Stonco LED General Purpose Garage and Canopy DualSelect Install Instructions

Taper
Install Instructions

Ce manuel convient également à

page 1 www.stonco.com
Garage & Canopy
LED Lighting Fixture
GC60-SCT-G2-SM-5-10-BZ
GC90-SCT-G2-SM-5-10-BZ
Always turn off the power before you perform installation and maintenance.
•Verify that supply voltage is correct for the specified voltage range of the luminaire shown on the label, i.e. 120-347V.
•Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code
requirements.
•All wiring connections must be capped with UL approved devices for this purpose.
CAUTION: RISK OF INJURY
•Avoid direct eye exposure to the illuminated light source.
•Put aside small parts and dispose packing material properly, to prevent hazard to children.
•Install and use only as intended according to UL, all applicable codes and regulations and these
instructions.
CAUTION: Use weatherproof silicone sealant between the ceiling plate and mounting surface.
Illustrations in the manual are for installation purpose only. Installation may vary depending on the specific
luminaire model.
CAUTION: RISK OF FIRE
GENERAL SAFETY INFORMATION
To avoid hazards and unnecessary failures due to misuse, please read carefully all
warnings and instructions included in the MI sheets and all labels.
•Before installing, servicing, or performing routine maintenance upon this equipment,
pay attention to:Supply voltage input 120-347V, frequency 50/60 Hz.
•This fixture is intended to be connected to a properly installed and grounded UL listed
junction box.
•Commercial installation, service and maintenance of luminaires should be performed
by a qualified licensed electrician.
•Residential installation, always consult a qualified licensed electrician and check your
local electrical code if any uncertainty before operating.
•Always check the product before installation.
•DO NOT INSTALL DAMAGED PRODUCT!
•Wear gloves and safety goggles at all times when removing luminaires from carton, installing, servicing or performing
maintenance.
GENERAL WIRING DIAGRAM
CAUTION: Turn off electrical power by fuse or circuit breaker box before wiring fixture to the power supply .
WARNING: RISK OF ELECTRICAL SHOCK
Approved13-04-2021
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
4. Slide fixture back
into the connecting plate
and tighten the screw.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
3. Hang the fixture onto the
connecting plate while
connecting the power cable
as the demo.
3.CCT switching position
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown(by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching position
4.1 For GC60-SCT-G2-SM-5-10-BZ (MDU:On)
4.2 For GC90-SCT-G2-SM-5-10-BZ (MDU:On)
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Screw pendant pipe up to the top of the device.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
6.Note: to ensure the protective performance of the product, the 1/2-14nps
plug must be assembled with a torque of no less than 1.7N·m.
Reassemble the 1/2-14nps plug with a torque ≥1.7 N·m after CCT or FAO switching for
ingress prevention.
Wattage Button1
ON OFF
Button2 Button3
60W
40W
28W
√ √
√ √
Wattage Button1 Button2 Button3
90W
80W
70W
√ √
√ √
13-04-2021 Approved
page 2 www.stonco.com
ON OFF ON OFF
ON OFF ON OFF ON OFF
*Remove these plugs to
access the FAO Switches
1/2-14NPS plug (4x)
1/2-14NPS Plug
1/2-14NPS Plug
*Remove these plugs
to access the CCT
Switches
1/2-14NPS plug (4x)
Garage & Canopy
page3 www.stonco.com
5. Sensor Function
5.1 Initialization
Power on, the sensor automatically turns on light at 100% brightness. 10 seconds later, it turns off the
light. During the initialization, the sensor is not able to detect movement.
The fixture is recommended that the installation height of the fixture<15m.
5.2 Operation Mode:Daylight Priority + 3-leveled dimming
3-leveled dimming function with Daylight priority
When Daylight is enough, >150 lux, motion sensing will be switched off automatically, the light will be always off.
With insufficient ambient light, <150 lux, motion sensing is activated automatically.
When motion is detected, the light turns on to 100%, after 5 min, if no motion is sensed, the light dims to 50% until
motion is detected again.
5.4 Sensor Application Notice:
5.4.1 The distance between any inductive sensor luminaires should be greater than 3m.
5.4.2 According to installation height, note sensor detection area.
5.4.3 To prevent false trigger:
1) Avoid high-density objects, such as: metal, glass, concrete walls, etc., beyond the sensor detection area.
2) Avoid moving signals beyond the sensor detection area, such as: fan, DC motor, sewer pipe, air outlet, heavy
rainfall, motion behind a thin wall, etc.
3) Avoid the shock & vibration environmental application.
5.4.4 The sensor programming always goes the process of initialization and Daylight Priority + 3-leveled dimming
operational mode; to get customized setting, recommend to utilize the sensor remote, contact your dealer.
5.4.5 The parameters of the sensor may need to be reconfigured to adapt different installation environments, please refer to
the remote instruction or contact the manufacturer.
2021.3.30 英文说明书更改
2021.5.20 英文说明书更改
2021.8.9 英文说明书更改
2021.8.19 英文说明书更改
2021.8.23 英文说明书更改
Approved13-04-2021
Default detection area setting:
GC60-SCT-G2-SM-5-10-BZ: 100% . GC90-SCT-G2-SM-5-10-BZ: 75%.
5.3 Turning the Sensor Off:
5.3.1 By Default, the Motion and Daylight sensor will be ON.
5.3.2 To Switch OFF the Sensor, move FAO Switch position 3 to the bottom position.
5.3.3 When the Sensor is turned OFF, the fixture will stay on 24/7.
Sensor OFF
Sensor ON
(Default)
page 1 www.keene.com
Signify Classified - Internal
page 1 www.stonco.com
Garage & Canopy
LED Lighting Fixture
GC60-SCT-G2-SM-5-10-BZ
GC90-SCT-G2-SM-5-10-BZ
WARNING: RISK OF ELECTRICAL SHOCK
•Always turn off the power before you perform installation and maintenance.
•Verify that supply voltage is correct for the specified voltage range of the luminaire shown on the label, i.e. 120-347V.
•Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code
requirements.
•All wiring connections must be capped with UL approved devices for this purpose.
CAUTION: RISK OF INJURY
•Wear gloves and safety glasses at all times when removing luminaires from carton, installing, servicing or performing
maintenance.
•Avoid direct eye exposure to the illuminated light source.
•Put aside small parts and dispose packing material properly, to prevent hazard to children.
CAUTION: RISK OF FIRE
•Install and use only as intended according to UL, all applicable codes and regulations and these
instructions.
CAUTION: Use weatherproof silicone sealant between the ceiling plate and mounting surface.
Illustrations in the manual are for installation purpose only. Installation may vary depending on the specific
luminaire model.
GENERAL WIRING DIAGRAM
CAUTION: Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
GENERAL SAFETY INFORMATION
To avoid hazards and unnecessary failures due to misuse, please read carefully all
warnings and instructions included in the MI sheets and all labels.
•Before installing, servicing, or performing routine maintenance upon this equipment,
pay attention to:Supply voltage input 120-347V, frequency 50/60 Hz.
•This fixture is intended to be connected to a properly installed and grounded UL
listed junction box.
•Commercial installation, service and maintenance of luminaires should be performed
by a qualified licensed electrician.
•Residential installation, always consult a qualified licensed electrician and check your
local electrical code if any uncertainty before operating.
•Always check the product before installation.
•DO NOT INSTALL DAMAGED PRODUCT!
INFORMATION GÉNÉRALE SUR LA SÉCURI
Afin d’éviter les dangers et pannes inutiles suite à une mauvaise utilisation,
veuillez lire attentivement tous les avertissements et directives inclus dans
les fiches techniques MI et sur toutes les étiquettes.
• Avant d’installer, de réparer ou d’effectuer un entretien de routine sur cet
appareil, bien prendre note de ce qui suit : entrée de tension d’alimentation
de 120-347V, fréquence 50/60 Hz
• Ce luminaire doit être installé correctement sur une boîte de jonction
homologuée UL et mise à la terre
• Dans une installation commerciale, le service et lentretien des luminaires
doivent être effectués par un électricien sous licence qualifié
• Dans une installation résidentielle, toujours consulter un électricien sous
licence qualifié et bien vérifier votre code de lélectricité local si vous avez
un doute
Toujours vérifier le produit avant l’installation
NE JAMAIS INSTALLER UN PRODUIT ENDOMMAGÉ !
AVERTISSEMENT : RISQUE DE CHOC ÉLECTRIQUE
• Toujours couper l’alimentation avant d’installer ou d’entretenir
• S’assurer que la tension d’alimentation correspond à la plage de celle du luminaire indiquée sur létiquette,
ex. : 120-347V
• Effectuer toutes les connexions électriques et de mise à la terre selon les exigences du Code de lélectricité
national et toutes les exigences du code local applicables
Toutes les connexions de câblage devraient être recouvertes de capuchons de connexions homologués UL
convenant à cette fin
ATTENTION : RISQUE DE BLESSURES
Éviter tout contact direct entre les yeux et la source allumée
• Ranger toutes les petites pièces et jeter lemballage puisqu’ils peuvent être dangereux pour les enfants
ATTENTION : RISQUE D’INCENDIE
Installer et utiliser seulement en respectant les exigences d’UL, de tous les codes et réglementations applicables
et selon ces directives
ATTENTION : utiliser un joint de silicone imperméable entre le plafond et la surface de montage.
Les illustrations de ce manuel servent uniquement à des fins d’installation. L’installation peut varier selon le modèle
spécifique du luminaire.
Security
SL20-SCT-G1-8-BK
911401872081
GENERAL SAFETY INFORMATION
Stonco Security luminaires bring high-quality, reliable safety to you. To avoid
hazards and unnecessary failures due to misuse, please read carefully all
warnings and instructions included in the MI sheets and all labels.
• Before installing, servicing, or performing routine maintenance upon this
equipment, pay attention to:supply voltage input 120-277V, frequency 50/60 Hz.
• This fixture is intended to be connected to a properly installed and grounded
UL listed junction box.
• Commercial installation, service and maintenance of luminaires should be
performed by a qualified licensed electrician.
• Residential installation, always consult a qualified licensed electrician and
check your local electrical code if any uncertainty before conduction.
• Always check the product before installation.
• DO NOT INSTALL DAMAGED PRODUCT!
WARNING: RISK OF ELECTRICAL SHOCK
• Always turn off the power before you perform installation and maintenance.
• Verify that supple voltage meet the adaption range of the luminaire shown on the label, i.e. 120-270V.
Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code
requirements.
• All wiring connections should be capped with UL approved wire connectors.
CAUTION: RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaires from carton, installing, servicing or performing maintenance.
• Avoid direct eye exposure to the lit-on light source.
• Put aside small parts and dispose packing material properly, in case hazard to children.
CAUTION: RISK OF FIRE
Keep combustible material away from the luminaires.
CAUTION: For proper weatherproof function, all gaskets must be seated properly and all screws secured tightly.
Apply weatherproof silicone sealant around the edge of the wall box, especially on an uneven wall surface. Protect all plugs and
unused conduit entries.
Illustrations in the manual are for installation purpose only. It may vary due to the different fixture purchased.
GENERAL WIRING DIAGRAM
CAUTION: Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
page 1 www.stonco.com
Garage et plafonnier
GC60-SCT-G2-SM-5-10-BZ
GC90-SCT-G2-SM-5-10-BZ
Luminaire DEL
Porter des gants et des lunettes de sécurité en tout temps lorsque vous sortez les luminaires des boîtes, que vous
réparez ou effectuez l’entretien
SCHÉMA GÉNÉRAL DE CÂBLAGE
ATTENTION: coupez l'alimentation électrique à l'aide de fusibles ou d'un disjoncteur avant de connecter l'appareil à la
source d'alimentation.
Approved13-04-2021
page 2 www.keene.com
Garage et plafonnier
Garage et plafonnier
Signify Classified - Internal
3.CCT switching method
Please remove and replace with:
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown (by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching method
4.1 For GC60-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 60W (maximum power) set all three switches to off as shown(by default).
For 40W set only the first number 1 switch to ON as shown.
For 28W set only the middle number 2 switch to ON as shown.
4.2 For GC90-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 90W (maximum power) set all three switches to off as shown(by default).
For 80W set only the first number 1 switch to ON as shown.
For 70W set only the middle number 2 switch to ON as shown.
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
3. Hang the fixture on the
connecting plate to hold it in
place while doing the wiring.
Connect the wiring as shown
below.
4. Slide fixture back
into the connecting plate
and tighten the screw.
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Thread pendant pipe to top of housing.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
page 2 www.stonco.com
Signify Classified - Internal
3.CCT switching method
Please remove and replace with:
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown (by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching method
4.1 For GC60-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 60W (maximum power) set all three switches to off as shown(by default).
For 40W set only the first number 1 switch to ON as shown.
For 28W set only the middle number 2 switch to ON as shown.
4.2 For GC90-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 90W (maximum power) set all three switches to off as shown(by default).
For 80W set only the first number 1 switch to ON as shown.
For 70W set only the middle number 2 switch to ON as shown.
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
3. Hang the fixture on the
connecting plate to hold it in
place while doing the wiring.
Connect the wiring as shown
below.
4. Slide fixture back
into the connecting plate
and tighten the screw.
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Thread pendant pipe to top of housing.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
page 2 www.stonco.com
Signify Classified - Internal
3.CCT switching method
Please remove and replace with:
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown (by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching method
4.1 For GC60-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 60W (maximum power) set all three switches to off as shown(by default).
For 40W set only the first number 1 switch to ON as shown.
For 28W set only the middle number 2 switch to ON as shown.
4.2 For GC90-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 90W (maximum power) set all three switches to off as shown(by default).
For 80W set only the first number 1 switch to ON as shown.
For 70W set only the middle number 2 switch to ON as shown.
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
3. Hang the fixture on the
connecting plate to hold it in
place while doing the wiring.
Connect the wiring as shown
below.
4. Slide fixture back
into the connecting plate
and tighten the screw.
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Thread pendant pipe to top of housing.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
page 2 www.stonco.com
1. Montage en saillie avec boîte de jonction
1. Avant de débuter vous
assurez que l’alimenta-
tion est coupée.
Sortir le luminaire de la
boîte et s’assurer qu’il
ne soit pas endomma.
2. Installer la plaque de
connexion sur le pla-
fond ou sur la boîte de
jonction (non incluse) et
tirer le fil dans le trou
central.
3. Suspendre le luminaire
sur la plaque de con-
nexion pour le retenir
en place pendant le
câblage. Connecter le
câblage comme illustré
ci-dessous.
4. Remettre le luminaire
sur la plaque de
connexion et visser
la vis.
2. Installation suspendue avec conduit de 3/4 pouce
1. Insérer les fils d’alimentation dans la tige de suspension (non incluse).
2. La connexion dans un tuyau suspendu doit être une connexion rigide.
3. Effectuer le câblage selon le dessin.
4. Visser le tuyau suspendu sur le dessus du boîtier.
5. Afin d’empêcher l’humidité de s’infiltrer dans le luminaire, appliquer un ruban de
téflon ou un gel de silicone autour du filetage du tuyau.
Noir Alimentation
Blanc Neutre
Vert Mise à la terre
Signify Classified - Internal
3.CCT switching method
Please remove and replace with:
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown (by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching method
4.1 For GC60-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 60W (maximum power) set all three switches to off as shown(by default).
For 40W set only the first number 1 switch to ON as shown.
For 28W set only the middle number 2 switch to ON as shown.
4.2 For GC90-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 90W (maximum power) set all three switches to off as shown(by default).
For 80W set only the first number 1 switch to ON as shown.
For 70W set only the middle number 2 switch to ON as shown.
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
3. Hang the fixture on the
connecting plate to hold it in
place while doing the wiring.
Connect the wiring as shown
below.
4. Slide fixture back
into the connecting plate
and tighten the screw.
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Thread pendant pipe to top of housing.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
page 2 www.stonco.com
Signify Classified - Internal
3.CCT switching method
Please remove and replace with:
For 3000K set the switch to 3KK as shown.
For 4000K set the switch to 4KK as shown (by default).
For 5000K set the switch to 5KK as shown.
4.FAO switching method
4.1 For GC60-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 60W (maximum power) set all three switches to off as shown(by default).
For 40W set only the first number 1 switch to ON as shown.
For 28W set only the middle number 2 switch to ON as shown.
4.2 For GC90-SCT-G2-SM-5-10-BZ
Please remove and replace with:
For 90W (maximum power) set all three switches to off as shown(by default).
For 80W set only the first number 1 switch to ON as shown.
For 70W set only the middle number 2 switch to ON as shown.
1.Surface-mounted with J-BOX
1.Before starting ensure
that the electrical power is
disconnected.
Unpack fixture and ensure
there is no damage.
2.Install the connecting plate
onto the ceiling or junction box
(supplied by others) and pull
the wire through center hole.
3. Hang the fixture on the
connecting plate to hold it in
place while doing the wiring.
Connect the wiring as shown
below.
4. Slide fixture back
into the connecting plate
and tighten the screw.
1.Feed incoming power leads through pendant stem (supplied by others).
2.Hanging pipe connection must be rigid connection.
3.Wiring according to the schematic.
4.Thread pendant pipe to top of housing.
5.Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent
moisture from entering.
2.Pendent Installation with 3/4 inch conduit
Garage & Canopy
page 2 www.stonco.com
emarque: pour assurerR les performances de protection du produit, la prise
1/2-14nps doit être monté avec un couple d'au moins 1,7 N·m.
6.
Pour éviter les infiltrations, remontez la fiche 1 / 2-14nps avec un couple ≥1,7 N · m après la sélection de TCP ou FAO.
Approved13-04-2021
3.Position de transfert du TDC
Pour 3000K, mettez le bouton sur 3KK comme indiqué.
Pour 4000K, mettez le bouton sur 4KK comme indiqué
(par défaut).
Pour 5000K, mettez le passage sur 5KK comme indiqué.
4.Position de la FAO
4.1 Pour GC60-SCT-G2-SM-5-10-BZ (MDU:On)
4.2 Pour GC90-SCT-G2-SM-5-10-BZ (MDU:On)
40W
60W
90W
80W
√ √
√ √
70W
Puissance
Interrupteur3
ON OFF
28W
Interrupteur2
ON OFF
Interrupteur1
ON OFF
Puissance
Interrupteur3
ON OFF
Interrupteur2
ON OFF
Interrupteur1
ON OFF
*Retirez ces prises
pour accéder aux
commutateurs FAO
Prise 1/2-14nps (4x)
Prise 1/2-14NPS
Prise 1/2-14NPS
*Retirez ces bouchons
pour accéder aux
commutateurs CCT
Prise 1/2-14nps (4x)
Garage et plafonnier
Signify Classified - Internal
1) On/OFF Function (stand-by period be set to “0”s)
2) 2-step dimming function (stand-by period be set to “+∞”)
Garage & Canopy
page 3 www.stonco.com
5.Sensor description
5.1 Factory Setting
Detection area: 100%
Hold Time: 5S
Stand-by Period: 0s
Stand-by dim level: 10%
Daylight Sensor: Disable
5.2Sensor Function
Signify Classified - Internal
1) On/OFF Function (stand-by period be set to “0”s)
2) 2-step dimming function (stand-by period be set to “+∞”)
Garage & Canopy
page 3 www.stonco.com
5.Sensor description
5.1 Factory Setting
Detection area: 100%
Hold Time: 5S
Stand-by Period: 0s
Stand-by dim level: 10%
Daylight Sensor: Disable
5.2Sensor Function
5. Fonction du capteur.
5.1 Initialization
de Allumé, le capteur allume automatiquement le luminaire à 100% de luminosité. 10 secondes plus tard, éteignez la lumière.
Pendant initialisation, le capteur est incapable de détecter un mouvement.
Il est recommandé d'installer l'appareil à une hauteur <15 m.
5.2 Mode de fonctionnement: Priorité lumière du jour + variation à 3 niveaux
Fonction de variation à 3 niveaux avec priorité à la lumière du jour
Lorsque la lumière du jour est suffisante, >150 lux, la détection de mouvement s'éteint, la lumière est toujours éteinte.
En cas de lumière ambiante insuffisante, <50 lux, la détection de mouvement est activée.
Lorsqu'un mouvement est détecté, la lumière s'allume à 100%, après 5 minutes, si aucun mouvement n'est détecté, la
lumière est tamisée à 50% jusqu'à ce qu'un mouvement soit à nouveau détecté.
d’éclairage ambiant,
la lumière ne
s’éteindra pas même
si le mouvement est
détecté.
d’éclairage ambiant,
le capteur allume
la lumière lorsque
le mouvement est
détecté.
tention écoulé, le
capteur atténue la
lumière à faible niveau si
un nouveau mouvement
est détecté.
tention écoulé,
le capteur éteint la
lumière lorsqu’aucun
mouvement nest
tecté dans la zone
de détection.
5.4 Avis d'application du capteur:
5.4.1 La distance entre tout luminaire équipé d'un capteur inductif doit être supérieure à 3
mètres (9,8 pieds).
5.4.2 En fonction de la hauteur d'installation, observez la zone de détection du capteur.
5.4.3 Pour éviter une fausse activation:
1) Évitez les objets à haute densité, tels que: métal, verre, murs en béton, etc., au-delà de la zone de détection du capteur.
2) Évitez de déplacer les signaux au-delà de la zone de détection du capteur, tels que: ventilateur, moteur à courant continu,
tuyau d'égout, sortie d'air, pluie, mouvement derrière une paroi mince, etc.
3) Évitez l'application environnementale de chocs et de vibrations.
5.4.4 La programmation du capteur passe toujours par le processus d'initialisation et de priorité de la lumière du jour +
gradation à 3 niveaux Mode opérationnel; Pour un réglage personnalisé, il est recommandé d'utiliser la télécommande du
capteur, contactez votre revendeur.
5.4.5 Les paramètres du capteur peuvent devoir être reconfigurés pour s'adapter à différents environnements
d'installation, veuillez reportez-vous aux instructions de la télécommande ou contactez le fabricant.
© 2020 Signify Holding. Tous droits réservés. L’information retrouvée dans la présente
sujette à changement sans préavis. Signify ne fait aucune déclaration ni ne donne est
aucune garantie quant à lexactitude et à lexhaustivité des informations fournies
dans les présentes et ne serait être tenu responsable de toute mesure prise sur leur
fondement. Les informations présentées dans ce document ne constituent pas une
offre commerciale et ne font partie d’aucun devis ni contrat, à moins qu’il nen soit
convenu autrement avec Signify.
Signify North America Corporation
200 Franklin Square Drive,
Somerset, NJ 08873
Téléphone 855-486-2216
Signify Canada Ltd.
281 Hillmount Road,
Markham, ON, Canada L6C 2S3
Téléphone 800-668-9008
Toutes les marques déposées appartiennent à SignifyHolding et à leurs propriétaires
respectifs.
page 3 www.keene.com
1 Avec suffisamment 2 Avec trop peu 3 Une fois le temps de 4 Une fois le temps de
2021.3.30 文说明书更改
2021.8.9 法文说明书更改
2021.8.19 法文说明书更改
2021.8.23 法文说明书更改
Approved13-04-2021
5.3 Éteignez l'interrupteur:
5.3.1 Par défaut, le capteur de mouvement et de lumière du jour sera activé.
5.3.2 Pour éteindre le capteur, déplacez la position 3 du commutateur FAO vers la position
inférieure.
5.3.3 Lorsque le capteur est éteint, le luminaire reste allumé 24 heures sur 24, 7 jours sur 7.
Capteur
désactivé
Capteur activé
(Défaut)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Stonco LED General Purpose Garage and Canopy DualSelect Install Instructions

Taper
Install Instructions
Ce manuel convient également à