Mounting
Method of mounting CONTROL
• The DCS™ Digital Control Solution mount to a junction box with 1/2 inch
knockout.
Mounting instructions
• Remove the top lock nut from the 1/2” chase nipple.
• Place line voltage wires and 1/2” chase nipple through 1/2” knockout.
• Reinstall the lock nut and tighten.
Installer
This high-quality product has been manufactured, tested and packaged with the
assurance of your complete satisfaction. Please read all of the instructions before
installation. This will help you to be familiarized with all the features and options
available to you with these devices. This will also assist you to minimize installation
time and provide maximum energy savings and trouble-free operation.
Safety Warnings
WARNING
• Disconnect the power supply before attempting any wiring to the device!
• Confirm that power has been switched OFF at the breaker and power is OFF
with a voltage tester.
• Installing this device requires connections to an AC power supply.
• The wiring of this device must be carried out professionally and in accordance
with all local and National Electric Codes and electrical operating conditions.
• Class 2 outputs are not suitable for Class 1 installations.
• CAUTION Risk of Electric Shock – More than one disconnect switch may be
required to de-energize the device before servicing.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interfer-
ence in which case the user will be required to correct the interference at his own
expense.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate this
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Wiring
• Before installation, make sure that power has been switched off at the breaker
and check that the circuit is dead with a voltage meter.
• After installation, verify wiring is correct to avoid damage to the controller,
lighting, and control devices.
This device and its antenna(s) must not be co-located or operating in conjunction
with any other antenna or transmitter.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innova-
tion, Science and Economic Development Canada’s licence-exempt RSS(s). Operation
is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
The transmitter module may not be co-located with any other transmitter or antenna.
CAN ICES-3 (A)/NMB-3(A)
• Max. wire length for Data Line:
– 18 AWG – 100 meters
– 16 AWG – 200 meters.
Product Overview
Purpose of CONTROL
The DCS™ Digital Control Solution integrates load control with occupancy sensors,
photo sensors, switches and other devices to provide simple code compliant solutions
for lighting, plug load and HVAC integration through BACnet*. It is a powerful, flexible,
scalable, easy to install digital control solution designed to provide maximum energy
savings. It uses a two wire data line or Bluetooth Mesh to create a local network and to
make the system expandable. It is a Type 1.C automatic operating control.
For indoor use only.
Content
1 × DCS™
1 × Users Manual
1 × Label for the Relay description
3 × Peel O QR Codes with the device identification MAC Adress
2 × Lock nuts
*BACnet: Available only for the DCS ConnectTM version.
Operation
List of all key features
• Plug & Play Operation
Provides a code compliant solution for most applications without the need of
programming. The system is designed to immediate work in a basic configuration
(default scene) once power has been turned on for the first time. The default scene
consist of the following settings:
– Steinel Sensors connected to the data line are automatically recognized by the
system. Sensor settings:
■Time Delay: 20 min
■Light Level: Full brightness
■Sensitivity: Maximum (available only for US and HF sensors)
■Partial ON in 50 % all loads
– Photo sensor
■Open Loop Mode
■Assigned to relay 1. Automatic daylighting begins after 1 minute and assigns
between 30 – 50 fc at desk level.
■Hold OFF active
– Steinel switches are automatically assigned according to their button description.
– Demand Response
■Light level dimmed at maximum of 85 % when demand response signal is
active.
• 3 × 20 A Relays and expandable
The DCS™ comes with the ability to control 3 × independent circuits (120 V or
277V) that can be used for lighting or plug loads. The system is expandable by
adding additional gateways to the data line.
• Current Monitoring Per Relay
Current monitoring is available on each relay in the DCS™.
• 3 × 0-10 V Dimming Zones
The system oers 3 × 0-10 V dimming channels.
• Data Line
The data line is a two wire polarity insensative bus that networks all sensors,
switches, photo sensors and other devices. The data line is supplied with 200 mA
and can address a maximum of 100 devices.
Specifications
Voltage 120 / 277Vac, 50/60Hz
DCS™ Dimensions 6.69 × 4.94 × 2.16 in
170.0 × 125.0 × 54.8 mm
Threaded Nipple
Dimensions
1.07 × .83 in
27.2 × 21.0 mm
Power input Single Phase 120 / 277 Vac, 50/60Hz
Data Line Output
12-22.5 Vdc / 200 mA SELV* (Class 2)
*Safety Extra Low Voltage (SELV),
Class 2 installation only.
Type of load controlled
by each circuit
3 × 120/277 Vac, 20 A Tungsten, ELV
3 × 120/277 Vac, 20 A Standard Ballast, MLV
3 × 120/277 Vac, 16 A Electronic Ballast, LED, CFL
3 × 120 Vac, 20 FLA, 120 LRA, 1 Hp
3 × 120 Vac, 20 A Receptacle-Load Plug
Dimming Output 3 × 0-10V,100mA, max. 50 compatible drivers
Demand Response Input 1 × 12-24V, 1mA
Time Clock Input 1 × 12-24V, 1mA
RTC Battery Lifetime 10 years
Building Control * BACnet IP (RJ45 connector)
Rated for indoor use only 14-104 °F / -10-40 °C, Type 1 / IP20
Pollution Degree 2
Impulse Voltage 4000 V
Standard UL 60730-1
UL 2043 Plenum Rated
FCC ID W8J-7212
IC ID 8529A-7212
5 year warranty
Made in Switzerland
www.steinel.net
* Building Control: Available only for the DCS ConnectTM version.
Product Overview
5
3
6
2
7
8
4
9
Line voltage wires
2 Cover release button
3 Test buttons
4 Low voltage terminals. Press and hold for connection and disconnection
5 1/2 inch threaded chase nipple with two lock nuts
6 LED status indicator
7 RESET Button
8 BACnet port *
9 3 × 1/2” knockout
* BACnet port: Available only for the DCS ConnectTM version.
• Daylight Harvesting
When used with the Steinel PS DCS photo sensor the system is capable of both
open loop and closed loop zone control.
• Partial On & O
Both Partial ON and Partial OFF functions can be used in combination with the
occupancy sensor and time clock functions.
• Receptacle Control
All relays are capable of 20A receptacle control. It can either be occupancy or time
based control.
• Use Cases
In order to make commissioning easier, dierent settings and parameters can be
bundled and saved into use cases. This oers the possibility to commission rooms
with the same requirements by simply selecting the desired use case.
A stored use case can be emailed and shared with others.
• Demand Response Input
The DCS™ has an input terminal that receives a dry contact closure designed for
demand response. When multiple room controllers are connected to each other
over Bluetooth, the demand response signal can be forwarded through the mesh
network.
• External Time Clock Input
For integration with an existing external time clock via a dry contact closure.
• Internal Time Clock
The internal time clock features:
– time of day,
– day of week,
– calendar settings,
– holiday scheduling,
– astronomic time functions (dusk & dawn) via GPS locator in the tablet or smart
phone used during programming.
• Min. & Max. dimming levels
Minimum and maximum dimming levels can be assigned to each switching zone.
• Group assignment
Individual relays in multiple DCS™ Controllers can be associated to groups for mass
command assignment over BLE Mesh.
• Light Scenes
Dierent light scenes can be programmed and started by the following options:
– manual switch
– time clock (internal or external)
– demand response input
– occupancy sensor
– photo sensor
– astronomic time function (dusk & dawn)
• BLE
The controllers are capable of the following BLE functions:
– wireless programming via app on a tablet or smart phone
– interconnectivity over Bluetooth Mesh between devices for mass updates
– wireless system expansion of controllers over BLE Mesh
• BACnet
The DCS Connect™ version comes with a RJ45 BACnet TCP/IP port for inte-
gration into the Building Management Systems. BACnet object list available under
www.steinel.net
• LED
– LED lights on at power up
– LED blinks continously fast mode during data line commission
– LED blinks slowly with 2 sec delay in normal operation mode
• Reset
Reset button on the housing
Within 10 min after power ON:
– Press and hold the reset button for 5 s to reset login and password. Settings
performed by the installer will not be lost.
– Press and hold the reset button for 15 s to reset login, password and restablish
factory settings.
After the 10 min window elapses:
the power must be turned OFF and back ON to perform a full reset again.
Reset button in the App:
Push the reset button in the APP to reset login and password. Settings will be lost
and factory settings will be initiated.
• 3 Test buttons
Allows the installer to turn ON / OFF each relay for testing of the line voltage wiring.
110083408 04/2023 Subject to technical modification without notice.
• App connection over Bluetooth. After installing the Steinel DCSTM
commissioning App on the smartphone or tablet, click on search to find nearby
installed devices.
– User name: admin
– Password: admin123
Warranty
STEINEL America warrants its products against defects in material or workmanship
for a period of five years. STEINEL will replace or repair the item provided that it has
not been altered or subjected to abuse, accident, improper installation or improper
use. There are no obligations or liabilities on the part of STEINEL for consequential
damages arising out of or in connection with the use or performance of this product
or other indirect damages with respect to loss of property, revenue, or profit, or cost
of removal, installation or reinstallation.
MANUFACTURER'S
1
3
5
YEAR
GB
WARRANTY
MANUFACTURER'S
YEAR
WARRANTY
MANUFACTURER'S
YEAR
WARRANTY
À l’attention de l’électricien
Ce produit de qualité supérieure a été fabriqué, testé et emballé afin de vous donner
entière satisfaction. Veuillez lire attentivement et entièrement ces instructions avant de
procéder à l’installation de l’appareil. Elles vous aideront à vous familiariser avec toutes
les caractéristiques et options oertes par ces appareils. Elles contribueront à minima-
liser la durée d’installation, à réaliser un maximum d’économies d’énergie et à garantir
une utilisation sans problème.
Consignes de sécurité
ATTENTION
• Débranchez l’appareil de l’alimentation électrique avant tout câblage vers l’appareil !
• Assurez-vous que l’alimentation électrique a été COUPÉE au niveau du coupe-circuit
et vérifiez que l’alimentation électrique est COUPÉE avec un testeur de tension.
• L’installation de cet appareil implique la connexion à une alimentation électrique CA.
• Le câblage de cet appareil doit être eectué par des professionnels en respectant
toutes les réglementations électriques nationales et locales ainsi que les conditions
d’utilisation électriques.
• Les sorties de classe 2 ne conviennent pas aux installations de classe 1.
• ATTENTION Risque de choc électrique - Plus d’un interrupteur peut être néces-
saire pour mettre l’appareil hors tension avant l’entretien.
Déclaration de la FCC sur les interférences
Cet équipement a été testé et jugé conforme aux limites applicables et aux appareils
numériques de classe A, conformément à la partie 15 des règles de la FCC. Ces
limites sont conçues pour fournir une protection raisonnable contre les interférences
nuisibles lorsque l’équipement est utilisé dans un environnement commercial. Cet
équipement génère, utilise et peut émettre de l’énergie de radiofréquence et, s’il n’est
pas installé et utilisé conformément au manuel d’instructions, il peut causer des inter-
férences nuisibles aux communications radio. L’utilisation de cet équipement dans une
zone résidentielle est susceptible de provoquer des interférences nuisibles, auquel cas
l’utilisateur devra corriger ces interférences à ses propres frais.
Attention FCC : Tout changement ou modification non expressément approuvé par
la partie responsable de la conformité pourrait annuler l’autorisation pour l´utilisateur à
pouvoir utiliser cet équipement.
Cet appareil est conforme à la partie 15 des règles de la FCC. Son utilisation est
soumise aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d’interfé-
rences nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y compris les
interférences qui peuvent causer un fonctionnement non souhaité.
Cet appareil et ses antennes ne doivent pas être placés ou fonctionner en conjonction
avec une autre antenne ou un autre émetteur.
NOTE IMPORTANTE :
Déclaration de la FCC sur l’exposition aux radiations :
Cet équipement est conforme aux limites d’exposition aux radiations de la FCC
établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé
avec une distance minimale de 20 cm entre la source de rayonnement et votre corps.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme
aux CNR d’Innovation, Sciences et Développement économique du Canada, appli-
cables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
REMARQUE IMPORTANTE :
Déclaration d’IC sur l’exposition aux rayonnements :
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies
pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec
une distance minimale de 20cm entre la source de rayonnement et votre corps.
Le module émetteur ne doit pas être installé au même endroit qu’un autre émetteur ou
une autre antenne.
CAN ICES-3 (A)/NMB-3(A)
Aperçu du produit
Objectif du CONTROL
Le DCS™ (ou la solution de commande numérique) comprend le contrôle de la charge
au moyen des détecteurs de présence, des photodétecteurs, des interrupteurs et
d’autres appareils pour fournir des solutions compatibles avec des codes simples
pour l’éclairage, la charge des prises électriques et l’intégration de la CVC via BACnet*.
C’est une solution de contrôle numérique puissante, flexible, évolutive et facile à
installer destinée à garantir un maximum d’économies d’énergie. Elle utilise une ligne
de données bifilaire ou Bluetooth Mesh pour créer un réseau local ou pour rendre le
système extensible. Il s’agit d’un contrôle de fonctionnement automatique de type 1.C.
Pour usage à l’intérieur uniquement.
Contenu
1 DCS™
1 manuel de l’utilisateur
1 étiquette pour la description des relais
3 codes QR décollables indiquant l’identification de l’appareil (adresse MAC)
2 contre-écrous
*BACnet: seulement disponible pour la version DCS ConnectTM.
Spécifications
Tension 120 / 277Vac, 50/60Hz
Dimensions du DCS™ 6,69 × 4,94 × 2,16 po
170,0 × 125,0 × 54,8 mm
Dimensions de l’embout
fileté
1,07 × 0,83 po
27,2 × 21,0 mm
Alimentation électrique monophasée 120 / 277 Vac , 50/60Hz
Sortie de la ligne de
données
12-22,5 Vdc / 200 mA SELV* (classe 2)
*Safety Extra Low Voltage (SELV),
Installation de classe 2 uniquement
Type de charge contrôlée
par chaque circuit
3 × 120/277 Vac, 20 A tungstène, électronique basse
tension
3 × 120/277 Vac, 20 A ballast standard, magnétique
basse tension
3 × 120/277 Vac, 16 A ballast électronique, LED,
lampe fluorescente compacte
3 × 120 Vac,20 FLA, 120 LRA, 1 Hp
3 × 120 Vac, 20 A fiche de charge - logement
Sortie de variation de
l’intensité lumineuse
3 × 0-10V,100 mA, au maximum 50 pilotes
compatibles
Entrée réponse à la
demande
1 × 12-24 V, 1 mA
Entrée minuterie 1 × 12-24 V, 1 mA
Durée de vie de la batterie
en temps réel (RTC)
10 ans
Gestion technique du
bâtiment *
BACnet IP (connecteur RJ45)
Calibré pour usage à
l’intérieur uniquement
14-104 °F / -10-40 °C, type 1 / IP20
Degré de pollution 2
Tension d’impulsion 4000 V
Standard UL 60730-1
Classe plenum UL 2043
FCC ID W8J-7212
IC ID 8529A-7212
5 ans de garantie
Fabriqué en Suisse
www.steinel.net
* Gestion technique du bâtiment: seulement disponible pour la version DCS
ConnectTM.
Aperçu du produit
5
3
6
2
7
8
4
9
Fils d’alimentation
2 Bouton d’ouverture du couvercle
3 Boutons de test
4 Terminaux basse tension. Appuyez et maintenez enfoncé le bouton pour
la connexion et la déconnexion
5 Raccord fileté à emboutir 1/2 pouce avec deux contre-écrous
6 LED indicateur d’état
7 Bouton de réinitialisation
8 Port BACnet *
9 3 débouchures de 1/2 pouce
*PortBACnet: seulement disponible pour la version DCS Connect™.
