Publication 58UHF-IN002A-EN-P - December 2022 | - Month Year
Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the Japan
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur
Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
EtherNet/IP is a trademark of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.
For technical support, visit rok.auto/support.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
10007114406 Ver 00
Waste Electrical and Electronic Equipment (WEEE)
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
At the end of life, this equipment should be collected separately from any unsorted municipal waste.
Connector Pinouts
FCC Notice (For U.S. Customers)
This transmitter must not be co-located or operated in conjunction with any other
antenna or transmitter. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: (1) This device will not cause
harmful interference; and (2) this device must accept any interference received,
including interference that may cause undesired operation of the device.
Changes and modifications not expressly approved by Rockwell Automation can
void your authority to operate this equipment under Federal Communications
Commissions rules.
This equipment is tested and found to comply with the limits for a Class A digital
device, according to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is
operated in a commercial environment.
ISED Information
This device complies with Innovation, Science and Economic Development Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference; and (2) this device must
accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Table 1 - EtherNet/IP (1)
(1) E1 - Standard right-angle Ethernet cables point left.
E2 - Standard right-angle Ethernet cables point right.
DC M12, D-coded, 4-pin Plug Pin Signal Color
1 TxData + White/orange
2 Recv Data + White/green
3 TxData - Orange
4Recv Data - Green
Table 2 - Power I/O
DC M12, D-coded, 4-pin Socket Pin Signal Color
1+24V DC Brown
2Input White
3 0V DC Blue
4Output Black
ATTENTION: This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instruction manual, can cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference, in which case you must correct the interference
at your own expense.
IMPORTANT This equipment complies with FCC radiation exposure
limits for an uncontrolled environment and meets the FCC
radio frequency (RF) Exposure Guidelines. When you install
and operate this equipment, keep a minimum of 90 cm
(35.4 in.) between the radiator and a person’s body.
IMPORTANT This equipment complies with ISED radiation exposure
limits for an uncontrolled environment and meets RSS-102
of the ISED radio frequency (RF) Exposure rules. Install and
operate this equipment keeping a minimum of 90 cm
(35.4 in.) between the radiator and a person’s body.
Cet équipement est conforme aux limites d’exposition aux
rayonnements énoncées pour un environnement
non-contrôlé et respecte les règles d’exposition aux
fréquences radioélectriques (RF) CNR-102 de l’ISDE. Cet
équipement doit être installé et utilisé en gardant une
distance de 90 cm (35.4 in.) ou plus entre le radiateur et le
corps humain.