LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
INSTALLATION INSTRUCTIONS
Universal Voltage (120-277V) LED Luminaire Retrofit Kit
VPR-22-MU-25-9TW-A
VPR-24-MU-36-9TW-A
Reference spec sheet for full part numbers
INS-VPR, Rev A
11/17/2022
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 · Telephone: 1-323-779-2980 · Fax: 1-323-754-9060 [email protected] www.fulham.com
Installation Instructions subject to change without notice. Page 2 of 6
INSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM
INS-VPR, Rev A
LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
11/17/2022
Installation Warnings
To reduce the risk of death, personal injury, property damage from fire, electric shock, falling parts, cuts/abrasions,
and other hazards make sure to read all warnings and instructions included with and on the fixture box and all fixture labels.
Follow these general precautions before installing, servicing, or performing routine maintenance upon this equipment.
Commercial installation, service, and maintenance of luminaires should be performed by a qualified licensed
electrician.
LED Retrofit kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a
qualified electrician.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
Warnings
Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Turn off the power prior to performing any maintenance
Verify that the supply voltage is correct by comparing it with the luminaire label information.
All wiring connections should be capped with UL approved wire connectors.
Caution
Avoid direct eye exposure to the light source while it is on.
Account for small parts and properly dispose of packing material, as these may be hazardous to children.
Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
Avertissements d'installation
Pour réduire le risque de décès, de blessures corporelles, de dommages matériels dus à un incendie, un choc électrique, la chute de pièces, des
coupures/abrasions, et autres dangers, assurez-vous de lire tous les avertissements et instructions inclus avec et sur la boîte du luminaire et
toutes les étiquettes du luminaire.
Suivez ces précautions générales avant d'installer, d'entretenir ou d'effectuer un entretien de routine sur cet équipement.
L'installation commerciale, l'entretien et la maintenance des luminaires doivent être effectués par un électricien.
L'installation du kit LED Retrofit nécessite une connaissance des systèmes électriques des luminaires. Si vous n'êtes pas qualifié, ne tentez pas
l'installation. Contactez un électricien qualifié.
Pour éviter d'endommager le câblage ou de l'abrasion, n'exposez pas le câblage aux bords de la tôle ou à d'autres objets pointus.
Ne faites ni ne modifiez aucun trou ouvert dans un boîtier de câblage ou de composants électriques pendant l'installation du kit.
Avertissements
Coupez l'alimentation électrique au niveau de la boîte à fusibles ou du disjoncteur avant de câbler le luminaire à l'alimentation électrique.
Couper l'alimentation avant d'effectuer tout entretien.
Vérifiez que la tension d'alimentation est correcte en la comparant aux informations de l'étiquette du luminaire.
Toutes les connexions de câblage doivent être coiffées de connecteurs de fil approuvés UL.
Mise en garde
Évitez l'exposition directe des yeux à la source lumineuse lorsqu'elle est allumée.
Tenez compte des petites pièces et éliminez correctement les matériaux d'emballage, car ils peuvent être dangereux pour les enfants.
Risque de brûlure. Débranchez l'alimentation et laissez le luminaire refroidir avant de changer l'ampoule ou de manipuler le luminaire.
NOTE: The green ground screw is installed in its proper location. Do not Relocate.
NOTE: Please use minimum 90°C rated supply conductors.
NOTE: Specifications and dimensions subject to change without notice.
NOTE: Suitable for Dry and Damp location, Type IC.
REMARQUE: La vis de terre verte est installée à son emplacement approprié. Ne déménagez pas.
REMARQUE: Veuillez utiliser des conducteurs d'alimentation d'au moins 90 °C.
REMARQUE: Spécifications et dimensions sujettes à modification sans préavis.
REMARQUE: Convient aux emplacements secs et humides, type IC.
Risk of fire or electric shock. The electrical rating of these products are 120-277 VAC, the
installer must determine whether they have 120-277 V at the luminaire before installation.
Risk of fire or electric shock. Install this kit only in the luminaires that have the
construction features and dimensions shown in the photographs and /or drawings.
Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when
drilling for installation of LED retrofit kit. Check for enclosed wiring and components.
Risque d'incendie ou de choc électrique. Les caractéristiques électriques de ces produits
sont de 120-277 VAC, l'installateur doit déterminer s'il dispose de 120-277 V au niveau du
luminaire avant l'installation.
Risque d'incendie ou de choc électrique. Installez ce kit uniquement dans les luminaires
qui présentent les caractéristiques de construction et les dimensions indiquées sur les
photographies et/ou les dessins.
Risque d'incendie ou de choc électrique. Le câblage et les composants électrique du
luminaire risquent d'être endommagés lors du perçage pour l'installation du kit de mise à
niveau pour LED. Vérifiez si le câblage et les composants sont enfermés.
Retrofit Kit Components
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 · Telephone: 1-323-779-2980 · Fax: 1-323-754-9060 [email protected] www.fulham.com
Installation Instructions subject to change without notice. Page 3 of 6
INS-VPR, Rev A
INSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM
General Wiring Diagram
A: End Brackets................................
B: Side Brackets...............................
C: Retrofit KitHousing.......................
D: #8 x 1/2” Self-Taping Screws.......
E: Wire Caps....................................
F: Retrofit Label................................
2pcs
2pcs
1pcs
4pcs
3pcs
1pcs
D
C
B
A
E
F
NOTE: The existing fluorescent luminaries housing shall be larger than dimensions described in below table:
2' x 2'
2' x 4'
Housing Designation Overall Dimensions
24.0" x 23.94" x 3.07"H (610 x 608 x 78mm H)
48.0" x 23.94" x 3.07"H (1220 x 608 x 78mm H)
Purple (0-10V Dim+)
Pink (AUX & 0-10V Dim-)
Gray (LED CH1-)
White (LED+)
Black (LED CH2-)
Yellow (AUX 12V+)
120-277V
Black (Line)
White (Neutral) To LED Load
LED DRIVER
0-10V Dimming
Wires / Sensor
Power Dip Switch CCT Dip Switch
LOW HIGH LOW HIGH
Luminaire Input Connector
(WAGO 873 or Ideal 102X)
LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
11/17/2022
Field-Adjustable Wattage & CCT
CCT Switch Wattage Switch
Part Number Power Level CCT Level
VPR22-MU-25-9TW-A
23W / 30W / 36W
3500K - 5000K
VPR24-MU-36-9TW-A
18W / 22W / 25W
3500K - 5000K
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 · Telephone: 1-323-779-2980 · Fax: 1-323-754-9060 [email protected] www.fulham.com
Installation Instructions subject to change without notice. Page 4 of 6
INS-VPR, Rev A
INSTALLATION INSTRUCTIONS
LED LIGHT ENGINE APPLICATION PROGRAM
Adjustable lumen output and color temperature can be set to the desired output using the two DIP switches
shown above. Each DIP switch has 3 options corresponding to the three available (Low, Medium and High)
color temperatures and power levels.
1. DIP switches are located on the side of the retrofit kit housing.
2. Select a wattage and temperature by sliding each switch left or right to set the desired value.
See below for available options:
* Default factory setting is the lowest CCT level (3500K) and the highest power Level (25W/36W).
LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
11/17/2022
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 · Telephone: 1-323-779-2980 · Fax: 1-323-754-9060 [email protected] www.fulham.com
Installation Instructions subject to change without notice. Page 5 of 6
INSTALLATION INSTRUCTIONS
Installation
LED LIGHT ENGINE APPLICATION PROGRAM
INS-VPR, Rev A
Prior to installation, disconnect all incoming power to the fixture. Remove existing hardware (lens/lens frame, parabolic
louver, reflector/ballast covers, brackets, lamps/lamp holders). Leave supply and grounding leads. (Fig. 1)
NOTE: Follow all federal and local regulations when disposing of lamps and removed components.
Install the end brackets to each end of the existing fixture by gently lifting the fixture and placing the end brackets
between the fixture and T-grid. (Fig. 2)
If you are not pleased with the side gap between the fixture and T-grid, you may install the side brackets between the
fixture and T-grid. There are two tabs to allow for placing the side brackets into the slots on the end brackets. (Fig. 3)
Secure the end brackets to the existing fixture using the provided #8 x 1/2” self-drilling screws. (Fig. 2A)
Place the retrofit kit housing into the slotted keyholes of the end brackets, and the slide it horizontally to the end of the
slots. (Fig. 4 & 4A)
Hook the safety cables onto the holes positioned on the end brackets. (Fig. 5)
Use the provided wire caps to connect the wire leads of the retrofit kit housing to the main power leads.
(Black-Live, White-Neutral, Green-Grounding) (Fig. 5B)
Place the provided Retrofit Label on the original luminaire housing in a readily visible location for anyone attempting to
service the luminaire. (Fig. 5-A)
Secure the retrofit kit housing by locking the latches onto the end brackets. (Fig. 6)
Figure 1 Figure 3
Figure 4 Figure 6
Figure 5
Figure 2A
Figure 2
Figure 4A
Figure 5B
Safety cable
Figure 5A
keyhole
Hinges
Locking Latch
LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
11/17/2022
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 · Telephone: 1-323-779-2980 · Fax: 1-323-754-9060 [email protected] www.fulham.com
Installation Instructions subject to change without notice. Page 6 of 6
Emergency Battery Back-up: FHSCP-UNV-4W-L
LED LIGHT ENGINE APPLICATION PROGRAM
INSTALLATION INSTRUCTIONS
INS-VPR, Rev A
Additional Accessories (Sold Separately)
4W Constant Power Emergency Back-up
500lm
90 min.Runtime.
LED LUMINAIRE RETROFIT KIT INSTALLATION MANUAL
FOR PANEL LUMINAIRES
11/17/2022
PURPLE (0-10V DIM+)
PINK (AUX & 0-10V DIM-)
YELLOW (AUX 12V+)
Wiring Diagram 1: 3500K Emergency Output
Wiring Diagram 2: 5000K Emergency Output
WHITE (N)
BLACK (L)
BLACK
GRAY (- CH1)
WHITE + (From LED driver)
WALL
SWITCH
HOT ( 100V ~ 277V)
WHT/BLK (N-OUT)
BLUE/WHITE
RED/WHITE
WHITE
TEST SWITCH
BATTERY
CONNECTOR
RED
LED DRIVER
POWER DIP SWITCH CCT DIP SWITCH
LOW HIGH LOW HIGH
BLACK (- CH2)
FHSCP-UNV-4W-L
LED ARRAY
GRAY - (35K)
BLACK- (5K)
RED +
WHITE (N)
BLACK (L)
BLACK
GRAY (- CH1)
WHITE + (From LED driver)
WALL
SWITCH
HOT ( 100V ~ 277V)
WHT/BLK (N-OUT)
BLUE/WHITE
RED/WHITE
WHITE
TEST SWITCH
BATTERY
CONNECTOR
RED
LED DRIVER
POWER DIP SWITCH CCT DIP SWITCH
LOW HIGH LOW HIGH
BLACK (- CH2)
FHSCP-UNV-4W-L
LED ARRAY
GRAY - (35K)
BLACK- (5K)
RED +
PURPLE (0-10V DIM+)
PINK (AUX & 0-10V DIM-)
YELLOW (AUX 12V+)