Montage
Méthode de montage de CONTROL
• Le DCS™ (la solution de commande numérique) se monte sur un boîtier de
jonction avec une débouchure de 1/2 pouce (1,27 cm).
Instructions de montage
• Retirez le contre-écrou supérieur du raccord à emboutir 1/2 po (1,27 cm).
• Faites passer les fils d’alimentation et le raccord à emboutir 1/2 po (1,27 cm) à
travers la débouchure 1/2 po (1,27 cm).
• Réinstallez le contre-écrou puis serrez.
Câblage
• Avant l’installation, assurez-vous que l’alimentation électrique a été coupée au
niveau du disjoncteur et que le courant ne passe plus dans le circuit, au moyen
d’un testeur de tension.
• Après l’installation, vérifiez que le câblage est correct afin d’éviter tout dommage
au niveau du contrôleur, de l’éclairage et des dispositifs de commande.
Longueur max. des fils pour Data Line :
– calibre 18 AWG (0,82 mm²) – 100 mètres
– calibre 16 AWG (1,31 mm²) – 200 mètres
Hot (120/277V)
Hot (120/277V)
Hot (120/277V)
Neutral
Hot
Neutral 3
Hot
Neutral 2
Hot
Neutral 1
Black (Relay 1 - Hot 120/277 V)
Red (Relay 1 - Switched Hot)
Blue (Relay 2)
Blue (Relay 2)
Yellow (Relay 3)
Yellow (Relay 3)
White (Neutral)
0-10V Dimming / Zone 3
0-10V Dimming / Zone 2
0-10V Dimming / Zone 1
+ 10V Dimming Ballast (Violet)
– 10V Dimming Ballast (Gray)
+ 10V Dimming Ballast (Violet)
– 10V Dimming Ballast (Gray)
+ 10V Dimming Ballast (Violet)
– 10V Dimming Ballast (Gray)
(–) 0-10V Dimming Channel 1
(+) 0-10V Dimming Channel 1
(–) 0-10V Dimming Channel 2
(+) 0-10V Dimming Channel 2
(–) 0-10V Dimming Channel 3
(+) 0-10V Dimming Channel 3
Data Line DA (–)
Data Line DA (+)
Demand Response
Time Clock
SwitchSensor
Other
Devices
Photo
Sensor
Reset
Sous tension (120/277V)
Sous tension (120/277V)
Sous tension (120/277V)
Neutre
Sous tension
Neutre 3
Sous tension
Neutre 2
Sous tension
Neutre 1
Noir (relais 1 - sous tension 120/277 V)
Rouge (relais 1 - com. s. tens.)
Bleu (relais 2)
Bleu (relais 2)
Jaune (relais 3)
Jaune (relais 3)
Blanc (neutre)
Variation de l’intensité
lumineuse 0-10 V / Zone 3
Variation de l’intensité
lumineuse 0-10 V / Zone 2
Variation de l’intensité
lumineuse 0-10 V / Zone 1
+ Ballast de var. de l’int. lum. 10 V (violet)
– Ballast de var. de l’int. lum. 10 V (gris)
+ Ballast de var. de l’int. lum. 10 V (violet)
– BBallast de var. de l’int. lum. 10 V (gris)
+ Ballast de var. de l’int. lum. 10 V (violet)
– Ballast de var. de l’int. lum. 10 V (gris)
(–) Var. de l’int. lum. 0-10 V / Canal 1
(+) Var. de l’int. lum. 0-10 V / Canal 1
(–) Var. de l’int. lum. 0-10 V / Canal 2
(+) Var. de l’int. lum. 0-10 V / Canal 2
(–) Var. de l’int. lum. 0-10 V / Canal 3
(+) Var. de l’int. lum. 0-10 V / Canal 3
Ligne des données DA (–)
Ligne des données DA (+)
Réponse à la demande
Minuterie
InterrupteurDétecteur
Autres
dispositifs
Photo-
détecteur
Réinitialisation
US
FR