Chamberlain 8360 Manuel utilisateur

Catégorie
Porte de garage
Taper
Manuel utilisateur

Ce manuel convient également à

PREMIUM Series Garage Door Opener
MODELS 8355 • 8360 • 8365-267
USER’S GUIDE
Please read this guide and the enclosed safety materials carefully!
The door WILL NOT CLOSE unless the Protector System
®
is connected and properly aligned.
Periodic checks of the garage door opener are required to ensure
safe operation.
This garage door opener is ONLY compatible with MyQ
®
and Security+ 2.0
®
accessories.
DO NOT enable the Timer-to-Close feature if you are installing the
garage door opener on a one-piece door. The Timer-to-Close is to
be used ONLY with sectional doors.
Attach enclosed warning labels to the location indicated on label.
FOR RESIDENTIAL USE ONLY
LiftMaster
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
Register your garage door opener to receive
updates and offers from LiftMaster
Take a photo of the camera icon
including the points ( ).
Send it in by texting
the photo to 71403 (US)
or visit www.liftmaster.photo (Global)
2
Contents
Important Safety Instructions ............................3-4
Operation...................................................... 5
Using the Door Control .................................. 6
Programming-Door Control Panel ..................... 7
Programming - Remote Controls....................... 8
To Erase the Memory .................................... 8
To Open the Door Manually ............................. 9
Battery Backup* .......................................... 9
Adjustment ...................................................10
Program the Travel ......................................11
Test the Safety Reversal System ......................12
Test the Protector System
®
............................12
Maintenance .................................................13
Troubleshooting .........................................14-15
Repair Parts .................................................16
Warranty .....................................................17
Registration..................................................18
Safety Symbol and Signal Word
Review
This garage door opener has been designed and tested
to offer safe service provided it is installed, operated,
maintained and tested in strict accordance with the
instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal
Words on the following pages, they will alert you to
the possibility of serious injury or death if you do not
comply with the warnings that accompany them. The
hazard may come from something mechanical or from
electric shock. Read the warnings carefully.
Mechanical
Electrical
When you see this Signal Word on the following pages, it
will alert you to the possibility of damage to your garage
door and/or the garage door opener if you do not comply
with the cautionary statements that accompany it. Read
them carefully.
Serial Number:
Date of Purchase:
Write down the following information
for future reference:
The images throughout this manual are for reference and your product may look different.
CONTACT INFORMATION
Leave this Users Guide with the homeowner.
.
*If applicable.
3
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
WARNING
WARNING
WARNING
WARNING
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
2. Install garage door opener ONLY on properly
balanced and lubricated garage door. An
improperly balanced door may NOT reverse when
required and could result in SEVERE INJURY or
DEATH.
3. ALL repairs to cables, spring assemblies and
other hardware MUST be made by a trained door
systems technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes
connected to garage door BEFORE installing
opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or
more above fl oor.
6. Mount the emergency release within reach, but at
least 6 feet (1.83 m) above the fl oor and avoiding
contact with vehicles to avoid accidental release.
7. NEVER connect garage door opener to power
source until instructed to do so.
8. NEVER wear watches, rings or loose clothing
while installing or servicing opener. They could
be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to
garage door control.
11. Place manual release/safety reverse test label in
plain view on inside of garage door.
12. Upon completion of installation, test safety
reversal system. Door MUST reverse on contact
with a 1-1/2" (3.8 cm) high object (or a 2x4 laid
at) on the fl oor.
13. To avoid SERIOUS PERSONAL INJURY or
DEATH from electrocution, disconnect ALL
electric and battery power BEFORE performing
ANY service or maintenance.
14. DO NOT enable the Timer-to-Close functionality
if operating either one-piece or swinging garage
doors. To be enabled ONLY when operating a
sectional door.
15.
SAVE THESE
INSTRUCTIONS.
Important Safety Instructions
NOTE: For complete installation instructions visit LiftMaster.com to print the entire owner’s manual.
4
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
WARNING
WARNING
WARNING
WARNING
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of
children. NEVER permit children to operate or
play with garage door control push buttons or
remote controls.
3. ONLY activate garage door when it can be seen
clearly, it is properly adjusted, and there are no
obstructions to door travel.
4. ALWAYS keep garage door in sight and away
from people and objects until completely closed.
NO ONE SHOULD CROSS THE PATH OF THE
MOVING DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED,
PARTIALLY OPENED DOOR.
6. If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Use caution when using this release
with the door open. Weak or broken springs or
unbalanced door could result in an open door
falling rapidly and/or unexpectedly and increasing
the risk of SEVERE INJURY or DEATH.
7. NEVER use emergency release handle unless
garage doorway is clear of persons and
obstructions.
8. NEVER use handle to pull garage door open or
closed. If rope knot becomes untied, you could
fall.
9. After ANY adjustments are made, the safety
reversal system MUST be tested.
10. Safety reversal system MUST be tested every
month. Garage door MUST reverse on contact
with 1-1/2" high (3.8 cm) object (or a 2x4 laid
at) on the fl oor. Failure to adjust the garage
door opener properly increases the risk of
SEVERE INJURY or DEATH.
11. ALWAYS KEEP GARAGE DOOR PROPERLY
BALANCED. An improperly balanced door may
NOT reverse when required and could result in
SEVERE INJURY or DEATH.
12. ALL repairs to cables, spring assemblies
and other hardware, ALL of which are under
EXTREME tension, MUST be made by a trained
door systems technician.
13. ALWAYS disconnect electric power to garage
door opener BEFORE making ANY repairs or
removing covers.
14. This operator system is equipped with an
unattended operation feature. The door could
move unexpectedly. NO ONE SHOULD CROSS
THE PATH OF THE MOVING DOOR.
15. DO NOT enable the Timer-to-Close functionality
if operating either one-piece or swinging garage
doors. To be enabled ONLY when operating a
sectional door.
16.
SAVE THESE
INSTRUCTIONS.
5
Operation
Your garage door opener is equipped with features to
provide you with greater control over your garage door
operation. Accessories provided with your garage door
opener will vary depending on the garage door opener
model purchased.
ALERT2CLOSE
The Alert2Close feature provides a visual and an audible
alert that an unattended door is closing.
TIMER-TO-CLOSE (TTC)
The Timer-to-Close feature automatically closes the door
after a specifi ed time period that can be adjusted using
a TTC enabled door control (Models 881LM or 880LM).
Prior to and during the door closing the garage door
opener lights will fl ash and the garage door opener will
beep.
MyQ
®
MyQ
®
technology uses a 900MHz signal to provide two-
way communication between the garage door opener and
MyQ
®
enabled accessories. Your garage door opener is
compatible with up to 16 MyQ
®
accessories.
REMOTE CONTROLS AND DOOR CONTROLS
(SECURITY+ 2.0
®
)
Your garage door opener has already been programmed
at the factory to operate with your remote control, which
changes with each use, randomly accessing over 100
billion new codes. Compatible with MyQ
®
and
Security+ 2.0
®
.
NOTE: Older LiftMaster remote controls, door controls,
and third party products are not compatible.
Accessories
(Security+ 2.0
®
)
MEMORY CAPACITY
Remote Controls Up to 24
Door Controls Up to 2 Smart Control Panels or 4
of any other Security+ 2.0
®
door
controls
Keyless Entries Up to 2
THE PROTECTOR SYSTEM
®
(SAFETY REVERSING
SENSORS)
When properly connected and aligned, the safety
reversing sensors will detect an obstruction in the path
of the infrared beam. If an obstruction breaks the infrared
beam while the door is closing, the door will stop and
reverse to full open position, and the opener lights will
ash 10 times. If the door is fully open, and the safety
reversing sensors are not installed, or are misaligned,
the door will not close from a remote control. However,
you can close the door if you hold the button on the door
control or keyless entry until the door is fully closed. The
safety reversing sensors do not affect the opening cycle.
ENERGY CONSERVATION
For energy effi ciency the garage door opener will enter
sleep mode when the door is fully closed. The sleep mode
shuts the garage door opener down until activated. The
sleep mode is sequenced with the garage door opener
light bulb; as the light bulb turns off the sensor LEDs will
turn off and whenever the garage door opener lights turn
on the sensor LEDs will light.
LIGHTS
The garage door opener light bulbs will turn on when
the opener is initially plugged in; power is restored after
interruption, or when the garage door opener is activated.
The lights will turn off automatically after 4-1/2 minutes.
An incandescent A19 light bulb (100 watt maximum) or
for maximum energy effi ciency a 26W (100W equivalent)
compact fl uorescent light (CFL) bulb may be used.
Light Feature
The garage door opener is equipped with an added
feature; the lights will turn on when someone enters
through the open garage door and the safety reversing
sensor infrared beam is broken. For added control over
the light bulbs on your garage door opener, see page 7.
USING YOUR GARAGE DOOR OPENER
The garage door opener can be activated through a wall-
mounted door control, remote control, wireless keyless
entry or MyQ
®
accessory. When the door is closed and
the garage door opener is activated the door will open.
If the door senses an obstruction or is interrupted while
opening the door will stop. When the door is in any
position other than closed and the garage door opener is
activated the door will close. If the garage door opener
senses an obstruction while closing, the door will reverse.
If the obstruction interrupts the sensor beam the garage
door opener lights will blink 10 times. However, you can
close the door if you hold the button on the door control
or keyless entry until the door is fully closed. The safety
reversing sensors do not affect the opening cycle. The
safety reversing sensor must be connected and aligned
correctly before the garage door opener will move in the
down direction.
6
Operation
Using the Door Control
PUSH BAR
Press the push bar to open and close the door.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener
lights on or off. When the lights are turned on they will
stay on until the LIGHT button is pressed again, or until
the garage door opener is activated. Once the garage
door opener is activated the lights will turn off after the
specifi ed period of time (the factory setting is 4-1/2
minutes). The LIGHT button will not control the lights
when the door is in motion. The duration of the light
timing can be adjusted using the door control, see
page 7.
The following features are accessible by lifting the
push bar:
LEARN A DEVICE
Any compatible remote controls, wireless keyless entry,
or MyQ
®
accessories can be programmed to the garage
door opener by pressing the Learn button.
LOCK
The LOCK feature is designed to prevent activation of
the garage door opener from remote controls while still
allowing activation from the door control and keyless
entry. This feature is useful for added peace of mind
when the home is empty (i.e. vacation).
AUTOMATIC LIGHT
Motion Sensor (Motion-Detecting Control Panel)
Factory default is set to on. This feature automatically
turns on the garage door opener lights when motion
is sensed. The lights will come on for the set period of
time, then shut off. If using the garage door opener light
as a work light disable the motion sensor, otherwise
the light will turn off automatically if you are beyond the
range of the sensor.
Light Feature
The lights will turn on when someone enters through
the open garage door and the safety reversing sensor
infrared beam is broken.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the
garage door opener system stays in good working
condition. When the garage door opener needs to be
serviced (approximately 4500 garage door opener
cycles) the command (yellow) and service (red) LEDs
will begin to alternately fl ash back and forth. The factory
setting for the MAS feature is off and can be activated
at time of installation. Contact your installing dealer for
service.
Push Bar
Light Button
MOTION-DETECTING CONTROL PANEL
The control panel will vary depending on the garage door opener
model purchased.
MULTI-FUNCTION CONTROL PANEL
Service LED
LEARN Button
LOCK Button
Light Button
Service LED
Push Bar
LEARN Button
LOCK Button
Command LED
SYNCHRONIZE THE DOOR CONTROL
To synchronize the door control to the garage door
opener, press the push bar until the garage door
opener activates (it may take up to 3 presses). Test the
door control by pressing the push bar, each press of
the push bar will activate the garage door opener.
7
Service
LED
LEARN
Button
LEARN
Button
LOCK
Button
LOCK
Button
Motion
Sensor
Operation
Features
Lock NOTE: Your remote controls will NOT work when LOCK mode is active however your keyless
entry will still allow access to your garage.
Activate: Press and hold the LOCK button for 2 seconds. The command LED will fl ash as long
as the lock feature is activated and your handheld remote control will not operate your door at
this time.
Deactivate: Press and hold the LOCK button again for 2 seconds. The command LED will stop
ashing and normal operation will resume.
Light To change the amount of time the garage door opener lights will stay on:
Press and hold the LOCK button until the garage door opener lights fl ash.* The time interval is
indicated by the number of fl ashes.
To cycle through the time intervals repeat the step above.
Deactivate: Press and hold the LIGHT button until the garage door opener lights turn on, then
off again.*
Activate: Start with the garage door opener lights on. Press and hold the LIGHT button until the
garage door opener lights turn off, then on again.*
* Approximately 10 seconds
Motion Sensor
(Motion-Detecting
Control Panel)
Activate/Deactivate: Slide the motion sensor switch ON or OFF.
To Program a
Remote Control
or Keyless Entry
1. Press the LEARN button on the door control to enter Programming Mode.
2. Press the LEARN button again, the LED will fl ash once.
3. Remote Control: Press the button on the remote control that you wish to operate your garage
door.
Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) of your choice on the
keyless entry keypad. Then press the ENTER button.
The garage door opener lights will fl ash (or two clicks will be heard) when the code has been
programmed. If programming is unsuccessful, repeat steps 1-3 or program the remote using
the learn button on the garage door opener.
Maintenance
Alert System
(MAS)
Activate/Deactivate
Press and hold the LEARN button. Then press the LIGHT button. The service LED will fl ash the
status; Active is 2 fl ashes and deactivated is 3 fl ashes.
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH 1234
TIME THE GARAGE DOOR OPENER LIGHT STAYS ON 1 ½
Minutes
2 ½
Minutes
3 ½
Minutes
4 ½
Minutes
Motion Sensor
Switch
Command
LED
Service
LED
LIGHT
Button
LIGHT
Button
Command LED
MULTI-FUNCTION CONTROL PANELMOTION-DETECTING CONTROL PANEL
Programming - Door Control Panel
8
Operation
1 Press and release the Learn button on the garage
door opener. The Learn indicator light will glow
steadily for 30 seconds.
PROGRAM A REMOTE USING THE LEARN BUTTON ON THE GARAGE DOOR OPENER
When replacing the light lens cover, ensure the antenna wires are hanging straight down.
Learn
Indicator
Light
Yellow
Learn
Button
Your garage door opener has been programmed at the factory to operate with your remote control. Older LiftMaster
remote controls are NOT compatible. Programming can be done through the door control or the Learn button on the
garage door opener. To program additional remote controls refer to the instructions provided with the additional remote
controls or visit LiftMaster.com. If your vehicle is equipped with a Homelink
®
, you may require an external adapter
depending on the make, model, and year of your vehicle. Visit www.homelink.com for additional information.
ERASE ALL REMOTE CONTROLS AND KEYLESS ENTRIES
1 Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds). All
remote control and keyless entry codes are now erased.
Reprogram any accessory you wish to use.
ERASE ALL DEVICES (Including MyQ
®
enabled accessories)
1 Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds).
2 Immediately press and hold the learn button again until the learn LED goes out. All codes are now erased.
Reprogram any accessory you wish to use.
Programming - Remote Controls
To Erase the Memory
2 Within 30 seconds,
press and hold
the button on the
remote control.
3 Release the button when the
garage door opener light blinks.
It has learned the code. If light
bulbs are not installed, two clicks
will be heard.
9
DISCONNECT THE TROLLEY
1 The door should be fully
closed if possible.
2 Pull down on the emergency
release handle.
RECONNECT THE TROLLEY
The lockout feature prevents
the trolley from reconnecting
automatically.
1 Pull the emergency release
handle down and back
(toward the opener). The
door can then be raised and
lowered manually as often as
necessary.
2 To disengage the lockout feature, pull the handle
straight down.
The trolley will reconnect on the next UP or DOWN
operation, either manually or by using the door control or
remote control.
Operation
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
NEVER use emergency release handle unless
garage doorway is clear of persons and
obstructions.
NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
To Open the Door Manually
Battery Backup (If applicable)
The battery backup system allows access in and out of your garage, even when the power is out. When the garage door
opener is operating on battery power, the garage door opener will run slower, the light will not function, the Battery
Status LED will glow solid orange, and a beep will sound approximately every 2 seconds.
The battery charges when the garage door opener is plugged into a 110Vac electrical outlet that has power and
requires 24 hours to fully charge. A fully charged battery supplies 12Vdc to the garage door opener for one to two
days of normal operation during an electrical power outage. After the electrical power has been restored, the battery
will recharge within 24 hours. The battery will last approximately 1 to 2 years with normal usage. Instructions for
replacement are provided with the battery. To obtain maximum battery life and prevent damage, disconnect the battery
when the garage door opener is unplugged for an extended period of time.
NOTE: When the garage door opener is in battery backup mode the garage door opener lights, Timer-to-Close, and
Remote Close features are unavailable.
BATTERY STATUS LED
GREEN LED:
All systems are normal.
A solid green LED light indicates the battery is fully
charged.
A fl ashing green LED indicates the battery is being
charged.
ORANGE LED:
The garage door opener has lost power and is in battery
backup mode.
A solid orange LED with beep, sounding
approximately every 2 seconds, indicates the garage
door opener is operating on battery power.
A fl ashing orange LED with beep, sounding every 30
seconds, indicates the battery is low.
RED LED:
The garage door opener’s 12V battery needs to be
replaced.
A solid red LED with beep, sounding every 30
seconds, indicates the garage door opener needs
servicing. Please call for replacement battery to allow
your system to operate during a power outage.
NOTE: The Battery Status LED is most visible with the
garage door opener light off. Battery does not have to be
fully charged to operate the garage door opener.
Battery Status LED
10
Adjustment
Introduction
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
Incorrect adjustment of garage door travel limits
will interfere with proper operation of safety
reversal system.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" (3.8 cm) high object
(or 2x4 laid fl at) on fl oor.
To prevent damage to vehicles, be sure fully open
door provides adequate clearance.
Your garage door opener is designed with electronic
controls to make setup and adjustments easy. The
adjustments allow you to program where the door will
stop in the open (UP) and close (DOWN) position. The
electronic controls sense the amount of force required to
open and close the door.
NOTE: If anything interferes with the door’s upward
travel it will stop. If anything interferes with the door’s
downward travel, it will reverse.
To watch a short instructional video on programming
your new garage door opener use your smartphone to
read the QR Code below:
UP (Open) DOWN (Close)
PROGRAMMING BUTTONS
The programming buttons are located on the left side panel of the garage door opener and are used to program the travel.
UP Button
Adjustment
Button
DOWN Button
PROGRAMMING BUTTONS
11
Program the Travel
1
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY
INJURED or KILLED by a closing garage door.
Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with
1-1/2" (3.8 cm) high object (or 2x4 laid fl at) on fl oor.
Adjustment
1.1 Press and hold the
Adjustment Button
until the UP Button
begins to fl ash and/or
a beep is heard.
1.2 Press and hold the UP Button until the door is
in the desired UP position.
NOTE: The UP and DOWN Buttons can be used to
move the door up and down as needed.
1.5 Once the door is in the
desired DOWN position
press and release the
Adjustment Button. The
garage door opener lights
will fl ash twice and the UP
Button will begin to fl ash.
1.6 Press and release the UP Button. When the door
travels to the programmed UP position, the
DOWN Button will begin to fl ash.
1.7 Press and release the DOWN Button. The door
will travel to the programmed DOWN position.
Programming is complete.
* If the garage door opener lights are fl ashing 5
times during the steps for Program the Travel, the
programming has timed out. If the garage door
opener lights are fl ashing 10 times during the steps
for Program the Travel, the safety reversing sensors
are misaligned or obstructed. When the sensors are
aligned and unobstructed, cycle the door through a
complete up and down cycle using the remote control
or the UP and DOWN buttons. Programming is
complete. If you are unable to operate the door up and
down, repeat the steps for Program the Travel.
1.4 Press and hold the DOWN Button until the door
is in the desired DOWN position.
NOTE: The UP and DOWN Buttons can be used to
move the door up and down as needed.
1.3 Once the door is in the
desired UP position press
and release the Adjustment
Button. The garage door
opener lights will fl ash
twice and the DOWN
Button will begin to fl ash.
12
2.1 With the door fully open, place a 1-1/2 inch
(3.8 cm) board (or a 2x4 laid fl at) on the fl oor,
centered under the garage door.
Test the Safety Reversal System
2.2 Press the remote control push button to close
the door. The door MUST reverse when it makes
contact with the board.
If the door stops and does not reverse on the obstruction,
increase the down travel (see Adjustment Step 1).
Repeat the test. When the door reverses upon contact
with the 1-1/2 inch board, remove the board and open/
close the door 3 or 4 times to test the adjustment.
If the test continues to fail, call a trained door systems
technician.
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
Safety reversal system MUST be tested every
month.
After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid
at) on the fl oor.
2
Test the Protector System
®
3.1 Open the door. Place the garage door opener
carton in the path of the door.
The garage door opener will not close from a remote
control if the LED in either safety reversing sensor is off
(alerting you to the fact that the sensor is misaligned or
obstructed).
If the garage door opener closes the door when the
safety reversing sensor is obstructed (and the sensors
are no more than 6 inches [15 cm] above the fl oor), call
for a trained door systems technician.
Without a properly installed safety reversing sensor,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
3.2 Press the remote control push button to close
the door. The door will not move more than
an inch (2.5 cm), and the garage door opener
lights will fl ash 10 times.
3
Adjustment
13
To prevent possible SERIOUS INJURY or DEATH:
NEVER allow small children near batteries.
If battery is swallowed, immediately notify doctor.
To reduce risk of fi re, explosion or chemical burn:
Replace ONLY with 3V CR2032 coin batteries.
DO NOT recharge, disassemble, heat above 212°F
(100°C) or incinerate.
The Remote Control Battery
Maintenance
EVERY MONTH
Manually operate door. If it is unbalanced or binding,
call a trained door systems technician.
Check to be sure door opens and closes fully. Adjust if
necessary, page 11.
Test the safety reversal system. Adjust if necessary,
page 12.
EVERY YEAR
Oil door rollers, bearings and hinges. The garage door
opener does not require additional lubrication. Do not
grease the door tracks.
(If applicable) Test the battery backup and consider
replacing the battery to ensure the garage door opener
will operate during an electrical power outage.
Testing the Battery Backup:
1. Unplug the garage door opener. The battery
status LED will either glow solid orange indicating
opener is operating on battery power or will fl ash
indicating low battery power.
2. Open and close the door using the remote control
or door control.
NOTE: The garage door opener may run slower
if the battery is not fully charged. The battery will
take 24 hours to fully charge.
3. Plug in the garage door opener. Verify the battery
status LED is fl ashing green, indicating the
battery is charging.
EVERY TWO TO THREE YEARS
Use a rag to wipe away the existing grease from the
garage door opener rail. Reapply a small layer of white
lithium grease to the top and underside of the rail
surface where the trolley slides.
The Lithium batteries should produce power for up to 5
years. If the battery is low, the remote control’s LED will
not fl ash when the button is pressed. To replace battery,
pry open the case fi rst in the middle (1), then at each
side (2 and 3) with the visor clip. Insert battery positive
side up.
Replace the batteries with only 3V CR2032 coin cell
batteries. Dispose of old batteries properly.
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifi cations of this transceiver are prohibited. THERE ARE NO USER
SERVICEABLE PARTS. Any changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
AVIS : Les règles de la FCC et/ou d’Industrie Canada (IC) interdisent tout ajustement ou toute modifi cation de ce récepteur. IL N’EXISTE AUCUNE PIÈCE
SUSCEPTIBLE D’ÊTRE ENTRETENUE PAR L’UTILISATEUR. Tout changement ou toute modifi cation non expressément approuvé par la partie responsable de
la conformité peut avoir pour résultat d’annuler l’autorité de l’utilisateur de faire fonctionner l’équipement.
Cet appareil est conforme aux dispositions de la partie 15 du règlement de la FCC et de la norme IC RSS-210. Son utilisation est assujettie aux deux conditions
suivantes : (1) ce dispositif ne peut causer des interférences nuisibles, et (2) ce dispositif doit accepter toute interférence reçue, y compris une interférence
pouvant causer un fonctionnement non souhaité.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
1
2
3
14
Troubleshooting
DIAGNOSTIC CODE SYMPTOM SOLUTION
Up arrow
Flash(es)
Down arrow
Flash(es)
11
The garage door opener
will not close and the
light bulbs fl ash.
Safety sensors are not installed, connected, or wires
may be cut. Inspect sensor wires for a disconnected
or cut wire.
12
The garage door opener
will not close and the
light bulbs fl ash.
There is a short or reversed wire for the safety
sensors. Inspect safety sensor wire at all staple and
connection points, replace wire or correct as needed.
13
The door control will not
function.
The wires for the door control are shorted or the door
control is faulty. Inspect door control wires at all
staple and connection points, replace wire or correct
as needed.
14
The garage door opener
will not close and the
light bulbs fl ash.
Safety sensors are misaligned or were momentarily
obstructed. Realign both sensors to ensure both LEDs
are steady and not fl ickering. Make sure nothing is
hanging or mounted on the door that would interrupt
the sensor’s path while closing.
15
Door moves 6-8" (15-20
cm) stops or reverses.
Manually open and close the door. Check for binding
or obstructions, such as a broken spring or door lock,
correct as needed. Check wiring connections at travel
module and at the logic board. Replace travel module
if necessary.
No movement, only a
single click.
Manually open and close the door. Check for binding
or obstructions, such as a broken spring or door lock,
correct as needed. Replace logic board if necessary.
Opener hums for 1-2
seconds no movement.
Manually open and close the door. Check for binding
or obstructions, such as a broken spring or door lock,
correct as needed. Replace motor if necessary.
16
Door coasts after it has
come to a complete stop.
Program travel to coasting position or have door
balanced by a trained door systems technician.
2 1-5 No movement, or sound. Replace logic board.
32
Unable to set the travel
or retain position.
Check travel module for proper assembly, replace if
necessary.
33
The battery status LED*
is constantly fl ashing
green.
Battery backup* charging circuit error, replace the
logic board.
*If applicable.
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage
door opener will fl ash the diagnostic codes.
15
Diagnostic Chart
My garage door opener beeps:
The garage door opener can beep for several reasons:
Garage door opener has been activated through a device
or feature such as Timer-to-Close, garage door monitor
or LiftMaster Internet Gateway, see page 5.
Operating on battery power or the 12Vdc battery needs
to be replaced (if applicable), see pages 9 and 13.
My remote control will not activate the garage door:
Verify the lock feature is not activated on the door
control.
• Reprogram the remote control.
If the remote control will still not activate the door check
the diagnostic codes to ensure the garage door opener
is working properly.
My door will not close and the light bulbs blink on my
motor unit:
The safety reversing sensor must be connected and
aligned correctly before the garage door opener will move
in the down direction.
Verify the safety sensors are properly installed, aligned
and free of any obstructions.
My garage door opener light(s) will not turn off when the
door is open:
The garage door opener is equipped with a feature that
turns the light on when the safety reversing sensors have
been obstructed or when the motion sensor on the door
control detects movement in the garage. These features
can be disabled using the door control, see page 7.
My neighbor’s remote control opens my garage door:
Erase the memory from your garage door opener and
reprogram the remote control(s).
My vehicle’s Homelink
®
is not programming to my
garage door opener:
Depending on the make, model, and year of your vehicle
an external adapter may be required. Visit
www.homelink.com for additional information.
Troubleshooting
DIAGNOSTIC CODE SYMPTOM SOLUTION
Up arrow
Flash(es)
Down arrow
Flash(es)
4 1-4
Door is moving stops or
reverses.
Manually open and close the door. Check for
binding or obstructions, such as a broken spring
or door lock, correct as needed. If the door is
binding or sticking contact a trained door systems
technician. If door is not binding or sticking attempt
to reprogram travel (refer to page 11).
45
Opener runs approximately
6-8" (15-20 cm), stops and
reverses.
Communication error to travel module. Check
travel module connections, replace travel module if
necessary.
46
The garage door opener
will not close and the light
bulbs fl ash.
Safety sensors are misaligned or were momentarily
obstructed. Realign both sensors to ensure both
LEDs are steady and not fl ickering. Make sure
nothing is hanging or mounted on the door that
would interrupt the sensor’s path while closing.
16
Repair Parts
7
5
6
3A
4A
3B
4B
1
1
2
NOTE: For additional parts not shown, visit
LiftMaster.com to download or print the full owner’s
manual. The images throughout this manual are for
reference and your product may look different.
DESCRIPTION
PART
NUMBER
1 Light Lens - Models 8360 and 8355 41A7562
Light Lens - Model 8365-267 108D79
2 Receiver Logic Board - Model 8360 45DCT
Receiver Logic Board - Models 8355 and
8365-267 45ACT
3A Travel Module - Model 8360
41A7114-7
3B Travel Module - Models 8355 and 8365-267
041D7742-7
4A Motor w/Travel Module - Model 8360
41D1739-1
4B Motor w/Travel Module - Model 8355
041A7442
4C Motor w/Travel Module - Model 8365-267
041D7440
5 3V CR2032 Lithium Battery (Remote
Control) 10A20
6 Backup Battery (if applicable)
485LM
7 Safety Sensor Kit with receiving and
sending sensors with 3 feet (.9 m)
2-conductor wire 41A5034
4C
17
Warranty
LIFTMASTER
®
ONE YEAR LIMITED WARRANTY
LIFETIME MOTOR AND BELT* LIMITED WARRANTY
ONE YEAR LIMITED WARRANTY FOR THE BATTERY BACKUP SYSTEM*
LiftMaster (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product
is originally installed, that it is free from defects in materials and/or workmanship for a period of one year from
the date of purchase, except that the motor and belt* are warranted to be free from defects in materials and/or
workmanship for the lifetime of the product while you own your residence, and the Battery Backup System* is
warranted to be free from defects in materials and/or workmanship for a period of one year from the date of
purchase. The proper operation of this product is dependent on your compliance with the instructions regarding
installation, operation, and maintenance and testing. Failure to comply strictly with those instructions will void
this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty,
call 1-800-528-9131, toll free, before dismantling this product. You will be advised of disassembly and shipping
instructions when you call. Then send the product or component, pre-paid and insured, as directed to our service
center for warranty repair. Please include a brief description of the problem and a dated proof-of-purchase
receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon
receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced
(at Seller’s sole option) at no cost to you and returned pre- paid. Defective parts will be repaired or replaced with
new or factory-rebuilt parts at Seller’s sole option. [You are responsible for any costs incurred in removing and/
or reinstalling the product or any component.]
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN
DURATION TO THE APPLICABLE LIMITED WARRANTY PERIOD SET FORTH ABOVE FOR THE RELATED
COMPONENT(S), AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some states
do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER
INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO
PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS
TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT
OF CONSUMABLE ITEMS (E.G., BATTERIES IN REMOTE CONTROL TRANSMITTERS AND LIGHT BULBS), OR
UNITS INSTALLED FOR NON-RESIDENTIAL USE. THIS LIMITED WARRANTY DOES NOT COVER ANY
PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT
NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED
WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. UNDER NO
CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES
ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S
LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED
THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the
above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you
may also have other rights, which vary from state to state.
*If applicable.
114A4414G
© 2016, LiftMaster
All Rights Reserved
Registration
OR register online at
www.prodresgister.com/liftmaster
Register your garage door opener to receive
updates and offers from LiftMaster
Take a photo of the camera icon
including the points (
).
Send it in by texting
the photo to 71403 (US)
or visit www.liftmaster.photo (Global)
Ouvre-porte de garage de série PREMIUM
MODÈLES 8355 • 8360 • 8365-267
GUIDE DE L’UTILISATEUR
Veuillez lire attentivement ce guide de même que la documentation de sécurité
incluse!
La porte NE SE FERMERA PAS si le Système Protector
®
n’est pas branché et
réglé correctement.
Des vérifications périodiques de l’ouvre-porte de garage sont requises pour
garantir un fonctionnement sécuritaire du dispositif.
Cet ouvre-porte de garage est compatible UNIQUEMENT avec les accessoires
MyQ
®
et Security+ 2.0
®
.
N’activez PAS la fonction de minuterie de fermeture si vous installez l’ouvre-
porte de garage sur une porte rigide. La minuterie de fermeture doit être utilisée
UNIQUEMENT sur les portes articulées.
Apposer les étiquettes d’avertissement incluses à l’endroit indiqué sur l’étiquette.
POUR RÉSIDENCES SEULEMENT
LiftMaster
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
Enregistrez votre ouvre-porte de garage pour recevoir des
mises à jour et des offres de LiftMaster
Prenez une photo de l’icône d’appareil-photo,
y compris les points ( ).
Envoyez la photo par message
textuel à 71403 (É.-U.)
ou allez à www.liftmaster.photo (mondial)
2
L’INFORMATION DE CONTACT
Laissez ce Guide de l’utilisateur au propriétaire.
Matières
Importantes Consignes de Sécurité .....................3-4
Fonctionnement .............................................. 5
Utilisation de la commande de porte ................... 6
Programmation - Panneau de commande
de portende ................................................. 7
Programmation - Télécommande ....................... 8
Pour effacer tous le codes ............................... 8
Ouverture manuelle de la porte ......................... 9
Pile de secours* ........................................... 9
Réglage ......................................................10
Programmation des courses ............................ 11
Essai du système d’inversion
de sécurité .................................................12
Essai du Protector System
®
............................. 12
Entretien......................................................13
Dépannage ...............................................14-15
Pièces de Rechange ........................................16
Garantie ...................................................... 17
Enregistrement ..............................................18
.
*S’il y a lieu.
Numéro de série :
Date d’achat :
Veuillez noter les renseignements
suivants pour référence ultérieure :
Revue des symboles de sécurité et
des mots de signalement
Cet ouvre-porte de garage a été conçu et mis à l’essai
dans le but d’offrir un service sûr à condition qu’il soit
installé, utilisé, entretenu et mis à l’essai en stricte
conformité avec les instructions et les avertissements
contenus dans le présent manuel.
Lorsque vous verrez ces symboles de sécurité et ces
mots de signalement sur les pages suivantes, ils vous
aviseront de la possibilité de blessures graves ou de
mort si vous ne vous conformez pas aux avertissements
qui les accompagnent. Le danger peut être de source
mécanique ou provenir d’un choc électrique. Lisez
attentivement les avertissements.
Mécanique
Électrique
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
ATTENTIONATTENTION
AVERTISSEMENT
AVERTISSEMENT
AVERTISSEMENT
Lorsque vous verrez ce mot de signalement sur les
pages suivantes, il vous avisera de la possibilité de
dommages à votre porte de garage ou ouvre-porte de
garage, ou les deux, si vous ne vous conformez pas aux
énoncés de mise en garde qui l’accompagnent. Lisez-les
attentivement.
Les illustrations de ce mode d’emploi ne servent qu’à titre de référence. Votre appareil peut avoir un aspect différent.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Chamberlain 8360 Manuel utilisateur

Catégorie
Porte de garage
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues