tank s approprate to the refrgerant njecton quantty n the
entre system. All tanks ntended to be used for the recovery
of refrgerants should have a refrgerant dentfcaton (.e.
refrgerant recovery tank). Storage tanks should be equpped wth
pressure relef valves and globe valves and they should be n a
good condton. If possble, empty tanks should be evacuated and
mantaned at room temperature before use.
3. The recovery equpment should be kept n a good workng
condton and equpped wth equpment operatng nstructons for
easy access. The equpment should be sutable for the recovery of
R290 refrgerants. Besdes, there should be a qualfed weghtng
apparatus whch can be normally used. The hose should be lnked
wth detachable connecton jont of zero leakage rate and be kept
n a good condton.
Before usng the recovery equpment, check f t s n a good
condton and f t gets perfect mantenance. Check f all electrcal
components are sealed to prevent the leakage of the refrgerant
and the fre caused by t. If you have any queston, please consult
the manufacturer.
4. The recovered refrgerant shall be loaded n the approprate
storage tanks, attached wth a transportng nstructon, and
returned to the refrgerant manufacturer. Don’t mx refrgerant n
recovery equpment, especally a storage tank.
5. The space loadng R290 refrgeraton can’t be enclosed n the
process of transportaton. Take ant electrostatc measures f
necessary n transportaton. In the process of transport, loadng