Genie GCL-GCX Operator / Installation Manual

Catégorie
Porte de garage
Taper
Operator / Installation Manual
10-14
This Installation Manual provides the information required to install, troubleshoot and
maintain a GCL-GCX
Counter Door Operator.
NOT FOR RESIDENTIAL USE
PROPER APPLICATION
Door Type Operator Type Max Door Weight/HP
Rolling Steel Counter Door 1/2HP = 500 lbs.
Counter Door
112070.502555
CO M M E R C I A L L I N E
GCL-GCX
COUNTER DOOR OPERATOR
TO PREVENT THE MOTOR PROTECTOR FROM TRIPPING,
DO NOT EXCEED 4 DOOR OPERATIONS PER HOUR.
FOR LIGHT DUTY USE ONLY.
THIS PAGE LEFT BLANK
Table of Contents
TOC
www.geniecompany.com 10-14
Section 1 How to use this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
Section 2 Safety Information & Instructions . . . . . . . . . . . . . . . . 2.1-2.2
Section 3 Critical Installation Information . . . . . . . . . . . . . . . . . . .3.1-3.4
Section 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.1-4.4
Mounting.............................. . . . . . . . . . . . .4.1-4.2
Manual Release ........................... . . . . . . . . . . . . 4.3
Optional Timer-Close or Aux. Output Modules . . . . . . . . . 4.4
Section 5 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1-5.13
Safety Information/ Line Voltage Wiring . . . . . . . . . . . 5.1-5.2
Low Voltage Control Wiring .................. . . . . . . . . . 5.3
External Wire Diagram ....................... . . . . . . . . . 5.4
Wall Control .............................. . . . . . . . . 5.5-5.6
Montored/Non-monitored Photocells ........ . . . . . . . . . 5.7
Locking Bottom Bar / Interlock Switch. . . . ..... . . . . . . . 5.10
Montored/Non-monitored Sensing Edge ..... . . . . .
5.8-5.9
External Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.11
Section 6 Operator Setup Procedure
s . . . . . . . . . . . . . . . . . . . . . . .6.1-6.8
Setting Close Direction...................... . . . . . . . . . . 6.2
6.3
Setting
Travel
Limits ....................... . . . . . . . . . . .
6.4
Control Panel ............................. . . . . . . . . . . . .
Setting
Limit
Overrun ....................... . . . . . . . . . .
6.5
Setting
Open
&
Close
Modes ................. . . . . . . . . .
6.6
6.7
Setting Mid-Stop Limit . . .................... . . . . . . . . . .
Resetting the MRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 7 Special Operational Features. . . . . . . . . . . . . . . . . . . . . 7.1-7.4
Operator Cycle Count...................... . . . . . . . . . . . 7.1
GDO & Display Firmware .................... . . . . . . . . . .7.1
Operator Type ............................ . . . . . . . . . . . .7.2
Section 8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1-8.5
Display Operation......................... . . . . . . . . . . . .8.1
Error Codes ........................... . . . . . . . . . . . . 8.1-8.2
Run Codes ............................ . . . . . . . . . . . . 8.2-8.3
LED Indicators ............................ . . . . . . . . . . . .8.4
Safe-T-Beam® Self-Diagnostic Troubleshooting Chart . .8.5
Section 9 Service & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.1
Periodic Maintenance Schedule .................. . . . . . . . . .9.1
Section 10 Appendixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1-10.7
Appendix A ........................... . . . . . . . . . . . . 10.1-10.3
Operator Parts Breakdown (Exploded View) . . . . . . 10.1
Circuit Board Breakdown . . . . . . . . . . . . . . . . . . . . . . . . 10.3
Appendix B................................. . . . . . . . . . . . . 10.4
Screw Terminal Assignments............ . . . . . . . . . 10.4
Appendix C............................ . . . . . . . . . . . . 10.5-10.7
Run Codes........................... . . . . . . . . . . . . 10.5
Error Codes. ...................... . . . . . . . . . . 10.6-10.7
Section 11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1
6.1
Release Parts Breakdown . . . . . . . . . . . . . . . . . . . . . . . . 10.2
6.8Monitored Reversing Devices . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . . . . . . . . . . . 5.12-5.13
Optional Hand Crank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.3-7.4
Section 1: How to use this manual
The 11 sections of this Installation Manual provide the information required to install, troubleshoot and maintain an GCX commercial/industrial
door operator.
Section 2
Provides important defining information related to safety terminology used throughout this manual, as well as safety related instructions which
must be followed at all times while doing any steps/tasks/instructions detailed in this manual.
Section 3
Details pre-installation concerns/issues/decisions that are recommended to be considered and/or resolved prior to beginning any commercial door
operator installation.
Sections 4-6
Provide step by step installation and set-up instructions for the GCX commercial door operator. Each section is written such that it must be
followed in a step by step order to complete a successful installation.
Sections 7-8
Detail important features and troubleshooting information for typical installation and normal operations that may occur.
Sections 9-11
Provide related information on service and maintenance items, operator drawings for use in troubleshooting and service activities, along with
important warranty and returned goods policy information.
1.1
www.geniecompany.com 10-14
Failure to correctly perform all steps in sections 4-6 can result in serious injury or death.
WARNING
AVERTISSEMENT
Ne pas effectuer correctement toutes les étapes dans les sections 4-6 peut entraîner des
blessures graves voire la mort.
Section 2: Safety Information & Instructions
IMPORTANT
READ PRIOR TO ANY DOOR OPERATION
1. Read manual and warnings carefully.
2. Keep the door in good working condition.
Periodically lubricate all moving parts of door.
3. If door has a sensing edge, check
operations monthly. Make any necessary
repairs to keep it functional.
4. AT LEAST twice a year, manually operate
door by disconnecting it from the operator.
The Door should open and close freely. If it
does not, the door must be taken out of
service and a trained service representative
must correct the condition causing
the malfunction.
5. The Operator Motor is protected against
overheating by an internal thermal protector.
If the operator ceases to function because
motor protector has tripped, a trained service
technician may need to correct the condition
which caused the overheating. When motor
has cooled, thermal protector will
automatically reset and normal operation can
be resumed.
6. In case of power failure, the door can be
operated manually by pulling the release
cable to disconnect the operator drive system.
7. Keep instructions in a prominent location
near the pushbutton.
2.1
www.geniecompany.com 10-14
WARNING
Commercial/Industrial Sectional and Rolling Steel Doors are large, heavy objects that move with
the help of
springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can
cause injuries, your safety and the safety of others depends on you reading the information in this manual. If you
have any questions or do not understand the information presented, call your nearest service re
presentative. For the
number of your local Genie® Dealer, call 800-OK-GENIE, and for Genie® Technical Service, call 800-843-4084.
In this Manual, the words Danger, Warning, and Caution are used to stress important safety information. The word:
DANGER
indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage.
The word NOTE is used to indicate important steps to be followed or important considerations.
POTENTIAL HAZARD EFFECT PREVENTION
Do Not operate unless the doorway is in sight and free of
obstructions. Keep people clear of opening while door is moving.
Do Not allow children to play with the door operator.
Do Not change operator control to momentary contact unless an
external reversing means is installed.
Do Not operate a door that jams or one that has a broken spring.
Could result in
Serious Injury
or Death
Turn off electrical power before removing operator cover.
When replacing the cover, make sure wires are not pinched or near
moving parts.
Operator must be electrically grounded.
Do Not try to remove, repair or adjust springs or anything to which
door spring parts are fastened, such as, wood block, steel bracket,
cable or any other structure or like item.
Repairs and adjustments must be made by a trained service
representative using proper tools and instructions.
HIGH SPRING TENSION
WARNING
MOVING DOOR
Could result in
Serious Injury
or Death
WARNING
Could result in
Serious Injury
or Death
WARNING
ELECTRICAL SHOCK
2.2
www.geniecompany.com 10-14
Section 2: Safety Information & Instructions
AVERTISSEMENT
Les portes de garage commerciales/industrielles à sections et en acier roulantes sont de gros objets lourds qui fonctionnent à l’aide de ressorts soumis à une haute tension et
de moteurs électriques. Dans la mesure où les objets en mouvement, les ressorts sous tension et les moteurs électriques peuvent entraîner des blessures, votre sécurité et celle
des autres exigent que vous preniez connaissance des informations stipulées dans ce manuel. Si vous avez des questions ou si vous ne comprenez pas les informations
ci-incluses, veuillez contacter le représentant de service le plus près. Pour obtenir le numéro du revendeur Genie® local, appelez le +1 (800)-OK-GENIE, et pour obtenir
des conseils techniques de l'usine Genie®, appelez le +1 (800)-843-4084.
Dans ce manuel, les mots Danger, Avertissement, et Attention sont utilisés pour faire ressortir d’importantes informations relatives à la sécurité. Le mot :
DANGER
signale une situation dangereuse imminente qui si elle n'est pas évitée, risque d'entraîner des blessures graves, voire mortelles.
Le terme REMARQUE est utilisé pour signaler les étapes importantes à suivre ou d’importants éléments à prendre en considération.
DANGER POTENTIEL
EFFET
PRÉVENTION
Utiliser uniquement si la porte est en vue et libre de tout obstacle. Ne laisser personne
se tenir dans l’ouverture de la porte pendant qu’elle est en mouvement.
Ne pas permettre aux enfants de jouer avec l’opérateur de la porte.
Ne pas modifier la commande de l'opérateur à contact momentané à moins qu'un moyen
d'inversion externe soit installé.
Ne pas faire fonctionner une porte qui bloque ou dont le ressort est cassé.
Pourrait entraîner
des blessures
graves voire la mort
AVERTISSEMENT
Pourrait entraîner
des blessures
graves voire la mort
CHOC ÉLECTRIQUE
TENSION ÉLEVÉE DU RESSORT
PORTE EN MOUVEMENT
ATTENTION
signale une situation potentiellement dangereuse qui, si elle n'est pas évitée, risque d'entraîner des blessures ou des dommages matériels.
AVERTISSEMENT
signale une situation potentiellement dangereuse qui, si elle n'est pas évitée, risque d'entraîner la mort ou des blessures graves.
Pourrait entraîner
des blessures
graves voire la mort
Couper le courant avant d’enlever le couvercle de l'opérateur.
Lorsque le couvercle doit être remplacé, s’assurer que les fils ne sont ni
coincés ni près des pièces mobiles.
L’opérateur doit être correctement mis à la terre.
Ne pas essayer d’enlever, réparer ni ajuster les ressorts ou toute autre pièce à laquelle le
ressort de la porte est attaché, y compris blocs de bois, supports en acier, câbles ou autres
articles semblables.
Les réparations et les réglages doivent être effectués par technicien qualifié qui se sert
d’outils appropriés et qui respecte les instructions.
AVERTISSEMENT
AVERTISSEMENT
3.1
Job Site Issues to Consider/Concerns
The following list of items should be considered prior to selecting an operator for a given job site.
1-Available power supply.
2-Type of door.
3-Potential operator mounting obstructions. Items to consider include, but are not limited to: side room, room above door shaft,
room below door shaft, available mounting
surface integrity, power supply location, and convenient chain hoist and release cable positioning.
4-Size of door for appropriate
operator torque and door travel speed selection.
5-Operator mounting environment. Items to consider include operator location, dampness of location, dustiness of the
location and corrosiveness of the location.
6-Door activation needs/requirements. Examples include 3 button control stations, 1 button control stations, radio controls, pull
cords, loop detectors, photoelectric controls,
key switches, etc. See “Entrapment Protection” section below.
7-Interlock switches are required under certain conditions for
doors with pass doors and door locks. See Section
5 below.
8-Accessory equipment. Examples include reversing edges and/or photocell beams, which are required for
doors set to operate as momentary contact, auxiliary control relays,
warning lights, etc.
See “Entrapment Protection” section below.
Section 3: Critical Installation Information
www.geniecompany.com 10-14
ENTRAPMENT PROTECTION
The installation of a fail safe external reversing device (such as a monitored reversing edge or photocell system, etc.) is required on all momentary contact electronically
operated commercial doors. If such a reversing device is not installed, the operator will revert to a constant contact control switch for operation (Closing only).
The Reversing Devices currently UL Approved are:
MillerEdge ME and MT series monitored edge sensors used in combination with Timer-Close Module P/N OPABTCGX.S
MillerEdge ME and MT series monitored edge sensors used in combination with MillerEdge Interface Module OPAKMEIGX.S. (Direct connect through STB inputs.)
4)
Residential Safe-T-Beam® Monitored Photocells - P/N 37220R (GSTB-BX) & 38176R.S (includes extension brackets).
5)
Series II Commercial Safe-T-Beam® Monitored Photocells - P/N OPAKPE.S and OPAKPEN4GX.S (NEMA 4).
1)
2)
6) Monitored Retro-Reflective Photoeye - P/N OPGAKRPEN4X.S
MillerEdge Wireless monitored edge sensor OPAKMMWE.S.
3)
WARNING:
DO NOT apply line voltage until instructed to do so.
AVERTISSEMENT:
NE PAS mettre sous tension tant que l'instruction n'est pas donnée de le faire.
3.2
Section 3: Critical Installation Information
www.geniecompany.com 10-14
CAUTION:
Check working condition of door before installing the operator. Door must be free from sticking and binding.
If equipped, deactivate any door locking device(s). Door repairs and adjustments, including cables and spring assemblies MUST
be made by a trained service representative using proper tools and instructions.
ATTENTION:
Vérifiez l'état de fonctionnement de la porte avant d'installer l'opérateur.
La porte doit pouvoir bouger librement et ne pas coincer. Désactivez tous les dispositifs de verrouillage de la porte (si équipés).
Les réparations et les réglages de porte, plus particulièrement pour les câbles et les ressorts DOIVENT être effectués par un
technicien qualifié qui se sert d’outils appropriés et qui respecte les instructions.
ENTRAPMENT PROTECTION
The GCX can be used with the following UL Listed entrapment devices in compliance with UL325 requirements active starting August 29, 2010.
.NOITCERID ESOLC EHT NI NOITAREPO TCATNOC YRATNEMOM WOLLA TON LLIW ROTAREPO EHT ,DELLATSNI SI SECIVED TNEMPARTNE LANRETXE DEROTINOM ESEHT FO ENO LITNU
Model HP
FIRESTAR 3” SLAT
FIRESTAR 3” SLAT
INSULATED
SHEET DOOR
16GA. 18GA. 20GA. 22GA. 24GA. 26GA. 18GA. 20GA. 22GA.
ALUM. STL/SST 20GA. 22GA.
142 108 82
94 N/A
STEEL, NON-INSULATED STEEL, INSULATED
UL
L is ted
FIRESTAR 2” SLATGRILLESCOUNTER DOOR
ALUM. STL/SST
126 126
Rolling Steel Door Chart (sq. ft.)
Note: Total door weight and not square footage is the critical factor in selecting the proper operator. These Sq.Ft. measurements are based on square doors, e.g. 16' x 16'.
Unbalanced Fire Shutters have a maximum square footage of 52 for 22GA. steel and 42 for 20GA. steel.
GCL-GCX™ 1/2 YES
N/A N/A 144 144 144 144 N/A N/A N/A
16GA. 18GA. 20GA. 22GA.
N/A N/A N/A
20GA. 22GA.
26GA
.
N/A N/A
N/A
3.3
www.geniecompany.com 10-14
Miller Edge ME & MT series monitored edge sensors used in
combination with OPABTCGX.S Timer-Close Module or MillerEdge
Interface Module OPAKMEIGX.S. Miller Edge Wireless monitored edge sensor OPAKMMWE.S
ANY WIDTH
Residential Safe-T-Beams® P/N 37220R (GSTB-BX) and 38176R.S (includes ext. brkt’s)
Commercial Photoeye Kit P/N OPAKPE.S and OPAKPEN4GX.S (NEMA 4)
LISTED DEVICES
ALLOWABLE DOOR WIDTH
30 FEET
35 FEET
Monitored Retro-Refective Photoeye Kit P/N OPGAKRPEN4X.S
3.4
www.geniecompany.com 10-14
IMPORTANT
INSTALLATION INSTRUCTIONS
WARNING-
To reduce the risk of severe
injury or death:
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
Install only on a properly operating and balanced door. A door that is
operating improperly could cause severe injury. Have qualified service
personnel make repairs to cables, spring assemblies and other
hardware before installing the operator.
Remove all pull ropes and remove, or make inoperative, all locks
(unless mechanically and/or electronically interlocked to the power
unit) that are connected to the door before installing the operator.
Install the door operator at least 8 feet above the floor if the operator
has exposed moving parts.
Do not connect the door operator to the power source until
instructed to do so.
Locate the control station: (a) within sight of the door, (b) a minimum
of 5 feet above the floor so that small children cannot reach it, and
(c) away from all moving parts of the door.
Install the Entrapment Warning Placard next to the control station
and in a prominent location.
For products having a manual release, instruct the end user on the
operation of the manual release.
IMPORTANT
INSTRUCTIONS DINSTALLATION
AVERTISSEMENT-
Pour réduire les risques de
blessures graves ou de mort :
1)
LIRE ET RESPECTER TOUTES LES INSTRUCTIONS D'INSTALLATION.
2)
Installez uniquement sur une porte fonctionnant correctement et bien
équilibrée. Une porte qui fonctionne mal peut provoquer des blessures
graves. Demandez à un technicien qualifié d'effectuer les réparations
des câbles, des ressorts et de toute autre quincaillerie avant de
procéder à l'installation de l'opérateur.
Retirez toutes les cordes de traction ainsi que tous les verrous ou
rendez-les inopérants (à moins qu'ils ne soient mécaniquement et/ou
électroniquement interverrouillés à l'unité motrices) qui sont connectés
à la porte avant de procéderà l'installation de l'opérateur.
Installez l'opérateur de la porte à 2,4 m minimum au-dessus du sol
lorsque des pièces mobiles de l'opérateur sont exposées.
Ne pas raccorder l'opérateur de la porte à la source d’alimentation
avant que l'instruction ne soit donnée de le faire.
Installez la station de commande : (a) en vue de la porte, (b) à 1,5 m
minimum au-dessus du sol pour que les jeunes enfants ne puissent
pas l'atteindre, et (c) à l'écart de toutes les pièces mobiles de la porte.
Installez le poster d'avertissement de pincement à côté de la station de
commande à un endroit bien en vue.
Pour les produits ayant un déclenchement manuel, indiquez à l'utilisateur
comment déclencher manuellement.
3)
4)
5)
6)
7)
8)
1)
2)
3)
4)
5)
6)
7)
8)
Section 3: Critical Installation Information
4.1
Unless otherwise stated, these instructions will show right side mount installations.
Left side mount is opposite.
1) Insert four(4) 3/8"-16 x 1" carriage bolts into headplate. FIG. 1.
Threads to outside of plate.
Retain by pushing 4 speed nuts onto bolts.
2) Complete installation of door as instructed in door installation manual up to
"mounting of hood."
3) Make certain both headplates are at 90° to wall.
If not at 90°, use temporary external brace to hold in place.
4) Install hood and secure with hood mounting screws.
When hood is secure, remove temporary brace if used (in step3).
Leave door in FULL OPEN position.
5) Place 3/8" flat washers and 3/8"-16 keps nuts on 3/8" carriage bolts closest
to wall. .
Leave nuts flush with ends of bolts.
m the operator.orf draug niahc evomeR )6
Section 4: Installation
Mounting
www.geniecompany.com 10-14
Figure 1
3/8”-16 x 1”
CARRIAGE BOLT
SPEED
NUT
3/8”-16 KEPS NUT
WITH 3/8” FLAT WASHER
(NUT FLUSH WITH
END OF BOLT)
Mounting (continued)
7) Slide open ended slots of frame under flat washers installed in step 5. FIG. 2.
Locate other frame slots over remaining two(2) carriage bolts and bring frame
against headplate.
Put 3/8" washers and keps nuts on remaining bolts.
DO NOT fully tighten nuts.
Slide operator toward wall as far as slots allow. FIG. 3.
8) Place driven sprocket and key on door shaft and align with output sprocket
on operator. FIG. 3A.
Secure sprocket and key in place with set screws.
9) Wrap #41 roller chain around both sprockets and join with connecting link. FIG. 4 & 5.
Extra chain may need to be added depending on size of headplate.
Slide operator away from hood until drive chain is tensioned but not tight. FIG. 6.
Tighten mounting nuts.
Figure 2
Figure 5
Figure 4
Figure 6
4.2
TOWARD WALL
AS FAR AS
SLOTS WILL ALLOW
Figure 3
Figure 3A
90°
www.geniecompany.com 10-14
Manual Release
NOTE: In case of power failure, door can be operated manually.
The operator can be disconnected from door by pulling red pull rope attached to
Manual Release Arm to allow opening door. FIG. 7.
When door is in manual operation, limit switch setting is not affected.
Releasing pull rope will re-engage operator.
4.3
www.geniecompany.com 10-14
Figure 7
MANUAL RELEASE
ARM
RELEASE CORD
These instructions apply to either board. Although they perform different functions,
they mount in the same way.
2) Orient the module so mounting bracket tabs are to the left and wire
terminals are facing up.
3) Make desired wiring connections, in accordance with instruction manual
accompanying the module.
4) Insert module into the area indicated and slide front mounting tab into slot
on side panel of the enclosure. FIG. 9 & 10.
5) Adjust module so that it is level with the operator enclosure.
There is a mounting hole on side panel of enclosure which will line up
with hole in module mounting bracket.
Attach module by inserting self-tapping screw (provided in kit) through
module bracket and into hole in side panel. Do not overtighten.
6) Replace front panel.
Optional Timer-Close Module or Auxiliary Output Module
Figure 9
Figure 10
MOUNTING
BRACKET
TAB
Self tapping
screw
4.4
www.geniecompany.com 10-14
FIG. 8
dna erusolcne eht fo lenap tnorf morf swercs gnippat-fles )4( ruof evomeR )1
remove front panel to expose control circuits and allow for installation of
any optional accessory board.
to
Figure 8
Section 5: Wiring
5.1
www.geniecompany.com 10-14
WARNING
DO NOT apply power to operator until instructed to do so.
It is strongly recommended, and may be required by law
in some areas, that line voltage wiring be performed by
a qualified electrician.
Be sure that electrical power has been disconnected from
the input power wires being connected to the operator
prior to handling these wires. An appropriate lock-out/
tag-out procedure is recommended.
Line voltage wiring must meet all local building codes.
Make sure operator voltage, phase and frequency nameplate
ratings are identical to the job site line voltage ratings.
Input power wiring must be properly sized for the operators
amperage rating located on the nameplate.
To reduce the risk of electric shock, make sure the chassis of
this unit is properly grounded.
AVERTISSEMENT
NE PAS mettre sous tension tant que l'instruction n'est
pas donnée de le faire.
Il est fortement recommandé voire même exigé par la loi dans
certaines régions, de contacter un électricien qualifié pour
l'acheminement du fil électrique.
Assurez-vous que l'alimentation électrique a été déconnectée
des câbles d'alimentation d'entrée connectés à l'opérateur
avant de manipuler ces câbles. Une procédure de verrouillage/
étiquetage appropriée est recommandée.
Le câblage au secteur doit satisfaire à tous les codes de
construction locaux.
Assurez-vous que les valeurs nominales de la plaque
signalétique pour tension, phase et fréquence de l'opérateur
correspondent à celles des tensions de l'alimentation sur site.
La capacité d'entrée doit correspondre à la valeur nominale de
l'ampérage des opérateurs indiquée sur la plaque signalétique.
Pour réduire le risque de choc électrique, assurez-vous que le
châssis de l'unité est correctement mis à la terre.
1) Remove LINE VOLTAGE INPUT PLUG and install proper
fittings and 1/2”conduit.
2) Route proper LINE VOLTAGE wires into operator.
3) Locate LINE INPUT terminals on circuit board. Using
correct connectors, attach wires to LINE INPUTS, and GROUND
terminal.
Keep low voltage and line voltage wires separate.
Route all line voltage wires as shown.
Plug all unused conduit holes.
STB
ENAB
+ 4
VAC
EXT
IN LK
HOIST
IN LK
CAL
RUN
SET
CLR
SCROLL
SCROLL
Figure 1
Line Voltage Wiring Fig. 1
5.2
www.geniecompany.com 10-14
1) Connect all LOW VOLTAGE control circuit wires to this
side
of unit using 1/2” conduit or flexible convoluted
tubing.
Keep low voltage and line voltage wires separate.
Route all low voltage control wiring as shown. This
includes
all control circuit wires such as wall controls,
timers and single
button
input
devices
as
well
as
radio control and safety
circuit wiring.
Plug all unused conduit holes.
Low Voltage Control Wiring
Fig. 2
S
S B
S Y
SS B S B
STB
ENAB
+ 24
VAC
EXT
NTLK
HO ST
NTLK
CAL
RUN
SET
CLR
SCROLL
SCROLL
Figure 2
5.3
www.geniecompany.com 10-14
5.4
External Wire Diagram
See Appendix B for detailed description of terminals.
1-BTN
S TATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
MULTIPLE
3 BUTTON STATION
INSTALLATIONS
REQUIRE THE STOP
BUTTON TO BE
WIRED IN SERIES
See Fig. 5 pg. 5.5
*
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
THRU-BEAM PHOTOCELLS
2-WIRE MONITORED SENSING EDGE SWITCH
+
-
+
-
PWR
20-40 VDC @ 315mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
S TOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
S TATION
*
BLUE
ORANGE
YELLOW
Located inside
Electrical Box
MONITORED EDGE
INTERFACE MODULE
www.geniecompany.com 10-14
Wall Control
5.5
www.geniecompany.com 10-14
1) For a single 3 - button installation, make connections as
shown in Fig. 3.
OPEN
CLOSE
STOP
3-BUTTON
STATION
CONTROL SIGNAL TERMINAL STRIP
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
OPEN CLOSE STOP GND
Figure 3
Figure 3B
WARNING:
Before momentary contact control can
be used on the CLOSE button, a monitored external reversing device
such as a photocell system or sensing edge switch must be used.
See pages 5.7-5.9 for installation of entrapment protection devices.
AVERTISSEMENT:
Avant d'utiliser la
commande à contact momentané sur le bouton FERMETURE, un
dispositif d'inversion externe surveillée tel qu'un système de
cellule photoélectrique ou un commutateur de détection de bord
doit être utilisé. Voir l'installation des dispositifs de protection
contre le coincement en pages 5.7-5.9.
Entrapment
Warning Placard
Figure 3A
WARNING:
Wall Control(s) must be located so that the door is within sight of
the user and is far enough from the door, or postioned such that
the user is prevented from coming in contact with the door while
operating controls.
Attach the Warning placard adjacent to the Wall Control. Fig. 3A.
AVERTISSEMENT:
La ou les commandes murales doivent être situées de telle sorte que l'utilisateur
puisse voir la porte et positionnées de telle sorte que l'utilisateur
ne puisse pas entrer en contact avec la porte lorsqu'il se sert des commandes.
Fixez le poster d'avertissement à côté de la commande murale. Fig. 3A
Attach the Caution label adjacent to the Wall Control.
Fig. 3B.
Fixer l'étiquette de mise en garde (Attention) à côté de la
commande murale.
Fig. 3B.
CAUTION
NOT FOR RESIDENTIAL USE
To prevent the motor protector from tripping,
do not exceed 4 door operations per hour.
For light-duty use ONLY.
ATTENTION
NON DESTINÉ POUR USAGE RÉSIDENTIEL.
Pour parer au déclenchement du système de
protection du moteur, NE PAS dépasser 4 opérations
de la porte à l'heure.
Pour service simple UNIQUEMENT.
5.6
www.geniecompany.com 10-14
2) For single button accessory controls, make connections as
shown in Fig. 4.
3) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
NOTE: If an External STOP button is NOT being installed, a jumper wire
must be installed between the “STOP” AND “GND” terminals as shown.
NOTE: Long Distance Relay Kit wiring is not required for long
distance control runs and should not be used
Wall Control (cont.)
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
3-BUTTON
STATION
CONTROL SIGNAL TERMINAL STRIP
OPEN CLOSE STOP GND
3-BUTTON
STATION
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
Figure 4
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
OPEN/CLOSE
PULL SWITCH
CONTROL SIGNAL TERMINAL STRIP
ODC
STB
GNDSTOP 1-BTN
Figure 5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Genie GCL-GCX Operator / Installation Manual

Catégorie
Porte de garage
Taper
Operator / Installation Manual

dans d''autres langues