OWNER'S MANUAL
SOLID FUEL
WARM AIR FURNACE
COAL ONLY
FOR PARALLEL INSTALLATION WITH EXISTING FORCED AIR-GAS OR OIL FIRED FURNACE
(U.S. ONLY)
FOR INSTALLATION AS A CENTRAL FURNACE
THE 1500 HOTBLAST FURNACE HAS BEEN APPROVED FOR
U.S. INSTALLATIONS ONLY.
ALL MODELS CERTIFIED UNDER UL 391
THE 1300 MODEL IS ALSO CERTIFIED UNDER CAN/CSA-B366.1-M91
851486N-1901G
CAUTION:
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING
THE FURNACE
IMPROPER INSTALLATION MAY
VOID YOUR WARRANTY
DO NOT USE THIS FURNACE
IN A MOBILE HOME OR TRAILER
U.S. Environmental Protection Agency
This heater is not certied for wood burning. Use of any
wood fuel is a violation of federal regulations.
-2-
NOTE: YOUR UNIT MUST BE INSTALLED BY A
QUALIFIED FURNACE INSTALLER.
You've purchased one of America's Finest Coal Burning Furnaces. By heating with coal
you're helping CONSERVE AMERICA'S ENERGY!
CONGRATULATIONS!
TOOLS
Pencil
6 Foot Folding Rule or Tape
Tin Snips
Drill, Hand or Electric
Drill Bit- 1/8" Dia.
(For Sheet Metal Screws)
Screw Driver (Blade-Type)
Gloves
Sabre Saw
5/16" Nut Driver or
5/16" Socket W/Ratchet
Safety Glasses
MATERIAL
6" Pipe, 6" Elbow, Collar and Thimble;
as required (24 gauge min.)
1/2" Sheet Metal Screws
6" Inside diameter Listed Residential
Type or Building Heating Appliance
Chimney or existing masonry chimney
Electrical Wiring
6" Draft Regulator
1/2" Conduit (Conduit Connectors)
Furnace Cement (Manufacturer
Recommends: Rutland Black-Code 78
or Equivalent)
Plenum and Duct work as required.
TOOLS AND MATERIALS NEEDED
Note: Register your product on line at www.usstove.com. See “Limited Warranty” section for specic
warranty information for your new purchase. Save your receipt with your records for any claims.
-3-
Caution Labels
Your Furnace has the following labels. Read and Obey all labels.
DANGER: RISK OF FIRE OR EXPLOSION.
DO NOT burn garbage, gasoline, drain oil, or other ammable liquids.
WARNING: FIRE HAZARD.
DO NOT operate with re draft exceeding .06 inches w.c.
DO NOT operate with fuel loading or ash removal doors open.
DO NOT store fuels, paints, thinners, ammable liquids, or other highly volatile substances
in the furnace room.
CAUTION:
HOT SURFACES! Keep children away. Do not touch during operation.
SAFETY NOTICE:
If this heater is not properly installed, a house re may result. For your
safety, follow the installation directions. Contact local building or re of-
cials about restrictions and installation inspection requirements in your
area. If not already installed, we recommend that smoke detectors be
installed.
CAUTION!
CLEANOUT OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY, AND
DRAFT INDUCER (IF USED), IS ESPECIALLY IMPORTANT AT THE END
OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE
SUMMER MONTHS, CAUSED BY ACCUMULATED ASH.
CAUTION!
INSPECT FLUE PIPES, FLUE PIPE JOINTS AND FLUE PIPE SEALS
REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT
DRAWN INTO, AND CIRCULATED BY, THE AIR CIRCULATION SYSTEM.
-4-
Rules for safe installation and operation
Read these rules and the instructions carefully. Failure to follow them will cause a hazard
that could result in death, serious bodily injury, and/or property damage.
Your Furnace is designed to be installed in a parallel air ow arrangement with a gas or oil-red
forced air upow-type central furnace, or it may be installed as a central furnace.
1. Check your local codes. The installation must comply
with their rulings.
2. Do not install this furnace in a mobile home or trailer.
3. Always connect this furnace to a chimney and vent to the
outside. Never vent to another room or inside a building.
4. Do not connect this furnace to an aluminum Type B gas
vent. This is not safe and is prohibited by the National
Fire Protection Association Code. This furnace requires
a masonry or Listed Factory Built Chimney for residential
type or Building Heating Appliance Chimney. Use a 6"
diameter chimney or larger, that is high enough to give
a good draft.
5. Be sure that if a masonry chimney is used, it is safely
constructed and in good repair. Have the chimney in-
spected by the Fire Department or an inspector.
6. Inspect chimney connector and chimney before and
frequently during the heating season for any deposit of
creosote or soot which must be removed.
7. Provide air for combustion into the room where the furnace
is located. If the intake is not in the same room, air must
have free access to the room.
8. CAST IRON PARTS MUST BE "SEASONED" TO AVOID
CRACKING, BUILD ONLY SMALL FIRES ON FIRST
USE.
9. To prevent injury, do not allow anyone to use this furnace
who is unfamiliar with the correct operation of the furnace.
10. For further information on using your furnace safely, obtain
a copy of the National Fire Protection Association (NFPA)
publication "Chimney's, Fireplaces and Solid Fuel Burn-
ing Appliances" NFPA 211. The address of the NFPA is
Batterymarch Park, Quincy, MA 02269.
11. Keep the ashpit section free of excess ashes. Do not al-
low ashes to stack higher than the sides of the ash pan.
12. DISPOSAL OF ASHES- Place ashes in a metal container
with a tight tting lid. Keep the closed container on a
noncombustible oor or on the ground, well away from
all combustible materials. Keep the ashes in the closed
container until all cinders have thoroughly cooled. The
ashes may be buried in the ground or picked up by a
refuse collector.
13. CAUTION- The special paints used on your furnace
may give off some smoke while they are curing during
rst few res., Build small res at rst. The metal used
in construction of the furnace and duct work has a light
coating of oil. This could give off smoke and/or odor from
registers when furnace is used for the rst time. This
should disappear after a short period of time. Once this
burn-off has occurred, it should not reoccur.
14. CARING FOR PAINTED PARTS- This furnace has a
painted outside jacket, which is durable, but it will not
stand rough handling or abuse. When installing your
furnace, use care in handling. Clean with soap and
warm water when furnace in not hot. DO NOT use any
acids or scouring soap, as these wear and dull the nish.
DISCOLORATION WILL OCCUR IF THE FURNACE IS
OVERHEATED. FOLLOW OPERATING INSTRUCTIONS
CAREFULLY.
15. Keep the feed and ash doors closed at all times except
while tending the furnace.
CAUTION
DO NOT OPERATE WITH THE FEED AND/OR ASH
DOOR OPEN. THIS FURNACE IS DESIGNED FOR
THERMOSTATIC OPERATION. OPERATION WITH
ANY OF THESE DOORS OPEN WILL OVERHEAT
AND DAMAGE THE FURNACE.
WARNING
NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY
GASOLINE, IN THE VICINITY OF THE FURNACE.
CAUTION
GASES THAT ARE DRIVEN FROM FRESH COAL
MUST BE BURNED OR THEY WILL ACCUMULATE
AND EXPLODE. NEVER SMOTHER A FIRE WHEN
ADDING FRESH COAL.
CAUTION
NEVER USE GASOLINE, GASOLINE-TYPE LAN-
TERN FUEL, KEROSENE, CHARCOAL LIGHTER
FLUID, OR FLAMMABLE LIQUIDS TO START OR
"FRESHEN UP" A FIRE IN THE FURNACE.
-5-
Your HOTBLAST Furnace is designed to be a supplemental or
central heating source for your home. This Solid Fuel Furnace
may be installed in conjunction with a properly operating
central furnace that is listed or certied in accordance with
nationally recognized safety standards and equipped with
the required controls and other safety features and which
has been installed in accordance with appropriate standards
of the National Fire Protection Association with installation
clearances specied in the furnace nameplate marking. The
installation must be accomplished by a qualied agency (one
who is engaged in, and is responsible for, or is thoroughly
familiar with the installation and operation of the gas, oil, and
solid fuel burning heating appliances, who is experienced in
such work, familiar with all the requirements of the authority
having jurisdiction.) The installation shall be in strict accordance
with the manufacturer's installation instructions furnished with
the solid fuel furnace.
The chimney connector of the furnace is to be installed to
provide clearances to combustible material not less than
specied in the individual classications and marked on the
furnace. The chimney connector must be connected to a
chimney suitable for use with residential type or building
heating appliances which burn solid fuel.
The Furnace is designed to operate in either parallel or series
air ow arrangement with the central furnace or as a central
furnace.
CENTRAL FURNACE INSTALLATION
As a central furnace, the unit functions independently of any
other system. The blower will come on when the plenum
temperature reaches the setting on the blower control.
PARALLEL INSTALLATION (U.S. ONLY)
The design is such that when the blower comes on, the blower
on the central system also comes on. The blower will only
come on when the temperature in the plenum has reached
the setting on the blower control. This is to insure that there
is sufcient warm air in the system to make it efcient for the
unit to operate. When the central system thermostat calls for
heat, the central system will operate by the burner igniting
and the blower coming on. It is possible that both systems
will operate simultaneously. It is recommended that for the
most efcient use of your HOTBLAST Furnace, that it be red
as much as possible in order to reduce the demand on your
existing central heating system. This unit has an optional
forced draft kit that operates from a wall thermostat. When
the temperature falls below the setting on the wall thermostat,
the forced draft will come on (U.S. Stove Option 11/DIKL)
The warm air supply outlet of the HOTBLAST Furnace shall
not be connected to the cold air return of the central furnace,
because the possibility exists of components of the central
furnace overheating and causing the central furnace to operate
other than is intended.
SERIES INSTALLATION
This type of installation uses only the blowers of the existing
central furnace. The solid fuel fan/limit control must also
control the functions of the existing furnace. All electrical
power must come from a single branch circuit.
HOW THE FURNACE FUNCTIONS
-6-
DIMENSIONS OF FURNACE
Figure 2
Model 1500
Figure 1
Model 1300
-7-
LOCATING THE FURNACE
1. The furnace should be located in the same room as the
central system and as close as possible, but not closer than
9". There should be no wall between the furnace and the
warm air outlet duct that is connected directly to the warm
air outlet plenum of the central furnace. (See Fig. 4)
2. Place the furnace on a noncombustible oor.
3. Check gures 3 through 5. Be sure you have the clearances
shown below from the furnace and the connector pipe to
combustible surfaces. If you have a solid brick or stone wall
behind your furnace, you can place the furnace as close as
you wish to the wall. If the wall is only faced with brick or
stone, treat it as a combustible wall.
18"
18"
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
NON-COMBUSTIBLE FLOOR
12"
9"
48"
18"
CENTRAL
FURNACE
6" CHIMNEY
21"
Figure 4
Figure 5
1300 1500
Unit to Sidewall
12"
(305mm)
12"
(305mm)
Unit to Backwall
30"
(760mm)
30"
(760mm)
Front of Unit to
Combustible
48"
(1.22m)
48"
(1.22m)
Chimney Pipe
to Sidewall
18"
(460mm)
21"
(530mm)
Chimney Pipe
to Backwall
18"
(460mm)
18"
(460mm)
Plenum to
Combustibles
6"
(150mm)
6"
(150mm)
2" MIN. AIR SPACE
REQUIRED BY CODE
CENTRAL
FURNACE
6" MIN.
PLENUM
TO
CEILING
Figure 3
-8-
10'
2' MIN.
3' MIN.
6" CHIMNEY CONNECTOR
6" ELBOW
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
REFER TO CHIMNEY
MANUFACTURER'S
INSTRUCTIONS AND
PARTS.
Chimney Connection
MASONRY CHIMNEY
Before using an existing masonry chimney, clean the chimney
and inspect the ue liner to be sure it is safe to use. Make repairs
before attaching the furnace. The connector pipe and ttings you
will need to connect directly to a masonry chimney are shown.
The chimney connection should be as short as possible.
If the connector pipe must go through a combustible wall before
entering the masonry chimney, consult a qualied mason or
chimney dealer. The installation must conform to local re codes,
and N.F.P.A. 211.
DO NOT CONNECT THIS FURNACE TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
The chimney used for a furnace must not be used to ventilate the
cellar or basement. If there is a cleanout opening at the base of
the chimney, close it tightly.
LISTED FACTORY BUILT CHIMNEY
Carefully follow chimney manufacturer's instructions. Use only a
Listed Residential Type or Building Heating Appliance Chimney.
If your chimney starts at the ceiling (Fig. 7), you will need enough
6" pipe to reach the ceiling.
The top of the chimney must be at least 3 feet above the roof
and be at least 2 feet higher than any point of the roof within 10
feet (Fig. 7).
IMPORTANCE OF PROPER DRAFT
Draft is the force which moves air from the appliance up through
the chimney. The amount of draft in your chimney depends on the
length of the chimney, local geography, nearby obstructions and
other factors. Too much draft may cause excessive temperatures
in the appliance. Inadequate draft may cause backpufng into the
room and ‘plugging’ of the chimney.
“Inadequate draft will cause the appliance to leak smoke into the
room through appliance and chimney connector joints.”
“An uncontrollable burn or excessive temperature indicates ex-
cessive draft.”
Take into account the chimney’s location to insure it is not too
close to neighbors or in a valley which may cause unhealthy or
nuisance conditions.
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
THIMBLE
6" ELBOW
6" CHIMNEY
CONNECTOR
6" ELBOW
NON-COMBUSTIBLE WALL
Figure 6
Figure 7
-9-
1. The crimped end of the chimney connector ts inside the furnace
ue collar. Install additional chimney connectors and elbow with
the CRIMPED END TOWARD THE FURNACE. This will allow any
condensation in the ue to run back into the furnace. Use 6" dia.
steel pipe and elbows for connection to chimney. Never use less
than 24 gauge and although blued steel is satisfactory, high temp
painted black is much more desirable. (See Figure 8)
2. Slope any horizontal pipe upward toward the chimney at least 1/4
inch for each foot of horizontal run.
3. You must have at least 18 inches of clearance between any hori-
zontal piping and the ceiling.(See Fig. 5)
4. The chimney connector must not extend into the chimney ue. (See
Fig. 9)
5. Seal each chimney connector pipe joint with furnace cement. Also
seal the pipe at the chimney.
6. Use 3 sheet metal screws at each chimney pipe joint to make the
piping rigid.
7. The chimney connector may include a section for a barometric
draft regulator between the furnace and the chimney (Fig. 6, 7, &
10). The barometric draft regulator must be installed in the same
room (same pressure zone) as the furnace.
8. Install the barometric draft regulator strictly in accordance with the
instructions that are provided with the barometric draft regulator.
9. A solid damper must be used in the chimney connecting pipes be-
tween the ue collar and the chimney. When used in conjunction
with a barometric draft regulator, the solid damper must be placed
between the barometric and the chimney. (See Fig. 6, 7, & 10)
ADJUSTING THE BAROMETRIC DRAFT
REGULATOR
1. Drill a hole in the chimney connector within 18" of the ue collar
below the barometric draft regulator just large enough for the tube
of the manometer.
2. Build a re after all chimney connections have been made.
3. Use a manometer to measure the draft in the ue.
4. Adjust the Barometric Draft Regulator to obtain a draft of 0.05 -
0.06" W.C. under stable re conditions.
RIGHT WRONG WRONG
6" SOLID DAMPER
6" BAROMETRIC
DRAFT REGULATOR
NON COMBUSTIBLE
INSTALLATION PER
NFPA 211
MEASURE FLUE DRAFT HERE
Figure 9
Figure 10
Rules for Connector Pipe Installation
NOTE:
A ue pipe shall not pass through an attic, roof
space, closet or similar concealed space, a oor
or ceiling of combustible construction. Where
passage through a wall or partition is desired,
installation must conform with UL standards.
Figure 8
-10-
CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY
THROUGH A COMBUSTIBLE WALL
Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall.
There are ve allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall.
NFPA Standard 211 allows the following wall pass-through systems.
Figure 11
-11-
1. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A reclay liner (ASTM C315 or
equivalent) having a 5/8" minimum wall thickness must be used and it must be at least 12" away from any material
that could catch re. The inside diameter of the reclay liner shall be sized for the proper snug t of a 6" diameter
chimney connector pipe. The reclay liner shall run from the outer surface of the brick wall to, but not beyond, the
MINIMUM 12 IN.
TO COMBUSTIBLES
FIGURE 12, PART A
CHIMNEY FLUE
MINIMUM CHIMNEY CLEARANCE TO
BRICK AND COMBUSTIBLES IS 2 IN.
MINIMUM CLEARANCES 12 IN.
OF BRICK ALL AROUND
CHIMNEY CONNECTOR
TO HEATER
FIRE CLAY LINER
(5/8" MIN. WALL THICKNESS)
MIN. 3-1/2" THICK BRICK
MASONRY WALL
MASONRY CHIMNEY
CONSTRUCTED TO
NFPA 211
FIGURE 12, PART B
AIR SPACE
9 IN. MINIMUM
FACTORY-BUILT
CHIMNEY LENGTH
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
CHIMNEY LENGTH
FLUSH WITH INSIDE
OF FLUE
NONSOLUBLE
REFACTORY
CEMENT
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
CHIMNEY CONNECTOR
TO HEATER
MINIMUM CLEARANCE
9 IN. ALL AROUND
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
CHIMNEY FLUE
SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY LENGTH
USE CHIMNEY MFRS. PARTS TO
ATTACH CONNECTOR SECURELY
AIR SPACE
inner surface of the chimney ue and shall be rmly cemented in place. See Part A.
2. Use a solid insulated listed factory-built chimney length having an inside diameter of 6" and having 1" or more of solid
insulation. There must be at least a 9" air space between the outer wall of the chimney length and any combustible
materials. The inner end of the chimney length shall be ush with the inside of the masonry chimney ue and shall be
sealed to the ue and to the brick masonry penetration with nonwater-soluble refractory cement. Sheet steel supports
TWO VENTILATED AIR
CHANNELS EACH 1 INCH.
CONSTRUCTED OF
SHEET STEEL.
FIGURE 12, PART C
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
MINIMUM 6 IN. GLASS
FIBER INSULATION ALL AROUND
24 GAUGE
VENTILATED THIMBLE WITH
TWO 1 INCH AIR CHANNELS
CHIMNEY THIMBLE
CHIMNEY FLUE
CHIMNEY CONNECTOR
TO HEATER
which are at least 24 gauge (0.024") in thickness shall be securely fastened to wall surfaces on all sides. Fasteners
between supports and the chimney length shall not penetrate the chimney liner. See Part B.
3. Use a 10" diameter ventilated thimble made of at least 24 gauge (0.024") steel having two 1" air channels. The venti-
lated thimble must be separated from combustible materials by a minimum of 6" glass ber insulation. The opening
-12-
SHEET STEEL SUPPORTS
CHIMNEY SECTION
CHIMNEY
CONNECTOR
AIR SPACE
2 IN.
FIGURE 12, PART D
MINIMUM CLEARANCE
2 IN. ALL AROUND
CHIMNEY THIMBLE
1 IN. AIR SPACE TO
CHIMNEY LENGTH
MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211
SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)
CHIMNEY FLUE
MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
CHIMNEY CONNECTOR
TO HEATER
SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY
LENGTH (12 IN. LONG MIN.)
in the combustible wall shall be covered and the thimble
supported with sheet steel supports which are at least 24
gauge (0.024") in thickness. The sheet steel supports shall
be securely fastened to wall surfaces on all sides and shall
be sized to t and hold the chimney section. Fasteners used
to secure chimney sections shall not penetrate chimney ue
liner. See Part C.
4. Use an 8" inside diameter solid insulated listed factory-built
chimney length which has 1" or more of solid insulation. The
minimum length of this chimney section shall be 12" and
will serve as a pass-through for the 6" diameter chimney
connector. There must be at least a 12" air space between
the outer wall of the chimney section and any combustible
materials. The chimney section shall be concentric with
and spaced 1" away from the chimney connector by means
of sheet steel support plates on both ends of the chimney
section. The opening in the combustible wall shall be cov-
ered and the chimney section supported on both sides with
sheet steel supports which are at least 24 gauge (0.024")
in thickness. The sheet steel supports shall be securely
fastened to wall surfaces on all sides and shall be sized to
t and hold the chimney section. Fasteners used to secure
chimney sections shall not penetrate chimney ue liner. See
Part D.
5. A listed factory-built wall pass-through system may be pur-
chased and installed according to the instructions packaged
with it to provide a safe method of passing the chimney
connector through a combustible wall for connection to a
masonry chimney.
Additional requirements pertaining to Figure 8 and
the above wall pass-through systems:
1. Insulation material used as part of wall pass-through sys-
tem shall be of noncombustible material and shall have a
thermal conductivity of 1.0 Btu • in./ft.² • °F (4.88 kg cal/
hr • m² • °C) or less.
2. All clearances and thicknesses are minimums: larger clear-
ances and thickness are acceptable.
3. A chimney thimble, as shown for 3" and 4" above (Parts C
and D) shall be for types "3" and 4" connections to facili-
tate removal of the chimney connector for cleaning. The
chimney thimble shall be of ASTM C315 reclay with 5/8"
minimum wall thickness, or material or equivalent durabil-
ity. The inside diameter of the thimble shall be sized for
the proper snug t of a 6" diameter chimney connector
pipe. The thimble shall be installed without damage to the
chimney ue. The thimble shall extend through the chimney
wall to, but not beyond, the inner surface of the chimney
ue and shall be permanently cemented in place with high
temperature cement.
4. A chimney connector to a masonry chimney, except for 2"
above (Part B), shall extend through the wall pass-through
system to the inner face of the chimney ue, but not beyond.
It does not have to be fastened in place so long as it cannot
accidently be pulled out of the chimney or shoved into the
chimney ue. If fasteners are used to secure the chimney
connector to a masonry chimney, the fasteners shall not
penetrate the chimney ue liner.
5. Any material used to close up any opening for the connector
shall be noncombustible.
PART E - (Figure 12)
In addition to the methods shown by A, B, C, and D of
Figure 12, a listed factory-built wall pass-through system
may be purchased and installed according to the instruc-
tions packaged with it to provide a safe method of pass-
ing chimney connector through a combustible wall for a
connection to a masonry chimney.
If the chimney connector does not have to pass through a
combustible wall to get to a masonry chimney, simply con-
nect the chimney connector directly to the masonry chimney's
chimney thimble as described and shown by parts C and D of
Figure 12. Remember, the chimney connector should extend
into the chimney thimble to the inner face of the chimney ue
but not beyond; if the chimney connector is extended through
the chimney thimble into the chimney ue, resistance to the
ow of smoke and gases up the chimney will occur; that ow
resistance will have an adverse affect on the operation and
performance of the heater and venting system.
CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHIMNEY CONNECTOR
DOES NOT PASS THROUGH A COMBUSTIBLE WALL
-13-
THERMODISC
THERMODISC
COVER
4” ELECTRICAL
JUNCTION BOX
BLOWERS
BLOWERS GASKET
CLIP NUTS
(Not used in the upper center hole.)
ASSEMBLY OF FURNACE
Your furnace requires the following items to be assembled or
installed by the service person:
Feed Door Pull Handle
Feed Door Locking Handle
Blowers and Blower Controls
Electrical Connections
1. Remove all parts from inside the furnace and inspect for
damage, including the rebrick as some breakage could
occur during shipment.
2. Assemble the feed door pull handle as shown in Figure
13. Install thermostat assembly and cover (complete with
handle) as illustrated in Figure 13b.
3. Align thermostat control knob with at on thermostat control
shaft and press onto shaft. (See Fig. 13a)
4. Attach feed door locking handle as in Figure 14 with screws
and nuts provided. Note: Slotted holes are for adjustment
of handle. Adjust handle until some pressure is required
to lock feed door during ring sequence.
5. Install the thermodisc on rear of furnace cabinet with the
two screws provided. Mount the conduit assembly from
the junction box to the thermostat bracket. Crimp the two
female terminals to each of the wire leads. Plug the wires
to the thermodisc. NOTE: It does not matter which of the
two wires plugs to which terminal on the thermodisc.
6. Remove blowers from cartons. Remove junction box
cover. Attach clip nuts as in Figure 15. Install blower(s)
and gasket(s) with 1/4"-20 x 3/4" bolts as shown.
7. Wire right side blower rst (See wiring diagram) and replace
cover on junction box on blower.
8. Wire left blower same as above and replace cover.
9. Check operation of shaker grates with grate handle before
operating furnace.
Figure 15
(Model 1300 has only one blower)
1
1
2
2
A A
B B
Figure 14
Figure 13b
SET SCREW
Figure 13a
-14-
NOTE:
For model 1300, disregard the wiring (wires M1 & M2) of one blower
motor.
Wire leads from the distribution blower are usually BOTH BLACK.
Makes no dierence which leads from the motor(s) connects to the cor-
responding leads coming out of the conduit.
Figure 16
WIRING DIAGRAM
-15-
INSTALLATION
Please see all methods of Installation at the rear of this
booklet.
This is a furnace, not a free standing stove. You must direct
heated air from 8" outlets away from the furnace, or it will not
function properly.
1. This installation must be done by a qualied heating
equipment installer.
2. The installation is to be done in compliance with National
Fire Protection Association installation standards: No.
89M, 90B, 211, 70 (National Electrical Code) and Uniform
Mechanical Code 913, 6-4, in the states where applicable.
(Their code offers connecting smoke pipe connectors into
chimney with other fuel burning appliances.)
3. Rooms large in comparison with size of the appliance:
a) Coal Burning Furnace need air for combustion and
circulation to house.
b) Provision must be made to make up this air and not
starve gas or oil furnace of combustion air.
c) Have the "Authority Having Jurisdiction" determine that
air is of adequate makeup. (Reference N.F.P.A. Nos.
30&54, Code for Installation of Gas & Oil Equipment).
4. Have the "Authority Having Jurisdiction" to inspect all
chimneys and installations for adequate venting and for
compliance with standard and local codes and regulations
regarding installation of coal burning appliances.
5. Installation for Supplemental Heat Application to Existing
Central System.
a) Place Coal Burning Furnace so that the chimney
connector will be as short as practical and avoiding
unnecessary sharp turns in the smoke pipe connector
and the installation of devices that would create
excessive resistance to the ow of ue gases.
b) Locate the Coal Burning Furnace as close as practical to
the existing central hot air heating system, maintaining
clearances as stated on the label on the fuel door.
c) Clearance from combustible materials must comply with
those stated on the label on the side of the unit. Refer
to the clearance table in the front of this manual.
The installation must be made only on a noncombustible oor.
d) Install the smoke pipe connector to the chimney with
26-gauge pipe and elbows (to be purchased separately),
maintaining the proper clearances for the specic model.
Seal the smoke pipe in the chimney with furnace cement.
(The chimney connector shall be securely supported,
and joints fastened with sheet metal screws or rivets.)
e) Install 8" diameter heat pipe to plenum of the central
hot air furnace. Use 26-gauge pipe and connectors (to
be purchased separately). If central air conditioning is
installed in the plenum, install heat pipe above the air
conditioning unit. Secure heat pipe connection with
supports and sheet metal screws.
f) Connect electrical supply in the electrical junction box
that is mounted on the back of the Furnace. See Wiring
Diagram (Fig. 16). Remove the cover from electrical
junction box and connect power supply wires to wires
designated, using wire nuts. The power cord supplied
may be used for installation, if permitted by local codes
and regulations. If the power cord supplied cannot be
used, the power supply wiring must be 90 degrees
centigrade in a metal cable and should be completed
by a qualied installer complying with NFPA Standard
No. 70 and local codes.
POWER FAILURE
INSTRUCTIONS
Operation after loss of power:
1. Removelterifprovided
2. Do not expect to keep home at normal temperatures.
3. Do not load fuel above bottom of feed door.
The top down method of re building is recommended for
this appliance.
DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners, or
asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Saltwater driftwood or other previously saltwater saturated
materials;
Burning these materials may result in release of toxic fumes
or render the heater ineffective and cause smoke.
TAMPER WARNING
This coal heater has a manufacturer-set minimum low burn
rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this coal heater in a
manner inconsistent with operating instructions in this manual.
VISIBLE SMOKE
The amount of visible smoke being produced can be an effective
method of determining how efciently the combustion process
is taking place at the given settings. Visible smoke consist of
unburned fuel and moisture leaving your stove. Learn to adjust
the air settings of your specic unit to produce the smallest
amount of visible smoke.
-16-
A draft reading of .05 to .06 w.c. is suggested for proper burning of this unit when using bituminous
coal as fuel. When using anthracite coal, this draft reading is a minimum reading.
CAUTION
Achimneyremaycauseignitionofwallstudsorrafterswhichyouthoughtwereasafedistancefrom
thechimney.Ifyouhaveachimneyre,haveyourchimneyinspectedbyaqualiedpersonbefore
using again.
EFFICIENCIES
Efciencies can be based on either the lower heating value
(LHV) or the higher heating value (HHV) of the fuel. The lower
heating value is when water leaves the combustion process
as a vapor. The higher heating value is when water leaves
the combustion process completely condensed.
OVER FIRING
Attempts to achieve heat output rates that exceed heater design
specications can result in permanent damage to the heater.
ASH REMOVAL AND DISPOSAL
Whenever ashes get 3 to 4 inches deep in your rebox or ash
pan, and when the re has burned down and cooled, remove
excess ashes. Leave an ash bed approximately 1 inch deep
on the rebox bottom to help maintain a hot charcoal bed.
Ashes should be placed in a metal container with a tight-
tting lid. The closed container of ashes should be placed
on a noncombustible oor or on the ground, away from all
combustible materials, pending nal disposal. The ashes
should be retained in the closed container until all cinders
have thoroughly cooled.
SMOKE AND CO MONITORS
CO is a poisonous gas when exposed to elevated concentrations
for extended periods of time. While the modern combustion
systems in heaters drastically reduce the amount of CO emitted
out the chimney, exposure to the gases in closed or conned
areas can be dangerous. Make sure your stove gaskets and
chimney joints are in good working order and sealing properly
to ensure unintended exposure. It is recommended that you
use both smoke and CO monitors in areas having the potential
to generate CO.
GASKETS
It is recommended that you change the door gasket (which
makes your stove door air tight) once a year, in order to
insure good control over the combustion, maximum efciency
and security. To change the door gasket, simply remove the
damaged one. Carefully clean the available gasket groove,
apply a high temperature silicone sold for this purpose, and
install the new gasket. You may light up your stove again
approximately 24 hours after having completed this operation.
This unit’s ash door uses a 5/8" diameter rope gasket. This
unit's feed door uses a 1/2" diameter rope gasket.
SERVICE HINTS
Do not expect a furnace to draw. It is the chimney that
creates the draft. Smoke spillage into the house or
excessive build-up of water or creosote in the chimney
are warnings that the chimney is not functioning properly.
Correct the problem before using furnace. Possible causes are:
1. The connector pipe may be pushed into the chimney too
far, stopping the draft.
2. Do not connect two furnaces or a stove and furnace into
the same chimney ue.
3. The chimney used for a furnace must not be used to
ventilate the cellar or basement. If there is a cleanout
opening at the base of the chimney, it must be closed tightly.
4. If the chimney is operating too cool, water will condense
in the chimney and run back into the furnace. Creosote
formation will be rapid and may block the chimney. Operate
the furnace at a high enough re to keep the chimney
warm, preventing this condensation.
5. If the re burns well, but sometimes smokes or burns
slowly, it may be caused by the chimney top being lower
than another part of the house or a nearby tree. The
wind blowing over a house or a tree, falls on top of the
chimney like water over a dam, beating down the smoke.
The top of the chimney should be at least 3 feet above
the roof and be at least 2 feet higher than any point of
the roof within 10 feet.
6. See page 18 for list of trouble shooting tips.
CHIMNEY MAINTENANCE
Creosote and Soot - Formation and Need for Removal
When coal is burned, the products of combustion combine with
moisture to form a soot residue which accumulates on the ue
lining. When ignited, this soot makes an extremely hot re.
The chimney should be inspected at least twice monthly
during the heating season to determine if a creosote or soot
build up has occurred.
If creosote or soot has accumulated, it should be removed to
reduce the risk of a chimney re.
Chimney res burn very hot. If the chimney catches re,
immediately call the re department, then reduce the re by
closing the inlet air control. Pour a large quantity of coarse
salt, baking soda or cool ashes on top of the re in the rebox.
ATTENTION:
This heater needs periodic inspection and repair for proper operation. It is against federal regulations
to operate this heater in a manner inconsistent with operating instructions in this manual.
-17-
TROUBLE SHOOTING TIPS FOR WARM AIR FURNACE
1. Problem:
Smoke puffs from furnace
Solution:
A. Check chimney draft. Check for blocked chimney or
ue pipe. Use mirror to check chimney clearance.
B. Check ash pit — if it is too full, empty.
C. Make sure furnace room is not too airtight.
D. Make sure all of chimney mortar connections are airtight.
E. Check ash drawer. Make sure it’s airtight.
F. Check chimney for possible down-draft caused by
taller surrounding trees or objects. Correct with proper
chimney vent cap.
G. Check the possibility of a cold chimney forcing cool
gases backward. Remedied by properly insulating
chimney with non-combustible liner non-combustible
insulation.
H. Fuel may be too green.
I. Make sure no other fuel burning devices are connected
to the chimney impairing the draft.
J. Check chimney draft, it should be .06 inches of water
column. This service is provided by a certied chimney
sweep.
2. Problem:
Inadequate heat being delivered to your home
Solution:
A. Check home insulation — is it adequate?
B. Check hook-up to furnace — is it installed correctly?
C. Cool air inlet may be inadequate or furnace room too
airtight.
D. Make sure your hot air duct (and other duct work) is
airtight.
E. If furnace room is warm but your home isn’t, check
back draft dampers.
F. Is air to the blower available?
3. Problem:
Excess smoke or ames coming out door when refueling
Solution:
A. Wait 15 seconds and open door SLOWLY then
refuel.
B. Check length of ue pipe to chimney. Your unit should
be within six (6) feet of your chimney.
C. Make sure chimney cap is not too close to the top of
the chimney.
D. Check chimney draft — make sure chimney ue pipe
is clean and chimney is of adequate height.
E. Slide bafe should be pulled out prior to load door
opening.
4. Problem:
Distribution blower vibrating
Solution:
A. Tighten blower wheel to motor shaft.
B. Check for bad fan bearings.
5. Problem:
Distribution blower continues to run or will not run
Solution:
A. Check fan limit or heat sensor and cable.
B. Check to see that blower is properly wired.
(See Wiring and Assembly Instructions).
C. Check fuse box or power source.
D. Check power supply.
6. Problem:
Odor from rst re
Solution:
A. The odor from new steel should disappear in a few
hours.
B. If the odor remains, call you dealer immediately. A bad
weld can cause a fume leak.
7. Problem:
Excessive Creosote
Solution:
A. Make sure your unit is serviced by its own proper
chimney.
B. Check length of ue pipe and its connections.
C. Make sure you are burning the smallest, hottest re to
adequately heat your home.
D. Also see Solutions to Problem one.
8. Problem:
If the re goes out or does not hold over night
Solution:
A. Poor Draft.
B. Incorrect damper settings.
C. Improper ring methods if burning coal.
D. More combustion air needed.
E. Coal not sized to the furnace. We recommend 1” to 3”
diameter pieces of coal.
F. Ashes, if allowed to accumulate in the ash pit, will not
allow passage of the required air for combustion. Keep
ash pit clean.
G. This furnace is not to be used with an automatic stoker
unless so certied.
-18-
Repair Parts
22
6
8
7
9
20
18
19
17
16
14
10
15
11
12
13
21
1
5
2 3
4
1
28
27
26
29
30
31
24
25
32
33
23
36
34
39
38
37
41
34
35
39
37
38
40
40
42
34
22
6
8
7
9
20
18
19
17
16
14
10
15
11
12
13
21
1
5
2 3
4
1
28
27
26
29
30
31
24
25
32
33
23
36
34
39
38
37
41
34
35
39
37
38
40
40
42
34
22
6
8
7
9
20
18
19
17
16
14
10
15
11
12
13
21
1
5
2 3
4
1
28
27
26
29
30
31
24
25
32
33
23
36
34
39
38
37
41
34
35
39
37
38
40
40
42
34
1300
1500
-19-
1
25541R
Cabinet Side (Left & Right)
1300
2
25467R
1500
2 88032 Flue Collar Gasket 2
3 40246 Flue Collar 1
4
25540R
Cabinet Back
1300
1
23459R
1500
5
25561R
Cabinet Top
1300
1
25466R
1500
N/S 891214 8" Collar 2
6 68217 Feed Door Assy. (Includes Gasket - 88057) 1
7 22662 Bracket, Feed Door 1
8 24232 Spacer, Hinge 1
9 891097 Locking Mechanism, Feed Door 1
10 68218 Ash Door Assy. (Includes Gasket - 88066) 1
11 86626 Latch, Door 1
12 83461 Washer (1" OD, 7/16" ID) 1
13 83274 Lock Nut, 3/8-16 1
14 891098 Handle Assy. w/Handle Bushing 1
15 23859B Draft Cap, Painted 1
16 891135 Handle, Spring 2
17 23800 Smoke Curtain 1
18 23787 Clip, Smoke Curtain 2
19 83445 1/4-20 x 1-1/4 Carriage Bolt 2
20 83250 Kep Nut, 1/4-20 2
21
68238
Ash Pan
1300
1
68228
1500
22
23397
Bafe, Flue
1300
1
23398
1500
2
23 22761B Flue Collar Ring 1
24 22762B Forced Draft Ring 1
25 86402 1-1/2" Pipe Plug 1
26 80230 Blower
1300
1
1500
2
27 89319 Gasket, Blower
1300
1
1500
2
28 83340 1/4-20 Clipnut
1300
4
1500
8
29 22140 Relay Box Bracket 1
30 80131 Junction Box (4 x 4) 1
31 80231 Junction Box Cover 1
32 80314 Thermodisc (60T12) 1
33 68234 Blower Thermostat Bracket 1
34 89066 Firebrick (4.5 x 9 x 1.25)
1300
10
1500
12
36 40264 Liner, Front/Rear
1300
2
37 40256 Grate Frame, Shaker
1300
1
1500
2
38 40257 Grate, Shaker
1300
1
1500
2
39 40260 Handle, Shaker
1300
1
1500
40 40258 Liner - Front/Rear
1500
1
41 40269 Liner - Front
1500
1
N/S = Not Shown
Color Code: R = Red
Parts List
Key Part No. Description Model Qty.Key Part No. Description Model Qty.
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL
MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE
APPLIANCE MANUFACTURER.
USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
-20-
1
1
2
2
3
3
4
4
A A
B B
1
2
10
11
9
7
12
5
4
6
8
3
7
13
- 69921R Thermostat Box Assembly (Color - Red)
-
** 69921G Thermostat Box Assembly (Color - Green)
-
1 68722 Thermostat Panel Weldment 1
2 68732 Thermostat Cover Weldment (Color - Red) 1
** 68732G Thermostat Cover Weldment (Color - Green) 1
3 23429 Thermostat Step Plate 1
4 23431 Friction Plate 1
5 81903 Thermostat 1
6 23427 Thermostat Mounting Bracket 1
7 83172 #10 Sheet Metal Screw 6
8 89041 Spring 1
9 89175 Thermostat Knob 1
10 23425 Handle Bracket 2
11 89520 Wooden Handle 1
12 86318 Thermostat Chain .542 FT
13 68217 Feed Door Assembly (Includes Door and Gasket) 1
N/S 83106S Machine Screw, 10-24 x 1/2" SL HD Z 2
N/S 83136 Washer, 9/32" I.D. - 5/8" O.D. - 1/16" THK. 1
N/S 83816 Cotter Pin, 1/16" x 3/4" 1
Parts Diagram/List
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL
MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE
APPLIANCE MANUFACTURER.
USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Hotblast 1300 Le manuel du propriétaire

Catégorie
Poêles
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues