes les garanties et d’exposer l’utilisateur à des
tensions électriques dangereuses pouvant entraîner
une électrocution ou des brûlures. Les pièces
de rechange Hatco d’origine sont conçues pour
fonctionner sans danger dans les environnements
dans lesquels elles sont utilisées. Certaines pièces
de rechange génériques ou de second marché ne
présentent pas les caractéristiques leur permettant de
fonctionner sans danger dans la matériel Hatco.
DANGER D’INCENDIE :
Lors de l’installation, un espace minimum de 51 mm
(2″) doit être maintenu entre les parois du groupe
compresseur-condenseur et toute surface combustible.
• N’utilisez pas des solutions nettoyantes inflammables
pour nettoyer cet appareil.
RISQUE D’EXPLOSION: Ne conservez pas ou n’utilisez pas
d’essence ou d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre appareil.
L’élément doit être installé par des installateurs formés
et qualifiés. L’installation doit être conforme à toutes
les normes électriques et de plomberie locales. Vérifiez
les procédures et les normes à suivre auprès de vos
inspecteurs locaux en plomberie et en électricité.
AVERTISSEMENT
Assurez-vous que les aliments ont été correctement
réfrigérés à une température appropriée avant de les placer
dans l’appareil. Maintenir des aliments à une température
inappropriée peut entraîner des risques graves pour la
santé. Cet appareil est uniquement destiné à maintenir
frais des aliments préalablement réfrigérés.
Hatco Corporation n’est pas responsable de la température
réelle à laquelle les aliments sont servis. Il est de la
responsabilité de l’utilisateur de s’assurer que la nourriture
est conservée et servie à une température sans danger.
Assurez-vous que tous les opérateurs ont été formés à
l’utilisation sûre et correcte de l’appareil.
Cet appareil ne doit pas être utilisé par des enfants ou des
personnes avec des capacités physiques, sensorielles ou
mentales diminuées. Assurez-vous que les enfants sont
bien surveillés et tenez-les à l’écart de l’appareil.
L’appareil doit être maintenu dans un état de propreté
correct. Des bonnes conditions de propreté et d’hygiène
sont essentielles à une manipulation saine des aliments.
Reportez-vous à la section MAINTENANCE pour consulter
les procédures de nettoyage.
Cet appareil ne contient aucune pièce réparable par
l’utilisateur. Si cet appareil doit être réparé, contacter un
réparateur Hatco agréé ou le Service après-vente Hatco au
800-558-0607 ou 414-671-6350.
ATTENTION
Placez l’appareil à une hauteur de comptoir adaptée
et sur un emplacement pratique pour son utilisation.
L’emplacement choisi doit être de niveau et solide afin de
supporter le poids de l’appareil et de son contenu.
AVIS
L’appareil est conçu pour être utilisé dans des
environnements où la température ambiante se situe entre
18°C (65°F) et 30°C (86°F).
En cas d’expédition en hiver, stocker l’appareil dans un
environnement à température ambiante adéquate pendant
10 heures afin d’éviter d’endommager le compresseur et/
ou le circuit frigorifique. Si l’appareil est allumé et que
vous constatez une vibration et des bruits excessifs,
éteignez-le immédiatement et laissez-le chauffer un peu
plus longtemps.
Prévoyez des ouvertures à grille ou à persiennes de
31 x 31 cm soit 961 cm² (12″ x 12″/144 square inches)
dans le meuble devant et derrière le groupe compresseur-
condenseur pour une bonne ventilation. Une mauvaise
circulation de l’air dans le groupe compresseur-
condenseur pourrait entraîner une panne de l’appareil et
aurait pour effet d’annuler la garantie.
Lorsque plusieurs cuves réfrigérées sont installées
simultanément, évitez que l’air sortant ne recircule dans
le meuble. L’arrivée d’air doit être située à l’extérieur du
meuble.
Lisez les consignes de sécurité importantes suivantes avant d’utiliser cet équipement pour éviter
toute blessure grave ou la mort et pour éviter d’endommager l’équipement ou la propriété.
Formulaire n° FTBM-0220
17
Français
CONSIGNES DE SÉCURITÉ IMPORTANTES
DESCRIPTION DU MODÈLE
Tous les Modèles
Les plans réfrigérés de libre service Hatco sont fiables et
polyvalents. Chaque appareil possède une structure isolée en
acier aluminisé et en acier inoxydable. La partie inférieure de la
cuve encastrée du plan réfrigéré est recouverte d’un serpentin
d’évaporateur en cuivre pour assurer un refroidissement
        
dans la cuve encastrée est le même pour tous les appareils
exceptés les FTB-3/4 et FTB-1. Les plans réfrigérés de libre
service sont contrôlés par un régulateur de température
numérique et un un interrupteur I/0 (marche / arrêt), qui se
trouvent sur le même panneau de contrôle à distance. Le
panneau de contrôle est connecté au groupe compresseur-
condenseur par un assemblage de conduits flexibles de
         

d’alimenter tout l’appareil. Tous les modèles sont conçus pour
être installés sur le dessus des différents types de revêtements
de comptoir y compris l’acier inoxydable, le bois, le revêtement
massif, le granit synthétique, etc. Les plans réfrigérés de libre
service Hatco sont conçus, fabriqués, et testés pour maintenir
les aliments à des températures correctes.
Le logo Ecoization désigne les produits conçus pour
refléter l’engagement d’Hatco à améliorer, protéger et
préserver l’environnement. Les plans réfrigérés de libre
service Hatco remplissent les conditions pour l’obtention
de ce logo, notamment grâce à leur isolation respectueuse
de l’environnement ainsi qu’à leur groupe compresseur-
condenseur économique.
Modèles FTB-X
Les modèles FTB-X sont disponibles dans des configurations
pour 3/4, un, deux ou trois plateaux. Sur ces modèles, en position
standard, les plateaux sont placés en largeur et face aux clients.
Modèles FTB-SX
Les modèles FTB-X sont disponibles dans les configurations
pour deux ou trois plateaux. Ces modèles ont une conception
« allongée », les plateaux sont placés en longueur et face aux
clients. Cette conception allongée permet un accès facile à tout
ce qui se trouve sur les plateaux.
NOTA: Les plateaux pour plans réfrigérés de libre service
sont à vendre. Consultez la section OPTIONS ET
ACCESSOIRES de ce manuel pour plus de détails.
Modèle FTB-S2
Modèle FTB-2
Bacs non inclus.
Plans réfrigérés de libre service (modèles FTB-2 et FTB-S2 illustrés)
AVIS
Maintenez l’appareil dans la position verticale lors du
transport et de l’installation. Le non-respect de cette
mesure pourrait endommager le système de réfrigération.
Lors de l’installation, manipulez l’appareil avec
précaution et évitez au maximum de heurter les tuyaux
et les conduites. La garantie ne couvre pas les éléments
endommagés pendant l’installation.
Ne pas utiliser l’appareil à un endroit exposé à des
températures excessives ou de la graisse de grils,
friteuses, etc. Les températures excessives risquent
d’abîmer l’appareil.
Nettoyez l’unité quotidiennement pour éviter les
dysfonctionnements et assurer un fonctionnement sain.
AVIS
Utilisez uniquement des nettoyants non abrasifs et des
chiffons doux. Les chiffons et nettoyant abrasifs pourraient
rayer la finition de l’unité, altérant son apparence et la
rendant vulnérable à l’accumulation de saleté.
N’utilisez pas de paille de fer pour le nettoyage. La paille
de fer raye les finitions.
L’utilisation de produits chimiques agressifs tels que l’eau
de javel, les produits nettoyants contenant de la javel, ou
les produits de nettoyage pour les fours sont proscrits
pour nettoyer l’appareil.
Cette unité est réservée à un usage professionnel
uniquement — elle n’est PAS dédiée à un usage personnel.
18
Formulaire n° FTBM-0220
Français
Modèle
Taille du
compresseur Tension Intensitè Amps
Conguration
de Fiches
Poids
d’embarquement
FTB-3/4 1/5 hp 120 300 3.8 NEMA 5-15P 54 kg (120 lbs.)
FTB-1
1/5 hp 120 300 3.8 NEMA 5-15P
60 kg (132 lbs.)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-2
1/5 hp 120 300 3.8 NEMA 5-15P
82 kg (180 lbs.)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-3
1/5 hp 120 300 3.8 NEMA 5-15P
97 kg (213 lbs.)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-S2
1/5 hp 120 300 3.8 NEMA 5-15P
83 kg (182 lbs.)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
FTB-S3
1/5 hp 120 300 3.8 NEMA 5-15P
109 kg (239 lbs.)
1/3 hp 220-230-240 108911901296 5.05.25.4 BS-1363, AS 3112, CEE 7/7
Côté haut Côté bas
12.8 bar
(186 psig)
6.07 bar
(88 psig)
DÉSIGNATION DU MODÈLE
CARACTÉRISTIQUES TECHNIQUES
F T B - S x
Plan réfrigéré
Libre service
Capacité de plateaux
Pas de caractères = Profondeur Standard
S = Allongée
Les zones grisées contiennent des informations
électriques pour les modèles internationaux uniquement.
NOTA: Le poids d’embarquement comprend l’emballage.
NOTA: Les étiquettes comportant les caractéristiques
techniques se situent sous l’appareil et derrière
le panneau de contrôle. Consultez l’étiquette
pour connaître le numéro de série et vérifier les
caractéristiques électriques de l’appareil.
Information sur le fluide frigorigène
Les plans réfrigérés de libre service Hatco utilisent le fluide
frigorigène R-513A pour les groupes compresseur-condenseur.
Configuration des fiches
Les appareils sont livrés avec un cordon électrique avec fiche.
Différentes fiches sont fournies selon les applications.
AVERTISSEMENT
DANGER DE
DÉCHARGE ÉLECTRIQUE : Brancher l’appareil sur une
prise de courant avec terre de tension, de format et de
configuration des broches corrects. Si la fiche et la prise
ne se correspondent pas, s’adresser à un électricien
qualifié pour déterminer et installer une prise de courant
de format et de tension corrects.
NEMA 5-15P
CEE 7/7 Schuko AS 3112
BS-1363
Configuration des fiches
NOTA: Prise non fournie par Hatco.
Tableau des valeurs nominales électriques
Conception pression
Formulaire n° FTBM-0220
19
Français
Modèle
Largeur
(A)
Profondeur
(B)
Hauteur
globale (C)
Hauteur de la
cuve (D)
FTB-3/4
535 mm
(21-1/16)
457 mm
(18)
437 mm
(17-1/4)
90 mm
(3-9/16)
FTB-1
535 mm
(21-1/16)
735 mm
(28-15/16)
437 mm
(17-1/4)
90 mm
(3-9/16)
FTB-2
991 mm
(39)
735 mm
(28-15/16)
437 mm
(17-1/4)
90 mm
(3-9/16)
FTB-3
1448 mm
(57)
735 mm
(28-15/16)
437 mm
(17-1/4)
90 mm
(3-9/16)
FTB-S2
1395 mm
(54-15/16)
535 mm
(21-1/16)
437 mm
(17-1/4)
90 mm
(3-9/16)
FTB-S3
2053 mm
(80-13/16)
535 mm
(21-1/16)
437 mm
(17-1/4)
90 mm
(3-9/16)
CARACTÉRISTIQUES TECHNIQUES
Dimensions
A B
C
D
Vue de face Vue de côté
Pression de
décharge
Pression
d’aspiration Surchaue
Sous-
refroidissement
115 to 125 psig
(7.9 to 8.6 bar)
0.4 to 0.6 bar
(6 to 9 psig)
2.2° to 5.6°C
(4° to 10°F)
2.8° to 5.6°C
(5° to 10°F)
Spécificités de fonctionnement
NOTA: Les spécifications de fonctionnement sont précises pour les
appareils dans une température d’air ambiant de 24 °C (75 °F).
20
Formulaire n° FTBM-0220
Français
INSTALLATION
Généralités
Les plans réfrigérés de libre service sont expédiés totalement
assemblés et prêts à l’usage à la sortie de l’usine. Utilisez les
informations et procédures suivantes pour préparer le lieu
d’installation et l’appareil ainsi que pour installer l’appareil.
AVERTISSEMENT
DANGER DE DÉCHARGE ÉLECTRIQUE :
Brancher l’appareil sur une prise de courant avec terre
de tension, de format et de configuration des broches
corrects. Si la fiche et la prise ne se correspondent pas,
s’adresser à un électricien qualifié pour déterminer et
installer une prise de courant de format et de tension
corrects.
L’unité n’est pas étanche. Il doit être installé en intérieur.
DANGER D’INCENDIE: Lors de l’installation, un espace
minimumde51mm(2″)doitêtremaintenuentrelesparoisdu
groupe compresseur-condenseur et toute surface combustible.
L’élément doit être installé par des installateurs formés
et qualifiés. L’installation doit être conforme à toutes
les normes électriques et de plomberie locales. Vérifiez
les procédures et les normes à suivre auprès de vos
inspecteurs locaux en plomberie et en électricité.
ATTENTION
Placer l’appareil sur un plan de travail de hauteur correcte
à un endroit qui convient pour son utilisation. Le support
doit être de niveau pour éviter toute chute accidentelle du
grille-pain ou de son contenu et suffisamment solide pour
résister au poids de l’appareil et de son contenu.
AVIS
En cas d’expédition en hiver, stocker l’appareil dans un
environnement à température ambiante adéquate pendant
10 heures afin d’éviter d’endommager le compresseur et/
ou le circuit frigorifique. Si l’appareil est allumé et que vous
constatez une vibration et des bruits excessifs, éteignez-le
immédiatement et laissez-le chauffer un peu plus longtemps.
L’appareil est conçu pour être utilisé dans des
environnements où la température ambiante se situe entre
18°C (65°F) et 30°C (86°F).
Prévoyez des ouvertures à grille ou à persiennes de
31 x 31 cm soit 961cm² (12″ x 12″/144 squareinches)
dans le meuble devant et derrière le groupe compresseur-
condenseur pour une bonne ventilation. Une mauvaise
circulation de l’air dans le groupe compresseur-
condenseur pourrait entraîner une panne de l’appareil et
aurait pour effet d’annuler la garantie.
Maintenez l’appareil dans la position verticale lors du
transport et de l’installation. Le non-respect de cette
mesure pourrait endommager le système de réfrigération.
Ne pas utiliser l’appareil à un endroit exposé à des
températures excessives ou de la graisse de grils, friteuses,
etc. Les températures excessives risquent d’abîmer l’appareil.
Tous les plans réfrigérés de libre service sont expédiés dans
une structure d’expédition pour assurer une bonne stabilité et
protection. Ne sortez l’appareil de son emballage que lorsque
le lieu d’installation et l’appareil sont prêts à être installés.
1. Retirez tout l’emballage externe de l’appareil.
2. Retirer le ruban et le film de protection de toutes les
surfaces de l’appareil.
NOTA: Pour éviter des retards dans l’obtention de la couverture
de la garantie, complétez l’enregistrement en ligne de votre
garantie. Lisez la section INFORMATIONS IMPORTANTES
POUR LE PROPRIETAIRE pour plus de détails.
Préparer l’appareil pour installation
L’orientation du groupe compresseur-condenseur sur tous les
modèles FTB peut être réglée pour correspondre au mieux à
l’agencement du lieu d’installation. Il peut être orienté à 90° ou
à 180° de sa position originale à la sortie de l’usine. Sur les
modèles FTB-3, FTB-S2, et FTB-S3, le groupe compresseur-
condenseur peut être installé dans différentes positions contre
la partie inférieure de la cuve du plan réfrigéré à l’aide des

compresseur-condenseur des modèles FTB-2 peut être installé

Inspectez le lieu d’installation et déterminez si l’orientation et/ou
la position du groupe compresseur-condenseur ont besoin d’être
réglées. Prenez en compte le besoin d’ouvertures à grille ou à
persiennes dans le meuble afin d’assurer une ventilation correcte
du groupe compresseur-condenseur. Une de ces ouvertures doit se
situer devant les serpentins du condenseur et l’autre à l’opposé. Si
l’orientation et/ou la position du groupe compresseur-condenseur
ont besoin d’être réglées, suivez la/les procédure(s) suivante(s).
Faire pivoter le groupe compresseur-condenseur
Cette procédure peut être suivie pour tous les modèles FTB.
1. Placez des cales sous le groupe compresseur-condenseur
pendant la rotation.
2. Retirez les 4 vis de montage qui soutiennent le cadre de
soutien du groupe sous la cuve du plan.
3. Tournez le groupe compresseur-condenseur à 90° ou à
180°, en fonction du lieu d’installation.
NOTA: Quand vous effectuez la rotation du groupe, veillez à
ne pas placer les tuyaux de l’évaporateur ou tout autre
obstacle devant le serpentin du condenseur.
4. Vissez de nouveau le cadre de soutien du groupe en
dessous de la cuve du plan à l’aide des 4 vis de montage.
Les tuyaux ont
été retirés pour
une meilleure
visibilité.
Vis de montage
Groupe
compresseur-
condenseur
orienté à 90°
Cadre de soutien
du groupe
compresseur-
condenseur
Rotation du groupe compresseur-condenseur
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Hatco FTB, FTB-S Series Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues