Electrical Shock Hazard
Plug into a grounded 3 prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
If codes permit and a separate
grounding wire is used, it is
recommended
that a qualified
electrician determine that the
grounding
path is
adequate.
Check with a qualified electrician if you are
not sure the air conditioner is properly
grounded.
A three-wire, single-phase, 60-HZ, AC-only,
electrical supply is required on a separate
circuit. A 15-amp time-delay fuse or circuit
breaker is required. Copper wire (#14
gauge) is required. The fuse size must not
exceed the circuit rating specified on the
model and serial label.
The model and serial ktbel (A) is located
behind the front panel above the coil area.
Recommended grounding
method
For your personal safety, this air conditioner
must be grounded. This air conditioner is
equipped with a power supply cord having a
3-prong grounding plug. To minimize
possible shock hazard, the cord must be
plugged into a mating, 3-prong grounding-
type wall receptacle, grounded in accordance
with all local codes and ordinances. If a
mating wall receptacle is not available, it is
the customer’s responsibility to have a
properly grounded, 3-prong wall receptacle
installed by a licensed installer.
It is the customer’s responsibility:
. To contact a qualified electrical installer.
l
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANWNFPA 70 - latest
edition*, and all local codes and
ordinances.
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Specific electrical requirements are listed in
the chart. Follow the requirements for the
type of plug on the power supply cord.
Wiring requirements
B. 3-prong grounding plug
C. 3-prong grounding-type wall receptacle
D. grounding prong
E. power supply cord
l
115~volt (103.5 min. 126.5 max.)
l
7.5-amp rating or less - a double outlet
is acceptable.
l
7.6- through 12-amp ratings - use only a
single outlet and a separate circuit.
. 14-gauge copper wiring
Peligro de Choque El6ctrico
Conecte a un contact0 de pared de
conexi6n a tierra de 3 terminales.
No quite el terminal de conexi6n a
tierra.
No use un adaptador.
No use un cable el6ctrico de
extensi6n.
No seguir estas instrucciones
puede ocasionar la muette,
incendio o choque electrico.
Si 10s c6digos lo permiten y se utiliza
un
alambre de puesta a tierra separado,
se recomienda que
un
electricista
calitkado determine si la trayectoria de
la puesta a tierra es adecuada.
Consulte con un electricista caliEcado para
asegurarse de que el acondicionador de aire
esd debidamente puesto a tierra.
Se requiere un suministro elCctric0
monof%sico de tres alambres, de 60 Hz, ~610
de CA, en un circuit0 separado. Se requiere
un fusible de retard0 de 15 amperes o un
disyuntor. Use solamente alambre de cobre
(cahbre #14). El tamafio de1 fusible no debe
exceder la clasiEcaci6n de1 circuit0
especificada en la etiqueta de modelo y serie.
La etiqueta de modelo y serie (A) se
encuentra detrb de1 panel delantero, sobre el
irea de1 serpentin.
M6todo recomendado para
la puesta a tierra
Para su seguridad personal, este
acondicionador de aire debe ser puesto a
tierra. Este acondicionador de aire esti
equipado con un cord6n elCctrico provisto de
un enchufe con clavija tripolar de conexidn a
tierra. Para reducir a un mfnimo el riesgo
posible de un choque elCctrico, el cord6n
debe enchufarse en un tomacorriente mural
para clavija con 3 terminales que coincidan
con 10s poles de la clavija, puesto a tierra de
acuerdo con todos 10s cddigos y reglamentos
locales. Si no se dispone de un tomacorriente
para clavija tripolar, es responsabilidad de1
cliente hater instalar un tomacorriente para
clavija con tres terminales debidamente
puesto a tierra por un electricista con
licencia.
Es responsabilidad de1 cliente:
l
Llamar a un instalador e!Cctrico calificado.
. Asegurarse de que la instalacibn elCctrica
seaadecuadayestChechadeacuerdocon
el C6digo National de Energfa, ANSVNFPA
70, liltima edici6n*, y todos 10s c6digos y
reglamentos locales.
Pueden obtenerse copias de las normas selaladas
del:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Los requerimientos elkctricos especificos se
indican en la tabla. Siga 10s requerimientos
para el tipo de enchufe en el cord6n de
alimentaci6n elCctrica.
Requerimientos de cableado
B. clavija tripolar de conexi6n a tierra
C. tomacorriente mural para clavija con
3 terminales puesto a tierra
D. terminal de conexi6n a tierra
E. cord6n de alimentaci6n
l
115 voltios (103,5 min. - 126,5 ma,)
l
clasificaci6n de 7,5 amperes o menos - es
aceptable un tomacorriente doble.
l
clasificaciones de 7,6 a 12 amperes - use
linicdmente un solo tomacorriente y un
circuit0 separado.
l
cableado de cobre de calibre 14
Risque de choc 6lectrique
Brancher I’appareil uniquement sur
une prise d 3 alv6oles reli6e & la
terre.
Ne pas enlever la broche de liaison
B la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un cgble de
rallonge.
Le non-respect de ces instructions
peut causer un d&&s, un incendie
ou un choc 6lectrique.
Si
on
utilise un conducteur distinct
de
liaison ?t la terre lorsque le code local
le permet, il est recommandk qu’un
klectricien qualifik vkrifie la qualitk de
la liaison ?t la terre.
En cas de doute quant B la qualit de la
liaison a la terre de cet appareil, contacter
un Clectricien qualifiC.
L’appareil doit etre aliment& par un circuit
indipendant 2 3 Els (monophase, 60 Hz, CA
seulement). Le circuit doit @tre protkge par
un fusible ou un disjoncteur temporiG 15 A.
Utiliser du fil de cuivre de cdlibre 14. Le
fusible ne doit pas dCpa.sser le calibre du
circuit spCcifiC sur la plaque signalCtique.
On trouve le numCro de modele et le
num&o de s&ie sur ki plaque signak?tique
(A), derriere le panneau avant au-dessus de
I’espxe des serpentins.
Methode de liaison 21 la
terre recommandke
Pour kd s&rite personneue des utisateurs, il
hut que cet appareil soit reliC a la terre. Cet
appareil est aliment6 par un cordon Clectrique
comportant une fiche de branchement g 3
broches, pour liaison a la ten-e. Pour
minimiser le risque de choc Clectrique,
brancher le cordon d’alimentation sur une
prise de courant murale compatible P 3
aMoles, reli& 2 la terre conformCment aux
prescriptions de tous les codes et rcglemenk
locaux en vigueur. Si une prise de courant
compatible avec la fiche de branchement n’est
pas disponible, c’est au client qu’incombe
I’obligation de faire installer une prise de
courant murale ?t 3 a&oles convenablement
reliCe :d la terre, par un Clectricien qualit%.
C’est au client qu’incombe la resp0nsabilit.G de :
l
Contacter un Clectricien quaMX
l
Veiller g ce que I’installation Clectrique soit
r&l&e adkquatement et en conformit avec
les prescriptions du Code national des
installations Bectriques, ANWNFPA 70
(dernikre Cdition*), et de tous les codes et
r@lements locaux en vigueur.
On peut obtenir des evemplaires des normes
mentionntes aux adresses suivantes :
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Le tableau ci-dessous indique les
CaractCristiques Clectriques sp&&ques B
respecter. Respecter les exigences indiquees
pour le type de fiche de branchement du
cordon d’alirnentation.
SpCcitkations
B. Fiche de branchement h 3 broches
C. Prise de courant murale g 3 alv6oles,
reliCe B la terre
D. Broche de liaison B la terre
E. Cordon klectrique
l
115V (103,5Vmin - 126,5Vmax.)
l
Demande de 7,5 A ou mains - une prise de
courant double est acceptable.
l
Demande de 7,6 A ‘d 12 A - utiliser une prism
de courant unique et un circuit independant
l
cgb.blage de calibre 14 (cuivre)