Extron electronics TLP Pro 720C Manuel utilisateur

Taper
Manuel utilisateur
1
IMPORTANT:
Go to www.extron.com for the
complete user guide and installation
instructions before connecting the
product to the power source.
TLP Pro 720C • Setup Guide
Overview
The Extron TLP Pro 720C is a 7 inch Cable Cubby touchpanel with a ip-up, 800x480 LCD touchscreen with 18-bit color depth.
It is ideal for any AV application requiring a full-size, Cable Cubby touchpanel with a customizable interface. This guide provides
instructions for experienced installers to mount and install a TLPPro 720C touchpanel. For more complete instructions, see the
TLPPro 720C User Guide, at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software (available from www.extron.com):
GUI Designer — For designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces.
Global Configurator
®
Professional or Global Configurator Plus — For setting up and conguring the control
processor and touchpanel.
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings,
system utilities, and user management for TouchLink Pro devices.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you will also require
IP address Subnet mask Gateway
Username — This can be either admin or user.
Passwords — The factory congured passwords for all accounts on this device have been set to the device serial
number. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password will be the default password conguration. The default
password is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Make sure you are familiar with all the included parts and have all the Tools Required for Installation (see page 2).
Included Parts
TLP Pro 720C
Table Clamps
AC Power Module*
Blank AAPs
Pass-thru AAPs
Extron
Extron
Extron
Extr
on
Extron
Removal Tool
Zip Ties
#4−40 Screws
and Nuts
2 Pos
AAP Shelf Bracket Kits
(2 brackets/kit)
3 Pos1 Pos
NOTES:
*
Inside the US, the TLP Pro 720C can be purchased with or without an AC
power module. Outside the US, see www.extron.com to nd an AC power
module for your country.
Active or Passive AAPs must be purchased separately (see www.extron.
com).
Figure 1. Included Parts
With Power
Module
Without Power
Module
AC Power Module* 1 0
Pass-through AAPs
3 3
Blank AAPs 6 6
1-position bracket kit 0 1
2-position bracket kit 3 4
3-position bracket kit 1 1
2
TLP Pro 720C • Setup Guide (Continued)
Tools Required for Installation
Safety Glasses
Phillips Screw Driver
Tape Measure
1/4" Hex Nut Driver
Marking Pen
Square
Vacuum Cleaner
Figure 2. Tools Required for Installation
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels until you have read the Attention in the Power Supply section of the TLP Pro 720C
User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section «sources d’alimentation» du
TLP Pro 720C UserGuide.
Mount the units (see Mounting below).
Install power modules in the cable cubby.
Install AAPs and run cables to the cable cubby.
Connect cables to the touchpanels.
Connect the power cords and power on all devices.
Set up the Touchpanels for Network Communication
Connect the PC that you will use for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 8) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a
project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.
Mounting
Planning
Before making any cuts, select the best location for the TLPPro 720C.
Ensure that the edge that opens on the lid is oriented correctly.
Ensure there is enough space for all the system cables and components, including cable retractors, if they are to be installed.
The space requirements for retractors are shown in the TLP Pro 720C User Guide, which is available at www.extron.com.
Decide on the method for cutting a hole in the table:
Hand router and metal router guide
CNC wood router
Jigsaw and paper template
Verify that you have the correct template or dimensions.
Check all relevant regulations.
Ensure that the installation complies with local, state, and national building and electrical codes.
Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.
3
Product Category
Step 1 — Obtain Cut-out Dimensions
ATTENTION:
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care
to prevent scarring or damaging the furniture.
L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et qualiés.
Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in
the furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is
underlined (see Using a CNC wood cutter below). Extron is not responsible for miscut mounting holes.
Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface
indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la directions dans
laquelle l’unité sera dirigée. Le côté pour accéder au connecteurs est souligné (voir Using a CNC wood cutter
ci-dessous). Extron ne sera pas responsable des erreurs de coupe.
Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.
Assurez vous que la position du CableCubby et les dimensions du trou soient correctes avant de couper la table.
Ensure the table surface is at least 0.375 inch (0.95 cm) thick.
Assurez vous que la surface de la table est au moins 0,95 cm (0,375 pouce) d’épaisseur.
If using a hand router, you should purchase the Extron TLP Pro 720C routing template (see “Installation Routing Templates for
Cable Cubby Series/2 Enclosures” at www.extron.com).
If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood cutter below).
If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 720C
page at www.extron.com).
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment.
ATTENTION : Risque de blessure: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying
and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table”
in the TLP Pro 720C User Guide). There are three methods for cutting the hole in the table:
Using a hand router
Recommended method — Use the Extron TLP Pro 720C routing
template. Refer to the Routing Template User Guide, available at
www.extron.com, to prepare the template and use the template to
cut the hole.
NOTE: The metal router guide must be purchased separately. It is
reusable and should not be discarded when the installation is
complete.
Using a CNC wood cutter
Recommended method — Use the exact cut-out dimensions:
8.90 +0.00/-0.02 inches W x 7.10 +0.00/-0.02 inches D
(22.61 +0.00/-0.05 cm W x 18.03 +0.00/-0.05 cm D)
NOTE: The underlined dimension is the connector or AAP access
side for the unit.
Using a reciprocating saw or jigsaw
Acceptable method — Use the paper cut-out template
(available under the Downloads tab on the TLPPro 720C page at
www.extron.com).
HSA 200
USER ACCESS
HSA 200
CABLE CUBBY 300
CABLE CUBBY 300
USER ACCESS
Figure 3. Using a Hand Router
Cut-Out Template for the Extron
TLP Pro 720C
Outer Edge of Trim Ring
(Do not cut this line.)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Mark the position on the wall or
furniture where the TLP 710MV
is being installed.
4. Cut the opening.
P/N 68-2046-01 Rev. B
Page size: 11" x 17"
Print scale 1:1
Do not shrink.
P/N
P/
Figure 4. Using a Reciprocating Saw or Jigsaw
Step 2
4
TLP Pro 720C • Setup Guide (Continued)
Step 3 — Run all Cables
Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the
cables below the table and through the hole that was cut in Step 2. Leave enough slack in the cables to connect or route them
before the cubby is installed in the table. Leave enough space under the TLPPro 720C enclosure for the external power supply
and connection of AV cables and the network connection.
Step 4 — Install Cable Retractors (Optional)
If required, Extron cable retractors must be purchased separately. It is difcult to mount the Cable Cubby into the table after the
retractors have already been installed, so Extron recommends installing the empty retractor bracket at this point. The bracket
should be secured using the lowest level of mounting holes inside the touchpanel enclosure.
The retractors should be added to the bracket after Step 8 — Mounting the Enclosure on page 6. For complete information
about retractors and how to install them, see the TLP Pro 720C User Guide and Retractors User Guide at www.extron.com.
Step 5 — Install Power Module (Optional)
ATTENTION:
For units that are used in North America, only
use AC power modules that are UL Listed Model
“Cable Cubby AC Power Module”.
Pour les unités qui sont utilisées en Amérique
du Nord, utilisez seulement les modules
d’alimentation secteur qui sont listés UL, modèle
« Cable Cubby AC Power Module ».
The unit is not UL Listed if it uses any AC power
module other than Model “Cable Cubby AC Power
Module”.
L’unité n’est pas listée UL si elle utilise tout autre
module d’alimentation secteur autre que le modèle
« Cable Cubby AC Power Module ».
Secur
e the power module
t
o the TLP Pro 720C frame
with #4-40 Phillips head
sc
rews and star washers.
Extron
Figure 5. Securing the Power Module
NOTE: For models that do not include a power module, see the Extron website to select a power module that is suitable for
your location.
The power module takes up two or three AAP spaces, depending on the model, and may be installed before or after the AAP
assembly is installed. It may be installed with AAPs on either side.
1. Secure the power module into position with #4-40 Phillips head screws and star washers.
CAUTION: Risk of electric shock: To ensure proper electrical grounding, use the provided grounding screws and star
washers.
ATTENTION : Risque de choc électrique: An d’assurer une mise à la terre correcte, utilisez les xations de mise à la
terre et les rondelles en étoile fournies.
2. Run the cable or conduit to a convenient junction box. Extron recommends the circuit be attached to a junction box that is
directly wired to the main circuit.
5
Product Category
Step 6 — AAP Assembly
Install all desired cables into the cable pass-through AAPs and
install the AAPs into the cable cubby.
The simplest way to install the cables and AAPs is to populate
the AAP brackets outside the cubby and then install the
populated AAP shelf assembly into the cubby.
Install cables in the pass-through holes as shown in the gure to
the right.
TIP: Hand tightening the #4-40 nuts makes it easier to
place and secure the assembly inside the enclosure.
NOTE: An extra column of AAP bracket mounting points is
available for use with TLP Single-space AAP mounting
brackets. Single-space brackets will not t in any other
location.
Rear Bracke
ts
Front Brackets
The extra column
of mounting points
is for installing
single-space
AAP brackets.
Figure 6. AAP Assembly
Step 7 — Install the AAP Assembly
1. From under the table, push the rst AAP assembly
through the bottom of the enclosure. The holes in the rear
bracket must align with the bottom row of holes on the
rear face of the enclosure.
TIP: Ensure there is enough space above the AAP
assembly for the lid to close completely without
cables or connectors contacting the touchpanel.
2. Secure the AAP assembly into position with the provided
Phillips head screws.
3. Tighten the nuts that secure the AAPs to the brackets.
COMP
UTER
AUDIO
Phillips Head Scr
ews
(secur
e AAP
assemb
ly)
Tighten down
AAP nuts.
Push assembly thr
ough
bottom of enclosure.
Large slot
provides tool
access to fasten
rear brackets.
1
1
1
2
2
2
3
3
3
Extron
Figure 7. Installing the AAP Assembly
6
TLP Pro 720C • Setup Guide (Continued)
Step 8 — Mounting the Enclosure
CAUTION: The anged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily
nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION : Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses
et peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier an d’éviter de
l’endommager ou de vous blesser.
1. Remove the edge grommet protecting the edges of the trim ring
and the plastic lm on the nished surfaces.
ATTENTION:
Do not use isopropyl alcohol or other solvents to
clean the Cable Cubby. Strong solvents will ruin some
nishes.
Ne pas utiliser de l’alcool isoproprylique ou d’autres
solvants pour nettoyer le CableCubby. Les solvants
forts endommageront certaines nitions.
2. Carefully lower the enclosure into the hole cut in the table
(see Step 2 — Cut the Surface on page 3). Ensure the
trimring(
5
) is ush with the top of the table.
3. Under the table, attach the table clamps (
3
) to the pins on each
side of the enclosure. It may be necessary to loosen the wingnuts
(
1
) and the Phillips head screws (
2
).
1
1
5
5
2
2
3
3
4
4
Figure 8. Mount the Enclosure
4. When the clamps are properly seated on the pins, tighten the Phillips head screws until the clamp faces (
4
) are tightly
secured against the bottom of the table. To prevent the screws from becoming loose, secure the wingnuts against the table
clamp bodies.
Connecting the TLP Pro 720C
The cable connections are located in a panel on the bottom of the TLP Pro 720C:
A
A
A
B
B
B
Figure 9. TLP Pro 720C Cable Connectors
A
Power connector — Connect a 12 VDC, 1.0 A power supply (not provided) to this 2-pole, 3.5 mm captive screw connector.
ATTENTION:
The TLP Pro 720C can use a 12 VDC desktop power supply and is also Power over Ethernet (PoE 802.3af,
class3) compliant. Do not connect either power supply before reading the Attention in the Power Supply sections
of the TLPPro720C User Guide.
Le TLP Pro 720C peut utiliser une source d’alimentation externe 12 Vcc, et est également compatible avec
l’alimentation POE via Ethernet (PoE 802.3af, classe 3). Ne branchez pas de sources d’alimentation externes
avant d’avoir lu les mises en garde dans la section «PowerSupply» du TLPPro720C User Guide.
NOTES:
The TLP Pro 720C ships without a power supply. Either the 12 VDC power supply or the power injector must be
purchased separately.
If a 12 VDC power supply and a power injector are both connected to the TLP Pro 720C, the power injector takes
precedence. If a PoE power loss is detected, the touchpanel switches seamlessly to the 12 VDC power supply
without needing a system reboot.
B
Network and Power over Ethernet (PoE) Connector — Connect the touchpanel to the LAN using a twisted pair cable,
terminated with an RJ-45 connector. The connector can also be used with a PoE power injector (not provided).
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
7
Product Category
Front Panel Features
To see all the front panel features, remove the bezel, using the Extron Removal Tool (see Included Parts on page 1). For a
complete description of all these features and their function, see the TLP Pro 720C User Guide.
ATTENTION:
When you slide the removal tool between the screen and the bezel, take care to avoid damaging the ribbon
cable, which runs close to the edge of the bezel.
Lorsque vous faites glisser l’outil d’extraction entre l’écran et le châssis, faites attention à éviter d’endommager
la nappe de raccordement se trouvant à proximité du bord du châssis.
A
A
A
D
D
D
E
E
E
C
C
C
B
B
B
F
F
F
G
G
G
A
Ambient light sensor — This sensor monitors ambient light level and adjusts screen brightness, based on the settings
congured using the Setup Menu (see page 8).
B
Bezel attachment point — The TLP Pro 720C has eight attachment points (two on each side, two on the top edge, and two
on the bottom edge).
C
LCD screen — The TLP Pro 720C has a 7 inch screen with a 800x480 resolution.
D
Reset LED— This LED indicates power status and reset status of the device.
E
Communication LED — This LED shows the conguration and connection status of the touchpanel:
z Unlit during normal operation (the touchpanel is congured and connected to an IP Link Pro control processor).
z Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
z Permanently lit if the touchpanel has not been congured and is not connected to an IP Link Pro control processor.
The indicator can be toggled between enabled and disabled, using the Setup Menu (see page 8).
F
Reset button — This button allows the unit to be reset. The TLP Pro 720C has three reset modes that are initiated by
pressing the reset button (see Reset Modes: a Brief Summary on page 8). For full information about these different
modes, see the TLPPro 720C User Guide.
G
Menu button — This button activates the Setup Menu and Calibration Screen (see page 8).
H
Bezel — To detach the bezel, use the included removal tool (see the gure to the right, above).
I
Speaker — A single speaker, located inside the cable cubby, provides audible feedback for the user.
J
Bezel removal slots — The slots allow for the removal of the bezel, using an Extron removal tool.
K
Illumination LED — This LED provides light for cable cubby enclosure.
H
H
H
J
J
J
K
K
K
I
I
I
8
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
For information about replacing and disposing of batteries, see the TLP Pro 720C User Guide at www.extron.com.
© 2014 - 2021 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
68-2406-50 D
01 21
TLP Pro 720C • Setup Guide (Continued)
Reset Modes: a Brief Summary
The TLP Pro 720C offers the following reset modes (see the TLP Pro 720C User Guide for complete information):
Use factory firmware:
Press and hold the Reset button (see Front Panel Features,
F
, on page 7) while
applying power to the unit. Use this mode to replace rmware in the event of rmware
failure.
Reset All IP Settings:
Press and hold the Reset button for 6 seconds. After the Reset LED (
D
) ashes twice,
release and momentarily press the Reset button. Use this mode to reset all network
settings without affecting user-loaded les.
Reset to Factory Defaults:
Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times,
release and momentarily press the Reset button. Use this mode to return the interface to
factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set
to the device serial number. Passwords can be changed during conguration.
Passwords are case sensitive.
If the device is reset to default settings, the passwords are reset to the default
password, which is extron (for either admin or user).
Enable or Disable the DHCP
Client
Use this mode to toggle between DHCP enabled and DHCP disabled. Press the Reset
button ve times consecutively. After the fth press, do not press the button again within 3
seconds. If DHCP was enabled, it is now disabled and the Reset LED blinks three times. If
DHCP was disabled, it is now enabled and the Reset LED blinks six times.
Setup Menu
The setup menu opens when the menu button is pressed (
G
). There are
ve different screens: Status, (shown in the gure to the right) Network,
Display, Audio, and Advanced. The screens can be selected by pressing
the appropriate button in the navigation bar at the top of the screen (for
more information, see the TLPPro 720C User Guide).
Press the menu button for at least 2 seconds to open the calibration
screen. Follow the on-screen instructions.
Status
Display Audio Advanced Exit
Network
Info
Model: TLP Pro 720C
Part Number: 60-1396-020A
Firmware
Version:
1.00
PoE Status:On
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLP-AB-CD-EF
Display
Resolution:
Project:
Sleep Timer:
800x480
N/A
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Advanced
Controller IP: N/A
Project Size: N/A
Calibration Screen
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Extron electronics TLP Pro 720C Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues