Hytronik HC603VRC-KD Tri-level Control 347V Manuel utilisateur

Taper
Manuel utilisateur
1. Technical Specifications
Product type 347VAC HF Sensor ( Tri-level control )
Operating voltage 347VAC 60Hz
Rated load 1200W / 3.5A / 347V (Incandescent)
800W / 2.4A / 347V (Fluorescent / LED)
Power consumption < 1.5W
Detection angle 30 ~ 150
o o
Max. detection area (DxH) 12 x 6m (SAM5, SAM9); 16x15m (SAM6)
Detection range 10% / 50% / 75% / 100%
Hold time 5s/30s/1min/5min/10min/20min/30min (TEST 2s ~ 30min on RC)
Stand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞
Stand-by dimming level 10% / 20% / 30% / 50%
Daylight threshold 2 ~ 500Lux, Disable (2Lux ~ 500Lux /Lux disable / Ambient on RC)
Warmming up time 20s
Operating temperature -20oC ~ +60oC
IP rating IP20
HC603VRC-KD-20170312-A1
Installation and Instruction Manual
347V TRI-LEVEL HF SENSOR, DETACHED VERSION HC603VRC-KD
Dimensions (mm)
Installation hole
Detection area
Sensor antenna interface
NL
L’
Hold time
Daylight threshold
Stand-by period
Stand-by dimming level
(D x H: 12m x 6m)
Super-compact sensor
antenna, with optional
cable entry (side entry
and back entry) and IR
receiver.
Model SAM5
26
13.5
27.5 48
4.2
95
87
80
(D x H: 12m x 6m)
Super-compact sensor
antenna, with optional
cable entry (side entry
and back entry), without
IR receiver.
Model SAM9
Cable side entry
Daylight sensor
40.4 11.2
6.8
8.8
35.9
2.5
12
25.2
30.7
Cable back entry
Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas require
a light change notice before switch-off.
It offers 3 levels of light: 100%-->dimmed light-->off; and 2 periods of selectable waiting time: motion
hold-time and stand-by time; Selectable daylight threshold and detection area.
1. Tri-level Control (Corridor Function)
2. 24h Daylight Monitoring
Hytronik specially designed this function in software for deep energy-saving purpose. A built-in daylight
sensor is designed to provide a “smart photocell” function. This function can only be activated when
stand-by period is set to “+∞”. In this mode the lamp will automatically illuminate at the dim level setting
when the natural light goes below the threshold setting. The fixture will also switch off as the natural light
returns.
Functions
Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure the
in-rush current is minimised, enabling the maximum lifetime of the relay.
3. Zero-cross relay operation
1-10V +
(purple)
1-10V -
(gray)
30.7
35.9
40.4
16.2
25.2
6
2.5
11.2
1.8
6.8
5
22.5
4
Drill hole 9mm x 3mm
Drill hole 9mm x 3mm
Drill hole for cable entry is 10mm x 10mm in
square shape or 12mm in round shape
22.5
2.5
13
4
(D x H: 16m x 15m)
Flat sensor antenna, with
plastic fingers to hook on
highbay or T5/T8 tubes
Model SAM6
Wiring Diagram
1-10V
Gray
Purple
L
L N L
+
-
LED Driver
LED
1-10V
L N
+
-
-
+
-
+
,
N
HC603VRC-KD-20170312-A1
Feature Operation
21
75%
50%
10%
100%
3
21
5s
30s
1min
5min
10min
20min
30min
21
10 Lux
50 Lux
Disable
2 Lux
3
21
0s
10s
1min
5min
10min
30min
1H
+∞
1. Detection Range
Setting these switches will determine the sensitivity of the
occupancy sensor. During commissioning it is recommeded to
start at 10% to satisfy correct installation, before increasing the
sensitivity to the environment for normal operation.
2. Hold Time
Select the dip switch configuration for the full brightness
on-time after presense detection.
Note for commissioning: There is a 20 second “warm-up”
period for the sensor upon power-on. This time must elapse
before testing for presense detection.
3. Daylight Threshold
Set the level according to the fixture and environment. In
Photocell Advanced mode this level will determine at which
point the fixture turns off and automatically turns back on again.
Disabling the daylight sensor will put the sensor into occupancy
detection only mode.
4. Stand-by period
The selected time will determine the period before the fixture
switches completely off from the stand-by dimming level in
periods of absence.
Note: Selecting Infinity ‘∞’ will put the sensor into “24h daylight
monitoring” mode.
21
30%
20%
10%
50%
5. Stand-by Dimming Level
This setting is used to select the desired dimmed light level
used in periods of absence for enhanced comfort and safety. In
Photocell Advanced mode, it is also the level the fixture will
automatically come on at when the natural daylight falls below
the daylight threshold setting.
Description of the Button Functions
(remote control HRC-11)
HRC-11
6
8
10
11
12
13
14
2
4
1
3
7
9
5
option 1
option 2
Slots for T8 tube
50.2
26.5
45.2
32.2
2.5
33.5
Slots for T5 tube
26.5
50.2
15
9
2
12
33.5
Drill hole 9mm x 3mm
Drill hole 9mm x 3mm
Drill hole for cable entry is 10mm x 10mm in
square shape or 12mm in round shape
RESET [ button ]
Press button , all settings go back to the DIP switch settings.
2
2
Shift [ button ]
Press button , the LED on the top left corner flashes to indicate mode selection.
All values / settings in RED are in valid for 20 seconds.
3
3
Auto Mode [ button ]
Press button to initiate automatic mode. The sensor starts working and all settings remain
as before the light was switched ON/OFF.
Note: The function of “SEMI-AUTO” is disabled.
4
4
Permanent ON/OFF [ ]
Press button to select permanent ON or permanent OFF mode.
* Press button / to resume automatic operation.
The mode will change to AUTO Mode after power failure.
button
1
1
2 4
Brightness +/- [ button ]
Press button to adjust light brightness between 10% ~ 100%.
6
6
Scene prog. [ zone ] (One-key-commissioning)
1. Press button “Start” to program.
2. Select the buttons in “Detection range”, / “Daylight threshold”, “Hold time”,
“Stand-by time”, “Stand-by dimming level” to set all parameters.
3. Press button “Memory” to save all the settings programmed in the remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to pre-set detection range 100%, daylight threshold Disable, hold time
5min, stand-by time +∞, stand-by dimming level 30%, steps should be:
Press button Start, button 100%, Disable, Shift, 5min, Shift, +∞,
30%, Memory. By pointing to the sensor unit(s) and pressing Apply, all
settings are passed on the sensor(s).
7
7
7
7
3 3
8
89
10
10 11
13
11
12 13
HC603VRC-KD-20170312-A1
Hytronik Industrial Ltd. | www.hytronik.com
3rd Floor, block C, complex building, 155#, Bai'gang road south,
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel: 86-752-2772020 Fax: 86-752-2777877
Dual tech & RF mode [ zone ]
All buttons in zone are disabled.
14
14
Stand-by dimming level [ zone ]
Press buttons in zone to set the stand-by dimming level at 10% / 20% / 30% / 50%.
13
13
Stand-by time [ zone ]
Press buttons in zone to set the stand-by period at 0s / 10s / 1min / 5min /
10min / 30min / 1h / +∞.
Note: “0s” means on/off control; “+∞” means the stand-by time is infinite and the
light is effectively controlled by the daylight sensor, off when natural light is
sufficient and automatically on at dimming level when insufficient.
12
12
Hold time [ zone ]
Press buttons in zone to set the hold time at 2s / 30s / 1min / 5min /10min /
15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button Shift at
first.
2. 2s is for test purpose only, stand-by period and daylight sensor settings
are disabled in this mode.
*To exit from Test mode, press button or any button in zone .
3
2
11
11
11
Ambient daylight threshold [ button ]
1. Press button Shift, the red LED flashes for indication.
2. Press button , the ambient lux level is sampled and set as the new
daylight threshold.
3
10
10
Detection range [ zone ]
Press buttons in zone to set detection range at 100% / 75% /50% / 10%.
8
8
10
10
Daylight threshold [ zone ]
Press buttons in zone to set the daylight sensor at 2Lux / 10Lux
/50Lux / 100Lux / 300Lux / 500Lux or Disable.
Note: To set daylight sensor at 100Lux / 300 Lux / 500Lux, press button
Shift at first.
9
9
3
Caution, Safety and Warning Markings in
SAFETY STOP – DO NOT ALTER
CAUTION: This product is combustible. A protective barrier or thermal barrier is required
as specified in the appropriate building code.
WARNING – Interconnection of more than one power supply source to a section of grid
rail bus may present a fire hazard.
DANGER - RADIATION
Caution, Safety and Warning Markings in
DISPOSITIF DE SÛRETÉ – NE PAS MODIFIER
ATTENTION : Ce produit est combustible. Une barrière de protection ou une barrière
thermique est exigée par le code du bâtiment en vigueur.
AVERTISSEMENT – Interconnexion de plus d’une source d’alimentation à une section
de bus sur rail grille peut présenter un risque d’incendie.
DANGER – RAYONNEMENT
Power output [ button ]
Press button , the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.
5
5
12
  • Page 1 1
  • Page 2 2
  • Page 3 3

Hytronik HC603VRC-KD Tri-level Control 347V Manuel utilisateur

Taper
Manuel utilisateur