DuraVent DuraChimney II Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

1. Adjust the worm gear clamp (see Table 1 for range of adjustability) so it can fit over the outer diameter of the
insulated chimney length. Insert the Dikapt inside of the insulated chimney length. Place the retainer loop and
the worm gear clamp around the outside of the insulated chimney length. See Figure 1. Make sure the storm
collar of the Dikapt is fully seated flush to the top of the chimney male end.
2. Tighten securely the worm gear clamp around the insulated chimney length. The worm gear clamp can be
moved up or down within the retainer loop.
ATTENTION: The Dikapt should be inspected regularly to determine if a creosote or soot build-up has occured:
if a significant layer of creosote has accumulated (3mm / 1/8”), it needs to be removed to reduce the risk of a
chimney fire. Have your chimney and Dikapt inspected and cleaned by a qualified chimney sweep.
Installation Instructions
Dikapt
READ INSTRUCTIONS CAREFULLY BEFORE STARTING THE PROJECT. REMEMBER THAT SAFETY COMES FIRST. OUR CHIMNEY
SYSTEMS ARE DESIGNED FOR INSTALLATION BY A QUALIFIED PERSON IN ACCORDANCE WITH LOCAL BUILDING CODES.
WEAR CUT RESISTANT GLOVES WHILE HANDLING
METAL PARTS TO AVOID PERSONAL INJURY. SHARP
EDGES OR PROJECTIONS CAN CUT YOU.
Tested to: UL 103 HT, ULC-629, ULC-604
LISTED A218
CAUTION:
1. Ajuster le collier de serrage à vis (voir le tableau 1 pour la gamme de réglage) pour qu’il puisse s’adapter au
diamètre extérieur de la longueur de cheminée isolée. Insérer le Dikapt à l’intérieur de la longueur de cheminée
isolée. Positionner la boucle de retenue et le collier de serrage à vis autour de l’extérieur de la longueur de
cheminée isolée. Voir schéma 1. S’assurez que le collet de solin du Dikapt est bien calé sur le dessus de
l’extrémité mâle de la cheminée.
2. Serrez le collier de serrage à vis contre l’extérieur de la cheminée. Le collier de serrage à vis peut être déplacée
vers le haut ou vers le bas à l’intéieur de la boucle de retenue.
REMARQUE: Le Dikapt devrait être inspecté régulièrement afin de déterniner si une accumulation de créosote
ou de suie s’est produit. Si une couche significative de créosote s’est accumulée (3mm ou plus), elle doit être
éliminée afin de réduire les risques de feu de cheminée. Faites inspecter, nettoyer votre cheminée et le Dikapt
par un ramoneur qualifié.
VEUILLEZ LIRE LES DIRECTIVES ATTENTIVEMENT AVANT DE COMMENCER LE PROJET. SOUVENEZ-VOUS QUE LA PRIORITÉ EST
LA SÉCURITÉ. NOS SYSTÈMES DE CHEMINÉE ONT ÉTÉ CONÇUS POUR ÊTRE INSTALLÉS PAR DES PERSONNES QUALIFIÉES,
EN CONFORMITÉ AUX CODES LOCAUX DU BÂTIMENT.
Instructions d’installation
Dikapt
PORTEZ TOUJOURS DES GANTS DE
SÉCURITÉ LORSQUE VOUS MANIPULEZ DES
PIÈCES DE MÉTAL À REBORD COUPANTS
Testé: UL 103 HT, ULC-629, ULC-604
Homologué A218
MISE EN GARDE:
UL Listed Models:
Selkirk Models: UT, GT, ST, CF, FC, SC, JSC, SPR, TLC, SC-1, JM, ALT
Duravent Models: DP, DT, DCA
Modèles homologués avec UL:
Modèles de Selkirk: UT, GT, ST, CF, FC, JSC, SPR, TLC, SC-1, JM, ALT
Modèles de Duravent: DP, DT, DCA
DIKAPT
DIKAPT FLUE /
TUYAU DIKAPT
INSULATED CHIMNEY /
CHEMINÉE ISOLÉE
DIKAPT INSTALLED WITH INSULATED CHIMNEY / INSTALLATION AVEC CHEMINÉE ISOLÉE
SELKIRK CANADA INC.
P.O. Box 526, Depot 1,
Hamilton, ON L8L 7X6
Tel: 888-735-5475
www.selkirkcorp.ca
SELKIRK CORPORATION
4460 44th Street, S.E.,
Suite F
Grand Rapids, MI 49512
Tel: 800-992-8368
www.selkirkcorp.com
DURAVENT GROUP ©2024 Dikapt All Rights Reserved/Tout droit réservé FDK_3007739 01/19/2024 Printed inCanada / Imprimé au Canada
HART & COOLEY LLC
4460 44th Street, S.E.,
Suite F
Grand Rapids, MI 49512
Tel: 800-565-8200
www.hartandcooley.com
DURAVENT INC.
877 Cotting Court
Vacaville, CA 95688
Tel: 800-835-4429
www.duravent.com
STORM COLLAR /
COLLET DE SOLIN
WORM GEAR
CLAMP /
COLLIER DE
SERRAGE À VIS
RETAINER LOOP /
BOUCLE DE RETENUE
FIGURE / SCHÉMA 1
TABLE 1 - ADJUSTABILITY OF WORM GEAR CLAMP / RÉGLAGE DU COLLIER DE SERRAGE À VIS
CHIMNEY / CHEMINÉE Ø
10” X 1”
5” X 1”, 6” X 1”, 6” X 2”, 7” X 1”, 7” X 2”
8” X 1”, 8” X 2”
11.5” TO 13.5” / 11,5 PO À 13,5 PO
2” TO 12.25” / 2 PO À 12,25 PO
2” TO 16” / 2 PO À 16 PO
ADJUSTMENT RANGE / GAMME DE RÉGLAGE
HART & COOLEY LLC
4460 44th Street, S.E.,
Suite F
Grand Rapids, MI 49512
Tel: 800-423-4270
www.ameri-vent.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DuraVent DuraChimney II Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues