Important safety Notice.............................................................................................................................................3
Electrical & Installation requirements ....................................................................................................................4
Electrical requirements ........................................................................................................................................................................................ 4
Before installing the hood .................................................................................................................................................................................... 4
List of Materials.........................................................................................................................................................5
Parts supplied ..................................................................................................................................................................................................... 5
Parts not supplied ............................................................................................................................................................................................... 5
Dimensions and Clearances.....................................................................................................................................6
Ducting Options and Examples................................................................................................................................7
Venting methods.................................................................................................................................................................................................. .7
Preparation .......................................................................................................................................................................................................... 7
Installation ................................................................................................................................................................8
Installation - Ducting version................................................................................................................................................................................ 8
Installation - Ductless (Recirculating) version ................................................................................................................................................... 12
Description of the hood & Controls.......................................................................................................................16
Controls.............................................................................................................................................................................................................. 17
Maintenance ............................................................................................................................................................19
Cleaning............................................................................................................................................................................................................. 19
Grease Filter ...................................................................................................................................................................................................... 19
Replacing the light bulb...................................................................................................................................................................................... 19
Charcoal Filter.................................................................................................................................................................................................... 20
Warranty ...................................................................................................................................................................21
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring
this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
3
READ AND SAVE THESE INSTRUCTIONS
Important safety Notice
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS OR VAPOURS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off
at service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Installation Work and Electrical Wiring Must Be Done By
QualiedPerson(s)InAccordanceWithAllApplicable
Codes & Standards, Including Fire-rated Construction.
Sufcientairisneededforpropercombustionand
exhaustingofgasesthroughtheue(Chimney)offuel
burning equipment to prevent back- drafting.
Follow the heating equipment manufacturers guideline
and safety standards such as those published by the
NationalFireProtectionAssociation(NFPA),
theAmericanSocietyforHeating,
RefrigerationandAirConditioningEngineers(ASHRAE),
and the local code authorities.
When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
Ducted systems must always be vented to the outdoors.
CAUTION
To reduce risk of re and to properly exhaust air, be
sure to duct air outside - do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces, or
garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.
Install this hood in accordance with all requirements
specied.
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE.
Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite.Heatoilsslowlyonlowormediumsettings.
AlwaysturnhoodONwhencookingathighheator
whenambeingfood(I.e.CrepesSuzette,Cherries
Jubilee, Peppercorn Beef Flambe’).
Clean ventilating fans frequently. Grease should not be
allowedtoaccumulateonfanorlter.
Useproperpansize.Alwaysusecookwareappropriate
forthesizeofthesurfaceelement.
A.
B.
C.
D.
E.
F.
a)
b)
c)
d)
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
SMOTHERFLAMESwithaclose-ttinglid,cookie
sheet, or other metal tray, then turn off the gas burner or
theelectricelement.BECAREFULTOPREVENT
BURNS.Iftheamesdonotgooutimmediately,
EVACUATEANDCALLTHEFIREDEPARTMENT.
NEVERPICKUPAFLAMINGPAN-youmaybe
burned.
DONOTUSEWATER,includingwetdishclothsor
towels - a violent steam explosion will result.
Use an extinguisher ONLY if:
YouknowyouhaveaclassABCextinguisher,and
you already know how to operate it.
Thereissmallandcontainedintheareawhereit
started.
Theredepartmentisbeingcalled.
Youcanghttherewithyourbacktoanexit.
OPERATION
a.Alwaysleavesafetygrillsandltersinplace.Without
these components, operating blowers could catch onto hair,
ngersandlooseclothing.
Themanufacturerdeclinesallresponsibilityintheeventof
failure to observe the instructions given here for installation,
maintenanceandsuitableuseoftheproduct.The
manufacturer further declines all responsibility for injury due
to negligence and the warranty of the unit automatically
expires due to improper maintenance.
a)
b)
c)
d)
1)
2)
3)
4)
4
Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observeallgoverningcodesandordinances.
It is the customers responsibility:
Tocontactaqualiedelectricalinstaller.
Toassurethattheelectricalinstallationisadequateandin
conformancewithNationalElectricalCode,ANSI/NFPA70
—latestedition*,orCSAStandardsC22.1-94,Canadian
Electrical Code, Part 1 and C22.2 No.0-M91 - latest
edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommendedthataqualiedelectriciandeterminethatthe
ground path is adequate.
Do not ground to a gas pipe.
Checkwithaqualiedelectricianifyouarenotsurerange
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspectors use.
Therangehoodmustbeconnectedwithcopperwireonly.
Therangehoodshouldbeconnecteddirectlytothefused
disconnect(Orcircuitbreaker)boxthroughmetalelectrical
conduit.
WiresizesmustconformtotherequirementsoftheNational
ElectricalCodeANSI/NFPA70—latestedition*,orCSA
Standards C22.1-94, Canadian Electrical Code Part 1 and
C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.
AU.L.-orC.S.A.-listedconduitconnectormustbeprovided
at each end of the power supply conduit (at the range hood
and at the junction box).
Copies of the standards listed may be obtained from:
*NationalFireProtectionAssociationBatterymarchParkQuincy,
Massachusetts 02269
**CSAInternational8501EastPleasantValleyRoadCleveland,
Ohio44131-5575
Before installing the hood
Forthemostefcientairowexhaust,useastraightrun
or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
Atleasttwopeoplearenecessaryforinstallation.
Fittings material is provided to secure the hood to most
typesofwalls/ceilings,consultaQualiedInstaller,
checkiftheyperfectlytwithyourcabinet/wall.
Donotuseexducting.
COLDWEATHERinstallationsshouldhaveanadditional
backdraftdamperinstalledtominimizebackwardcoldair
owandanonmetallicthermalbreaktominimize
conduction of outside temperatures as part of the
ductwork.Thedampershouldbeonthecoldairsideof
the thermal break.
Thebreakshouldbeascloseaspossibletowherethe
ducting enters the heated portion of the house.
Makeupair:Localbuildingcodesmayrequiretheuseof
Make-UpAirSystemswhenusingDuctedVentilation
SystemsgreaterthanspeciedCFMofairmovement.
ThespeciedCFMvariesfromlocaletolocale.Consult
yourHVACprofessionalforspecicrequirementsinyour
area.
1.
2.
3.
4.
5.
6.
5
List of Materials
Parts supplied
Removing the packaging
CAUTION!
Remove carton carefully, Wear gloves to protect against
sharp edges.
WARNING!
Removetheprotectivelmcoveringtheproductbefore
putting into operation.
Hoodstructureassemblywithblower,transition.
4Lampsalreadyinstalled.
3Greaselter
4 Duct covers.
Hardwarebagwith:
CeilingMountTemplate
Use, care and installation guide
Woodscrews(4pieces-3/16”x1”3/4)
Assemblyscrews(71pieces)
Duct cover brackets (4 each)
8 Vertical supports.
2 Upper Ductcover supports.
2Horizontalsupports.
2TorxAdapters.
Parts not supplied
Optional Accessories
Ductless Recirculating Kit
TobeusedonlyintheDuctless(Recirculating)
versionincludes:charcoallter,charcoalltersupport
andxingbracket,deector
Tools/Materials required
Wire nuts
Tapetomounttemplate
8”roundedmetalductlengthtosuitinstallation
Measuring tape
Pliers
Gloves
Knife
Safety glasses
Electricdrillwith5/16”and3/8”Bits
Strain relief
Spirit level
Duct tape
Screwdrivers:
Phillips (Posidrive) # 2
Wirecutter/stripper
Masking tape
Hammer
Saw, jig saw or reciprocating saw
Horizontalsupport(sup)
Vertical support
Horizontalsupport(inf)
Vertical duct cover supports
Vertical support (inf)
6
Dimensions and Clearances
Ductless (Recirculating) version ONLY
* Mín 32 - 13/32”
*Max 52 - 13/32“
27”
2 - 3/8”
13 - 3/16”
12 - 1/8”
36” - 42”
** Mín 32 - 13/32”
** Max 46 - 13/32“
7
Ducting Options and Examples
Closely follow the instructions set out in this manual.
Allresponsibility,foranyeventualinconveniences,damagesorrescausedbynotcomplyingwiththeinstructionsinthis
manual, is declined.
Venting methods
ThehoodisequippedwithatransitionB for discharge of fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless
(Recirculating) version.Attachacharcoallterandthedeector F on the duct cover support bracket G. Fumes and vapours
are recycled through the top grille H by means of a duct connected to the transition B and the transition mounted on the
deector
F.
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 8” Round Pipe.
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.
Fittingsmaterialisprovidedtosecurethehoodtomosttypesofwalls/ceilings.
However,aqualiedtechnicianmustverifysuitabilityofthematerialsinaccordancewiththetypeofwall/ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Hoodinstallationheightabovecooktopistheuserspreference.Thelowerthehoodisabovethecooktop,themoreefcientthe
capturing of cooking odors, grease and smoke.
CAUTION:
FOR 8’ CEILINGS: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 27” (68,6 CM) MINIMUM ABOVE THE
COOKING SURFACE.
FOR 9’ CEILINGS: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30” (76,2 CM) MINIMUM ABOVE THE
COOKING SURFACE.
Check your ceiling height and the hood height maximum before you select your hood.
8
Installation
Installation - Ducting version
1. Pre-installation calculations
K = KitchenHeight
C = CounterHeight(36”standard)
P =PreferedHeightofHood
Bottom above counter
H = Hoodheightyourinstallation
H = K – C – P
S =ChimneyStructureHeight,yourinstallation.
S = H-1”3/8.
Select a hood preference height P that is comfortable for
the user.
CalculateHoodheightyourinstallationH=K-C-P.
ConrmthatHiswithintherangeofmintomaxHfound
foryourmodel(See“Dimensionsandclearances”
paragraph). If not adjust your installation.
Calculate Chimney structure height S. Save this
calculation for use later in the installation.
Ceiling Support Structures
Thisventhoodisheavy.
Adequatestructureandsupportmustbeprovidedinall
types of installations.
Atthehoodlocation,install2”x4”crossframingbetween
ceilingjoistsasshown.(2”x4”arerequiredtosupport
the weight of the hood.)
Arrangecrossframingintheceilingtosuit
the existing
structure.
Your ceiling joists will be like one of the following
examples.
a)
b)
c)
d)
IMPORTANT
Framing must be capable of supporting 150lbs.
9
Place the template in the ceiling considering the
instructions for ceiling support structures.
Alwaysconsiderthefrontofhoodlegendwhen
playingthetempleteontheceiling.Itwilldenethe
control’s location.
Mark with a pencil the hole locations for screws and duct
in the ceiling.
Fixtheupperhorizontalsupportwith4woodscrews.
Attachthe4lowerverticalsupports(A)tothehood
with16screwsThenattachthelowerhorizontal
support (B) whit 8 screws (inf).
Attachthe4upperverticalsupports(sup)(c)whit16
screws to adjust he desired distance.
Attachtheassemblytothesupportxedontheceiling.
Assurewithscrews(16).
click!
A
B
C
10
Connecting the ductwork
Install ductwork, making connections in the direction of
airowasillustrated.
Push duct over the exhaust outlet.
Wrapallductjointsandtheangeconnectionswithduct
tape for an airtight seal.
Make the same connection in the wall or ceiling vent
exit.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THISAPPLIANCEISFITTEDWITHANELECTRICAL
JUNCTIONBOXWITH3WIRES,ONEOFWHICH
(GREEN/YELLOW)SERVESTOGROUNDTHE
APPLIANCE.TOPROTECTYOUAGAINST
ELECTRICSHOCK,THEGREENANDYELLOWWIRE
MUSTBECONNECTEDTOTHEGROUNDINGWIRE
INYOURHOMEELECTRICALSYSTEM,ANDIT
MUSTUNDERNOCIRCUMSTANCESBECUTOR
REMOVED.
Failure to do so can result in death or electrical
shock.
Facing the front of the range hood, remove the left
knockout and the Junction box cover and install the
conduitconnector(cULuslisted)injunctionbox.
Ifnotalreadydone,install1/2”conduitconnectorinjbox.
11
Attachtheverticalductcoversupportsusing4screws.
Place upper duct covers sliding through until spring
sounds“click”.
Thenverify.
Place lower duct covers using one plastic bracket at
each vertex (4 needed).
Thelowerductcovershallbesecuredtorangehoodby4
screws.
Installthegreaselterandturnpoweronatservicepanel.
Check operation of the hood.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wiring is correct.
Togetthemostefcientusefromyournewrangehood,
readthe“UseandCareInformation”section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.
12
Installation - Ductless (Recirculating) version
IMPORTANT
Recirculating kit sold separately.
Topurchaseit,pleasedialthefollowingtollfreenumber
1-888-732-8018andrequesttheKIT02198forislandhoods.
1. Pre-installation calculations
K=KitchenHeight
C=CounterHeight(36”standard)
P=PreferedHeightofHood
Bottom above counter
H=Hoodheightyourinstallation
H=K–C–P
S=ChimneyStructureHeight,yourinstallation.
S=H-1”3/8.
Select a hood preference height P that is comfortable for
the user.
CalculateHoodheightyourinstallationH=K-C-P.
ConrmthatHiswithintherangeofmintomaxHfound
foryourmodel(See“Dimensionsandclearances”
paragraph). If not adjust your installation.
Calculate Chimney structure height S. Save this
calculation for use later in the installation.
Ceiling Support Structures
Thisventhoodisheavy.
Adequatestructureandsupportmustbeprovidedinall
types of installations.
Atthehoodlocation,install2”x4”crossframingbetween
ceilingjoistsasshown.(2”x4”arerequiredtosupport
the weight of the hood.)
Arrangecrossframingintheceilingtosuittheexisting
structure.
Your ceiling joists will be like one of the following
examples.
a)
b)
c)
d)
IMPORTANT
FramingmustbecapableIMPORTANTofsupporting150lbs.
13
Place the template in the ceiling considering the
instructions for ceiling support structures.
Alwaysconsiderthefrontofhoodlegendwhen
playingthetempleteontheceiling.Itwilldenethe
control’s location.
Mark with a pencil the hole locations for screws and duct
in the ceiling.
Fixtheupperhorizontalsupportwith4woodscrews.
Attachthe4lowerverticalsupports(A)tothehood
with16screwsThenattachthelowerhorizontal
support (B) whit 8 screws (inf).
Attachthe4upperverticalsupports(sup)(c)whit16
screws to adjust he desired distance.
Attachtheassemblytothesupportxedontheceiling.
Assurewithscrews(16).
click!
A
B
C
14
Air deector installation
Assembletheairdeectorwiththeupperhorizontal
support with 2 assembly screws.
Measurefromthebottomoftheairdeectortothebottom
of the hood outlet, as shown.
Cuttheductatthemeasuredsize.
Sliptheductontothebottomofthedeector.
Place the duct over the exhaust outlet from the hood.
Useducttapetosealthedeectorandattheexhaust
outlet from the hood.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THISAPPLIANCEISFITTEDWITHANELECTRICAL
JUNCTIONBOXWITH3WIRES,ONEOFWHICH
(GREEN/YELLOW)SERVESTOGROUNDTHE
APPLIANCE.TOPROTECTYOUAGAINST
ELECTRICSHOCK,THEGREENANDYELLOWWIRE
MUSTBECONNECTEDTOTHEGROUNDINGWIRE
INYOURHOMEELECTRICALSYSTEM,ANDIT
MUSTUNDERNOCIRCUMSTANCESBECUTOR
REMOVED.
Failure to do so can result in death or electrical
shock.
Facing the front of the range hood, remove the left
knockout and the Junction box cover and install the
conduitconnector(cULuslisted)injunctionbox.
15
Ifnotalreadydone,install1/2”conduitconnectorinjbox.
Attachtheverticalductcoversupportsusing4screws.
Place upper duct covers sliding through until spring
sounds“click”.
Thenverify.
Place lower duct covers using one plastic bracket at
each vertex (4 needed).
Thelowerductcovershallbesecuredtorangehoodby4
screws.
Installthegreaselterandturnpoweronatservicepanel.
Check operation of the hood.
If range hood does not operate:
Check that the circuit breaker is not tripped or the house
fuse blown.
Disconnect power supply. Check that wirin g is correct.
To get the most efcient use from your new range hood,
read the “Use and Care Information” section.
Keep your Installation Instructions and Use and Care Guide
close to range hood for easy reference.
16
Description of the hood & Controls
Blower and light controls
Lamphousings
GreaselterHandle
Greaselter
Duct covers
Louverholes(OnlyforRecirculatingversion)
1.
2.
3.
4.
5.
6.
17
Controls
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Note:Hoodretainslastspeedsettingwhenaspiration
switch is turned off.
Description of control panel
1. Light Button
PresslampbuttontoturnONthelightonHigh
Intensity(LampstatepreviouslyOFF).
PresslampbuttontoturnONthelightonLow
Intensity(LampstatepreviouslyON).
PresslampbuttontoturnOFFthelight(Lampstate
previouslyON).
2. Timer Button
Thedefaulttimersettingis10minutes,anditcanbe
adjusted between 60 minutes and 1 minute.
Afterpressingthetimerbutton,thecontrolenterstoa
timer setup mode, and user can adjust the timer
countdowntimewiththe“+”and“-”buttonswithin5
seconds.Thetimercanbeinitiatedimmediately
pressing the timer button, after setting the timer
duration or pressing the timer button twice (default 10
minutes setting).
If no action occurs within 5 seconds, the countdown
will start.
Duringthetimersetupthe“+”and“-”buttonsare
dedicated to the timer and no motor action will occur.
Oncethetimerisinitiated,itcanbecancelledby
pressing the timer button again.
3. Display
Shows the hood settings.
Thedisplaywillbelitatlowintensitywhenthehood
is not operating.
Pressing any key the display will light up at high
intensity.
Thedisplaywillbelitathighintensitywhenthehood
is operating.
If no key is pressed within a minute the display will
return to being lit at low intensity.
4. “-” Button. Speed Decrease / OFF
Thisbuttonisusedtodecreasethefanspeed,or
turnOFFthefan.
ThefanwillturnOFFifthe“-”buttonispressedand 
thehoodwasintherstspeed.
Ifthefanisatsecondspeedandthe“-”buttonis
pressed,thefanwillbesettorstspeed.
Ifthefanisatthirdspeedandthe“-”keyispressed,
the fan will be set to second speed.
Ifthefanisatfourthspeedandthe“-”buttonis
pressed, the fan will be set to third speed.
IfthefanisOFFandthe“-”buttonispressed,the
control backlight will light up.
5. “+” Button. Speed Increase / ON
Thisbuttonisusedtoincreasethefanspeed,orturn
ONthefan.
ThefanwillturnONifthe“+”buttonispressedand
thehoodwasOFF.
Ifthefanisatrstspeedandthe“+”buttonis
pressed, the fan will be set to second speed.
Ifthefanisatsecondspeedandthe“+”buttonis
pressed, the fan will be set to third speed.
Ifthefanisatthirdspeedandthe“+”buttonis
pressed, the fan will be set to fourth speed.
Ifthefanisatfourthspeedandthe“+”buttonis
pressed, a beep will sound.
Clock programming
Theclockcanbereprogrammedatanytimeexcept
during an active timed function.
Theclockcanbedisplayedinatwelvehourformatand
valid clock times are from 1:00 to 12:59.
Theclockcanbereprogrammedpressingthe“Timer”
button for 3 seconds, and after, the clock can be
adjustedwiththe“+”and“-”buttons.
Theusercanhaveminuteincrements/decrementsof1
minute,butiftheuserkeeppressingthe“+”/”-”buttons
formorethan1second,theincrements/decrementswill
be of 5 minutes.
During this option the control will round to the nearest 5
minutes.
Theusercannishonreprogrammingtheclockpressing
the“Timer”button.
After1minuteofnobuttonpressedthecontrolwill
accept the programmed clock time and will add one
minute to the set clock.
18
Greaseltersaturationalarm(Optional)
Afterthirtyfanfunctionalhours,thedisplaywillshow
“GreaseFilter”ifthefanisactive.
Whenthisiconisshowninthedisplay,thegreaselters
installed are required to be washed.
Toresetthegreaseltersaturationalarmtheusermust
pressthe“+”buttonfor5seconds,afterthisactionthe
icon“Greaselter”isnotdisplayed,andthehoodhas
the normal display operation.
Charcoalltersaturationalarm(Optional)
Afteronehundredandtwentyfunctionalhoursofthefan,
thedisplaywillshow“CharcoalFilter”ifthefanisactive.
Whenthisiconashesondisplay,thecharcoallters
installed are required to be replaced or reactivated.
Toresetthecharcoalltersaturationindicationtheuser
mustpressthe“-”buttonfor5seconds,afterthistime
theicon“Charcoallter”isnotdisplayedandthehood
has the normal display operation.
Audiblesignalactivationanddeactivation
Theaudiblesignalscanbeactivatedordeactivated
pressingthe“Light”buttonfor5seconds.
If the audible signal is activated, a tone must sound and
the“Snd”symbolmustappearonthedisplayfor3
seconds.
Iftheaudiblesignalisdeactivated,the“Snd”symbol
must appear on the display for 3 seconds and no tone
must sound.
Charcoallterinclusionandexclusion(Recirculating
accessories)
Thecharcoallterinclusionorexclusioncanbesetby
pressingthe“+”and“-”buttonsatthesametimefor5
seconds.
TheInclusionorexclusionofcharcoalltermustbe
selectedwhilethelampsandthemotorareOFF.
Whenthecharcoallterhasbeenexcluded,thecharcoal
lteralarmisdisabled.
Heatsensor
Thecontrolisequippedwithaheatsensorthatwillturn
on the blower at third speed if excessive heat occurs
(over 149° F or 65°C ) surrounding the control area.
IftheblowerisOFForifitisoperatingatrstspeed,the
blower will be set automatically to third speed, the
displayshowstheword“CArE“toindicatethatheat
sensor has detected an excessive heat.
During this state, the user may raise the blower speed to
fourth speed but can not decrease the speed.
When the temperature level on the hood drops to normal,
theblowerwilloperateinthesettingdenedbytheuser
before the alarm occured.
19
Cleaning
Do not spray cleaners directly to the control while
cleaningtheHood.Thecookerhoodshouldbecleaned
regularly (at least with the same frequency with which you
carryoutmaintenanceofthefatlters)internallyand
externally. Clean using the cloth dampened with neutral
liquiddetergent.Donotuseabrasiveproducts.DONOT
USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of
thecookerhoodandreplacementoftheltersmaycause
rerisks.
Therefore,werecommendoservingtheseinstructions.
Themanufacturerdeclinesallresponsibilityforanydamage
tothemotororanyredamagelinkedtoinappropriate
maintenance or failure to observe the above safety
recommendations.
Grease Filter
Trapscookinggreaseparticles.
Thismustbecleanedonceamonthusingnonaggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle. When
washedinadishwasher,thegreaseltermaydiscolour
slightly,butthisdoesnotaffectitslteringcapacity.
Toremovethegreaselter,pullthespringreleasehandle.
Replacing the light bulb
CAUTION
Before replacing the lamps, switch power off at service
panel and lock service panel disconnecting means to
prevent power from being switched on accidentally.
NOTE: Turn off the lights and fan. Allow the lights to
cool before handling. If new lights do not operate be
sure lights are inserted correctly before calling service.
Replace Lights
Remove the damaged light (twist counter clockwise)
and replace with a new 120 Volt, 50 Watt (maximum)
50° halogen light made for aGU10 base, suitable
use in open luminarie.
Maintenance
ATTENTION!Beforeperforminganymaintenanceoperation,isolatethehoodfromtheelectricalsupplybyswitchingoffatthe
connector and removing the connector fuse.
Oriftheappliancehasbeenconnectedthroughaplugandsocket,thentheplugmustberemovedfromthesocket.
20
Charcoal Filter
If the model is not vented to the outside, the air will be
recirculatedthroughdisposablecharcoalltersthathelp
remove smoke and odors.
Thecharcoalltersareclippedonthemotorhousingframe.
NOTE: Charcoalltersarenotincludedwiththehood.
Theymustbeorderedfromyoursupplier.
Ordertheneededkitspecifyingyourhoodmodelandwidth
size.
Cleaning/replacing the charcoal lter
Unlikeothercharcoallters,theLONGLIFEcharcoallter
can be cleaned and reactivated.
Withnormalusetheltershouldbecleanedeverysecond
month (when using the hood 2.5 hours per day,on average).
Thebestwaytocleanthelterisinthedishwasher.Use
normal detergent and choose the highest temperature (65º
C or 149° F).
Washthelterseparatelysothatnofoodpartsgetsstuck
onthelterandlatercausesbadodours.
Toreactivatethecharcoal,theltershouldbedriedinan
oven for 10 minutes with a maximum temperature of 100º C
or 212° F.
Afterapproximatelyoneyearofuse,thecharcoallter
should be replaced with a new one, as the odour reduction
capacity will be reduced.
Motor
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

ELICA ESL636S3 Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation