NAPOLEON GDI-30NSB Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur
FRENCH
PG. 29
W415-2343 / A / 11.12.19
ADD MANUAL TITLE
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
NATURAL GAS MODELS:
PROPANE GAS MODELS:
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
CSA /
INTERTEK
LOGO
SAFETY INFORMATION
- Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be
performed by a qualifi ed installer, service
agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
WARNING
!
ENGLISH
$10.00
FOR INDOOR USE ONLY
IF INSTALLATION + OPERATION, ADD SERIAL
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD “PLACE
BARCODE LABEL ON THE OWNER’S MANUAL”
INSTALLATION AND
OPERATION MANUAL
GDI-30N
GDI-30P
Roxbury™ Series
(GDI-30 illustrated)
SAFETY BARRIER
SHOWN WITH GIFK6 FLASHING & FPGI30-K FACEPLATE
This appliance is hot when operated and
can cause severe burns if contacted.
Any changes or alterations to this
appliance or its controls can be
dangerous and is prohibited.
Do not operate appliance before reading and
understanding operating instructions. Failure
to operate appliance according to operating
instructions could cause fi re or injury.
Ensure the glass door is opened or removed
when lighting the pilot for the fi rst time and
when the gas supply has run out.
Risk of fi re or asphyxiation, do not operate
appliance with fi xed glass removed and never
obstruct the front opening of the appliance.
Do not connect 110 volts to the control valve,
with the exception of models; GSST8 and
GT8.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves, protective footwear, and safety glasses during
installation. Sheet metal edges may be sharp.
Do not burn wood or other materials in this appliance.
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing
and operating the appliance.
High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at
test pressures above 1/2 psig. Close the manual shut-off valve before pressure testing gas line at test
pressures equal to or less than 1/2 psig (35mb).
The appliance must not be operated at temperatures below freezing (32°F / 0°C). Allow the appliance
to warm to above freezing prior to operation, with the exception of models; GSS36, GSS42; these
appliances are suitable for 0°F / -18°C.
Children and adults should be alerted to hazards of high surface temperature and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the
appliance. Toddlers, young children and others may be susceptible to accidental contact
burns. A physical barrier is recommended if there are at risk individuals in the house. To
restrict access to an appliance or stove, install an adjustable safety gate to keep toddlers,
young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other fl ammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from
furniture and draperies.
Furniture or other objects must be kept a minimum of 4 feet (1.22m) away from the front of the appliance.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
Even after the appliance is off, it will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen, guard or barrier removed for servicing the appliance, must be replaced prior
to operating the appliance.
It is imperative that the control compartments, burners and circulating blower and its passageway in the
appliance and venting system are kept clean. The appliance and its venting system should be inspected
before use and at least annually by a qualifi ed service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and
free from combustible materials, gasoline and other fl ammable vapors and liquids.
If the appliance shuts off, do not re-light until you provide fresh air. If appliance keeps shutting off, have it
serviced. Keep burner and control compartment clean.
Under no circumstances should this appliance be modifi ed.
Do not allow wind or fans to blow directly into the appliance. Avoid any drafts that alter burner fl ame
patterns.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
shall be installed for the protection of children and other
at-risk individuals.
!
WARNING
W415-2343 / A / 11.12.19
EN
2
safety information
!
WARNING
Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this
appliance.
This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning
appliance.
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system and any gas control which has
been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualifi ed service person, if equipped.
Do not strike or slam shut the appliance glass door, if equipped.
Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
Carbon or soot should not occur in a vent free appliance as it can distribute into the living area of your
home. If you notice any signs of carbon or soot, immediately turn off your appliance and arrange to have
it serviced by a qualifi ed technician before operating it again.
If equipped, the screen must be in place (closed) when the appliance is in operation.
When equipped with pressure relief doors, they must be kept closed while the appliance is operating
to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of
the exhaust escaping through these openings can also cause the surrounding combustible materials to
overheat and catch fi re.
Carbon monoxide poisoning may lead to death; early signs of carbon monoxide poisoning resemble the
u, with headache, dizziness and/or nausea. If you have these signs, the appliance may not be working
properly. Get fresh air at once! Have appliance serviced. Some people; pregnant women, persons with
heart or lung disease, anemia, those under the infl uence of alcohol, those at high altitudes are more
affected by carbon monoxide than others. Failure to keep the primary air opening(s) of the burner(s) clean
may result in sooting and property damage.
As with any combustion appliance, we recommend having your appliance regularly inspected and
serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and
your family against Carbon Monoxide (not applicable for outdoor appliances).
Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a TV or other electronic components.
For appliances equipped with a safety barrier; if the barrier becomes damaged, the barrier
shall be replaced with the manufacturer’s barrier for this appliance.
Installation and repair should be done by a qualifi ed service person. It is imperative that control
compartments, burners and circulating air passageways of the appliance be kept clean.
For outdoor products only: this appliance must not be installed indoors or within any structure that
prevents or inhibits the exhaust gases from dissipating in the outside atmosphere.
If applicable, the millivolt version of this appliance uses and requires a fast acting thermocouple. Replace
only with a fast acting thermocouple supplied by Wolf Steel Ltd.
!
WARNING
!
Disconnect the appliance main gas valve/control
from the supply piping when pressure testing that
system at pressures in excess of 1/2 psi (3.5 kPa).
Isolate the appliance with it’s shut off valve during
any pressure testing of the supply piping at
pressures equal to or less than 1/2 psi (3.5 kPa).
FIRE RISK HAZARD / DELAYED IGNITION
High supply pressure will damage the valve / controls.
Add California Prop 65 warning
!
WARNING:
This product can expose you to chemicals including lead and lead compounds,
which are known to the State of California to cause cancer, and chemicals including carbon
monoxide, which are known to the State of California to cause birth defects or other reproduc-
tive harm. For more information, go to www.P65Warnings.ca.gov.
EN
W415-2343 / A / 11.12.19
3
safety information
1.0 general information 5
1.1 rates & effi ciencies 5
1.2 rating plate information 7
1.3 dimensions 7
1.4 minimum clearance to combustibles 7
2.0 installation 8
2.1 levelling the appliance 8
2.2 chimney connection 9
2.3 gas installation 10
2.4 optional wall switch 10
3.0 finishing 11
3.1 minimum mantel clearances 11
3.2 safety screen removal and installation 12
3.3 door removal and installation 13
3.4 grate installation 13
3.5 log placement 14
3.6 optional charcoal embers 15
3.7 glowing embers 15
3.8 logo placement 15
4.0 blower replacement 16
5.0 operation 17
6.0 adjustments 18
6.1 pilot burner adjustment 18
6.2 venturi adjustment 18
6.3 fl ame characteristics 18
7.0 maintenance 19
7.1 annual maintenance 20
7.2 care of glass 20
7.3 door glass replacement 21
8.0 replacement parts 21
8.1 overview 22
8.2 valve train assembly 23
9.0 accessories 24
10.0 troubleshooting 25
11.0 warranty 27
W415-2343 / A / 11.12.19
EN
4
table of contents
The information throughout this manual is believed to be correct at the time of printing. Wolf Steel
Ltd. reserves the right to change or modify any information within this manual at any time without
notice. Changes, other than editorial are denoted by a vertical line in the margin.
note:
EN
W415-2343 / A / 11.12.19
5
table of contents
1.0 general information
Installer, please fi ll out the following information:
Customer: ________________________________________________________________________
Address: ________________________________________________________________________
Date of Installation: ________________________________________________________________________
Location of Appliance: ________________________________________________________________________
Installer: ________________________________________________________________________
Dealer/Distributor contact number: ________________________________________________________________________
Serial #: ________________________________________________________________________
Model:
Natural Gas: GDI-30N Propane: GDI-30P
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation in
a mobile home that is permanently positioned on its site and fuelled with natural gas.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appli-
ance and must be installed.
1.1 rates & effi ciencies
GDI-30
NG P
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 24,500
Max. Output (BTU/HR) 20,825
Min. Inlet Gas Supply Pressure 4.5" (11mb) Water Column 11" (27mb) Water Column
Max. Inlet Gas Supply Pressure 7"* (17mb) Water Column 13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) Water Column 10" (25mb) Water Column
* Maximum inlet pressure not to exceed 13".
W415-2343 / A / 11.12.19
EN
6
table of contents
!
WARNING
Always light the pilot - whether for the fi rst time or if the gas supply has run out - with the glass door
opened or removed.
Provide adequate clearance for servicing and operating the appliance.
Provide adequate ventilation.
Never obstruct the front opening of the appliance.
Objects placed in front of the appliance must be kept a minimum of 48” (121.9cm) from the front face of
the appliance.
Surfaces around and especially above the appliance can become hot. Avoid contact when appliance is
operating.
Fire risk. Explosion hazard.
Use only Wolf Steel approved optional accessories and replacement parts with this appliance using non-
listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could result
in a safety hazard and will void the warranty and certifi cation.
THIS GAS APPLIANCE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for
example in the state of Massachusetts:
This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of
Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of an appliance insert or gas
log.
The appliance off valve must be a “T” handle gas cock.
The fl exible connector must not be longer than 36 inches (0.9m).
A carbon monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed
combustion product.
The installation must conform with local codes or, in absence of local
codes, the National Gas and Propane Installation Code CSA B149.1
in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54
in the United States. Suitable for mobile home installation if installed
in accordance with the current standard CAN/CSA Z240MH Series,
for gas equipped mobile homes, in Canada or ANSI Z223.1 and
NFPA 54 in the United States.
The appliance and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures in excess of 1/2 psig (35 mb).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (35 mb). When installed
with a blower or fan, the junction box must be electrically connected and grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI / NFPA 70 National
Electric Code in the United States. In the case where the blower is equipped with a power cord, it must be connected into a
properly grounded receptacle. The grounding prong must not be removed from the cord plug.
The following does not apply to inserts; as long as the required clearance to combustibles is maintained, the most desirable
and benefi cial location for an appliance is in the center of a building, thereby allowing the most effi cient use of the heat
created. The location of windows, doors and, the traffi c fl ow in the room where the appliance is to be located should be
considered. If possible, you should choose a location where the vent will pass through the house without cutting a fl oor or
roof joist. If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood fl ooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth, unless otherwise tested.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
EN
W415-2343 / A / 11.12.19
7
table of contents
1.2 rating plate information
23 1/8"
587mm
21 3/4"
552mm
ø
3"
76mm
13 3/4"
349mm
5 1/4"
133mm
1 3/8"
35mm
18 3/4"
476mm
13 3/4"
349mm
11 1/8"
283mm
30 1/16"
764mm
19 5/8"
499mm
27 1/2"
692mm
GAS INLET
This appliance must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 22" (559mm) WIDTH 28" (711mm) DEPTH 18" (457mm)
The minimum allowable chimney fl ue size is 6" (152mm) round.
The minimum distance, from the bottom of a combustible mantle projecting 3" (76mm) maximum from the wall to
the top of the louvre opening, is 12" (305mm).
1.3 dimensions
Certified to Canadian and American National Standards: CSA 2.22-XXXX / ANSI Z21.50-XXXX for Vented Decorative Gas Appliances
Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-XXXX / ANSI Z21.50-XXXX pour les Appareils à gaz décoratif à évacuation
Direct vent, vented gas fireplaces. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the current
standard CAN / CSA Z240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part
3280. When this US Standard is not applicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliance
must be installed in accordance with local codes, if any; if none, follow the current ANSI Z223.1 or CSA B149. For use with barrier WXXX-XXXX. Follow installation instructions.
Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installation
conforme aux exigences de la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280,
Manufactured Home Construction and Safety Standard. Dans le cas ou cette norme d’États-Unis n’est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for Manufactured
Home Installations, Sites and Communities. Installer l’appareil selon les codes ou règlements locaux ou, en l’absence de tels règlements, selon les codes d’installation ANSI Z223.1 ou
CSA B149 en vigueur. Utiliser uniquement avec l’écran WXXX-XXXX. Suivre les instructions d’installation.
9700539 (WSL) 4001658 (NAC) 4001657 (NGZ) 4001659 (WUSA)
WOLF STEEL LTD. 24 Napoleon Road, Barrie, ON, L4M 0G8 Canada
XXXX XXXX XXXX XXXX
MODEL / MODÈLE
Altitude
Input
Reduced Input
P4
Élévation
Alimentation
Alimentation Réduite
P4
Manifold Pressure: 3.5” w.c. (NG)
Minimum Supply Pressure: 4.5” w.c. (NG)
Maximum Supply Pressure: 7”* w.c. (NG)
Pression au Collecteur: 3,5” d’une colonne d’eau (GN)
Pression d’Alimentation Min.: 4,5” d’une colonne d’eau (GN)
Pression d’Alimentation Max.: 7” ** d’une colonne d’eau (GN)
** Maximum inlet pressure not to exceed 13”.
Manifold Pressure: 10” w.c. (P)
Minimum Supply Pressure: 11” w.c. (P)
Maximum Supply Pressure: 13”* w.c. (P)
Pression au Collecteur: 10” d’une colonne d’eau (P)
Pression d’Alimentation Min.: 11” d’une colonne d’eau (P)
Pression d’Alimentation Max.: 13” * d’une colonne d’eau (P)
** Pression d’alimentation maximale ne devait pas dépasser 13”.
0-XXXXft (0-XXXXm)
Minimum clearance to combustible materials:
Top, sides & back: per standoff spacers for framing and finishing
materials. For non-combustible framing and finishing materials,
see installation manual.
Top X”
Floor X”
Sides X”
Back X”
Vent top X”
Vent sides & bottom X”
Recessed depth X”
*** Mantel X” from appliance opening
Dégagements minimaux des matériaux combustibles:
Dessus, côtés et arrière: selon les espaceurs de dégagements
pour les matériaux d’ossature selon le manuel du propriétaire
pour les matériaux de finition.
Dessus X”
Plancher X“
Côtés X”
Arrière X“
Dessus du conduit d’évent X”
Côtés et dessous du conduit d’évent X”
Profondeur d’encastré une face X”
*** Tablette X” de l’ouverture de l’appareil
WARNING: Do not add any material to the appliance which will come in contact with the
flames, other than that supplied by the manufacturer with the appliance.
AVERTISSEMENT: N’ajoutez pas à cet appareil aucun matériau devant entretien
contact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.
*** Maximum horizontal extension:
X”. See installation manual for
greater extensions, minimum vent
lengths and maximum vent lengths.
*** L’extension horizontale maximale: X”.
Référez au manuel d’installation pour des
extensions plus grandes, les longueurs
d’évacuation minimaux et maximum.
The appliance must be vented using the appropriate Napoleon vent kits. See installation
manual for venting specifications. Proper reinstallation and resealing is necessary after servicing
the vent-air intake system.
L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au
manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et
resceller l’évacuation après avoir executer l’entretien du système de prise d’air.
Serial Number / N° de Série:
W385-XXXX
REFERENCE# 161746
XXXX
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF
HEAT, NOT INTENDED FOR USE AS A HEATING
APPLIANCE, NOT FOR USE WITH SOLID FUEL.
APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N’EST PAS
UNE SOURCE DE CHALEUR; N’EST PAS DESTINÉ À ÈTRE
UTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NE
CONVIENT PAS AUX COMBUSTIBLES SOLIDES.
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE
CERTIFIÉES AVEC L’APPAREIL.
XX,XXX XX,XXX
XX,XXX XX,XXX
For natural gas when equipped with No. XX drill size orifice.
For propane when equipped with No. XX drill size orifice.
Convient au gaz naturel quand l’appareil est muni d’un injecteur de diamètre no. XX.
Convient au propane quand l’appareil est muni d’un injecteur de diamètre no. XX.
Electrical rating: 115V, 60HZ. Less than 12 amperes.
Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.
XX.X% XX.X%
XXXX XXXX XXXX XXXX
SAMPLE
pliance ance
ructions.uctions.
installation stallation
4 CFR, Part 3280, art 3280,
afety Criteria for Manufactured Manufactu
es d’installation
AN
S
I Z22
3
.1
ou
Z223.1 ou
É
l
é
v
a
ti
o
n
Élévatio
m
nt
t
n
Alim
e
nt
a
ti
o
n R
édu
it
eAlimentation Réduite
P
4
P4
GN)N)
’eau (GN)(GN)
Ma
nif
o
l
d
Pr
essu
r
e
:
fold Pressure:
1
0” w.c.
(
P
)w.c. (P)
Minimum
S
upply Pressure:
Minimum Supply Pressure:
1
1” w.c.
(
P
)11” w.c. (P)
M
aximum Su
pp
l
y
Pressure:
Maximum Supply Pressure:
1
3”* w.c.
(
P
)13”* w.c. (P)
Pression au
C
ollecteur:
sion au Collecteu
10” d’une colonne d’eau
(
P
)0” d’une colonne d’eau (P)
P
r
essio
n
d’Ali
m
e
nt
a
t
io
n
Mi
n.:
Alimentation Min.:
11” d’une colonne d’eau
(
P
)” d’une colonne d’eau (P)
P
r
essio
n
d’Ali
m
e
nt
a
t
io
n
Ma
x.:
Pression d’Alimentation Max.:
1
3” * d’une colonne d’eau
(
P
)13” * d’une colonne d’ea
** Pression d’alimentation maximale ne devait pas dépasser 13”.** Pression d’alimentation maximale ne devait pas dépasser
erials:
ers for framing and finishing s for framing and finishing
framing and finishing materials, framing and finishing materials,
peningning
Dégagements minimaux des matériaux combustiDégagements minimaux des matériaux combus
Dessus, côtés et arrière: selon les espaceurs de dégDessus, côtés et arrière: selon les espaceurs
pour les matériaux d’ossature selon le manueour les matériaux d’ossature selon le man
pour les
l extension: l extension:
ual for al for
um vent
m vent
lengths.
R
NTED DECORATIVE GAS APPLIANCE: NOT ADECORATIVE GAS APPLIANCE: NOT A
HEAT, NOT INTENDED FOR USE AS
HEAT, NOT INTENDED FOR USE AS
APPLIANCE, NOT FOR USE WITAPPLIANCE, NOT FOR USE W
APPAREIL À GAZ DÉCORATIF À ÉVACPPAREIL À GAZ DÉCORATIF À ÉVA
UNE SOURCE DE CHALEUR; NUNE SOURCE DE CHALEUR
UTILISÉ COMME UNUTILISÉ COMME U
CONVIENVIE
FOR USE WITH GFO
POU
L
XX
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
The rating plate must remain with the appliance at all times. It must not be removed.
note:
1.4 minimum clearance to combustibles
W415-2343 / A / 11.12.19
EN
8
2.0 installation
2.1 levelling the appliance
Move the appliance close to its fi nal position inside the wood-burning appliance. This appliance is equipped with
4 levelling screws located in the four inside corners beneath the log support. Level using the levelling screws to
eliminate rocking or excessive noise when the fan is in operation. Once the appliance is level, move it partially into
place within the appliance to allow for all connections to be made. It is not practical to level the appliance once
it has been installed. Determine the required depth prior to installing the appliance and adjust the four levelling
screws accordingly.
!
WARNING
Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance.
Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning
appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any
repair work done by a qualifi ed person before installing the insert. Remove the existing appliance damper or lock
into an open position.
Using screws, attach the appliance warning tag to the inside
of the fi rebox of the appliance into which the insert is being
installed.
The sheet-metal parts of the appliance, in which the gas
appliance insert is to be installed, must not be cut.
If the wood-burning factory-built appliance has no gas access
hole(s) provided, an access hole of 1½ inch (38.1mm) or less
may be drilled through the lower sides or bottom of the appliance in a proper workman like manner. This access
hole must be plugged with non-combustible insulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fi t properly.
The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing appliance
before installing the gas appliance insert.
Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners.
The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc. but
these parts are not to be applied so as to have an airtight seal.
W385-0199
W385-0199_B
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D’ETRE UTILISE SEULEMENT
COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT
ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES
AYANT JURIDICTION.
ADVERTENCIA: ESTA CHIMENEA SE REMODELÓ PARA USARSE SOLO CON UNA
INSERCIÓN DE CHIMENEA A GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES
SÓLIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LA AUTORI-
DAD JURISDICCIONAL LA HAYA VUELTO A APROBAR.
EN
W415-2343 / A / 11.12.19
9
installation
While the liners must be continuous from the appliance to the chimney cap, to achieve the needed length, they may
be coupled, using an approved coupler.
We recommend that exhaust vents that pass through unheated spaces, such as tall
exterior chimneys, be wrapped in a protective sleeve to minimize condensation and
reverse fl ow symptoms. See the "TROUBLESHOOTING" section for details.
This appliance is approved for use with a 2" (51mm) liner for air intake and a 3" (76mm)
liner for exhaust. For best performance, however, it is recommended to use two 3"
(76mm) liners.
If a 2" (51mm) liner is used for the intake, it may be necessary to adjust the
primary air shutter.
A. OUTSIDE: Slip the one end of a liner a
minimum of 2"
(51mm)
over the sleeve of
the air terminal. Secure using 3 screws.
Then seal the joint and screw heads with
W573-0007 Mill-Pac (not supplied). Repeat
with the other liner.
NOTE: We recommend that the other
end of the exhaust liner be marked
to eliminate the exhaust liner being
connected to the intake collar at the
appliance.
B. Gently stretch the liners to the required
lengths and insert into the chimney. Trim
and fi t the fl ashing plate to suit the chimney
termination. Place the air terminal onto the
top of the chimney. Make weather tight by
sealing with caulking (not supplied). Fasten
to the chimney with screws and plugs (not
supplied).
C. INSIDE: Remove the securing screw from
the front of the vent mounting plate. Pull
the vent mounting plate only, back into
the track, to the front stop. Start the slider
back into position. Re-secure the screw.
The appliance may now be pushed into
its fi nal position inside the wood burning
appliance, and the screw tightened until
the slider has been pulled tight to the front
stop.
D. Route the fl ex liners through the slider.
Attach and secure the liners to the vent
mounting plate using the same procedure
as before, ensuring that the marked
exhaust liner is attached to the exhaust collar.
FLASHING
PLATE
2” (50.8mm)
OVERLAP
INTAKE
EXHAUST
HIGH TEMP
SEALANT
MOUNTING
PLATE
SECURING
SCREW
INTAKE
EXHAUST
2" (50.8mm)
OVERLAP
MILL-PAC
2" (50.8mm)
LINER
3" (76.2mm)
LINER
SLIDER
REDUCER
CONNECTION
ILLUSTRATED WITH A 2"
(50.8mm) INTAKE LINER.
2.2 chimney connection
Chimney installation must conform to both national and local code requirements. The chimney must be lined with
one 2" (50.8mm) or 3" (76.2mm) diameter liner for intake and one 3" (76.2mm) diameter liner for exhaust. The
minimum and maximum vent lengths are 10ft (3m) and 35ft (10.7m) respectively. Recommended kits come in 3
lengths:
1-2"Ø (25.4mm-50.8mm) & 1-3"Ø (25.4mm-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND
EXHAUST & 2-3"Ø (50.8mm-76.2mm) TO 2"Ø (50.8mm) REDUCERS:
GDI-2320KT VENT KIT 20FT (6.1m)
GDI-2325KT VENT KIT 25FT (7.6m)
GDI-2335KT VENT KIT 35FT (10.7m)
2-3"Ø (50.8mm-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT VENT KIT 20FT (6.1m)
GDI-325KT VENT KIT 25 FT (7.6m
GDI-335KT VENT KIT 35 FT (10.7m)
W415-2343 / A / 11.12.19
EN
10
installation
2.3 gas installation
2.4 optional wall switch
!
WARNING
Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames.
Support gas control when attaching gas supply pipe to prevent damaging gas line.
Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened
or removed. Purging of the gas supply line should be performed by a qualifi ed service technician. Ensure
that a continuous gas fl ow is at the burner before closing the door. Ensure adequate ventilation. For gas and
electrical locations, see “dimensions” section.
All gas connections must be contained within the appliance when complete (gas fi replaces only).
High pressure will damage valve. Disconnect gas supply piping before testing gas line at test pressures above
1/2 PSIG.
Valve settings have been factory set, do not change.
Installation and servicing to be done by a qualifi ed installer.
Move the appliance into position and secure.
If equipped with a fl ex connector, the appliance is designed to accept a 1/2” (13mm) gas supply. Without the
connector, it is designed to accept a 3/8” (9.5mm) gas supply. The appliance is equipped with a manual shut
off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current
CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA
54 in the United States.
When fl exing any gas line, support the gas valve so that the lines are not bent or kinked.
The gas line fl ex-connector should be installed to provide suffi cient movement for shifting the burner assembly
on its side to aid with servicing components.
Check for gas leaks by brushing on a soap and water solution. Do not use open fl ame.
!
WARNING
Do not connect either the wall switch, thermostat or gas valve directly to 110 volt electricity.
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:
WIRE SIZE MAX. LENGTH
14 gauge (1.8mm) 100 feet (30.5m)
16 gauge (1.5mm) 60 feet (18.3m)
18 gauge (1.2mm) 40 feet (12.2m)
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.
ADD IMAGE
HERE
3
1
2
EN
W415-2343 / A / 11.12.19
11
3.0 fi nishing
6” (152mm) MANTEL
3”
4”
5”
12”
(305mm)
13”
(330mm)
14”
(356mm)
15”
(381mm)
TOP OF APPLIANCE
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed. These same requirements apply to any combustibles protruding on either side of the appliance.
0
$
1
7
(
/
+
(
,
*
+
7
345 6
MANTEL DEPTH
14" (356mm)
12" (305mm)
13" (330mm)
15" (381mm)
(76mm) (102mm) (127mm) (152mm)
3.1 minimum mantel clearances
!
WARNING
Risk of fi re!
Never obstruct the front opening of the appliance.
The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite,
etc., provided that these materials do not go below the specifi ed dimension, as illustrated.
Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched.
Facing and/or fi nishing material must never overhang into the appliance opening.
The glass door assembly is a safety device designed to pivot forward when relieving excess pressure that
might occur. Finishing or other materials must not be located in the opening surrounding the door as this will
interfere with the doors ability to relieve pressure.
If applicable, drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must
be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage
resulting from this condition is not covered by the warranty policy.
!
WARNING
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions
may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
W415-2343 / A / 11.12.19
EN
12
nishing
3.2 safety screen removal and installation
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
Before the glass door can be removed, the faceplate and safety screen must be removed. Lift the faceplate up
and off the appliance door and remove from the appliance.
FLASHING
SAFETY SCREEN
TOP CLIPS
BOTTOM BRACKETS
SAFETY SCREEN FRAME
TOP BRACKETS
DOOR FRAME
TOP BRACKETS
SCREWS
A.
B.
C.
D.
A. Remove the top clips and set aside.
B. Remove the safety screen from the safety
screen frame by sliding it up and out.
C. Remove the two screws from the top
brackets of the safety screen frame.
D. Lift the safety screen frame up and away
from door frame.
REMOVAL:
INSTALLATION:
E. Install the safety screen frame into the
bottom brackets of the door frame and
secure the top brackets with the 2 screws
into the top brackets of the door frame.
F. Slide the safety screen into the safety screen
frame.
G. Install the top clips.
H. Ensure the safety screen is installed correctly
before using the appliance.
!
WARNING
Glass may be hot. Do not touch glass until cooled.
If equipped with door latches that are part of a safety system, they must be properly engaged. Do not
operate the appliance with latches disengaged.
Facing and/or fi nishing materials must not interfere with air fl ow through air openings, louvre openings,
operation of louvres, or doors/access for service. Observe all clearances when applying combustible
materials.
Before door is removed, turn the appliance off and wait until appliance is cool to the touch. Doors are heavy
and fragile so handle with care.
EN
W415-2343 / A / 11.12.19
13
nishing
To open the door, the safety screen must be
removed to allow the door to be opened or closed.
Release the top and bottom door latches, located
at the right side of the door. Reverse these steps to
close the door. Ensure the safety screen is installed
correctly before using appliance.
DOOR LATCH
3.3 door removal and installation
A. Remove the 3 screws from the location shown
in the base of the fi rebox.
B. Secure the grate to the fi rebox base using the 3
screws removed.
3.4 grate installation
The protective wrap on plated parts is best re-
moved when the assembly is at room tempera-
ture but this can be improved if the assembly is
warmed, using a hair dryer or similar heat source.
note:
W415-2343 / A / 11.12.19
EN
14
nishing
3.5 log placement
PHAZER
TM
logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is
different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.
Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour
pigments burn in during the heat activated curing process.
A. Place the rear log so that it rests against the two
log brackets on the back wall of the fi rebox. The
air space between the log and fi rebox back is
used to facilitate combustion air fl ow.
B. Move the charcoal strip into position lining
up the holes in the bottom with the studs
located on the burner. Ensure strip sits fl at on
the burner.
B
A
A
E. Line up the square hole in the right crossover
with the square post located on the right side
of log and install as shown.
F. Line up the rectangular hole in the left crossover
with the rectangular post located on the left
side of log and install as shown.
B
A
C
D
E
B
A
C
D
E
F
C. Position the front right log just behind the
grate. Line up the log with the studs located
on the log support.
D. Move the left log into position lining up the hole
in the bottom with the stud on the left side of
the log support.
B
A
C
B
A
C
D
!
WARNING
Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved
with this appliance may result in property damage or personal injury.
Logs must be placed in their exact location in the appliance. Do not modify the proper log positions, since
appliance may not function properly and delayed ignition may occur.
The logs are fragile and should be handled with care.
EN
W415-2343 / A / 11.12.19
15
nishing
3.6 optional charcoal embers
3.7 glowing embers
3.8 logo placement
Randomly place the charcoal embers along the front and sides of the log support in a realistic manner.
Fine dust found in the bottom of the bag should not be used.
!
WARNING
Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon
deposits and delayed ignition.
When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner.
note:
Charcoal embers are not to be placed on the burner.
T
ear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be
taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
The ember material will only glow when exposed to direct fl ame; however, care should be taken to not
b
lock off the burner ports.
Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZER™
logs glow when exposed to direct fl ame. Use only certifi ed “glowing embers” and PHAZER logs available from
your local authorized dealer / distributor.
!
WARNING
Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed
ignition.
Remove the backing of the logo supplied and place, as illustrated.
1/2"(12.7mm)
LOGO
1/2"(12.7mm)
W415-2343 / A / 11.12.19
EN
16
4.0 blower replacement
black
white
red
SPEED
CONTROL
SWITCH
BLOWER
THERMAL
SWITCH
FRONT BLOWER ACCESS COVER
REAR BLOWER ACCESS COVER
A. Turn off the electrical power and the gas
supply to the appliance.
B. Open the glass door and remove the logs and
bre bricks, if installed.
C. Remove the front blower access cover held on
with 4 screws.
D. Remove the rear blower access cover. NOTE:
Check the blower gasket for damage.
Replace if damaged.
E. Disconnect the two blower wires. Remove the
blower from the mounting plate and replace.
For thermal switch replacement: Remove the
mounting bracket secured to the underside of
the burner base. Remove the thermal switch
from the bracket and replace.
F. Reconnect the two wires. Re-install the blower
gasket. Reattach the blower mounting plate
and blower access covers. Replace the logs.
Close the fi re viewing door.
G. Turn the gas supply and electricity back on.
Because the blower is thermally activated,
when turned on, it will automatically start
approximately 5-15 minutes after lighting the
appliance and will run for approximately 30-45
minutes after the appliance has been turned
off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower
bearings causing irreparable damage and must
be prevented from coming into contact with
the blower or its compartment. Any damage
resulting from this condition is not covered by
the warranty policy.
THERMAL SWITCH / BRACKET
ASSEMBLY
!
WARNING
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan’s power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
EN
W415-2343 / A / 11.12.19
17
5.0 operation
!
WARNING
Do not turn on if children or other at risk individuals are near the appliance.
This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly.
Before operating, smell all around the appliance area for gas and next to the fl oor because some gas is heavier
than air and will settle on the fl oor.
Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try
to repair it. Call a qualifi ed service technician. Force or attempted repair may result in a fi re or explosion.
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and replace any part of the control system and any gas control which has been
underwater.
FOR YOUR SAFETY READ BEFORE LIGHTING
WHAT TO DO IF YOU SMELL GAS
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
A. Stop! Read the above safety information on this label.
B. Remove batteries from the transmitter and set thermostat to lowest setting, if equipped.
C. Turn off all electrical power to the appliance.
D. Open the glass door, if equipped.
E. Turn the gas knob clockwise to the “OFF” position.
F. Wait fi ve (5) minutes to clear out any gas. If you smell gas including near the fl oor, STOP!
Follow the instructions above in the “WHAT TO DO IF YOU SMELL GAS” section. If you
don’t smell gas; close the glass door and go to the next step.
G. If the appliance is equipped with fl ame adjustment valve turn clockwise to “OFF”.
H. Turn gas knob counter-clockwise to the “PILOT” position. (If the appliance is equipped
with an “ON/OFF” switch, ensure it is in the “ON” position.
I. Depress and hold gas knob while lighting the pilot with the push button ignitor. Keep knob
fully depressed for one minute, then release. If pilot does not continue to burn, repeat steps
E through I.
J. With pilot lit, turn gas knob counter-clockwise to the “ON” position.
K. If equipped with the fl ame adjustment valve, push and turn the knob to high.
L. Turn on all electrical power to the appliance and re-install the batteries into the transmitter, if
equipped. Set thermostat to desired setting, if equipped.
A. Set thermostat to desired setting, if equipped.
B. Turn off all electrical power to the appliance if service is to be performed.
C. Push in gas knob slightly and turn clockwise to the “OFF” position. Do not force.
Turn off all gas to the appliance.
• Open windows.
Do not try to light any appliance.
Do not touch any electric switch; do not use
any phone in your building
Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fi re department.
If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal
injury, or loss of life.
If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door
opened or removed.
add gas knob
add gas valve
Ensure that a continuous gas fl ow is at the burner before installing the door. When lit for the fi rst time, the appliance
will emit an odor for a few hours. This is a normal temporary condition caused by the “burn-in” of paints and
lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation
such as following a vacation or a warm weather season, the appliance may emit a slight odor for a few hours. This
is caused by dust particles in the heat exchanger burning off. In both cases, open a window to suffi ciently ventilate
the room.
For vent free appliances ONLY: if the appliance shuts off, do not relight until you provide fresh air. If appliance
keeps shutting off, have it serviced. Keep burner and control compartment clean.
note:
When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is
depressed.
W415-2343 / A / 11.12.19
EN
18
6.0 adjustments
6.1 pilot burner adjustment
6.2 venturi adjustment
GDI-30
NG 1/4” (6.4mm)
P 3/8” (9.5mm)
6.3 fl ame characteristics
Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on “HI”.
Outlet pressure can be checked the same as above using screw
(B). Gauge should read as described on the chart below. Check
pressure with main burner operating on “HI”.
After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite
™)
can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
INSERT PILOT ASSEMBLY
*Maximum inlet pressure not to exceed 13”
Pressure Natural Gas
(inches)
Natural Gas
(millibars)
Propane
(inches)
Propane
(millibars)
Inlet
*7”
(minimum 4.5”)
17.4mb
(minimum 11.2mb)
13”
(minimum 11”)
32.4mb
(minimum 27.4mb)
Outlet
3.5” 8.7mb 10” 24.9mb
PILOT
BURNER
THERMOCOUPLE
THERMOPILE
P
I
P
I
L
O
T
N
O
L
O
T
H
I
L
O
F
F
O
This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER.
AIR
SHUTTER
OPENING
VENTURI
BURNER
ORIFICE
It is important that the orifice is securely inserted into the venturi.
note:
It’s important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
3/8” - 1/2”
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
EN
W415-2343 / A / 11.12.19
19
7.0 maintenance
!
WARNING
Turn off the gas and electrical power before servicing the appliance.
Appliance may be hot. Do not service until appliance has cooled.
Do not use abrasive cleaners on glass.
Do not paint the pilot assembly.
This appliance and its venting system should be inspected before use and at least annually by a qualifi ed
service person. The following suggested checks should be performed by a qualifi ed technician. The appliance
area must be kept clear and free of combustible materials, gasoline, or other fl ammable vapors and liquids.
The fl ow of combustion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to ex-
pose both assemblies.
2. Keep the control compartment, media, burner, air shutter opening and the area surrounding the appli-
ance clean by vacuuming or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning
or are not burning properly.
4. Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple /
thermopile as well as it reaches the burner.
5. If your appliance is equipped with a safety barrier, cleaning may be necessary due to excessive lint /
dust from carpeting, pets, etc. simply vacuum using the brush attachment.
6. If your appliance is equipped with relief doors, ensure the system performs effectively. Check that the
gasket is not worn or damaged. Replace if necessary.
7. Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning
which can be distributed in the surrounding living area, inside the fi rebox and on exterior surfaces sur-
rounding vent termination.
8. Check to see that the main burner ignites completely on all ports when turned on. A 5 to 10 second
total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer / dis-
tributor.
9. Visually inspect the appliance for carbon build up. Using a small whisk or brush, brush off the carbon
and vacuum up or sweep into garbage.
10. This step is not applicable for Vent Free appliances: Check to see that the appliance is vent-
ing correctly. Ensure chimney system is safe and unobstructed. (If for any reason the vent air intake
system is disassembled, re-install and re-seal per the instructions provided for the initial installation).
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
note:
W415-2343 / A / 11.12.19
EN
20
maintenance
7.1 annual maintenance
7.2 care of glass
!
WARNING
This appliance will require maintenance which should be planned on an annual basis.
Service should include cleaning, battery replacement, venting inspection and inspection of the burner,
media, and fi rebox. Refer to the door removal section and remove the door as instructed.
Carefully remove media if necessary (logs, glass, brick panels, etc.).
Using a vacuum with soft brush attachment, gently remove any dirt, debris, or carbon build up from the
logs, fi rebox, and burner. For glass media, follow the installation instructions for pre-cleaning.
Gently remove any build-up on the pilot assembly including thermopile, thermocouple, fl ame sensor, and
igniter (if equipped).
Inspect all accessible gaskets and replace as required.
If equipped with a blower, access the blower and clean using a soft brush and vacuum.
Re-assemble the various components in reverse order.
Inspect the relief system. The appliance relieves through the main glass door or through the fl aps on the
rebox top. Ensure they open freely, and close sealed.
Check the gas control valve pilot and Hi / Lo knobs move freely, if equipped. Replace if any stiffness in
movement is experienced.
Check for gas leaks on all gas connections up and downstream from the gas valve including pilot tube
connections.
Clean fl ame sensor using a fi ne emery cloth or a synthetic scrub pad (such as Scotch-Brite™) to remove any
oxides. Clean the pilot assembly using a vacuum with a soft brush attachment. It is important that the pilot
assembly is not painted.
note:
Annual maintenance should be performed by a qualifi ed service technician
The fi rebox becomes very hot during operation. Let the appliance cool completely or wear heat resistant
gloves before conducting service.
Never vacuum hot embers.
Do not paint the pilot assembly
!
WARNING
Buff lightly with a clean dry soft cloth to remove accumulated dust or fi ngerprints. Clean both sides of the glass
after the fi rst 10 hours of operation with an ammonia-free glass cleaner.
Thereafter, clean as required. If the glass is not kept clean permanent discoloration and / or blemishes may
result. Contact you local authorized dealer / distributor for complete cleaning instructions.
Razor blades, steel wool, or other metallic objects must not be used on both surfaces of the glass. Doing so
can remove a thin layer of metal from the razor blades, steel wool, or other metallic objects that may then be
deposited onto the coating. This can result in a discoloured stain or scratch-like mark. More importantly, this can
scratch the glass surface, thereby reducing its strength.
Do not operate the appliance with broken glass, as leakage of fl ue gases may result.
Contact your local authorized dealer / distributor for complete cleaning instructions.
If the glass should ever crack or break while the fi re is burning, do not open the door until the fi re is out. Do not
operate the appliance until the glass has been replaced. Contact you local authorized dealer / distributor for
replacement parts. DO NOT SUBSTITUTE MATERIALS.
Vinegar-based glass cleaners have demonstrated an ability to provide a clean, streak free glass surface.
note:
Do not clean glass when hot! Do not use abrasive cleaners to clean glass.
This appliance is factory equipped with 5mm ceramic glass. Use only replacement parts as supplied by the
a
pp
liance manufacturer. DO NOT SUBSTITUTE MATERIALS.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

NAPOLEON GDI-30NSB Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur

dans d''autres langues