Salter Brecknell 405 Manuel utilisateur

Catégorie
Balances personnelles
Taper
Manuel utilisateur
Model 405 Weighing Scale
User Manual
AWT35-000053 Issue A
©Avery Berkel Limited 2006. All rights reserved.
The information contained herein is the property of Avery Berkel Limited and is supplied without liability for errors or
omissions. No part may be reproduced or used except as authorised by contract or other written permission. The
copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be
embodied.
Salter Brecknell is a trading name of Avery Berkel Limited
Model 405
User Manual
Contents
WARNINGS............................................................................................................................... 6
Setting Up the Scale.................................................................................................................. 7
Display and Keypad .............................................................................................................. 7
Manual Symbols.................................................................................................................... 8
Scale Operation......................................................................................................................... 8
Turning On and Zeroing the Scale........................................................................................ 8
Turning Off the Scale ............................................................................................................ 8
Selecting Unit of Measure..................................................................................................... 8
Using the Tare....................................................................................................................... 9
Removing the Tare................................................................................................................ 9
Setting up the Auto-Off Function......................................................................................... 10
Calibration........................................................................................................................... 10
Error Messages................................................................................................................... 11
Declarations of Compliance..................................................................................................... 13
United States....................................................................................................................... 13
Canada................................................................................................................................ 13
5
Model 405
User Manual
WARNINGS
Safe installation
Safety
THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS.
Installation and maintenance of the equipment must only be carried out by trained
and authorised personnel.
Electrical installation
The mains lead must be connected to a supply outlet with a protective earth contact.
The electrical supply at the socket outlet must provide over current protection of an
appropriate rating.
For your protection all mains (110V or 230V) equipment used out of doors or in wet or
damp conditions should be supplied from a correctly fused source and protected by
an approved ground fault protection device (RCD, GFCI etc.)
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.
Routine maintenance
To avoid the possibility of electric shock or damage to the machine, always switch off
the machine and isolate from the power supply before carrying out any routine
maintenance.
To avoid the risk of the machine falling, where applicable, ensure that it is placed
securely on a flat and level surface.
Safe use
Caution – Cleaning the indicator/weigh head
Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions, such as
washing soda, should not be used especially on the display windows. Under no
circumstances should you attempt to wipe the inside of the machine.
The outside of standard products may be wiped down with a clean cloth, moistened
with water containing a small amount of washing up liquid.
The outside of products waterproofed to IP65, IP66 and IP67 may be washed down
with water containing a small amount of proprietary detergent.
Training
Do not attempt to carry out any procedure on a machine unless you have received
the appropriate training or read the Instruction Manual.
EMC compliance
The following may be applicable to your machine.
WARNING:
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
6
Model 405
User Manual
Setting Up the Scale
To set the scale up for operation, please refer to the following illustration while performing the
steps below.
X
1. To level the scale, adjust the feet on the underside of the scale.
2. The Salter 405 is powered by a rechargeable battery or 12V power adapter supplied
with the scale. To charge the battery or operate the scale from the adapter, insert the
adapter into the socket on the underside of the scale.
Display and Keypad
405
Tare/Units
On/Off/Zero
kg/lb
Max = 6kg / 12lb d = 0.001kg / 0.002lb
kg
g
lb
I
0
T
CHG
AC
ZERO
0
oz
NET
Function Keys Annunciators
ZER
O
0
Illuminated when weight is zero
Tare/Units of measurement
NET
Illuminated when tare has been
activated
kg
lb
Depends on active unit of measure
(Flashing LED means that the weight
reading is not stable.)
A
C
Illuminated when adaptor is plugged
in
On/Off/Zero
CHG
Illuminated when battery is charging
Tare/Units
kg/lb
T
On/Off/Zero
7
Model 405
User Manual
Manual Symbols
Short key press
Multiple key press
Long key press
Scale Operation
Turning On and Zeroing the Scale
ZERO
0
Turning Off the Scale
Selecting Unit of Measure
kg
g
lb
CHG
AC
ZERO
0
oz
NET
k
g
g
oz lb
kg/lb
T
8
Model 405
User Manual
Using the Tare
1.
ZERO
0
NE T
2.
ZERO
0
NE T
3.
ZERO
0
NE T
4.
ZERO
0
NET
kg/lb
T
Removing the Tare
ZERO
0
kg/lb
T
9
Model 405
User Manual
Setting up the Auto-Off Function
Before beginning, the scale must be switched on.
1.
kg/lb
T
+
kg
g
lb
CHG
AC
ZERO
0
oz
NE T
2.
kg/lb
T
0-9 minutes (0 switches function off)
3.
kg
g
lb
CHG
AC
ZERO
0
oz
NE T
Calibration
To calibrate, switch off the scale.
1.
kg/lb
T
+
kg
g
lb
CHG
AC
ZERO
0
oz
NE T
2.
kg/lb
T
3.
kg
g
lb
CHG
AC
ZERO
0
oz
NET
4.
6kg/15kg
Or
12lb/30lb
kg
g
lb
CHG
AC
ZERO
0
oz
NET
5.
6kg/15kg
Or
12lb/30lb
kg
g
lb
CHG
AC
ZERO
0
oz
NE T
Î
Î
Î
k
g
lb
Î
Î
10
Model 405
User Manual
Error Messages
Error Message Definition Required Solution
0¯ ¯ ¯ ¯:
Weight above range for calibrated
zero point
Remove load before zeroing,
-or-
Recalibrate the scale.
0_____:
Weight below range for calibrated
zero point
Remove load before zeroing,
-or-
Recalibrate the scale.
_____:
Indicates an under range condition
Remove all loads, and zero the
scale.
¯ ¯ ¯ ¯:
Capacity exceeded
Remove the load, and try again.
If the load is greater than 6 kg, a
scale with a larger capacity is
required.
CAL-Er:
Calibration error Restart calibration.
Lo.bAt:
Low Battery Recharge the battery.
11
Model 405
User Manual
12
Model 405
User Manual
Declarations of Compliance
United States
This equipment has been tested and found to comply with the limits for a class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Canada
This digital apparatus does not exceed the Class A limits for the radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Classe A prescrites dans le Règlement sur le
brouillage radioélectrique edicté par le ministère des Communications du Canada.
Manufacturer Salter Brecknell
Type 405
Corresponds to the requirements of the following EC directives:-
Electro Magnetic Compatibility Directive:
Low Voltage Directive:
EMC 89/336/EEC
LVD 73/23/EEC
The application harmonised standards are:
EN60950
EN50081-1
EN50082-1
Declaration of Conformity
A copy of the original signed declaration for this instrument is available from the UK address
below.
UK and Europe
Salter Brecknell Weighing
P.O. Box 9533, Smethwick,
West Midlands, B66 2TE.
United Kingdom.
Tel: +44 (0) 870 444 6132
Fax: +44 (0) 870 010 2241
email:sales@salterbrecknell.co.uk
www.salterbrecknell.co.uk
USA
Salter Brecknell Weighing Products USA
1000 Armstrong Drive
Fairmont
MN 56031
Toll Free: 800-637-0529
Phone: 507-238-8702
Fax: 507-238-8271
email:sales@salterbrecknell.com
www.salterbrecknell.com
13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Salter Brecknell 405 Manuel utilisateur

Catégorie
Balances personnelles
Taper
Manuel utilisateur

dans d''autres langues