EXIT300
EXIT
OPERATING INSTRUCTION
“EXIT 300” (“EXIT”) button with indicator is intended for electromagnetic lock release.
“EXIT 300” has advanced endurance comparing to “EXIT” button and can be exposed to intensive operation.
Normally closed contact guarantees lock release in case of controlling device (doorstation, keys-controller etc.)
failure.
SPECIFICATIONS
Strikes, “EXIT 300”, no less then 300000
Strikes, “EXIT”, no less then 40000
Contacts: NO, NC
Max. switchable current, À, 1
Max. operating voltage, VDC 24
Dimensions, mm 75õ47õ22
Weight, kg 0.1
Operating conditions:
- ambient temperature range: -10°C... +50°C
- relative humidity of air: 93% at 25°C.
PARTS LIST
Button (“EXIT300”/ “EXIT”) 1
Mounting kit 1
Operating instruction 1
SAFETY INSTRUCTIONS
The button does not contain voltage above 24VDC.
Do not expose the device to voltage above 24VDC.
INSTALLATION
Before mounting, examine carefully the operating instruction for operation order and wiring diagrams (Figures 1-2).
Fix the button inside the building on the door or near it.
The button can be fixed either via its front or back panel.
Use screws M4 (supplied) to mount the button via its front panel. Drive the gags into mounting holes.
Use screws M5 to mount the button via its back panel.
Abbreviations used:
W- G- white and green wires of NC contact
B - R - black and red wires of NO contact
Bl - blue wire of indication circuit
ATTENTION! Using the button is not allowed if the lock is not provided with degaussing circuitry.