vitapur Advance Installation Instructions & Owner's Manual

Taper
Installation Instructions & Owner's Manual
Before using UV System, read this manual and follow all safety rules and operating instructions.
ATTENTION : Avant d’utiliser le système UV, veuillez lire ce manuel et suivre toutes les règles de sécurité et instructions d’utilisation.
Installation Instructions & Owner’s Manual
Instructions d’installation et manuel de l’utilisateur
ADVANCED
ADVANCED
Ultraviolet (UV) Water Treatment System
Système de traitement de l’eau à l’ultraviolet (UV)
NSF-55 CLASS A / CLASSE A NSF-55: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B / CLASSE B NSF-55: VUV-S375B, VUV-S375MB, VUV-S645B, VUV-
S645MB, VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B, VUV-
H645MB, VUV-H940B, VUV-H940MB
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance.
Testé et certifié par la NSF International aux
conditions de la norme 55 de NSF/ANSI
pour des performances de désinfection.
VPL-2 / VPL-6 / VPL-8 / VPL-12
1
Safety InStructIonS:
Statement of applIcatIon
This Class A system conforms to NSF/ANSI 55 for the disinfection of microbiologically contaminated
water that meets all other public health standards. The system is not intended to convert wastewater
or raw sewage to drinking water. This system is intended to be installed on visually clear water. NSF/
ANSI 55 denes wastewater to include human and/or animal body waste, toilet paper and any
other material intended to be deposited in a receptacle designed to receive urine and/or feces
(blackwaste); and other waste materials deposited in plumbing xtures (greywaste).
If this system is used for the treatment of untreated surface waters or ground water under the direct
inuence of surface water a device found to be in conformance for cyst reduction under the
appropriate NSF/ANSI standard shall be installed upstream of the system.
Note: If there is any type of system failure with a Class A system water must be boiled before use
or consumption. System must be cleaned before use after a system failure, See In-House Water
Distribution System Disinfection section of manual.
This Class B system or component conforms to NSF/ANSI 55 for the supplemental bactericidal
treatment of disinfected public drinking water or other drinking water that has been tested
and deemed acceptable for human consumption by the state or local health agency having
jurisdiction. The system is only designed to reduce normally occurring non-pathogenic nuisance
microorganisms. Class B systems are not intended for treatment of contaminated water.
Congratulations
on purchasing a Vitapur
®
UV Water Treatment System. You have taken the rst step in
ensuring your water is safe for yourself and your family. This system has been designed to disinfect your water
source using UV technology, which has been proven to kill bacteria and viruses including E. coli, Salmonella,
Legionella as well as cysts such as Giardia lamblia and Cryptosporidium. The Vitapur
®
UV system is a natural
non-chemical, environmentally friendly safe technique for water disinfection treatment that will give you years
of peace of mind.
Do not attempt to install, operate, clean or perform routine maintenance on your
Vitapur® UV system unless you have rst read and understand all of the warnings and
safety instructions that are contained in this manual and on the labels that are afxed to the system.
Do not attempt to operate the Vitapur® UV system if it has been visibly damaged, (e.g.,
due to shipping) or if it may have sustained damage, (e.g., if the unit has been dropped).
To prevent faulty operation of the system, inspect it carefully to ensure it is free of physical
damage before using.
Never start your Vitapur® UV system, (e.g., after the initial installation) before conrming
that the exterior is dry and that there are no visible leaks.
The Vitapur® UV system is designed for indoor applications only and should not be
exposed to outdoor elements.
Always install and operate the unit in an environment where both the air and water
temperatures will normally range between 36°F (2°C) and 104°F (40°C).
The installation of this system must be in accordance with all provincial/
state and/or local laws and regulations regarding plumbing and electrical
services. Installation by a certied plumber is recommended. Always
comply with the following warnings and safety instructions, to prevent
bodily harm, injury or property damage.
2
product overvIew:
uv SyStemS wIth monItor port optIon
The Vitapur
®
Ultraviolet (UV) Water Treatment System has been engineered to rigid standards, and
has been quality inspected at the factory prior to packaging. Please review this manual in its entirety
for a detailed system explanation, and ensure that the following components accompany this
system: To ensure system performance, all replacement components should be purchased directly
from an authorized dealer or directly from Greenway Water Technologies (www.greenwaywt.com).
The use of components purchased from other sources will void the warranty, and will potentially
cause the system to function in a lesser capacity than intended.
DANGER: The lamp inside the unit emits ultraviolet light that can cause permanent damage to skin
and eyes. Never look at the lamps when unit is operating.
Never attempt to operate your Vitapur® UV system unless it has rst been properly grounded,
to avoid creating an electric shock hazard.
To prevent an electric shock, do not plug the Vitapur® UV system into any socket that has not
been equipped with a Ground Fault Circuit Interrupter (GFCI).
Always unplug the power cord before attempting to install, clean or perform other routine
maintenance on the unit.
Always stop the inlet water ow before performing any maintenance on the unit.
Do not attempt to service this unit unless you are an accredited service technician, as personal
injury could result and/or system operation could be detrimentally affected.
Never operate this unit in an oxygen-rich environment, or within 6 feet (2 meters) of any oxygen
source.
If temperatures should fall below freezing (0°C / 32°F), drain all water from the unit, drain and
disconnect all plumbing lines, and cap the inlet and outlet ports.
!
Power (green)
Lamp Failure
(red)
!
Power
(green)
Lamp Failure (red)
!
Power (green)
Lamp Failure (red)
!
Power
(green)
Lamp Failure
(red)
Owners Manual
Electronic Ballast
(Includes lamp connector)
UV Lamp
Quartz Sleeve
Stainless Steel UV Reaction Chamber
Power Cord
Ring
Glass Insert
O-Ring
VuCap
UV Cylinder
Mounting
Clamps and
screws
Retaining Nut
Quartz Sleeve
Sealing O-Ring
Hardware Kit
(2 screws, 2 anchors)
!
Power (green)
Lamp Failure
(red)
Before using UV System, read this manual and follow all safety rules and operating instructions.
ATTENTION : Avant d’utiliser le système UV, veuillez lire ce manuel et suivre toutes les règles de sécurité et instructions d’utilisation.
Installation Instructions & Owner’s Manual
Instructions d’installation et manuel de l’utilisateur
ADVANCED
ADVANCED
Ultraviolet (UV) Water Treatment System
Système de traitement de l’eau à l’ultraviolet (UV)
NSF-55 CLASS A / CLASSE A NSF-55: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B / CLASSE B NSF-55: VUV-S375B, VUV-S375MB, VUV-S645B, VUV-
S645MB, VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B, VUV-
H645MB, VUV-H940B, VUV-H940MB
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance.
Testé et certifié par la NSF International aux
conditions de la norme 55 de NSF/ANSI
pour des performances de désinfection.
x2
fIgure 1
3
about your SyStem:
A minimum 5 µ nominal pre-lter is recommended upstream (before) the UV system installation
point. As UV system efciencies are dictated by penetration of the UV light through the water
column, particulate matter within the water column could decrease the disinfection capacity, and
potentially create a harmful condition (ltration systems sold separately).
* To meet NSF/ANSI 55 Class A requirements, these systems must be used in conjunction
with Vitapur OWL UV sensor option.
* Class A rated ow at least equivalent to 40 mJ/cm at UV sensor alarm set point.
Lamps must be replaced after 12 months of operation to ensure
proper disinfection of your water
Clean Quartz Sleeve frequently for optimum performance
!
Power (green)
Lamp Failure
(red)
!
Power (green)
Lamp Failure
(red)
!
Power
(green)
Lamp Failure
(red)
!
Power (green)
Lamp Failure
(red)
Owners Manual
Electronic Ballast
(Includes lamp connector)
UV Lamp
Quartz Sleeve
Stainless Steel UV Reaction Chamber
Power Cord
VuCap
UV Cylinder
Mounting
Clamps and
screws
Retaining Nut
Quartz Sleeve
Sealing O-Ring
Hardware Kit
(2 screws, 2 anchors)
Before using UV System, read this manual and follow all safety rules and operating instructions.
ATTENTION : Avant d’utiliser le système UV, veuillez lire ce manuel et suivre toutes les règles de sécurité et instructions d’utilisation.
Installation Instructions & Owner’s Manual
Instructions d’installation et manuel de l’utilisateur
ADVANCED
ADVANCED
Ultraviolet (UV) Water Treatment System
Système de traitement de l’eau à l’ultraviolet (UV)
NSF-55 CLASS A / CLASSE A NSF-55: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B / CLASSE B NSF-55: VUV-S375B, VUV-S375MB, VUV-S645B, VUV-
S645MB, VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B, VUV-
H645MB, VUV-H940B, VUV-H940MB
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance.
Testé et certifié par la NSF International aux
conditions de la norme 55 de NSF/ANSI
pour des performances de désinfection.
x2
uv SyStem wIthout monItorIng port
Specifications:
NSF/ASNI Standard 55 Class A
Model number:
VUV-S375MA VUV-S645MA VUV-S940MA VUV-H375MA VUV-H645MA VUV-H940MA
Flow Rate GPM US (LPM) (I)
2.9 (11.3) 4.9 (18.7) 7.5 (28.5) 6.4 (24.3) 10.6 (40.2) 16.1 (61.3)
Dimen-
sions
Ballast
8” x 3” x 2” (20.3 cm x 7.6 cm x 5.1 cm)
Chamber Diameter
3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm)
Chamber Length
17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm) 17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm)
I/O Port Size
3/4” FNPT - 1.0” MNPT
System Maximum Operating Pressure 125psi (862 kPa)
Electrical
Voltage
100-240, 50/60Hz
Power Consumption (W)
21 35 46 42 67 98
Lamp Watts (W)
17 30 40 35 60 90
Chamber Material
304SS
fIgure 2
* Class B rated ow at least equivalent to 16 mJ/cm
2
4
water QualIty parameterS:
Water quality will adversely affect the performance of your Vitapur® UV disinfection system, and the
following levels should be utilized as a guideline for pre-treatment requirements of the inuent water
supply prior to UV treatment:
Iron Total iron count must be less than 0.3 ppm (0.3 mg/L)
Turbidity Count must be less than 1 NTU
Tannins Count must be less than 0.1 ppm (0.1 mg/L)
Manganese Count must be less than 0.05 ppm (0.05mg/L)
Hardness Count must be less than 120 ppm (7 grains per gallon)
%UVT (transmittance) Must be greater than 75%
If you are using untreated surface water or untreated groundwater as your source of supply, the
suitability of the water supply for potable applications must be conrmed by the provincial / state
and/or local health agency that has jurisdiction.
If the test results indicate that: (1) any of the above contaminant levels are being exceeded, or (2)
any prevailing drinking water health standards are not being met, additional pre-treatment options
must be installed that will eliminate all contaminants posing health risks. Non-municipal water should
be tested on an ongoing basis to ensure treatment efciency.
Specifications:
NSF/ASNI Standard 55 Class B
Model number:
VUV-S375B
VUV-S375MB
VUV-S645B
VUV-S645MB
VUV-S940B
VUV-S940MB
VUV-H375B
VUV-H375MB
VUV-H645B
VUV-H645MB
VUV-H940B
VUV-H940MB
Flow Rate GPM US (LPM) (I)
7.4 (28.2) 12.3 (46.6) 18.7 (71.1) 15.8 (60) 26.4 (100) 40.4 (153)
Dimen-
sions
Ballast
8” x 3” x 2” (20.3 cm x 7.6 cm x 5.1 cm)
Chamber Diameter
3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm)
Chamber Length
17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm)
17.25” (43.8 cm) 27.88” (70.8 cm)
39.5” (100.3 cm)
I/O Port Size
3/4” FNPT - 1.0” MNPT
System Maximum Operating Pressure 125psi (862 kPa)
Electrical
Voltage
100-240, 50/60Hz
Power Consumption (W)
21 35 42 46 67 98
Lamp Watts (W)
17 30 35 40 60 90
Chamber Material
304SS
Recommended installation of the Vitapur
®
UV disinfection system is as follows:
* UV chamber can be mounted vertically or horizontally (see gure 4 on next page).
* Union ttings are recommended in the event UV system needs to be removed from service.
5
InStallatIon InStructIonS: optIonal bypaSS lIne and draIn valve:
To prevent contamination of water in the plumbing, which may pose a health hazard, do not
use the bypass line and valve if your source of supply is untreated surface water or groundwater.
If your source of supply is treated municipal water, use of the bypass line and valve will permit
uninterrupted treated water service in the event of a system malfunction. Always test the bypass
valve following each use of the bypass line, prior to re-starting the Vitapur
®
UV disinfection system
to conrm that the valve has been fully closed and that only water from the outlet port will be
going downstream. The installation of a drain valve, while not required for system operation, is
recommended for all installations of the Vitapur
®
UV disinfection system. The installation of a drain
valve will allow the service technician to drain the system of water prior to conducting any service
on the unit.
InStallatIon InStructIonS: acceSSIbIlIty, orIentatIon & fIttIngS:
Always mount the Vitapur
®
UV in a location that provides ample space for accessing the ultraviolet
lamps. Service may require removing the UV lamp and quartz tube. A minimum distance equivalent
to the length of the UV reaction chamber (stainless steel cylinder) plus 6-12” (15-30cm) is required
to ensure adequate clearance. As the Vitapur
®
UV disinfection system generates heat during use,
please ensure that no combustible items come into contact with, or are in proximity to the system. It
is recommended that you maintain at least 6” (15 cm) of clear wall space on all sides of the Vitapur
®
UV for cooling purposes. This will prolong the operating life of the system. Mount electronic controllers
where they will not get wet during maintenance or from condensation from copper pipes, etc.
fIgure 3
6
InStallatIon InStructIonS: InStallatIon of SyStem:
Electronic Control
Ballast
UV Reaction Chamber
Treated
Water
Exits
GFCI
Water Supply
Horizontal installation
System Orientation – Vitapur
®
Advance UV systems should be installed either horizontally
or vertically, with the outlet port at the top of the system and the inlet port at the base, as
shown in the diagrams below.
Ensure ballast is kept dry and away from any potential condensation. Use drip loops so moisture
does not run down lamp harness or power cord and into ballast.
Prior to installation, remove protective caps from inlet and outlet ports of the UV reaction chamber.
Electronic Control
Ballast
UV Reaction
Chamber
Treated
Water
Exits
GFCI
Water
Supply
Veritcal installation
partS breakdown:
When handling the UV lamps and quartz sleeves, soft gloves or a cloth should always be used to prevent
oil deposits on the surface. Oil deposits from your hands can create hot spots on the surface which may
lead to premature bulb failure.
Determine a suitable location and ensure mounting of the UV system in the correct orientation can be
completed.
Attach the mounting clamp to the installation structure using an appropriate screw type for both the
weight and material of the surface.
Position the UV reactor chamber into the mounting clamp and secure.
Install all inlet / outlet plumbing to the system (inclusive of all pre-ltration and valve set-ups described above.
Mount the electronic ballast in a dry location close to the UV reaction chamber. Install power cord
and lamp harness using drip loops (see illustration on previous page) to prevent moisture from travelling
along cable and into ballast. If system is a Class A system remove plug, glass insert and O-ring. Screw
OWL sensor with O-ring into sensor port and tighten. Care should be taken not to twist or pull sensor wire
during tightening. Mount OWL controller as specied in OWL manual.
Ensure the quartz sleeve is intact and that both the silicone o-ring, VuCap retaining ring and retaining nut
are in position and tightened (do not overtighten the retaining nuts, these should be hand tightened only).
Connect the four pins of the UV lamp to the UV lamp plug on the ballast.
Insert the UV lamp into the quartz sleeve and secure the VuCap protective cover.
Ballast
UV Chamber
Power Cord
Mounting
Screws
Wall
Anchor
Lamp Connector
Quartz Sleeve
Spring Inside
Quartz Sleeve
Outlet Port
Inlet Port
Cell Clamps
VuCap
Plug Glass
Insert
O-Ring
O-Ring
UV Lamp
Retaining Nut
Ground
and Wire
!
Power (green)
Lamp Failure (red)
fIgure 4
7
In-houSe water dIStrIbutIon SyStem dISInfectIon:
The following procedure is recommended for installations of the Vitapur
®
UV disinfection system in a
whole house treatment application. For systems installed on a municipally treated water system, plumbing
system disinfection is at the discretion of the user.
To disinfect the distribution system, carry out the following steps (please ensure that the UV system remains on
during the entire process):
Familiarize yourself with the various shut-off valves on your system. It is important to understand which
combinations of valve positions allow you to isolate the Vitapur® UV disinfection system
Shut the main water supply off
Close the valves necessary to isolate the UV Prelters. Remove the lter cartridge closest to the UV. Fill the
sump with 1-2 cups of household chlorine bleach (5.25%).
Re-install the sump (without lter) and slowly re-pressurize the system. Open each faucet and allow cold
water to run until you can smell chlorine in the water. Shut off the faucet and repeat with all other household
faucets including hot water. Be sure to include all exterior faucets, shower heads, and dishwasher / washing
machine lines within this process.
Allow the solution to remain in the lines for 30 minutes minimum.
Re-install the pre-lter cartridge, and ush each individual water line as above until no chlorine odor is detected.
It is critical to ensure that the water distribution system is fully ushed of all residual chlorine prior to use.
EXTREME CAUTION SHOULD BE EXERCISED. As the level of chlorine in the system is approximately 25-50
times greater than that observed in municipally treated water (this is required for the disinfection of the
household lines). It is extremely important that proper ushing procedures be followed from all taps prior to use.
Note: The introduction of a chlorine disinfection solution to a hot water heater that has been used with
untreated hard water or water with excessive iron, manganese or other organic contaminants may lead
to oxidization of these materials. If you feel that these conditions may apply to your installation, a thorough
ushing of the hot water tank should be done to eliminate the oxidized material from entering the distribution
lines.
* Chlorine may cause OWL controller to enter alarm. If inlet solenoid valve is connected to OWLcontroller,
valve will close and stop water ow. To allow temporary water ow, press alarm disable button on OWL
controller to override alarm and open valve temporarily. OWL controller will reset when low UV alarm signal
is cleared.
1 2 3 4
Slowly open the supply valves before and after the UV system and ensure there are no water leaks.
For Class A And B Models: Connect the electronic ballast to the power outlet, and ensure that
both the ballast display (indicates lamp life remaining) and the green LED illuminate. The glow from
the UV lamp should also be visible through the VuCap (May not be visible in high ambiant lighting)
Your UV disinfection system is now ready for use.
For Class A models: After powering up the lamp, plug UV sensor into OWL controller and connect
the OWL controller to power outlet. Refer to OWL manual for set up and programming instructions.
8
The UV system should remain on continuously to ensure protection of your water system. During normal
operation of the system, the green power LED light will be illuminated and the display will indicate the number
of days remaining until lamp replacement is required.
During periods of non-use, it is normal for the temperature of the water in the cylinder to rise. Simply ushing
the water line will alleviate this condition. During humid conditions, sweating, or small water droplets may
be noticed on the surface of the UV reaction chamber. The formation of condensation during high humidity
conditions is normal. Do not allow condensation to drip onto ballast or the Class A system OWL controller.
The following instructions have been provided to assist with general maintenance of the system; UV lamp
replacement and quartz sleeve cleaning/ replacement. All other system repairs must be completed by an
accredited service technician.
For system repairs, rst contact your local water treatment dealer where you purchased this product or an
accredited service technician by calling our Customer Service Center at 1-888-592-8370
WARNING: Never attempt to service the Vitapur
®
UV system unless you are an accredited service technician,
as the performance of the system could be adversely affected.
WARNING: The lamp heats up after continuous use and can burn your skin if touched. Allow lamp to cool for
at least 5 minutes before removing. Do not operate the UV lamp outside of the reactor. The lamp in the unit
emits powerful Ultraviolet light that can cause permanent damage to skin and eyes. Never look at the lamp
when the unit is turned on. Handle the UV lamp by the ends only. Do not touch the bulb of a lamp with your
ngers. If the surface of the lamp becomes dirty, use a clean lint-free cloth and isopropyl alcohol to remove
the dirt.
Your Vitapur
®
UV disinfection system is equipped with a visible / audible lamp failure indicator. In the event
of a failure of the UV lamp, the red LED light will ash and a loud beeping will be audible from the electronic
ballast of the unit. The lamp life countdown timer will stop decrementing. Please note that if these conditions
occur and you are on a non-municipal supplied water source, you should immediately stop using the water
for potable applications until the lamp is replaced and disinfection of the distribution lines is completed.
The ultraviolet lamp has an approximate life of one year (9000 Hrs.). Although the UV lamp will continue to
operate long past 9000 hours, the UV output continually decreases after 9000 hours, and the UV lamp may
no longer provide adequate disinfection. The built in 365 day countdown timer displays the number of days
remaining until lamp replacement is required. When countdown timer reaches 0 days an intermittent audible
alarm will be activated and display will indicate alarm A3. In order to allow time to obtain a replacement
UV lamp, the audible alarm can be silenced for 7 days by pressing and holding button on ballast for 2-5
seconds. After 7 days, alarm will sound again if lamp has not been replaced. This can be done a maximum of
4 times which allows a total of 28 days to obtain a replacement UV lamp. After 4 times, alarm can no longer
be silenced until a replacement lamp is installed and the lamp life alarm is reset to 365 days by pressing and
holding button for 10 seconds.
Replacement UV lamps and quartz sleeves are available from an authorized dealer. Use only Vitapur
®
lamps
and sleeves to ensure system performance. Replacement lamps and quartz sleeves are sold under the
following model numbers:
operatIon & maIntenance:
lamp InStallatIon and replacement:
procedure for replacIng / InStallIng the ultravIolet (uv) lamp:
• Depressurize chamber by turning off the inlet water supply and open valve downstream of system. Then close
outlet valve.
• Unplug the ballast from the electrical outlet.
• Allow at least 5 minutes for lamp to cool.
• Remove the connector from the end of the UV lamp.
• Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only
by the ceramic tips.
• Insert the new UV lamp into the quartz sleeve and attach the connector.
• Repressurize system by slowly opening water inlet valve.
• Check the system for leaks.
• Plug in ballast to the electrical outlet.
• Ensure that the UV lamp is operating – the green power LED light should be illuminated, the red lamp failure
LED light should be off and no audible alarm should be active.
• Display will show number of days until lamp replacement is required. If a new lamp was installed. Press and
hold button on ballast for 10 seconds to reset countdown timer.
Mineral deposits and sediment build-up on the quartz sleeve will affect the system performance by decreasing
the UV light transmitted through the quartz sleeve into the water column.
The proper maintenance and replacement of the pre-ltration required for the UV system will reduce the
accumulation of mineral and sediment residue on the quartz sleeve.
The quartz sleeve may be cleaned with a commercially available, non-abrasive, scale remover (should be acidic)
and a lint free cloth. Cleaning of the quartz sleeve should be done on a regular basis to ensure maximum system
performance. The amount of cleaning required will vary depending upon local water conditions.
All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system.
Care should be taken to prevent any cleaning uid from coming into contact with the inside surface of the
quartz sleeve.
Model #
Replacement Parts
Ballast UV Lamp Quartz Sleeve
S
O
S
E
R
I
E
S
VUV-S375B
VUV-S375MB
VUV-S375MA
BA-40S GUVL-330S GQS-330D
VUV-S645B
VUV-S645MB
VUV-S645MA
BA-40S GUVL-600S GQS-600D
VUV-S940B
VUV-S940MB
VUV-S940MA
BA-40S GUVL-893S GQS-893D
H
O
S
E
R
I
E
S
VUV-H375B
VUV-H375MB
VUV-H375MA
BA-95H GUVL-330H GQS-330D
VUV-H645B
VUV-H645MB
VUV-H645MA
BA-95H GUVL-600H GQS-600D
VUV-H940B
VUV-H940MB
VUV-H940MA
BA-95H GUVL-893H GQS-893D
9
10
procedure for removIng / InStallIng the Quartz Sleeve:
Turn off the water supply at both ends of the system.
Unplug the unit.
Drain water from the Stainless Steel UV Chamber.
Allow at least 5 minutes for lamp to cool.
Remove the connector from the end of the UV lamp.
Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only
by the ceramic tips.
Remove the retaining nut securing the quartz sleeve into the chamber
Remove the quartz sleeve sealing O-ring
Remove the quartz sleeve and clean as noted above.
Insert quartz sleeve into the UV chamber. Quartz sleeves should be replaced every 3 years for optimal
performance
Insert UV lamp into the quartz sleeve and attach the connector.
Slowly rell the UV chamber by opening the water supply just enough to ll the chamber with water.
Check the system for leaks.
Apply power to the UV system
Ensure that the UV lamp is operating by verifying ballast green LED indicator is on and display is operational
If your system is only being used seasonally, it must be stored properly for the winter. Disconnect your system
from the power source and drain all water from the system.
Before placing the system back in service, disinfection of the household plumbing system is strongly
recommended.
troubleShootIng guIde:
PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION
Warm water output
Water sitting in UV reaction chamber
and heating up due to infrequent use
Run tap for a short period of time
Unit leaking water
Misaligned or cross-threaded
connections on inlet / outlet ports
Excessive water pressure
Water hammer* causing pressure spikes
Reinstall to ensure a solid connection
with ports
Install pressure regulator ahead of
system
Install a “Water Hammer” arrestor in
system
No power to UV lamp
when system is plugged
in
GFCI wall socket is tripped
Reset, following manufacturer’s
instructions provided with the outlet
Check socket with other appliances
System has power but UV
lamp is not coming on
(visible / audible alarm
activated)
Lamp not installed correctly
Lamp failure
Ensure lamp is installed correctly with
electrical tting (must be snug)
Replace UV lamp
System is vibrating
Not mounted securely
Water hammer* causing vibrations
Secure fasteners
Install a “Water Hammer” arrestor in system
Excessive heat
generated
Not being allowed sufcient space for
cooling
Operated in an excessive ambient
temperature
Water temperature is too high
Clear space for cooling (min. 6-12” / 15-
30 cm clearance around unit)
Unplug unit until temperature is within
ambient operating conditions
Ensure treatment is on cold water side
only (prior to heating of water)
11
Water Technologies
Water Technologies
Water Technolo
g
ies
Engineered for Health - Designed for Life
USA: 1270 Flagship Dr. Perrysburg, OH, 43551
Phone: 1-419-874-6770 Fax: 419-874-6769
Canada: 400 Southgate Dr Guelph, ON, N1G 4P5
Phone:1-888-5-WATER-0
Fax:
519-837-8913
www.greenwaywt.com
*Water Hammer: Sudden closure of a control valve or stopping of a pump produces excessive pressure surges in a
pipeline. These pressure surges can cause signicant damage to equipment and/or appliances directly attached to
the water line. Water hammer is usually noted due to the characteristic banging sounds when valves on the line are
suddenly closed. Water hammer conditions must be immediately remedied, and damage to systems as a result of this
condition are not covered under warranty.
If you experience trouble with your system other than the symptoms described above, please visit:
12
nSf data tagS
Depending on which system you have installed you must attach one of the following Class A or
Class B tags to the UV system.
Class A System:
This system conforms to NSF/ANSI 55 for the disin-
fection of microbiologically contaminated water
that meets all other public health standards. The
system is not intended for the treatment of water
that has an obvious contamination or intentional
source such as raw sewage, nor is the system
intended to convert wastewater to microbiologi-
cally safe drinking water.
If this system is used for the treatment of un-
treated surface waters or ground water under
the direct inuence of surface water a device
found to be in conformance for cyst reduction
under the appropriate NSF/ANSI standard shall
be installed upstream of the system.
Warning: If there is any type of system failure
with a Class A system water must be boiled
before use or consumption. System must be
cleaned before use after a system failure. See
In-House Water Distribution System Disinfection
section of manual.
Always install and operate the unit in an
environment where both air and water
temperature will normally range between 36°F
(2°C) and 104°F (40°C).
See instruction manual for use conditions.
Lamp should be replaced every year (9000 Hrs.)
Ballast has built in 365 day countdown timer.
Class B System:
This system conforms to NSF/ANSI 55 for the
supplemental bactericidal treatment of
disinfected public drinking water or other
drinking water that has been tested and
deemed acceptable for human consumption
by the state or local health agency having
jurisdiction. The system is only designed to
reduce normally occurring non-pathogenic
nuisance microorganisms. Class B systems are
not intended for the disinfection of
contaminated water.
Always install and operate the unit in an
environment where both air and water
temperature will normally range between 36°F
(2°C) and 104°F (40°C).
See instruction manual for use conditions.
Lamp should be replaced every year (9000 Hrs.)
Ballast has built in 365 day countdown timer.
VPL-2 / VPL-6 / VPL-8 / VPL-12
13
InStructIonS de SécurIté :
énoncé dapplIcatIon
Ce système de classe A est conforme à la norme NSF/ANSI 55 pour la désinfection de l’eau
microbiologiquement contaminée et répond à toutes les autres normes de santé publique. Le
système n’est pas conçu pour convertir les eaux usées ou les eaux d’égout en eau potable. Ce
système est conçu pour être installé dans de l’eau visuellement claire. La norme NSF/ANSI 55 dénit
les eaux usées comme incluant les déchets corporels humains et animaux, le papier hygiénique et
tout autre matériel devant être jeté dans un réceptacle conçu pour recevoir l’urine et les excréments
(eaux-vannes), et d’autres matériaux déposés dans les installations de plomberie (eaux grises).
Si ce système est utilisé pour le traitement de l’eau de surface non traitée ou de l’eau souterraine sous
l’inuence directe de l’eau de surface, un appareil conforme pour la réduction des kystes selon la
norme NSF/ANSI appropriée doit être installé en amont du système.
Remarque : En cas de toute défaillance d’un système de classe A, l’eau doit être bouillie avant d’être
utilisée ou consommée. Le système doit être nettoyé avant l’utilisation après une défaillance du
système. Voir la section Désinfection du système de distribution d’eau de la maison du manuel.
Ce système ou cette composante de classe B est conforme à la norme NSF/ANSI 55 pour le
traitement bactéricide supplémentaire de l’eau potable publique désinfectée ou autre eau
potable ayant été testée et jugée acceptable pour la consommation humaine par l’état ou
l’agence de santé publique locale responsable. Le système est uniquement conçu pour réduire les
microorganismes nuisibles non pathogènes normalement présents. Les systèmes de classe B ne sont
pas conçus pour le traitement de l’eau contaminée.
Félicitations pour votre achat d’un système de traitement de l’eau UV Vitapur
®
. Vous avez fait le premier pas
pour assurer la sécurité de votre eau pour vous-même et pour votre famille. Ce système a été conçu pour
désinfecter votre source d’eau à l’aide de la technologie UV, qui a été éprouvée pour tuer les bactéries et les
virus incluant l’E. coli, la salmonelle, la légionelle ainsi que les kystes comme Giardia lamblia et Cryptosporidium.
Le système UV Vitapur
®
est une technique naturelle, non chimique, écologique et sécuritaire pour le traitement
de désinfection de l’eau qui vous permettra d’avoir l’esprit tranquille pendant des années.
Ne tentez pas d’installer, d’utiliser, de nettoyer ou d’entretenir votre système UV Vitapur®
si vous n’avez pas d’abord lu et compris l’ensemble des avertissements et instructions de
sécurité inclus dans ce manuel et sur les étiquettes apposées au système.
Ne tentez pas d’utiliser le système UV Vitapur® s’il a été visiblement endommagé
(p. ex. en raison de l’expédition) ou s’il pourrait avoir été endommagé (p. ex. si l’appareil a
été échappé). Pour éviter un mauvais fonctionnement du système, inspectez-le
attentivement pour vous assurer qu’il est exempt de dommages physiques avant d’utiliser.
Ne mettez jamais votre système UV Vitapur® en marche (p. ex. après l’installation initiale)
avant de conrmer que l’extérieur est sec et qu’il n’y a pas de fuites visibles.
Le système UV Vitapur® est conçu pour les applications à l’intérieur seulement et il ne
devrait pas être exposé aux éléments extérieurs.
Installez et utilisez toujours l’appareil dans un environnement où les températures de l’air et
de l’eau sont normalement entre 36 °F (2 °C) et 104 °F (40 °C).
L’installation de ce système doit être conforme à toutes les lois et règles de la
province ou de l’état et de la localité concernant les services de plomberie et
d’électricité. L’installation par un plombier certié est recommandée. Respectez
toujours les instructions de sécurité et les avertissements suivants, pour éviter des
blessures ou des dommages à la propriété.
14
vue denSemble du produIt :
SyStèmeS uv avec optIon de port de monIteur
Le système de traitement de l’eau à l’ultraviolet (UV) Vitapur® a été conçu selon des normes
strictes, et a été inspecté pour la qualité à l’usine avant l’emballage. Veuillez lire ce manuel dans
son ensemble pour une explication détaillée du système, et assurez-vous que les composantes
suivantes accompagnent ce système. Pour assurer la performance du système, toutes les
composantes de rechange devraient être achetées directement auprès d’un détaillant autorisé ou
de Greenway Water Technologies (www.greenwaywt.com). L’utilisation de composantes provenant
d’autres sources annulera la garantie, et pourrait causer un fonctionnement moins performant du
système.
DANGER : La lampe à l’intérieur de l’appareil émet de la lumière ultraviolette qui peut causer des
dommages permanents à la peau et aux yeux. Ne regardez jamais la lampe quand l’appareil est
en marche.
Ne tentez jamais d’utiliser votre système UV Vitapur® s’il n’a pas été correctement mis à la
terre, pour éviter de créer un risque de décharge électrique.
Pour prévenir une décharge électrique, ne branchez pas le système UV Vitapur® dans une
prise n’étant pas équipée d’un disjoncteur différentiel de fuite à la terre (DDFT).
Débranchez toujours le l d’alimentation avant de tenter d’installer, de nettoyer ou d’entretenir
l’appareil.
Fermez toujours l’entrée d’eau avant d’effectuer tout entretien de l’appareil.
Ne tentez pas de réparer cet appareil si vous n’êtes pas un technicien accrédité, car ceci pourrait
causer des blessures et nuire au fonctionnement du système.
N’utilisez jamais cet appareil dans un environnement riche en oxygène, ou à 6 pieds (2 mètres) de
toute source d’oxygène.
Si les températures descendent sous le point de congélation (0 °C/32 °F), drainez toute l’eau de
l’appareil, drainez et déconnectez toutes les conduites de plomberie, et fermez les ports d’entrée
et de sortie.
!
Power (green)
Lamp Failure
(red)
!
Power
(green)
Lamp Failure (red)
!
Power (green)
Lamp Failure (red)
!
Power
(green)
Lamp Failure
(red)
Manuel de l’utilisateur
Ballast électronique
(inclut le connecteur de lampe)
Lampe UV
Gaine de quartz
Chambre de réaction UV en acier inoxydable
Fil d’alimentation
Anneau
Insert de vitre
Joint torique
VuCap
Pinces de
montage
et vis du
cylindre UV
Écrou de retenue
Joint torique de la
gaine de quartz
Ensemble de matériel
(2 vis, 2 ancrages)
!
Power (green)
Lamp Failure
(red)
Before using UV System, read this manual and follow all safety rules and operating instructions.
ATTENTION : Avant d’utiliser le système UV, veuillez lire ce manuel et suivre toutes les règles de sécurité et instructions d’utilisation.
Installation Instructions & Owner’s Manual
Instructions d’installation et manuel de l’utilisateur
ADVANCED
ADVANCED
Ultraviolet (UV) Water Treatment System
Système de traitement de l’eau à l’ultraviolet (UV)
NSF-55 CLASS A / CLASSE A NSF-55: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B / CLASSE B NSF-55: VUV-S375B, VUV-S375MB, VUV-S645B, VUV-
S645MB, VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B, VUV-
H645MB, VUV-H940B, VUV-H940MB
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance.
Testé et certifié par la NSF International aux
conditions de la norme 55 de NSF/ANSI
pour des performances de désinfection.
x2
fIgure 1
15
À propoS de votre SyStème :
Un préltre à valeur nominale minimale de 5 µ est recommandé en amont du point d’installation du système
UV (avant le système). Comme l’efcacité du système UV est dictée par la pénétration de la lumière UV à
travers la colonne d’eau, les particules de matière dans la colonne d’eau pourraient réduire la capacité de
désinfection et potentiellement créer une condition nocive (systèmes de ltration vendus séparément).
* Pour répondre aux exigences NSF/ANSI 55 Classe A, ces systèmes doivent être utilisés avec
l’option de détecteur UV OWL Vitapur.
* Débit nominal de classe A au moins équivalent à 40 mJ/cm
2
au point d’alarme du détecteur UV.
• Les lampes doivent être remplacées après 12 mois d’utilisation pour assurer
la désinfection adéquate de votre eau.
• Nettoyez la gaine de quartz fréquemment pour une performance optimale.
SyStème uv SanS port de monIteur
Caractéristiques :
Norme NSF/ANSI 55 Classe A
Numéro de modèle :
VUV-S375MA VUV-S645MA VUV-S940MA VUV-H375MA VUV-H645MA VUV-H940MA
Débit nominal GPM US (LPM) (I)
2.9 (11.3) 4.9 (18.7) 7.5 (28.5) 6.4 (24.3) 10.6 (40.2) 16.1 (61.3)
Dimen-
sions
Ballast
8” x 3” x 2” (20.3 cm x 7.6 cm x 5.1 cm)
Diamètre de la chambre
3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm)
Longueur de la chambre
17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm) 17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm)
Taille du port entrée/sortie
3/4” FNPT - 1.0” MNPT
Pression de fonctionnement maximale
du système
125psi (862 kPa)
Électrique
Tension électrique
100-240, 50/60Hz
Consommation électrique (W)
21 35 46 42 67 98
Watts de la lampe (W)
17 30 40 35 60 90
Matériel de la chambre
304SS
fIgure 2
!
Power (green)
Lamp Failure (red)
!
Power (green)
Lamp Failure
(red)
!
Power (green)
Lamp Failure
(red)
!
Power (green)
Lamp Failure
(red)
Manuel de l’utilisateur
Ballast électronique
(inclut le connecteur de lampe)
Lampe UV
Gaine de quartz
Chambre de réaction UV en acier inoxydable
Fil d’alimentation
VuCap
Pinces de
montage
et vis du
cylindre UV
Écrou de retenue
Joint torique de la
gaine de quartz
Ensemble de matériel
(2 vis, 2 ancrages)
Before using UV System, read this manual and follow all safety rules and operating instructions.
ATTENTION : Avant d’utiliser le système UV, veuillez lire ce manuel et suivre toutes les règles de sécurité et instructions d’utilisation.
Installation Instructions & Owner’s Manual
Instructions d’installation et manuel de l’utilisateur
ADVANCED
ADVANCED
Ultraviolet (UV) Water Treatment System
Système de traitement de l’eau à l’ultraviolet (UV)
NSF-55 CLASS A / CLASSE A NSF-55: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B / CLASSE B NSF-55: VUV-S375B, VUV-S375MB, VUV-S645B, VUV-
S645MB, VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B, VUV-
H645MB, VUV-H940B, VUV-H940MB
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance.
Testé et certifié par la NSF International aux
conditions de la norme 55 de NSF/ANSI
pour des performances de désinfection.
x2
* Débit nominal de classe B au moins équivalent à 16 mJ/cm
2
.
16
paramètreS de QualIté de leau :
La qualité de l’eau inuencera la performance de votre système de désinfection UV Vitapur® et les
niveaux suivants devraient être utilisés comme référence pour les exigences de prétraitement de
l’eau entrante avant le traitement UV :
Fer Le compte de fer total doit être inférieur à 0,3 ppm (0,3 mg/L)
Turbidité Le compte doit être inférieur à 1 NTU
Tanins Le compte doit être inférieur à 0,1 ppm (0,1 mg/L)
Manganèse Le compte doit être inférieur à 0,05 ppm (0,05 mg/L)
Dureté Le compte doit être inférieur à 120 ppm (7 grains par gallon)
% TUV (transmission) Doit être supérieure à 75 %
Si vous utilisez de l’eau de surface ou de l’eau souterraine non traitée comme source
d’approvisionnement, la conformité de la source d’eau pour des applications d’eau potable doit
être conrmée par la province ou l’état et l’agence de santé publique locale responsable.
Si les résultats d’analyse indiquent que : (1) l’un des niveaux de contaminants ci-dessus a été
dépassé, ou (2) si les normes sanitaires concernant l’eau potable ne sont pas respectées, des
options de prétraitement additionnelles doivent être installées pour éliminer tous les contaminants
posant des risques pour la santé. L’eau non municipale devrait être testée sur une base continue
pour assurer l’efcacité du traitement.
Caractéristiques :
Norme NSF/ANSI 55 Classe B
Numéro de modèle :
VUV-S375B
VUV-S375MB
VUV-S645B
VUV-S645MB
VUV-S940B
VUV-S940MB
VUV-H375B
VUV-H375MB
VUV-H645B
VUV-H645MB
VUV-H940B
VUV-H940MB
Débit nominal GPM US (LPM) (I)
7.4 (28.2) 12.3 (46.6) 18.7 (71.1) 15.8 (60) 26.4 (100) 40.4 (153)
Dimen-
sions
Ballast
8” x 3” x 2” (20.3 cm x 7.6 cm x 5.1 cm)
Diamètre de la chambre
3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm) 3.5” (8.9 cm)
Longueur de la chambre
17.25” (43.8 cm) 27.88” (70.8 cm) 39.5” (100.3 cm)
17.25” (43.8 cm) 27.88” (70.8 cm)
39.5” (100.3 cm)
Taille du port entrée/sortie
3/4” FNPT - 1.0” MNPT
Pression de fonctionnement
maximale du système
125psi (862 kPa)
Électrique
Tension électrique
100-240, 50/60Hz
Consommation électrique (W)
21 35 42 46 67 98
Watts de la lampe (W)
17 30 35 40 60 90
Matériel de la chambre
304SS
* La chambre UV peut être montée verticalement ou horizontalement (voir la gure 4 à la page suivante).
* Des raccords unions sont recommandés dans le cas où le système UV doit être retiré.
17
InStructIonS dInStallatIon : conduIte de dérIvatIon optIonnelle et
vanne de draInage :
InStructIonS dInStallatIon : acceSSIbIlIté, orIentatIon et raccordS :
Montez toujours le système UV Vitapur® dans un endroit offrant assez d’espace pour accéder
aux lampes ultraviolettes. L’entretien pourrait nécessiter le retrait de la lampe UV et du tube de
quartz. Une distance minimale équivalente à la longueur de la chambre de réaction UV (cylindre
d’acier inoxydable) plus 6 à 12 po (15 à 30 cm) est requise pour assurer un espace adéquat.
Comme le système de désinfection UV Vitapur® génère de la chaleur durant l’utilisation, veuillez
vous assurer qu’aucun objet inammable n’entre en contact avec lui ou ne se trouve à proximité.
Il est recommandé de maintenir au moins 6 po (15 cm) d’espace de mur libre de tous les côtés du
système UV Vitapur® pour le refroidissement. Ceci prolongera la durée de vie du système. Montez
les contrôleurs électroniques où ils ne seront pas mouillés durant l’entretien ou en raison de la
condensation des tuyaux de cuivre, etc.
fIgure 3
L’installation recommandée du système de désinfection UV Vitapur® est la suivante :
Pour prévenir la contamination de l’eau dans la plomberie, ce qui pourrait poser un risque pour la
santé, n’utilisez pas la conduite de dérivation et la vanne si votre source d’approvisionnement est
de l’eau de surface ou souterraine non traitée. Si votre source d’approvisionnement est de l’eau
municipale traitée, l’utilisation de la conduite de dérivation et de la vanne permettra un service
d’eau traitée ininterrompu en cas de mauvais fonctionnement du système. Testez toujours la vanne
de dérivation après chaque utilisation de la conduite de dérivation, avant de remettre en marche
le système de désinfection UV Vitapur® pour conrmer que la vanne est bien fermée et que seule
l’eau du port de sortie circulera en aval. L’installation d’une vanne de drainage, bien que non
requise pour l’utilisation du système, est recommandée pour toutes les installations du système
de désinfection UV Vitapur®. L’installation d’une vanne de drainage permettra au technicien de
drainer le système avant d’effectuer tout entretien de l’appareil.
Ballast
Cordon
d’alimentation
Vis
d’installation
Dispositif d’ancrage
au mur
Connecteur pour lampe
Manchon en Quartz
Ressort à l’intérieur
du manchon en quartz
Orice de sortie
Orice d’entrée
Colliers de xation
VuCap
Joint torique
Lampe UV
Écrou libre
Masse et
ls
Chambre de UV
Fiche Verre
Insert
Joint
torique
!
Power (green)
Lamp Failure (red)
18
InStructIonS dInStallatIon : InStallatIon du SyStème :
installation Verticale
Orientation du système – les systèmes Vitapur® Advance UV devraient être installés
horizontalement ou verticalement, avec le port de sortie au-dessus du système et le port d’entrée
à la base, comme indiqué dans les diagrammes ci-dessous.
Assurez-vous que le ballast est sec et à l’écart de toute condensation potentielle. Utilisez des
boucles d’égouttement pour que l’humidité ne s’écoule pas le long du harnais de la lampe ou du l
d’alimentation dans le ballast.
Avant l’installation, retirez les couverts protecteurs des ports d’entrée et de sortie de la chambre de
réaction UV.
installation Horizontale
IdentIfIcatIon deS pIèceS :
En manipulant les lampes UV et des gaines de quartz, des gants doux ou un chiffon devraient toujours être
utilisés pour prévenir les dépôts huileux sur la surface. Les dépôts huileux de vos mains peuvent créer des
points chauds sur la surface qui peuvent mener à une défaillance prématurée de l’ampoule.
Déterminez un emplacement approprié et assurez-vous que le système UV peut être monté selon
l’orientation adéquate.
Fixez la pince de montage à la structure d’installation à l’aide d’une vis appropriée au poids et au
matériel de la surface.
Placez la chambre de réaction UV dans la pince de montage et xez.
Installez toute la plomberie d’entrée et de sortie au système (incluant toute installation de préltration et
de vanne décrite ci-dessus).
Montez le ballast électronique dans un endroit sec à proximité de la chambre de réaction UV. Installez le
l d’alimentation et le harnais de la lampe à l’aide de boucles d’égouttement (voir l’illustration à la page
précédente) pour empêcher l’humidité de circuler le long du l dans le ballast. Si le système est un
système de classe A, retirez la prise, l’insert de vitre et le joint torique. Vissez le détecteur OWL avec le joint
torique dans le port du détecteur et serrez. Faites attention de ne pas tordre ou tirer le l du détecteur en
serrant. Montez le contrôleur OWL comme indiqué dans le manuel OWL.
Assurez-vous que la gaine de quartz est intacte et que le joint torique de silicone, l’anneau de retenue
VuCap et l’écrou de retenue sont en place et bien serrés (ne serrez pas trop les écrous de retenue, ils
devraient être serrés à la main seulement).
Connectez les quatre branches de la lampe UV dans la prise de la lampe UV sur le ballast.
Insérez la lampe UV dans la gaine de quartz et xez le couvercle protecteur VuCap.
fIgure 4
Ballast à contrôle
électronique
Chambre de réaction UV
Sorties
d’eau
traitée
GFCI
Alimentation d’eau
Masse
et ls
Ballast à contrôle
électronique
Chambre de
réaction UV
Sorties
d’eau
traitée
GFCI
Alimentation
d’eau
Masse
et ls
19
déSInfectIon du SyStème de dIStrIbutIon deau de la maISon :
La procédure suivante est recommandée pour les installations du système de désinfection UV Vitapur®
dans une application de traitement pour toute la maison. Pour les systèmes installés sur un système d’eau
municipale traitée, la désinfection du système de plomberie est à la discrétion de l’utilisateur.
Pour désinfecter le système de distribution, suivez les étapes suivantes (veuillez vous assurer que le système UV
demeure en marche durant tout le processus) :
• Familiarisez-vous avec les diverses vannes de fermeture sur votre système. Il est important de comprendre
quelles combinaisons des positions de vanne vous permettent d’isoler le système de désinfection UV Vitapur
®
.
Fermez l’approvisionnement en eau principal.
Fermez les vannes nécessaires pour isoler les préltres UV. Retirez la cartouche de ltre la plus proche de l’UV.
Remplissez le puisard avec 1 ou 2 tasses de javellisant au chlore domestique (5,25 %).
Réinstallez le puisard (sans le ltre) et repressurisez lentement le système. Ouvrez chaque robinet et laissez l’eau
froide couler jusqu’à ce que vous puissiez sentir le chlore dans l’eau. Fermez le robinet et répétez pour tous les
autres robinets de la maison incluant l’eau chaude. Assurez-vous d’inclure tous les robinets extérieurs, pommeaux
de douche et conduites de lave-vaisselle/laveuse dans ce processus.
Laissez la solution dans les conduites durant au moins 30 minutes.
Réinstallez la cartouche de préltre, et rincez chaque conduite d’eau individuelle comme indiqué ci-dessus
jusqu’à ce qu’aucune odeur de chlore ne soit détectée.
Il est très important de s’assurer que le système de distribution d’eau est entièrement rincé de tout chlore résiduel
avant d’utiliser.
UNE EXTRÊME PRUDENCE EST NÉCESSAIRE. Comme le niveau de chlore dans le système est environ 25 à 50 fois
plus grand que celui de l’eau traitée municipale (ceci est nécessaire pour la désinfection des conduites de la
maison), il est extrêmement important de suivre les procédures de rinçage appropriées pour tous les robinets
avant d’utiliser.
Remarque : L’introduction d’une solution de désinfection au chlore à un chauffe-eau ayant été utilisé avec
de l’eau dure non traitée ou de l’eau contenant des niveaux excessifs de fer, de manganèse ou d’autres
contaminants organiques pourrait causer l’oxydation de ces matériaux. Si vous pensez que ces conditions
pourraient s’appliquer à votre installation, un rinçage en profondeur du réservoir d’eau chaude devrait être
effectué pour empêcher le matériel oxydé d’entrer dans les conduites de distribution.
* Le chlore pourrait déclencher l’alarme du contrôleur OWL. Si l’électrovanne d’entrée est connectée au
contrôleur OWL, la vanne se fermera et arrêtera l’eau. Pour permettre une circulation temporaire de l’eau,
appuyez sur le bouton de désactivation de l’alarme sur le contrôleur OWL pour désactiver l’alarme et ouvrir
temporairement la vanne. Le contrôleur OWL sera réinitialisé quand le signal d’alarme de faible niveau
d’UV sera désactivé.
1 2 3 4
Ouvrez lentement les vannes d’approvisionnement avant et après le système UV et assurez-vous qu’il
n’y a pas de fuites d’eau.
Pour les modèles de classe A et B : Connectez le ballast électronique à la prise d’alimentation, et
assurez-vous que l’afchage du ballast (indiquant la vie restante de la lampe) et le voyant DEL vert
sont allumés. Le rayonnement de la lampe UV devrait aussi être visible à travers le VuCap (pourrait
ne pas être visible avec un éclairage intense).
Votre système de désinfection UV est maintenant prêt à être utilisé.
Pour les modèles de classe A : Après avoir mis la lampe sous tension, branchez le détecteur UV
dans le contrôleur OWL et branchez le contrôleur OWL à la prise d’alimentation. Consultez le
manuel OWL pour les instructions d’installation et de programmation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

vitapur Advance Installation Instructions & Owner's Manual

Taper
Installation Instructions & Owner's Manual

dans d''autres langues