IMPORTANT SAFEGUARDS
Read these instructions carefully and retain them for future use.
If this product is passed to a third party, then these instructions
must be included.
When using electrical appliances, basic safety precautions should always
be followed to reduce the risk of fi re, electric shock, and/or injury to
persons including the following:
WARNING
Risk of injury! Do not use the water collected in the
water tank for drinking purposes. It is not sanitary and could cause illness
or personal injury hazard.
WARNING
System contains refrigerant under very high pressure.
Do not tamper with the system. It must be serviced by qualifi ed
personsonly.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the product.
Do not block air inlets and/or air outlets.
Do not operate with wet hands.
Do not disassemble or modify the product.
Always switch off the product before pulling the power plug out of the
wall outlet.
This product shall be installed in accordance with national wiring
regulations.
Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock, fi re or damage
the product.
Disconnect the plug from the wall outlet when not using the product
for a long time.
Do not operate any appliance with a damaged cord or plug or
after the appliance malfunctions, or is dropped or damaged in any
manner. Return appliance to the nearest authorized service facility for
examination, repair or electrical or mechanical adjustment.
Keep at least a space of 8” (20 cm) at the sides and the back and
16" (40 cm) at the top and the front of the product.
The vents shall not be obstructed.
4
EN
Use the product on a solid and flat surface.
Keep the product away from items and furnishings that can be
damaged by water (wooden furniture, wallpaper, etc.).
NOTICE
Fluorinated greenhouse gases are contained in hermetically
sealed equipment. For specific information on the type, the amount and
the CO2 equivalent in tonnes of the fluorinated greenhouse gas (on some
models), please refer to the relevant label on the unit itself.
Grounding Instructions
This product must be grounded while in use to protect the operator
from electrical shock. The product is equipped with a 3-conductor
cord and a 3-prong grounding-type plug. This product can only be
used with a standard 3-prong wall outlet to minimize the possibility
of electric shock. Where a 2-prong outlet is encountered, it must be
replaced with a properly grounded 3-prong wall outlet.
Always use dedicated power circuit with a dedicated circuit breaker.
Before connecting the product to the power supply, check that the
power supply voltage and current rating corresponds with the power
supply details shown on the product rating label.
If the power cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
Do not modify power cord length or share an outlet with another
appliance. This may cause electric shock or fire.
Do not use the outlet if it is loose or damaged. It may cause electric
shock.
Always plug this product directly into a wall outlet/receptacle.
Neveruse with an extension cord or relocatable power tap
(outlet/power strip).
5
EN
Grounding pin
SAVE THESE INSTRUCTIONS
Explanation of Symbols
DANGER
The signal word that indicates a hazard with a high
level of risk which, if not avoided, will result in death or
serious injury.
WARNING
The signal word that indicates a hazard with a
medium level of risk which, if not avoided, could result
in death or serious injury.
CAUTION
The signal word that indicates a hazard that if not
prevented could result in minor or moderate injury.
NOTICE
Indicates a practical tip, advice or practice not related
to personal injury.
This product is ENERGY STAR
®
certified and helps to
save energy and protect the environment. ENERGY
STAR
®
is a program run by the U.S. Environmental
Protection Agency and U.S. Department of Energy
that promotes energy efficiency.
6
EN
Intended Use
This product is intended for dehumidifying indoor rooms, basements or
other spaces. It is for preventing mold growth on clothing, cupboards,
doors and drawers, condensation on ceiling, walls and windows.
This product is intended for household use only. It is not intended for
commercial use.
This product is intended to be used in dry indoor areas only.
No liability will be accepted for damages resulting from improper use
or non-compliance with these instructions.
Before First Use
Check the product for transport damages.
Remove all the packing materials.
Take the cord winding (Q) out of the water tank (N) and attach it to
the attachment at the back of the product.
Before connecting the product to the power supply, check that the
power supply voltage and current rating corresponds with the power
supply details shown on the product rating label.
DANGER
Risk of suffocation! Keep any packaging materials
awayfrom children – these materials are a potential source of danger,
e.g. suffocation.
7
EN
Product Description
A
Defrost indicator
K
On/off button
B
Full indicator
L Control panel
C
On / off timer indicators
M Water level
D Display N Water tank
E
Auto button
O Air fi lter with grille
F
Filter button
P Drain hose outlet
G
Continuity mode button
Q Cord winding
H
Turbo button
R Power cord with plug
I
Timer button
S 1/4" (6.4 mm) drain hose
J
decrease / increase buttons
E F G H I J K
CBA D
M
N
R
S
Q
P
O
L
8
EN
Operation (Positioning)
Do not place the product in corners, directly at walls or under cabinets.
For a proper operation allow at least the distances given below.
≥ 15.7" (40 cm)
≥ 7.9" (20 cm)
≥ 7.9" (20 cm)
≥ 7.9" (20 cm)
≥ 15.7" (40 cm)
Operation (Control Panel)
NOTICE
During normal operation, the display (D) shows the actual
room humidity (% RH).
Button Function
Auto (E)
Press to activate the automatic mode. The button
indicator lights up.
The product automatically operates dependently
on the temperature and humidity to provide the
optimum comfort for the user.
Press again to deactivate the automatic mode.
Thebutton indicator goes off.
NOTICE
In this mode a preset humidity value
cannot be set manually.
9
EN
Button Function
Filter (F)
After approx. 250 hours of operation, the indicator
over the filter button lights up to remind the user to
clean the filter.
After cleaning the filter, press and hold the filter
button for 3seconds to switch the filter indicator off
and to zero the filter counter.
Continuous
operation
(G)
Press to toggle between continuous operation and
operation on demand.
Button indicator on - Continuous operation:
Theproduct operates continuously and absorbs
asmuch humidity as possible.
Button indicator off - Operation on demand: Set
manually the desired room humidity with the < >
buttons (J). The setting is shown on the display (D).
The adjustable value is 35% RH to 85% RH.
After no button was pressed for 5seconds,
thesetting is saved and the display (D) switches
tothe actual room humidity.
The product switches off, when the desired room
humidity is undercut by 1 %.
The product switches on, when the desired room
humidity is exceeded by 5 %.
Turbo (H)
Press to increase the fan speed for a faster room air
circulation. The button indicator lights up.
Press again to set the fan speed to normal speed.
The button indicator goes off.
Timer (I)
Set a timer when the product will switch on or off.
Press the button to toggle between the on and the
off timer. Which timer is actually selected is shown by
the timer indicators (C).
on timer
off timer
Set the timer with the < > buttons (K). The setting
is shown on the display (D). The adjustable value is
0.5hour to 24hours.
(Continue on next page)
10
EN
Button Function
Timer (I)
(Continued from previous page)
After no button was pressed for 5seconds, the
setting is saved and the display (D) switches to the
actual room humidity or goes off.
When a timer is set the appropriate timer indicator(C)
lights up.
NOTICE
The product restarts with its previous
settings.
NOTICE
Both timer can be set simultaneously.
Bothtimer are counting on from the present time.
Thefirst possible timer action will be implemented.
Thus, it is not possible to set both timer on the
samevalue.
< > (J)
Using the < > (J) buttons:
- The relative humidity value is inputted in increments
of5.
- The timer can be set.
On/off (K)
Press to switch the product on/off.
Indicator Description
Defrosting
(A)
Defrosting indicator: The product is defrosting its cooling
system.
Full (B)
Full indicator: The water tank (N) is full.
Operation (Functions)
NOTICE
The product does not operate, when the water tank (N)
is full or is not placed properly into the housing. In that case the
full
indicator(B) lights up, and the display (D) shows an error code.
Switching on/off
Connect the product to the a suitable socket outlet. The display (D)
and the
full indicator(B) shortly light up.
11
EN
Press the on/off button (K) to switch the product on/off.
Refer to the “Operation (Control Panel)” chapter to make the settings.
Emptying the water tank
When the water tank (N) is full the product stops its operation.
The
full indicator (B) lights up, and the display (D) shows an
errorcode.
Hold the water tank (N) on its sides and carefully pull it out.
Drain the water into a sink.
Place the water tank (N) properly into the housing.
The product restarts automatically.
Using a drain hose (continuous drainage)
When using a drain hose, the collected water is drained out of the drain
hose outlet (P). No water is collected in the water tank (N).
NOTICE
The drain hose outlet (P) has no pump. The connected
hose must be sloping downwards.
Open the drain hose outlet (P) by turning it in a counter-clockwise
direction.
12
EN
Connect a hose by using a 1" (2.54 cm) female connector
(both separately purchased).
Place the end of the drain hose at a suitable drain.
Defrost function
The product automatically performs defrosting in regular intervals
according to the ambient room temperature. The
defrost indicator(A)
lights up when this feature is activated.
NOTICE
Risk of damage! Do not switch the appliance off or pull
the power plug from the socket outlet during the defrosting operation.
NOTICE
During the defrosting operation, the dehumidification
function and air circulation function may intermit.
Cleaning and Maintenance
WARNING
Risk of electric shock! To prevent electric shock,
unplug the product before cleaning.
WARNING
Risk of electric shock! During cleaning do not
immerse the electrical parts of the product in water or other liquids.
Never hold the product under running water.
Cleaning
To clean the product, wipe with a soft, slightly moist cloth.
Dry the product after cleaning.
Never use corrosive detergents, wire brushes, abrasive scourers,
metal or sharp utensils to clean the product.
Air filter
Clean the air filter grille (O) on a
bi-weekly basis.
Pull out the air filter with grille (O)
carefully on its handle.
Clean the filter with grille (O) with
a vacuum cleaner or a soft brush.
If necessary, clean the filter under
running water.
Let the filter with grille (O) dry.
Reassemble the filter (O) into the housing.
13
EN
Storage
Drain all water out of the product and let it dry.
Store the product in its original packaging in a dry area. Keep away
from children and pets.
Avoid any vibrations and shocks.
Maintenance
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of
the person competent in the use of flammable refrigerants.
Troubleshooting
Problem Cause / Solution
The product does
not switch on.
Check if the power plug is connected to the
socket outlet. Check if the socket outlet works.
Check the water level in the water tank (N).
Check that the water tank’s (N) is properly
fitted into the housing.
The product does
not dry the air as it
should.
Wait to get enough time to remove the humidity.
Make sure there are no curtains, blinds or
furniture blocking the front or back of the
product.
The desired humidity level may not be set low
enough.
Check that all doors, windows and other
openings are securely closed.
The room temperature is too low, below 41°F
(+5 °C).
A kerosene heater or another equipment is
giving off water vapor in the room.
14
EN
Problem Cause / Solution
The product makes
a loud noise during
operation.
The air filter is clogged.
The product is tilted instead of staying upright
as it should be.
The floor surface is not leveled.
Water on floor The drain hose connection may be loose.
The drain hose outlet (P) might be opened.
Error code Cause / Solution
AS Humidity sensor error.
Bring the product to a repair service.
ES Temperature sensor error.
Bring the product to a repair service.
P2 Water container is full.
Empty the bucket.
Water container is not placed properly.
Rearrange the water container until it fits
properly in the housing.
Specifications
B07XHQQ95Y
Rated voltage: 115 V~, 60Hz, single phase
Rated current: max. 7.8 A
Power input: max. 810 W
Standby power: 1 W
Moisture removal: 50 pints/day (23.66 L/day)
R.H. range: 35 – 85 % R.H.
Rated IEF: 0.48 gal/kWh (1.8 L/kWh)
Water tank capacity: 1.59 gal (6 L)
Refrigerant: R410A, 7.4 oz (210 g)
Fan IP rating: IP04
Power cord and plug: 3- wire; grounded
Air flow: 11301/13066 cft/h (320/370 m
3
/h)
Sound emission: ≤54 dB(A)
15
EN
Operating temperature: 41 °F to 90 °F (+5 °C to +32 °C)
Net weight: approx. 41 lb (18.6 kg)
Dimensions (W x H x D):
approx. 15.4 x 24.3 x 11.1"
(392 x 616 x 282 mm)
B07XKGLMR8
Rated voltage: 115 V~, 60Hz, single phase
Rated current: max. 5.3 A
Power input: max. 560 W
Standby power: 1 W
Moisture removal: 35.37 pints/day (16.74 L/day)
R.H. range: 35 – 85 % R.H.
Rated IEF: 0.48 gal/kWh (1.8 L/kWh)
Water tank capacity: 1.59 gal (6 L)
Refrigerant: R410A, 6.7 oz (190 g)
Fan IP rating: IP04
Power cord and plug: 3- wire; grounded
Air flow: 9888/11301 cft/h (280/320 m
3
/h)
Sound emission: ≤54 dB(A)
Operating temperature: 41 °F to 90 °F (+5 °C to +32 °C)
Net weight: approx. 39.2 lb (17.8 kg)
Dimensions (W x H x D):
approx. 15.4 x 24.3 x 11.1"
(392 x 616 x 282 mm)
16
EN
B07XKGM4D4
Rated voltage: 115 V~, 60Hz, single phase
Rated current: max. 3.7 A
Power input: max. 420 W
Standby power: 1 W
Moisture removal: 22.06 pints/day (10.44 L/day)
R.H. range: 35 – 85 % R.H.
Rated IEF: 0.41 gal/kWh (1.57 L/kWh)
Water tank capacity: 0.79 gal (3 L)
Refrigerant: R410A, 5.29 oz (150 g)
Fan IP rating: IP04
Power cord and plug: 3- wire; grounded
Air flow: 7063/8122 cft/h (200/230 m
3
/h)
Sound emission: ≤55.5 dB(A)
Operating temperature: 41 °F to 90 °F (+5 °C to +32 °C)
Net weight: approx. 33 lb (15 kg)
Dimensions (W x H x D):
approx. 15.2 x 19.7 x 10.2"
(386 x 500 x 260mm)
Feedback and Help
Love it? Hate it? Let us know with a customer review.
AmazonBasics is committed to delivering customer-driven products
that live up to your high standards. We encourage you to write a review
sharing your experiences with the product.
amazon.com/review/review‑your‑purchases#
amazon.com/gp/help/customer/contact‑us
END OF USER MANUAL
17
EN
Servicing
Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of
the person competent in the use of flammable refrigerants.
Checks to the area
Prior to beginning work on systems containing flammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimised. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise
the risk of a flammable gas or vapour being present while the work is
being performed.
General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined
spaces shall be avoided. The area around the workspace shall be
sectioned off. Ensure that the conditions within the area have been made
safe by control of flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior
to and during work, to ensure the technician is aware of potentially
flammable atmospheres. Ensure that the leak detection equipment being
used is suitable for use with flammable refrigerants, i.e. non-sparking,
adequately sealed or intrinsically safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate fire extinguishing equipment shall be
available to hand. Have a dry powder or CO
2
fire extinguisher adjacent to
the charging area.
18
EN
No ignition sources
No person carrying out work in relation to a refrigeration system
which involves exposing any pipe work that contains or has contained
flammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of fire or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufficiently far away
from the site of installation, repairing, removing and disposal, during
which flammable refrigerant can possibly be released to the surrounding
space. Prior to work taking place, the area around the equipment is to
be surveyed to make sure that there are no flammable hazards or ignition
risks. No Smoking signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt consult
the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
The ventilation machinery and outlets are operating adequately and
are not obstructed;
If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected;
Refrigeration pipe or components are installed in a position where
they are unlikely to be exposed to any substance which may corrode
refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.
19
EN
Checks to electrical devices
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that
could compromise safety, then no electrical supply shall be connected
to the circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the
owner of the equipment so all parties are advised.
Initial safety checks shall include:
That capacitors are discharged: this shall be done in a safe manner
to avoid possibility of sparking;
That there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
That there is continuity of earth bonding.
Repairs to sealed components
1. During repairs to sealed components, all electrical supplies shall be
disconnected from the equipment being worked upon prior to any
removal of sealed covers, etc. If it is absolutely necessary to have an
electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical
point to warn of a potentially hazardous situation.
2. Particular attention shall be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a
way that the level of protection is affected. This shall include damage
to cables, excessive number of connections, terminals not made to
original specification, damage to seals, incorrect fitting of glands, etc.
Ensure apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they
no longer serve the purpose of preventing the ingress of flammable
atmospheres. Replacement parts shall be in accordance with the
manufacturer’s specifications.
NOTICE
The use of silicon sealant may inhibit the effectiveness of
some types of leak detection equipment. Intrinsically safe components
do not have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and
current permitted for the equipment in use.
20
EN
Intrinsically safe components are the only types that can be worked on
while live in the presence of a flammable atmosphere. The test apparatus
shall be at the correct rating.
Replace components only with parts specified by the manufacturer.
Other parts may result in the ignition of refrigerant in the atmosphere from
a leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive
pressure, vibration, sharp edges or any other adverse environmental
effects. The check shall also take into account the effects of aging or
continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for
systems containing flammable refrigerants.
Electronic leak detectors shall be used to detect flammable refrigerants,
but the sensitivity may not be adequate, or may need re-calibration
(detection equipment shall be calibrated in a refrigerant-free area). Ensure
that the detector is not a potential source of ignition and is suitable for
the refrigerant used.
Leak detection equipment shall be set at a percentage of the LFL of
the refrigerant and shall be calibrated to the refrigerant employed and
the appropriate percentage of gas (25% maximum) is confirmed. Leak
detection fluids are suitable for use with most refrigerants but the use of
detergents containing chlorine shall be avoided as the chlorine may react
with the refrigerant and corrode the copper pipe-work.
If a leak is suspected, all naked flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the
refrigerant shall be recovered from the system, or isolated (by means of
shut off valves) in a part of the system remote from the leak. Oxygen free
nitrogen (OFN) shall then be purged through the system both before and
during the brazing process.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71

AmazonBasics B07XKGLMR8 Manuel utilisateur

Taper
Manuel utilisateur